{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,3,20]],"date-time":"2024-03-20T14:42:20Z","timestamp":1710945740389},"reference-count":10,"publisher":"Bentham Science Publishers Ltd.","issue":"1","license":[{"start":{"date-parts":[[2010,8,17]],"date-time":"2010-08-17T00:00:00Z","timestamp":1282003200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/3.0\/"}],"content-domain":{"domain":["openbiomedicalengineeringjournal.com","benthamopen.com"],"crossmark-restriction":true},"short-container-title":["TOBEJ"],"published-print":{"date-parts":[[2010,8,17]]},"abstract":"<jats:p>Micromotion has long been associated with wear of polyethylene tibial inserts, potentially causing failure of unicompartmental knee replacement systems. One cause of micromotion is the locking mechanism between the undersurface of the polyethylene and the tibial tray. The objective of this study was to investigate the use of new novel lock designs for reducing the micromotion associated with a patient specific tibial implant. Micromotion occurring between the tibial insert and tibial tray was measured using the DVRT method for two new lock designs and compared to the micromotion measured for the prior generation lock design. In total, 18 samples were tested, six in each of the three designs: prior generation CLEARANCE lock design, new LINE-TO-LINE design, new INTERFERENCE design.<\/jats:p>\n                <jats:p>At the lowest loading of 100N, the motion index of the new interference lock design (4.9 \u00b12.6 microns) was less than the motion index of both the new line-to-line lock design (11.9\u00b14.5 microns) and the prior generation clearance lock design (154.9\u00b184.4 microns). Likewise, at the higher loading of 400N, the motion index of the new interference lock design (58.7 \u00b17.2 microns) was again less than the motion index of the two alternative lock designs (new line-to-line: 135.5\u00b157.6 microns; prior generation clearance: 371.8\u00b1151.4 microns). When compared to previously published micromotion data for TKR systems, the results demonstrate that a novel interference design locking mechanism as part of a patient-specific unicompartmental knee arthroplasty system can significantly reduce micromotion that is believed to be one of the causes of osteolysis.<\/jats:p>","DOI":"10.2174\/1874120701004010156","type":"journal-article","created":{"date-parts":[[2010,9,6]],"date-time":"2010-09-06T04:20:43Z","timestamp":1283746843000},"page":"156-161","update-policy":"http:\/\/dx.doi.org\/10.2174\/crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Patient-Specific Unicompartmental Knee Resurfacing Arthroplasty: Use of a Novel Interference Lock to Reduce Tibial Insert Micromotion and Backside Wear"],"prefix":"10.2174","volume":"4","author":[{"given":"Nick","family":"Steklov","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nam","family":"Chao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sudesh","family":"Srivastav","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"965","reference":[{"key":"refR1","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1097\/00003086-199811000-00003","volume":"356","author":"Parks N.L.","year":"1998","unstructured":"Parks NL , Engh GA, Topoleski JLD, Emparado J. \n                    Modular tibial insert micromotion \n                    CORR  \n                    1998 Nov; \n                    \n                    356\n                    : 10-5.","journal-title":"CORR"},{"key":"refR2","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1097\/00003086-199712000-00009","volume":"345","author":"Wasielewski RC","year":"1997","unstructured":"Wasielewski RC. \n                    \u201cTibial insert undersurface as a contributing source of polyethylene wear debris,\u201d \n                    CORR  \n                    1997 Dec; \n                    \n                    345\n                    : 53-9.","journal-title":"CORR"},{"key":"refR3","first-page":"326","volume":"87","author":"Conditt MA","year":"2005","unstructured":"Conditt MA, Thompson MT, Usrey MM, Ismaily SK, Noble PC. \n                    \u201cBackside wear of polyethylene tibial inserts: mechanisms and magnitude of material loss,\u201d \n                    J Bone Joint Surg Am  \n                    2005 Feb; \n                    \n                    87\n                    : 326-31.","journal-title":"J. Bone Joint Surg. Am"},{"key":"refR4","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1097\/01.blo.0000148853.37270.67","volume":"428","author":"Fehring TK","year":"2004","unstructured":"Fehring