{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,22]],"date-time":"2025-12-22T12:54:25Z","timestamp":1766408065420},"reference-count":44,"publisher":"Bentham Science Publishers Ltd.","issue":"1","license":[{"start":{"date-parts":[[2010,2,11]],"date-time":"2010-02-11T00:00:00Z","timestamp":1265846400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.5\/"}],"content-domain":{"domain":["openorthopaedicsjournal.com","benthamopen.com"],"crossmark-restriction":true},"short-container-title":["TOORTHJ"],"published-print":{"date-parts":[[2010,2,11]]},"abstract":"<jats:p>The long-term durability of polyethylene lining total hip arthroplasty (THA) mainly depends on periprosthetic osteolysis due to wear particles, especially in young active patients. In hip simulator study, reports revealed significant wear reduction of the alumina ceramic-on-polyethylene articulation of THA compared with metal-on-polyethylene bearing surfaces. However, medium to long-term clinical studies of THA using the alumina ceramic-on-polyethylene are few and the reported wear rate of this articulation is variable. We reviewed the advantages and disadvantages of ceramicon- polyethylene articulation in THA, hip simulator study and retrieval study for polyethylene wear,<jats:italic>in vivo<\/jats:italic>clinical results of THA using alumina ceramic-on-polyethylene bearing surfaces in the literature, and new trial alumina ceramic-onhighly cross linked polyethylene bearing surfaces.<\/jats:p>","DOI":"10.2174\/1874325001004010056","type":"journal-article","created":{"date-parts":[[2010,3,5]],"date-time":"2010-03-05T17:34:17Z","timestamp":1267810457000},"page":"56-60","update-policy":"http:\/\/dx.doi.org\/10.2174\/crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty"],"prefix":"10.2174","volume":"4","author":[{"given":"Jung","family":"Yup Lee","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shin-Yoon","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"965","reference":[{"key":"refR1","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/00003086-199209000-00004","volume":"282","author":"Clarke IC","year":"1992","unstructured":"Clarke IC. Role of ceramic implants. Design and clinical success with total hip prosthetic ceramic-to-ceramic bearings Clin Orthop Relat Res 1992; 282 : 19-30.","journal-title":"Clin Orthop Relat Res"},{"key":"refR2","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1016\/S0142-9612(02)00360-5","volume":"24","author":"Germain MA","year":"2003","unstructured":"Germain MA, Hatton A, Williams S, et al. Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro Biomaterials 2003; 24 (3) : 469-79.","journal-title":"Biomaterials"},{"key":"refR3","first-page":"49","volume":"53","author":"Heisel C","year":"2004","unstructured":"Heisel C, Silva M, Schmalzried TP. Bearing surface options for total hip replacement in young patients Instr Course Lect 2004; 53 : 49-65.","journal-title":"Instr Course Lect"},{"key":"refR4","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1016\/j.arth.2003.12.065","volume":"19","author":"Della Valle AG","year":"2004","unstructured":"Della Valle AG, Doty S, Gradl G, Labissiere A, Nestor BJ. Wear of a highly cross-linked polyethylene liner associated with metallic deposition on a ceramic femoral head J Arthroplasty 2004; 19 (4) : 532-6.","journal-title":"J Arthroplasty"},{"key":"refR5","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1097\/00003086-200010000-00011","volume":"379","author":"Oonishi H","year":"2000","unstructured":"Oonishi H, Wakitani S, Murata N, et al. Clinical experience with ceramics in total hip replacement Clin Orthop Relat Res 2000; 379 : 77-84.","journal-title":"Clin Orthop Relat Res"},{"key":"refR6","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.arth.2004.06.017","volume":"19","author":"Santos EM","year":"2004","unstructured":"Santos EM, Vohra S, Catledge SA, McClenny MD, Lemons J, Moore KD. Examination of surface and material properties of explanted zirconia femoral heads J Arthroplasty 2004; 