{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T06:26:13Z","timestamp":1773296773625,"version":"3.50.1"},"reference-count":37,"publisher":"Bentham Science Publishers Ltd.","issue":"1","license":[{"start":{"date-parts":[[2016,3,22]],"date-time":"2016-03-22T00:00:00Z","timestamp":1458604800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["openorthopaedicsjournal.com","benthamopen.com"],"crossmark-restriction":true},"short-container-title":["TOORTHJ"],"published-print":{"date-parts":[[2016,3,22]]},"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>In cementless total hip arthroplasty, imageless computer-assisted navigation is usually used to register the anterior pelvic plane (APP). The accuracy of this method is influenced by the subcutaneous tissues overlying the registration landmarks. On the other hand, the acetabular center axis (ACA) is determined from the acetabular rim. Precise registration of the ACA is possible because of direct palpation using a pointer. Imageless navigation using the ACA usually targets patients with normal acetabular morphology. The aim of this study was to investigate the accuracy of imageless navigation using the ACA instead of the APP in patients with normal or deformed acetabular rims.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The intraoperative cup position was compared with that obtained from the postoperative computed tomography (CT) images in 18 cases.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The inclination angle derived from the navigation system was 3.4 \u00b1 5.3 degrees smaller and the anteversion angle was 1.4 \u00b1 3.1 degrees larger than those derived from the CT images.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The inclination cup angle of the navigation system was significantly inferior to the true value, particularly in cases with large anterior osteophytes.<\/jats:p><\/jats:sec>","DOI":"10.2174\/1874325001610010026","type":"journal-article","created":{"date-parts":[[2016,3,24]],"date-time":"2016-03-24T04:38:47Z","timestamp":1458794327000},"page":"26-35","update-policy":"https:\/\/doi.org\/10.2174\/crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Initial Results of an Acetabular Center Axis Registration Technique in Navigated Hip Arthroplasty with Deformed Acetabular Rims"],"prefix":"10.2174","volume":"10","author":[{"given":"Hiroshi","family":"Wada","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hajime","family":"Mishima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomohiro","family":"Yoshizawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hisashi","family":"Sugaya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomofumi","family":"Nishino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masashi","family":"Yamazaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"965","reference":[{"key":"refR1","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1302\/0301-620X.88B2.17163","volume":"88","author":"Kalteis T.","year":"2006","unstructured":"Kalteis T, Handel M, B\u00e4this H, Perlick L, Tingart M, Grifka J. Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation? J Bone Joint Surg Br 2006; 88 (2) : 163-7.","journal-title":"J. Bone Joint Surg. Br."},{"key":"refR2","doi-asserted-by":"publisher","first-page":"1432","DOI":"10.1016\/j.arth.2010.11.011","volume":"26","author":"Moskal J.T.","year":"2011","unstructured":"Moskal JT, Capps SG. Acetabular component positioning in total hip arthroplasty: an evidence-based analysis. J Arthroplasty 2011; 26 (8) : 1432-7.","journal-title":"J. Arthroplasty"},{"key":"refR3","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1007\/s00264-010-1042-4","volume":"35","author":"Sendtner E.","year":"2011","unstructured":"Sendtner E, Schuster T, W\u00f6rner M, Kalteis T, Grifka J, Renkawitz T. Accuracy of acetabular cup placement in computer-assisted, minimally-invasive THR in a lateral decubitus position. Int Orthop 2011; 35 (6) : 809-15.","journal-title":"Int. Orthop."},{"key":"refR4","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1016\/j.arth.2005.04.024","volume":"20","author":"Wixson R.L.","year":"2005","unstructured":"Wixson RL, MacDonald MA. Total hip arthroplasty through a minimal posterior approach using imageless computer-assisted hip navigation. J Arthroplasty 2005; 20 (7) (Suppl. 3) : 51-6.","journal-title":"J. Arthroplasty"},{"key":"refR5","doi-asserted-by":"publisher","first-page":"1401","DOI":"10.1302\/0301-620X.88B10.17587","volume":"88","author":"Honl M.","year":"2006","unstructured":"Honl M, Schwieger K, Salineros M, Jacobs J, Morlock M, Wimmer M. Orientation of the acetabular component. A comparison of five navigation systems with conventional surgical technique. J Bone Joint Surg Br 2006; 88 (10) : 1401-5.","journal-title":"J. Bone Joint Surg. Br."