TK, Murphy JA, Hayes TD, Roberts DW, Pomeroy DL, Griffin WL. \n                    \u201cFactors influencing wear and osteolysis in press-fit condylar modular total knee replacements,\u201d \n                    CORR  \n                    2004 Nov; \n                    \n                    428\n                    : 40-50.","journal-title":"CORR"},{"key":"refR5","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1007\/s11420-006-9033-0","volume":"3","author":"Jayabalan P","year":"2007","unstructured":"Jayabalan P, Furman BD, Cottrel JM, Wright TM. \n                    \u201cBackside wear in modern total knee designs,\u201d \n                    HSS J  \n                    2007 Feb; \n                    \n                    3\n                    : 30-4.","journal-title":"HSS J"},{"key":"refR6","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1016\/j.jbiomech.2010.01.015","volume":"43","author":"Billi F","year":"2010","unstructured":"Billi F, Sangiorgio SN, Aust S, Ebramzadeh E. \n                    \u201cMaterial and surface factors influencing backside fretting wear in total knee replacement tibial components,\u201d \n                    J Biomech  \n                    2010 May; \n                    \n                    43\n                    : 1310-5.","journal-title":"J. Biomech"},{"key":"refR7","unstructured":"Scott RD. \n                    Total Knee Arthroplasty. \n                    Elsevier 2006."},{"key":"refR8","unstructured":"Engh G. \n                    \u201cTibial baseplate wear; a major source of debris with contemporary modular knee implants,\u201d AAOS \n                     In: 67th Annual Meeting - Scientific Exhibit; \n                    Mar. 15-19, 2000; \n                    Orlando Florida."},{"key":"refR9","author":"Slamin J","year":"2005","unstructured":"Slamin J. \n                    \u201cA new cobalt chrome tibial tray and moderately cross-linked tibial insert is added to the PFC Sigma modular knee system,\u201d \n                    DePuy technical paper \n                    2005.","journal-title":"DePuy technical paper"},{"key":"refR10","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.2106\/00004623-200405000-00022","volume":"86-A","author":"Conditt MA","year":"2004","unstructured":"Conditt MA, Ismaily SK, Alexander JW, Noble PC. \n                    \u201cBackside wear of modular ultra-high molecular weight polyethylene tibial inserts,\u201d \n                    J Bone Joint Surg Am  \n                    2004 May; \n                    \n                    86-A\n                    : 1031-7.","journal-title":"J. Bone Joint Surg. Am"}],"container-title":["The Open Biomedical Engineering Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/openbiomedicalengineeringjournal.com\/contents\/volumes\/V4\/TOBEJ-4-156\/TOBEJ-4-156.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/openbiomedicalengineeringjournal.com\/contents\/volumes\/V4\/TOBEJ-4-156\/TOBEJ-4-156.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/openbiomedicalengineeringjournal.com\/contents\/volumes\/V4\/TOBEJ-4-156\/TOBEJ-4-156.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,7,1]],"date-time":"2019-07-01T05:22:31Z","timestamp":1561958551000},"score":1,"resource":{"primary":{"URL":"https:\/\/openbiomedicalengineeringjournal.com\/VOLUME\/4\/PAGE\/156\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,8,17]]},"references-count":10,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2010,8,17]]}},"alternative-id":["TOBEJ-4-156"],"URL":"https:\/\/doi.org\/10.2174\/1874120701004010156","relation":{},"ISSN":["1874-1207"],"issn-type":[{"value":"1874-1207","type":"print"}],"subject":[],"published":{"date-parts":[[2010,8,17]]},"assertion":[{"value":"Peer Reviewed","order":0,"name":"review_status","label":"Review Status","group":{"name":"peer_review_details","label":"Peer Review Details"}},{"value":"Single blind","order":1,"name":"review_process","label":"Review Process","group":{"name":"peer_review_details","label":"Peer Review Details"}},{"value":"Checked with iThenticate","order":0,"name":"screening_status","label":"Screening Status","group":{"name":"plagiarism_screening","label":"Plagiarism Screening"}},{"value":"2010-4-15","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2010-7-12","order":1,"name":"revised","label":"Revised","group":{"name":"publication_history","label":"Publication History"}},{"value":"2010-7-15","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2010-8-17","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}