{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T15:40:09Z","timestamp":1791214809891,"version":"4.1.0"},"reference-count":44,"publisher":"Bentham Science Publishers Ltd.","issue":"5","content-domain":{"domain":["eurekaselect.com"],"crossmark-restriction":true},"short-container-title":["CCR"],"published-print":{"date-parts":[[2023,9]]},"abstract":"<jats:sec>\n<jats:title>Abstract:<\/jats:title>\n<jats:p>The field of cardiac pacing has been defined by constant development to provide efficacious,\nsafe, and reliable therapy. Traditional pacing utilizes transvenous leads, which dwell in the\nvenous system and place patients at risk for complications, including pneumothorax, bleeding, infection,\nvascular obstruction, and valvular compromise.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>:<\/jats:title>\n<jats:p>Leadless pacemakers have been developed to overcome many of the challenges of transvenous\npacing while providing safe and effective pacing therapy for an increasing population of patients.\nThe Medtronic Micra transcatheter pacing system was approved by the FDA in April of 2016 and\nthe Abbott Aveir pacemaker was approved in April of 2022. Several additional leadless pacemakers\nare in various stages of development and testing. There exists limited guidance on the selection\nof the ideal candidate for leadless pacemakers.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>:<\/jats:title>\n<jats:p>Advantages of leadless pacemakers include decreased infection risk, overcoming limited vascular\naccess, and avoidance of interaction with the tricuspid valve apparatus. Disadvantages of leadless\npacemakers include right ventricular-only pacing, unclear lifecycle management, cost, perforation\nrisk, and lack of integration with defibrillator systems. This review aims to provide an overview of\nthe current state of the art of leadless pacemakers, currently approved systems, clinical trials and\nreal-world evidence, considerations for patient selection, and future directions of this promising\ntechnology.<\/jats:p>\n<\/jats:sec>","DOI":"10.2174\/1573403x19666230331094647","type":"journal-article","created":{"date-parts":[[2023,3,31]],"date-time":"2023-03-31T18:57:11Z","timestamp":1680289031000},"update-policy":"https:\/\/doi.org\/10.2174\/bsp_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Leadless Pacemakers: State of the Art and Selection of the Ideal Candidate"],"prefix":"10.2174","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2438-5921","authenticated-orcid":true,"given":"Evan A.","family":"Blank","sequence":"first","affiliation":[{"name":"Division of Cardiology, Section of Electrophysiology, Emory University School of Medicine, Atlanta, Georgia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mikhael F.","family":"El-Chami","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Section of Electrophysiology, Emory University School of Medicine, Atlanta, Georgia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nanette K.","family":"Wenger","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Emory University School of Medicine, Atlanta, Georgia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"965","reference":[{"key":"ref=1","doi-asserted-by":"publisher","first-page":"794","DOI":"10.1136\/heartjnl-2021-320149","volume":"108","author":"Haydock P.","year":"2022","unstructured":"Haydock P.; Camm A.J.; History and evolution of pacing and devices. Heart 2022,108(10),794-799","journal-title":"Heart"},{"key":"ref=2","doi-asserted-by":"publisher","first-page":"ii1","DOI":"10.1093\/europace\/eux258","volume":"19","author":"Raatikainen M.J.P.","year":"2017","unstructured":"Raatikainen M.J.P.; Arnar D.O.; Merkely B.; A Decade of Information on the Use of Cardiac Implantable Electronic Devices and Interventional Electrophysiological Procedures in the European Society of Cardiology Countries: 2017 Report from the European Heart Rhythm Association. Europace 2017,19(S2),ii1-ii90","journal-title":"Europace"},{"key":"ref=3","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1016\/j.hrthm.2011.12.014","volume":"9","author":"Udo E.O.","year":"2012","unstructured":"Udo E.O.; Zuithoff N.P.A.; Van