19 (7 Suppl 2) : 30-4.","journal-title":"J Arthroplasty"},{"key":"refR7","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1007\/s11999-009-1091-4","volume":"468","author":"Hamilton WG","year":"2009","unstructured":"Hamilton WG, McAuley JP, Dennis DA, Murphy JA, Blumenfeld TJ, Politi J. THA with delta ceramic on ceramic: results of a multicenter investigational device exemption trial Clin Orthop Relat Res 2009; 468 : 358-66.","journal-title":"Clin Orthop Relat Res"},{"key":"refR8","doi-asserted-by":"crossref","first-page":"1507","DOI":"10.1016\/S0142-9612(00)00306-9","volume":"22","author":"Saikko V","year":"2001","unstructured":"Saikko V, Ahlroos T, Calonius O, Keranen J. Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon Biomaterials 2001; 22 (12) : 1507-4.","journal-title":"Biomaterials"},{"key":"refR9","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1097\/00003086-200010000-00006","volume":"379","author":"Clarke IC","year":"2000","unstructured":"Clarke IC, Gustafson A. Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear Clin Orthop Relat Res 2000; 379 : 34-40.","journal-title":"Clin Orthop Relat Res"},{"key":"refR10","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/S0883-5403(97)90057-7","volume":"12","author":"Bragdon CR","year":"1997","unstructured":"Bragdon CR, Jasty M, Kawate K, et al. Wear of retrieved cemented polyethylene acetabula with alumina femoral heads J Arthroplasty 1997; 12 (2) : 119-25.","journal-title":"J Arthroplasty"},{"key":"refR11","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1615\/JLongTermEffMedImplants.v12.i1.40","volume":"12","author":"Kusaba A","year":"2002","unstructured":"Kusaba A, Kuroki Y, Kondo S, et al. Frictional torque and wear of retrieved hip prostheses: A comparison between alumina\/PE and Co-Cr\/PE prostheses J Long Term Eff Med Implants 2002; 12 (1) : 53-62.","journal-title":"J Long Term Eff Med Implants"},{"key":"refR12","doi-asserted-by":"crossref","first-page":"1688","DOI":"10.2106\/00004623-200111000-00011","volume":"83-A","author":"Urban JA","year":"2001","unstructured":"Urban JA, Garvin KL, Boese CK, et al. Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results J Bone Joint Surg Am 2001; 83-A (11) : 1688-94.","journal-title":"J Bone Joint Surg Am"},{"key":"refR13","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1302\/0301-620X.85B4.13397","volume":"85","author":"Hernigou P","year":"2003","unstructured":"Hernigou P, Bahrami T. Zirconia and alumina ceramics in comparison with stainless-steel heads. Polyethylene wear after a minimum ten-year follow-up J Bone Joint Surg Br 2003; 85 (4) : 504-9.","journal-title":"J Bone Joint Surg Br"},{"key":"refR14","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1016\/j.arth.2005.01.007","volume":"20","author":"Kim SY","year":"2005","unstructured":"Kim SY, Kim DH, Oh CW, Kim PT, Ihn JC. Total hip arthroplasty with the use of nonmodular cementless acetabular component J Arthroplasty 2005; 20 (5) : 632-8.","journal-title":"J Arthroplasty"},{"key":"refR15","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1302\/0301-620X.87B6.15380","volume":"87","author":"Kim YG","year":"2005","unstructured":"Kim YG, Kim SY, Kim SJ, Park BC, Kim PT, Ihn JC. The use of cementless expansion acetabular component and an alumina-polyethylene bearing in total hip arthroplasty for osteonecrosis J Bone Joint Surg Br 2005; 87 (6) : 776-80.","journal-title":"J Bone Joint Surg Br"},{"key":"refR16","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1097\/00003086-199209000-00011","volume":"282","author":"Zichner LP","year":"1992","unstructured":"Zichner LP, Willert HG. Comparison of alumina-polyethylene and metal-polyethylene in clinical trials Clin Orthop Relat Res 1992; 282 : 86-94.","journal-title":"Clin Orthop Relat Res"},{"key":"refR17","doi-asserted-by":"crossref","first-page":"240","DOI":"10.3109\/17453679008993508","volume":"61","author":"Schuller HM","year":"1990","unstructured":"Schuller HM, Marti RK. Ten-year socket wear in 66 hip