},{"key":"refR6","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1007\/s00264-007-0479-6","volume":"33","author":"Jenny J.Y.","year":"2009","unstructured":"Jenny JY, Boeri C, Dosch JC, Uscatu M, Ciobanu E. Navigated non-image-based positioning of the acetabulum during total hip replacement. Int Orthop 2009; 33 (1) : 83-7.","journal-title":"Int. Orthop."},{"key":"refR7","doi-asserted-by":"publisher","first-page":"38","DOI":"10.3928\/01477447-20100510-61","volume":"33","author":"Fukui T.","year":"2010","unstructured":"Fukui T, Fukunishi S, Nishio S, Shibanuma N, Yoshiya S. Use of image-free navigation in determination of acetabular cup orientation: analysis of factors affecting precision. Orthopedics 2010; 33 (10 Suppl.) : 38-42.","journal-title":"Orthopedics"},{"key":"refR8","doi-asserted-by":"publisher","first-page":"13","DOI":"10.3928\/01477447-20120919-52","volume":"35","author":"Kim T.H.","year":"2012","unstructured":"Kim TH, Lee SH, Yang JH, Oh KJ. Computed tomography assessment of image-free navigation-assisted cup placement in THA in an Asian population. Orthopedics 2012; 35 (10 Suppl.) : 13-7.","journal-title":"Orthopedics"},{"key":"refR9","doi-asserted-by":"publisher","first-page":"494","DOI":"10.2106\/JBJS.F.00529","volume":"89","author":"Parratte S.","year":"2007","unstructured":"Parratte S, Argenson JN. Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty. A prospective, randomized, controlled study. J Bone Joint Surg Am 2007; 89 (3) : 494-9.","journal-title":"J. Bone Joint Surg. Am."},{"key":"refR10","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1016\/j.arth.2011.06.038","volume":"27","author":"Wassilew G.I.","year":"2012","unstructured":"Wassilew GI, Perka C, Janz V, K\u00f6nig C, Asbach P, Hasart O. Use of an ultrasound-based navigation system for an accurate acetabular positioning in total hip arthroplasty: a prospective, randomized, controlled study. J Arthroplasty 2012; 27 (5) : 687-94.","journal-title":"J. Arthroplasty"},{"key":"refR11","doi-asserted-by":"publisher","first-page":"S35","DOI":"10.1007\/s00264-007-0430-x","volume":"31","author":"Ybinger T.","year":"2007","unstructured":"Ybinger T, Kumpan W. Enhanced acetabular component positioning through computer-assisted navigation. Int Orthop 2007; 31 (Suppl. 1) : S35-8.","journal-title":"Int. Orthop."},{"key":"refR12","doi-asserted-by":"publisher","first-page":"812","DOI":"10.1016\/j.arth.2006.10.001","volume":"22","author":"Ybinger T.","year":"2007","unstructured":"Ybinger T, Kumpan W, Hoffart HE, Muschalik B, Bullmann W, Zweym\u00fcller K. Accuracy of navigation-assisted acetabular component positioning studied by computed tomography measurements: methods and results. J Arthroplasty 2007; 22 (6) : 812-7.","journal-title":"J. Arthroplasty"},{"key":"refR13","doi-asserted-by":"publisher","first-page":"43","DOI":"10.3928\/01477447-20100510-52","volume":"33","author":"Hakki S.","year":"2010","unstructured":"Hakki S, Bilotta V, Oliveira JD, Dordelly L. Acetabular center axis: is it the future of hip navigation? Orthopedics 2010; 33 (10 Suppl.) : 43-7.","journal-title":"Orthopedics"},{"key":"refR14","first-page":"27","volume":"31","author":"Hakki S.","year":"2008","unstructured":"Hakki S, Dordelly L, Oliveira D. Comparative study of acetabular center axis vs anterior pelvic plane registration technique in navigated hip arthroplasty. Orthopedics 2008; 31 (10 Suppl. 1) : 27-30.","journal-title":"Orthopedics"},{"key":"refR15","doi-asserted-by":"publisher","first-page":"700","DOI":"10.5301\/HIP.2011.8860","volume":"21","author":"Carcangiu A.","year":"2011","unstructured":"Carcangiu A, D\u2019Arrigo C, Topa D, et al. Reliability of cup position in navigated THA in the lateral decubitus position using the \u2018flip technique\u2019. Hip Int 2011; 21 (6) : 700-5.","journal-title":"Hip Int."},{"key":"refR16","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1097\/BLO.0b013e3181560c51","volume":"465","author":"Dorr L.D.","year":"2007","unstructured":"Dorr LD, Malik A, Wan Z, Long WT, Harris M. Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position. Clin Orthop Relat Res 2007; 465 (465) : 92-9.","journal-title":"Clin. Orthop. Relat. Res."},{"key":"refR17","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1186\/1749-799X-6-40","volume":"6","author":"Hohmann E.","year":"2011","unstructured":"Hohmann E, Bryant A, Tetsworth K. Accuracy of acetabular cup positioning using imageless navigation. J Orthop Surg 2011; 6 : 40.","journal-title":"J. Orthop. Surg."