Hemel N.M.; Incidence and predictors of short- and long-term complications in pacemaker therapy: The FOLLOWPACE study. Heart Rhythm 2012,9(5),728-735","journal-title":"Heart Rhythm"},{"key":"ref=4","doi-asserted-by":"publisher","first-page":"1186","DOI":"10.1093\/eurheartj\/eht511","volume":"35","author":"Kirkfeldt R.E.","year":"2014","unstructured":"Kirkfeldt R.E.; Johansen J.B.; Nohr E.A.; Jorgensen O.D.; Nielsen J.C.; Complications after cardiac implantable electronic device implantations: An analysis of a complete, nationwide cohort in Denmark. Eur Heart J 2014,35(18),1186-1194","journal-title":"Eur Heart J"},{"key":"ref=5","unstructured":"FDA approves first leadless pacemaker to treat heart rhythm disorders. Available from:"},{"key":"ref=6","doi-asserted-by":"publisher","first-page":"2604","DOI":"10.1056\/NEJMc1604852","volume":"374","author":"Reynolds D.W.","year":"2016","unstructured":"Reynolds D.W.; Ritter P.; A Leadless intracardiac transcatheter pacing system. N Engl J Med 2016,374(26),2604-2605","journal-title":"N Engl J Med"},{"key":"ref=7","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1016\/j.jacep.2019.10.017","volume":"6","author":"Steinwender C.","year":"2020","unstructured":"Steinwender C.; Khelae S.K.; Garweg C.; Atrioventricular synchronous pacing using a leadless ventricular pacemaker. JACC Clin Electrophysiol 2020,6(1),94-106","journal-title":"JACC Clin Electrophysiol"},{"key":"ref=8","unstructured":"Aveir Leadless Pacing System \u2013 Aveir Leadless Pacemaker, Model LSP112V (Right Ventricular); Aveir Delivery Catheter, Model LSCD111; and Aveir Link Module, Module LSL02 \u2013 P150035. Available from:"},{"key":"ref=9","year":"2022","unstructured":"Abbott. Instructions for Use. Available from: 2022"},{"key":"ref=10","doi-asserted-by":"publisher","first-page":"1375","DOI":"10.1016\/j.hrthm.2017.05.017","volume":"14","author":"Roberts P.R.","year":"2017","unstructured":"Roberts P.R.; Clementy N.; Al Samadi F.; A leadless pacemaker in the real-world setting: The micra transcatheter pacing system post-approval registry. Heart Rhythm 2017,14(9),1375-1379","journal-title":"Heart Rhythm"},{"key":"ref=11","doi-asserted-by":"publisher","first-page":"1800","DOI":"10.1016\/j.hrthm.2018.08.005","volume":"15","author":"El-Chami M.F.","year":"2018","unstructured":"El-Chami M.F.; Al-Samadi F.; Clementy N.; Updated performance of the micra transcatheter pacemaker in the real-world setting: A comparison to the investigational study and a transvenous historical control. Heart Rhythm 2018,15(12),1800-1807","journal-title":"Heart Rhythm"},{"key":"ref=12","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.1056\/NEJMoa1507192","volume":"373","author":"Reddy V.Y.","year":"2015","unstructured":"Reddy V.Y.; Exner D.V.; Cantillon D.J.; Doshi R.; Bunch T.J.; Tomassoni G.F.; Percutaneous implantation of an entirely intracardiac leadless pacemaker. N Engl J Med 2015,373(12),1125-1135","journal-title":"N Engl J Med"},{"key":"ref=13","doi-asserted-by":"publisher","first-page":"1756","DOI":"10.1016\/j.hrthm.2017.07.004","volume":"14","author":"Lakkireddy D.","year":"2017","unstructured":"Lakkireddy D.; Knops R.; Atwater B.; Neuzil P.; Ip J.; Gonzalez E.; A worldwide experience of the management of battery failures and chronic device retrieval of the Nanostim leadless pacemaker. Heart Rhythm 2017,14(12),1756-1763","journal-title":"Heart Rhythm"},{"key":"ref=14","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2021.11.002","author":"Reddy V.Y.","year":"2021","unstructured":"Reddy V.Y.; Exner D.V.; Doshi R.; Tomassoni G.; Jared Bunch T.; Mark Estes N.; Primary results on safety and efficacy from the leadless ii\u2013phase 2 worldwide clinical trial. JACC Clin Electrophysiol 2021","journal-title":"JACC Clin Electrophysiol"},{"key":"ref=15","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1093\/eurheartj\/ehq497","volume":"32","author":"Johansen J.B.","year":"2011","unstructured":"Johansen J.B.; J\u00f8rgensen O.D.; M\u00f8ller M.; Arnsbo P.; Mortensen P.T.; Nielsen J.C.; Infection after pacemaker implantation: infection rates and risk factors associated with infection in a population-based cohort study of 46299 