arthroplasties. Ceramic versus metal heads Acta Orthop Scand 1990; 61 (3) : 240-3.","journal-title":"Acta Orthop Scand"},{"key":"refR18","doi-asserted-by":"crossref","first-page":"948","DOI":"10.1302\/0301-620X.82B7.9885","volume":"82","author":"Sychterz CJ","year":"2000","unstructured":"Sychterz CJ, Engh CA Jr, Young AM, Hopper RH Jr, Engh CA. Comparison of in vivo wear between polyethylene liners articulating with ceramic and cobalt-chrome femoral heads J Bone Joint Surg Br 2000; 82 (7) : 948-51.","journal-title":"J Bone Joint Surg Br"},{"key":"refR19","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1016\/S0883-5403(03)00193-1","volume":"18","author":"Hasegawa M","year":"2003","unstructured":"Hasegawa M, Sudo A, Hirata H, Uchida A. Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup J Arthroplasty 2003; 18 (5) : 658-1.","journal-title":"J Arthroplasty"},{"key":"refR20","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1007\/s002640100223","volume":"25","author":"Haraguchi K","year":"2001","unstructured":"Haraguchi K, Sugano N, Nishii T, Sakai T, Yoshikawa H, Ohzono K. Influence of polyethylene and femoral head surface quality on wear: a retrieval study Int Orthop 2001; 25 (1) : 29-34.","journal-title":"Int Orthop"},{"key":"refR21","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1302\/0301-620X.78B2.0780280","volume":"78","author":"Wroblewski BM","year":"1996","unstructured":"Wroblewski BM, Siney PD, Dowson D, Collins SN. Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups J Bone Joint Surg Br 1996; 78 (2) : 280-5.","journal-title":"J Bone Joint Surg Br"},{"key":"refR22","doi-asserted-by":"crossref","first-page":"1529","DOI":"10.2106\/00004623-199710000-00010","volume":"79","author":"Livingston BJ","year":"1997","unstructured":"Livingston BJ, Chmell MJ, Spector M, Poss R. Complications of total hip arthroplasty associated with the use of an acetabular component with a Hylamer liner J Bone Joint Surg Am 1997; 79 (10) : 1529-38.","journal-title":"J Bone Joint Surg Am"},{"key":"refR23","doi-asserted-by":"crossref","first-page":"1040","DOI":"10.2106\/00004623-199707000-00010","volume":"79","author":"Sychterz CJ","year":"1997","unstructured":"Sychterz CJ, Engh CA Jr, Shah N, Engh CA Sr. Radiographic evaluation of penetration by the femoral head into the polyethylene liner over time J Bone Joint Surg Am 1997; 79 (7) : 1040-6.","journal-title":"J Bone Joint Surg Am"},{"key":"refR24","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1080\/000164701753532763","volume":"72","author":"Hasegawa M","year":"2001","unstructured":"Hasegawa M, Ohashi T, Tani T. Poor outcome of 44 cemented total hip arthroplasties with alumina ceramic heads: Clinical evaluation and retrieval analysis after 10-16 years Acta Orthop Scand 2001; 72 (5) : 449-56.","journal-title":"Acta Orthop Scand"},{"key":"refR25","doi-asserted-by":"crossref","first-page":"1220","DOI":"10.1302\/0301-620X.87B9.16265","volume":"87","author":"Wroblewski BM","year":"2005","unstructured":"Wroblewski BM, Siney PD, Fleming PA. Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A 17-year follow-up report J Bone Joint Surg Br 2005; 87 (9) : 1220-.","journal-title":"J Bone Joint Surg Br"},{"key":"refR26","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.arth.2006.03.004","volume":"22","author":"Liang B","year":"2007","unstructured":"Liang B, Kawanabe K, Ise K, Iida H, Nakamura T. Polyethylene wear against alumina and zirconia heads in cemented total hip arthroplasty J Arthroplasty 2007; 22 (2) : 251-7.","journal-title":"J Arthroplasty"},{"key":"refR27","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1302\/0301-620X.90B6.20540","volume":"90","author":"Kim YH","year":"2008","unstructured":"Kim YH, Kim JS. Tribological and material analyses of retrieved alumina and zirconia ceramic heads correlated with polyethylene wear after total hip replacement J Bone Joint Surg Br 2008; 90 (6) : 731-.","journal-title":"J Bone Joint Surg Br"},{"key":"refR28","author":"Lewis PM","year":"2009","unstructured":"Lewis