{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,18]],"date-time":"2025-11-18T15:39:54Z","timestamp":1763480394915,"version":"3.37.3"},"reference-count":0,"publisher":"Bentham Science Publishers Ltd.","issue":"11","funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea: Basic Science Research Program","doi-asserted-by":"publisher","award":["2018R1D1A1B07048833"],"award-info":[{"award-number":["2018R1D1A1B07048833"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["eurekaselect.com"],"crossmark-restriction":true},"short-container-title":["CMIR"],"published-print":{"date-parts":[[2021,11]]},"abstract":"<jats:sec>\n<jats:title>Purpose:<\/jats:title>\n<jats:p>Kidney, Ureter, and Bladder radiography (KUB) has frequently been used in\nsuspected urolithiasis, but its performance is known to be lower than that of Computed Tomography\n(CT). This study aimed to investigate the diagnostic performance of digitally KUB in the detection\nof ureteral stones.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Materials And Methods:<\/jats:title>\n<jats:p>Thirty patients who underwent digital KUB and CT were included in this\nretrospective study. The original digital KUB underwent post-processing that involved noise estimation,\nreduction, and whitening in improving the visibility of ureteral stones. Thus, 60 digital original\nor post-processed KUB images were obtained and ordered randomly for blinded review. After\na period, a second review was performed after unblinding stone laterality. The detection rates were\nevaluated at both initial and second reviews, using CT as a reference standard. The objective (size)\nand subjective (visibility) parameters of ureteral stones were analyzed. Fisher\u2019s exact test was used\nto compare the detection sensitivity between the original and post-processed KUB data set. Visibility\nanalysis was assessed with a paired t-test. The correlation of stone size between CT and digital\nKUB data sets was assessed with the Pearson\u2019s correlation test.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Results:<\/jats:title>\n<jats:p>The detection rate was higher for most reviewers once stone laterality was provided and\nwas non-significantly better for the post-processed KUB images (p &gt; 0.05). There was no significant\ndifference in stone size among CT and digital KUB data sets. In all reviews, visibility grade\nwas higher in the post-processed KUB images, irrespective of whether stone laterality was provided.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Conclusion:<\/jats:title>\n<jats:p>Digital post-processing of KUB yielded higher visibility of ureteral stones and could\nimprove stone detection, especially when stone laterality was available. Thus, digitally post-processed\nKUB can be an excellent modality for detecting ureteral stones and measuring their exact\nsize.<\/jats:p>\n<\/jats:sec>","DOI":"10.2174\/1573405617666210218094812","type":"journal-article","created":{"date-parts":[[2021,2,19]],"date-time":"2021-02-19T15:56:46Z","timestamp":1613750206000},"page":"1356-1362","update-policy":"https:\/\/doi.org\/10.2174\/bsp_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Detection of Ureteral Stones in Kidney Ureter Bladder Radiography: Usefulness of Digital Post-processing"],"prefix":"10.2174","volume":"17","author":[{"given":"Sang Lim","family":"Choi","sequence":"first","affiliation":[{"name":"Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul,Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8163-3181","authenticated-orcid":true,"given":"Sung Bin","family":"Park","sequence":"additional","affiliation":[{"name":"Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul,Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seungwook","family":"Yang","sequence":"additional","affiliation":[{"name":"Samsung Electronics, Suwon,Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eun Sun","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul,Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hyun Jeong","family":"Park","sequence":"additional","affiliation":[{"name":"Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul,Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jong Beum","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul,Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Byung Ihn","family":"Choi","sequence":"additional","affiliation":[{"name":"Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul,Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"965","container-title":["Current Medical Imaging Formerly Current Medical Imaging Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.eurekaselect.com\/article\/download\/191532","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.eurekaselect.com\/191532\/article","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.eurekaselect.com\/article\/download\/191532","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,27]],"date-time":"2022-03-27T12:41:38Z","timestamp":1648384898000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.eurekaselect.com\/191532\/article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,11]]},"references-count":0,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2021,11]]}},"alternative-id":["LiveAll1"],"URL":"https:\/\/doi.org\/10.2174\/1573405617666210218094812","relation":{},"ISSN":["1573-4056"],"issn-type":[{"type":"print","value":"1573-4056"}],"subject":[],"published":{"date-parts":[[2021,11]]},"assertion":[{"value":"Peer Reviewed","order":0,"name":"review_status","label":"Review Status","group":{"name":"peer_review_details","label":"Peer Review Details"}},{"value":"Single blind","order":1,"name":"review_process","label":"Review Process","group":{"name":"peer_review_details","label":"Peer Review Details"}},{"value":"Checked with iThenticate","order":0,"name":"screening_status","label":"Screening Status","group":{"name":"plagiarism_screening","label":"Plagiarism Screening"}},{"value":"2020-09-13","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-12-30","order":1,"name":"revised","label":"Revised","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-01-01","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-12-15","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}