consecutive patients. Eur Heart J 2011,32(8),991-998","journal-title":"Eur Heart J"},{"key":"ref=16","doi-asserted-by":"publisher","first-page":"1393","DOI":"10.1016\/j.hrthm.2020.03.019","volume":"17","author":"El-Chami M.F.","year":"2020","unstructured":"El-Chami M.F.; Bonner M.; Holbrook R.; Leadless pacemakers reduce risk of device-related infection: Review of the potential mechanisms. Heart Rhythm 2020,17(8),1393-1397","journal-title":"Heart Rhythm"},{"key":"ref=17","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1016\/j.hrcr.2016.04.006","volume":"2","author":"Koay A.","year":"2016","unstructured":"Koay A.; Khelae S.; Wei K.K.; Muhammad Z.; Mohd Ali R.; Omar R.; Treating an infected transcatheter pacemaker system via percutaneous extraction. HeartRhythm Case Rep 2016,2(4),360-362","journal-title":"HeartRhythm Case Rep"},{"key":"ref=18","doi-asserted-by":"publisher","first-page":"863","DOI":"10.1016\/j.hrcr.2020.08.022","volume":"6","author":"Ellison K.","year":"2020","unstructured":"Ellison K.; Hesselson A.; Ayoub K.; Leung S.; Gurley J.; Retrieval of an infected leadless pacemaker. HeartRhythm Case Rep 2020,6(11),863-866","journal-title":"HeartRhythm Case Rep"},{"key":"ref=19","doi-asserted-by":"publisher","first-page":"3427","DOI":"10.1093\/eurheartj\/ehab364","volume":"42","author":"Glikson M.","year":"2021","unstructured":"Glikson M.; Nielsen J.C.; Kronborg M.B.; 2021 ESC guidelines on cardiac pacing and cardiac resynchronization therapy. Eur Heart J 2021,42(35),3427-3520","journal-title":"Eur Heart J"},{"key":"ref=20","doi-asserted-by":"publisher","first-page":"2685","DOI":"10.1016\/S0735-1097(20)33312-X","volume":"75","author":"Shehadeh M.","year":"2020","unstructured":"Shehadeh M.; Costello J.; Brar V.; Hadadi C.; Successful micra leadless pacemaker implantation through an iliac vein stent. J Am Coll Cardiol 2020,75(11),2685","journal-title":"J Am Coll Cardiol"},{"key":"ref=21","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1016\/j.jacep.2017.07.014","volume":"4","author":"Kolek M.J.","year":"2018","unstructured":"Kolek M.J.; Crossley G.H.; Ellis C.R.; Implantation of a MICRA leadless pacemaker via right internal jugular vein. JACC Clin Electrophysiol 2018,4(3),420-421","journal-title":"JACC Clin Electrophysiol"},{"key":"ref=22","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1002\/joa3.12478","volume":"37","author":"Morani G","year":"2021","unstructured":"Morani G; Bolzan B; Pepe A; Ribichini FL; Leadless pacemaker through tricuspid bioprosthetic valve: Early experience. J arrhythmia 2021,37(2),414-7","journal-title":"J arrhythmia"},{"key":"ref=23","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.hroo.2020.03.002","volume":"1","author":"Padala SK","year":"2020","unstructured":"Padala SK; Ellenbogen KA; Left bundle branch pacing is the best approach to physiological pacing. 2020,1(1),59-67"},{"key":"ref=24","author":"Aveir D.R.","unstructured":"Aveir D.R.; Aveir DR i2i Study. Patent NCT05252702 Available from:"},{"key":"ref=25","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.hrthm.2021.06.1195","volume":"19","author":"Okabe T.","year":"2022","unstructured":"Okabe T.; Hummel J.D.; Bank A.J.; Leadless left ventricular stimulation with WiSE-CRT System - Initial experience and results from phase I of SOLVE-CRT study (nonrandomized, roll-in phase). Heart Rhythm 2022,19(1),22-29","journal-title":"Heart Rhythm"},{"key":"ref=26","first-page":"740","volume":"23","author":"Carabelli A.","year":"2021","unstructured":"Carabelli A.; Jabeur M.; Jacon P.; Rinaldi C.A.; Leclercq C.; Rovaris G.; European experience with a first totally leadless cardiac resynchronization therapy pacemaker system. EP Eur 2021,23(5),740-747","journal-title":"EP Eur"},{"key":"ref=27","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1111\/jce.14825","volume":"32","author":"Bhatia N.K.","year":"2021","unstructured":"Bhatia N.K.; Kiani S.; Merchant F.M.; Life cycle management of Micra transcatheter pacing system: Data from a high\u2010volume center. J Cardiovasc Electrophysiol 2021,32(2),484-490","journal-title":"J Cardiovasc Electrophysiol"},{"key":"ref=28","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1111\/pace.12804","volume":"39","author":"Omdahl