PM, Al-Belooshi A, Olsen M, Schemitch EH, Waddell JP. Prospective randomized trial comparing alumina ceramic-on-ceramic with ceramic-on-conventional polyethylene bearings in total hip arthroplasty J Arthroplasty 2009. [Epub ahead of print]","journal-title":"J Arthroplasty"},{"key":"refR29","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1302\/0301-620X.77B4.7615596","volume":"77","author":"Sugano N","year":"1995","unstructured":"Sugano N, Nishii T, Nakata K, Masuhara K, Takaoka K. Polyethylene sockets and alumina ceramic heads in cemented total hip arthroplasty. A ten-year study J Bone Joint Surg Br 1995; 77 (4) : 548-6.","journal-title":"J Bone Joint Surg Br"},{"key":"refR30","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1302\/0301-620X.85B5.13923","volume":"85","author":"Tanaka K","year":"2003","unstructured":"Tanaka K, Tamura J, Kawanabe K, Shimizu M, Nakamura T. Effect of alumina femoral heads on polyethylene wear in cemented total hip arthroplasty. Old versus current alumina J Bone Joint Surg Br 2003; 85 (5) : 655-0.","journal-title":"J Bone Joint Surg Br"},{"key":"refR31","doi-asserted-by":"crossref","first-page":"2274","DOI":"10.1007\/s11999-009-0773-2","volume":"467","author":"Hernigou P","year":"2009","unstructured":"Hernigou P, Zilber S, Filippini P, Poignard A. Ceramic-ceramic bearing decreases osteolysis: A 20-year study versus ceramic-polyethylene on the contralateral hip Clin Orthop Relat Res 2009; 467 (9) : 2274-80.","journal-title":"Clin Orthop Relat Res"},{"key":"refR32","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1016\/S0883-5403(05)80087-7","volume":"10","author":"Callaway GH","year":"1995","unstructured":"Callaway GH, Flynn W, Ranawat CS, Sculco TP. Fracture of the femoral head after ceramic-on-polyethylene total hip arthroplasty J Arthroplasty 1995; 10 (6) : 855-9.","journal-title":"J Arthroplasty"},{"key":"refR33","doi-asserted-by":"crossref","first-page":"848","DOI":"10.1016\/S0883-5403(05)80085-3","volume":"10","author":"Hummer CD 3rd","year":"1995","unstructured":"Hummer CD 3rd, Rothman RH, Hozack WJ. Catastrophic failure of modular zirconia-ceramic femoral head components after total hip arthroplasty J Arthroplasty 1995; 10 (6) : 848-50.","journal-title":"J Arthroplasty"},{"key":"refR34","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1016\/S0883-5403(05)80089-0","volume":"10","author":"Michaud RJ","year":"1995","unstructured":"Michaud RJ, Rashad SY. Spontaneous fracture of the ceramic ball in a ceramic-polyethylene total hip arthroplasty J Arthroplasty 1995; 10 (6) : 863-7.","journal-title":"J Arthroplasty"},{"key":"refR35","doi-asserted-by":"crossref","first-page":"173","DOI":"10.3928\/0147-7447-19980201-11","volume":"21","author":"Willmann G","year":"1998","unstructured":"Willmann G. Ceramics for total hip replacement--what a surgeon should know Orthopedics 1998; 21 (2) : 173-7.","journal-title":"Orthopedics"},{"key":"refR36","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1097\/00003086-200010000-00004","volume":"379","author":"Willmann G","year":"2000","unstructured":"Willmann G. Ceramic femoral head retrieval data Clin Orthop Relat Res 2000; 379 : 22-8.","journal-title":"Clin Orthop Relat Res"},{"key":"refR37","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1097\/00003086-199607000-00021","volume":"328","author":"Fritsch EW","year":"1996","unstructured":"Fritsch EW, Gleitz M. Ceramic femoral head fractures in total hip arthroplasty Clin Orthop Relat Res 1996; 328 : 129-36.","journal-title":"Clin Orthop Relat Res"},{"key":"refR38","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1055\/s-2008-1044744","volume":"125","author":"Heisel J","year":"1987","unstructured":"Heisel J, Schmitt E. Implant fractures in ceramic hip endoprostheses Z Orthop Ihre Grenzgeb 1987; 125 (5) : 480-90.","journal-title":"Z Orthop Ihre Grenzgeb"},{"key":"refR39","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1016\/0142-9612(96)83281-9","volume":"17","author":"Wang A","year":"1996","unstructured":"Wang