P.","year":"2016","unstructured":"Omdahl P.; Eggen M.D.; Bonner M.D.; Iaizzo P.A.; Wika K.; Right ventricular anatomy can accommodate multiple micra transcatheter pacemakers. Pacing Clin Electrophysiol 2016,39(4),393-397","journal-title":"Pacing Clin Electrophysiol"},{"key":"ref=29","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1007\/s10840-019-00684-y","volume":"57","author":"Dar T.","year":"2020","unstructured":"Dar T.; Akella K.; Murtaza G.; Comparison of the safety and efficacy of Nanostim and Micra transcatheter leadless pacemaker (LP) extractions: A multicenter experience. J Interv Card Electrophysiol 2020,57(1),133-140","journal-title":"J Interv Card Electrophysiol"},{"key":"ref=30","doi-asserted-by":"publisher","first-page":"3053","DOI":"10.2169\/internalmedicine.1066-18","volume":"57","author":"Satoh T.","year":"2018","unstructured":"Satoh T.; Fukui A.; Katoh S.; Matsui M.; A leadless pacemaker which became encapsulated only two months after placement. Intern Med 2018,57(20),3053","journal-title":"Intern Med"},{"key":"ref=31","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1111\/pace.12804","volume":"5","author":"Kiani S.","year":"2019","unstructured":"Kiani S.; Merchant F.M.; El-Chami M.F.; Extraction of a 4-year-old leadless pacemaker with a tine-based fixation. HeartRhythm Case Rep 2019,5(8),424","journal-title":"HeartRhythm Case Rep"},{"key":"ref=32","doi-asserted-by":"crossref","first-page":"841","DOI":"10.1016\/j.hrthm.2018.02.008","volume":"15","author":"Afzal M.R.","year":"2018","unstructured":"Afzal M.R.; Daoud E.G.; Cunnane R.; Techniques for successful early retrieval of the Micra transcatheter pacing system: A worldwide experience. Heart Rhythm 2018,15(6),841-846","journal-title":"Heart Rhythm"},{"key":"ref=33","doi-asserted-by":"publisher","DOI":"10.1109\/WPT.2018.8639120","author":"Campi T.","year":"2018","unstructured":"Campi T.; Cruciani S.; De Santis V.; Maradei F.; Feliziani M.;  Feasibility study of a wireless power transfer system applied to a leadless pacemaker 2018","journal-title":"Feasibility study of a wireless power transfer system applied to a leadless pacemaker"},{"key":"ref=34","year":"2018","unstructured":"The Micra TM transcatheter pacing system, a leadless pacemaker, in patients indicated for single-chamber ventricular pacemaker implantations. Health Technology Assessment 2018","journal-title":"Health Technology Assessment"},{"key":"ref=35","doi-asserted-by":"publisher","first-page":"1132","DOI":"10.1016\/j.hrthm.2021.03.015","volume":"18","author":"Hauser R.G.","year":"2021","unstructured":"Hauser R.G.; Gornick C.C.; Abdelhadi R.H.; Tang C.Y.; Casey S.A.; Sengupta J.D.; Major adverse clinical events associated with implantation of a leadless intracardiac pacemaker. Heart Rhythm 2021,18(7),1132-1139","journal-title":"Heart Rhythm"},{"key":"ref=36","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.121.024756","volume":"11","author":"Fong K.Y.","year":"2022","unstructured":"Fong K.Y.; Ng C.J.R.; Wang Y.; Yeo C.; Tan V.H.; Subcutaneous versus transvenous implantable defibrillator therapy: A systematic review and meta-analysis of randomized trials and propensity score\u2013matched studies. J Am Heart Assoc 2022,11(11)","journal-title":"J Am Heart Assoc"},{"key":"ref=37","doi-asserted-by":"publisher","first-page":"1349","DOI":"10.1111\/j.1540-8167.2010.01825.x","volume":"21","author":"Saeed M.","year":"2010","unstructured":"Saeed M.; Neason C.G.; Razavi M.; Programming antitachycardia pacing for primary prevention in patients with implantable cardioverter defibrillators: results from the PROVE trial. J Cardiovasc Electrophysiol 2010,21(12),1349-1354","journal-title":"J Cardiovasc Electrophysiol"},{"key":"ref=38","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1002\/joa3.12140","volume":"35","author":"Ng J.B.","year":"2019","unstructured":"Ng J.B.; Chua K.; Teo W.S.; Simultaneous leadless pacemaker and subcutaneous implantable cardioverter-defibrillator implantation-When vascular options have run out. J Arrhythmia 2019,35(1),136","journal-title":"J Arrhythmia"},{"key":"ref=39","doi-asserted-by":"publisher","first-page":"628","DOI":"10.1016\/j.hrcr.2021.06.006","volume":"7","author":"Elliott M.K.","year":"2021","unstructured":"Elliott M.K.; Sidhu B.S.; Mehta V.S.; Gould J.; Martic D.; Rinaldi C.A.; The importance of leadless pacemaker positioning in relation to subcutaneous implantable cardioverter-defibrillator sensing in completely leadless cardiac resynchronization and defibrillation systems. HeartRhythm Case Rep 2021,7(9),628-632","journal-title":"HeartRhythm Case Rep"},{"key":"ref=40","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1007\/s00399-018-0602-y","volume":"29","author":"Tjong F.V.Y.","year":"2018","unstructured":"Tjong F.V.Y.; Koop B.E.; The modular cardiac rhythm management system: The EMPOWER leadless pacemaker and the EMBLEM subcutaneous ICD. Herzschr Elektrophys 2018,29(4),355","journal-title":"Herzschr Elektrophys"},{"key":"ref=41","doi-asserted-by":"publisher","first-page":"1686","DOI":"10.1093\/europace\/euz230","volume":"21","author":"Piccini J.P.","year":"2019","unstructured":"Piccini J.P.; Stromberg K.; Jackson K.P.; Patient selection, pacing indications, and subsequent outcomes with de novo leadless single-chamber VVI pacing. Europace 2019,21(11),1686-1693","journal-title":"Europace"},{"key":"ref=42","doi-asserted-by":"publisher","first-page":"832","DOI":"10.1111\/jce.14881","volume":"32","author":"El-Chami M.F.","year":"2021","unstructured":"El-Chami M.F.; Shinn T.; Bansal S.; Leadless pacemaker implant with concomitant atrioventricular node ablation: Experience with the Micra transcatheter pacemaker. J Cardiovasc Electrophysiol 2021,32(3),832-841","journal-title":"J Cardiovasc Electrophysiol"},{"key":"ref=43","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1111\/jce.13851","volume":"30","author":"El-Chami M.F.","year":"2019","unstructured":"El-Chami M.F.; Johansen J.B.; Zaidi A.; Leadless pacemaker implant in patients with pre-existing infections: Results from the Micra postapproval registry. J Cardiovasc Electrophysiol 2019,30(4),569","journal-title":"J Cardiovasc Electrophysiol"},{"key":"ref=44","doi-asserted-by":"publisher","first-page":"1207","DOI":"10.1093\/eurheartj\/ehab767","volume":"43","author":"El-Chami M.F.","year":"2022","unstructured":"El-Chami M.F.; Bockstedt L.; Longacre C.; Leadless vs. transvenous single-chamber ventricular pacing in the Micra CED study: 2-year follow-up. Eur Heart J 2022,43(12),1207-1215","journal-title":"Eur Heart J"}],"container-title":["Current Cardiology Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.eurekaselect.com\/article\/download?doi=10.2174\/1573403X19666230331094647","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.eurekaselect.com\/215316\/article","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.eurekaselect.com\/article\/download?doi=10.2174\/1573403X19666230331094647","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T12:15:11Z","timestamp":1693570511000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.eurekaselect.com\/215316\/article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9]]},"references-count":44,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2023,9]]}},"alternative-id":["LiveAll1"],"URL":"https:\/\/doi.org\/10.2174\/1573403x19666230331094647","relation":{},"ISSN":["1573-403X"],"issn-type":[{"value":"1573-403X","type":"print"}],"subject":[],"published":{"date-parts":[[2023,9]]},"assertion":[{"value":"Peer Reviewed","order":0,"name":"review_status","label":"Review Status","group":{"name":"peer_review_details","label":"Peer Review Details"}},{"value":"Single blind","order":1,"name":"review_process","label":"Review Process","group":{"name":"peer_review_details","label":"Peer Review Details"}},{"value":"Checked with iThenticate","order":0,"name":"screening_status","label":"Screening Status","group":{"name":"plagiarism_screening","label":"Plagiarism Screening"}},{"value":"2022-08-08","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-01-17","order":1,"name":"revised","label":"Revised","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-01-24","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-07-17","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e310323215316"}}