A, Essner A, Stark C, Dumbleton JH. Comparison of the size and morphology of UHMWPE wear debris produced by a hip joint simulator under serum and water lubricated conditions Biomaterials 1996; 17 (9) : 865-71.","journal-title":"Biomaterials"},{"key":"refR40","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1097\/01.blo.0000096802.78689.45","volume":"417","author":"Digas G","year":"2003","unstructured":"Digas G, Karrholm J, Thanner J, Malchau H, Herberts P. Highly cross-linked polyethylene in cemented THA: Randomized study of 61 hips Clin Orthop Relat Res 2003; 417 : 126-38.","journal-title":"Clin Orthop Relat Res"},{"key":"refR41","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1007\/s11999-009-1154-6","volume":"468","author":"Kelly NH","year":"2010","unstructured":"Kelly NH, Rajadhyaksha AD, Wright TM, Maher SA, Westrich GH. High stresses conditions do not increase wear of thin highly crosslinked UHMWPE Clin Orthop Relat Res 2010; 468 : 418-23.","journal-title":"Clin Orthop Relat Res"},{"key":"refR42","first-page":"1","volume":"29","author":"Callaghan JJ","year":"2009","unstructured":"Callaghan JJ, Liu SS. Ceramic on crosslinked polyethylene in total hip replacement: any better than metal on crosslinked polyethylene? Iowa Orthop J 2009; 29 : 1-4.","journal-title":"Iowa Orthop J"},{"key":"refR43","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.arth.2005.04.026","volume":"20","author":"Holley KG","year":"2005","unstructured":"Holley KG, Furman BD, Babalola OM, Lipman JD, Padgett DE, Wright TM. Impingement of acetabular cups in a hip simulator: comparison of highly cross-linked and conventional polyethylene J Arthroplasty 2005; 20 (7Suppl 3) : 77-86.","journal-title":"J Arthroplasty"},{"key":"refR44","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1016\/j.arth.2008.05.009","volume":"24","author":"Kim YH","year":"2009","unstructured":"Kim YH, Kim JS, Choi YW, Kwon OR. Intermediate results of simultaneous alumina-on-alumina bearing and alumina-on-highly cross-linked polyethylene bearing total hip arthroplasties J Arthroplasty 2009; 24 (6) : 885-91.","journal-title":"J Arthroplasty"}],"container-title":["The Open Orthopaedics Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/openorthopaedicsjournal.com\/contents\/volumes\/V4\/TOORTHJ-4-56\/TOORTHJ-4-56.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/openorthopaedicsjournal.com\/contents\/volumes\/V4\/TOORTHJ-4-56\/TOORTHJ-4-56.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/openorthopaedicsjournal.com\/contents\/volumes\/V4\/TOORTHJ-4-56\/TOORTHJ-4-56.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,30]],"date-time":"2023-05-30T19:45:28Z","timestamp":1685475928000},"score":1,"resource":{"primary":{"URL":"https:\/\/openorthopaedicsjournal.com\/VOLUME\/4\/PAGE\/56\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,2,11]]},"references-count":44,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2010,2,11]]}},"alternative-id":["TOORTHJ-4-56"],"URL":"https:\/\/doi.org\/10.2174\/1874325001004010056","relation":{},"ISSN":["1874-3250"],"issn-type":[{"value":"1874-3250","type":"print"}],"subject":[],"published":{"date-parts":[[2010,2,11]]},"assertion":[{"value":"Peer Reviewed","order":0,"name":"review_status","label":"Review Status","group":{"name":"peer_review_details","label":"Peer Review Details"}},{"value":"Single blind","order":1,"name":"review_process","label":"Review Process","group":{"name":"peer_review_details","label":"Peer Review Details"}},{"value":"Checked with iThenticate","order":0,"name":"screening_status","label":"Screening Status","group":{"name":"plagiarism_screening","label":"Plagiarism Screening"}},{"value":"2009-10-1","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2009-11-17","order":1,"name":"revised","label":"Revised","group":{"name":"publication_history","label":"Publication History"}},{"value":"2010-1-5","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2010-2-11","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}