},{"key":"refR18","doi-asserted-by":"crossref","first-page":"15","DOI":"10.2106\/00004623-197961010-00004","volume":"61","author":"Crowe J.F.","year":"1979","unstructured":"Crowe JF, Mani VJ, Ranawat CS. Total hip replacement in congenital dislocation and dysplasia of the hip. J Bone Joint Surg Am 1979; 61 (1) : 15-23.","journal-title":"J. Bone Joint Surg. Am."},{"key":"refR19","doi-asserted-by":"publisher","first-page":"925","DOI":"10.1007\/s00256-013-1574-y","volume":"42","author":"Laborie L.B.","year":"2013","unstructured":"Laborie LB, Enges\u00e6ter IO, Lehmann TG, et al. Radiographic measurements of hip dysplasia at skeletal maturity-new reference intervals based on 2,038 19-year-old Norwegians. Skeletal Radiol 2013; 42 (7) : 925-35.","journal-title":"Skeletal Radiol."},{"key":"refR20","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1302\/0301-620X.81B2.8291","volume":"81","author":"Reynolds D.","year":"1999","unstructured":"Reynolds D, Lucas J, Klaue K. Retroversion of the acetabulum. A cause of hip pain. J Bone Joint Surg Br 1999; 81 (2) : 281-8.","journal-title":"J. Bone Joint Surg. Br."},{"key":"refR21","doi-asserted-by":"crossref","first-page":"217","DOI":"10.2106\/00004623-197860020-00014","volume":"60","author":"Lewinnek G.E.","year":"1978","unstructured":"Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 1978; 60 (2) : 217-20.","journal-title":"J. Bone Joint Surg. Am."},{"key":"refR22","doi-asserted-by":"publisher","first-page":"1271","DOI":"10.1007\/s11999-012-2700-1","volume":"471","author":"Imai N.","year":"2013","unstructured":"Imai N, Ito T, Suda K, Miyasaka D, Endo N. Pelvic flexion measurement from lateral projection radiographs is clinically reliable. Clin Orthop Relat Res 2013; 471 (4) : 1271-6.","journal-title":"Clin. Orthop. Relat. Res."},{"key":"refR23","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1302\/0301-620X.75B2.8444942","volume":"75","author":"Murray D.W.","year":"1993","unstructured":"Murray DW. The definition and measurement of acetabular orientation. J Bone Joint Surg Br 1993; 75 (2) : 228-32.","journal-title":"J. Bone Joint Surg. Br."},{"key":"refR24","doi-asserted-by":"publisher","first-page":"2827","DOI":"10.1007\/s11999-012-2370-z","volume":"470","author":"Fujii M.","year":"2012","unstructured":"Fujii M, Nakashima Y, Sato T, Akiyama M, Iwamoto Y. Acetabular tilt correlates with acetabular version and coverage in hip dysplasia. Clin Orthop Relat Res 2012; 470 (10) : 2827-35.","journal-title":"Clin. Orthop. Relat. Res."},{"key":"refR25","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1016\/S0883-5403(98)90052-3","volume":"13","author":"Kennedy J.G.","year":"1998","unstructured":"Kennedy JG, Rogers WB, Soffe KE, Sullivan RJ, Griffen DG, Sheehan LJ. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty 1998; 13 (5) : 530-4.","journal-title":"J. Arthroplasty"},{"key":"refR26","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1016\/j.orthres.2003.11.001","volume":"22","author":"Widmer K.H.","year":"2004","unstructured":"Widmer KH, Zurfluh B. Compliant positioning of total hip components for optimal range of motion. J Orthop Res 2004; 22 (4) : 815-21.","journal-title":"J. Orthop. Res."},{"key":"refR27","first-page":"159","author":"McCollum D.E.","year":"1990","unstructured":"McCollum DE, Gray WJ. Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop Relat Res 1990; (261): 159-70.","journal-title":"Clin. Orthop. Relat. Res."},{"key":"refR28","doi-asserted-by":"publisher","first-page":"762","DOI":"10.1302\/0301-620X.87B6.14745","volume":"87","author":"Biedermann R.","year":"2005","unstructured":"Biedermann R, Tonin A, Krismer M, Rachbauer F, Eibl G, St\u00f6ckl B. Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component. J Bone Joint Surg Br 2005; 87 (6) : 762-9.","journal-title":"J. Bone Joint Surg. Br."},{"key":"refR29","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1016\/0883-5403(92)90008-E","volume":"7","author":"Garc\u00eda-Cimbrelo E.","year":"1992","unstructured":"Garc\u00eda-Cimbrelo E, Munuera L. Dislocation in low-friction arthroplasty. J Arthroplasty 1992; 7 (2) : 149-55.","journal-title":"J. Arthroplasty"},{"key":"refR30","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1007\/s11999-007-0062-x","volume":"466","author":"Vandenbussche E.","year":"2008","unstructured":"Vandenbussche E, Saffarini M, Taillieu F, Mutschler C. The asymmetric profile of the acetabulum. Clin Orthop Relat Res 2008; 466 (2) : 417-23.","journal-title":"Clin. Orthop. Relat. Res."},{"key":"refR31","doi-asserted-by":"publisher","first-page":"2143","DOI":"10.1007\/s11999-010-1347-z","volume":"468","author":"Cobb J.","year":"2010","unstructured":"Cobb J, Logishetty K, Davda K, Iranpour F. Cams and pincer impingement are distinct, not mixed: the acetabular pathomorphology of femoroacetabular impingement. Clin Orthop Relat Res 2010; 468 (8) : 2143-51.","journal-title":"Clin. Orthop. Relat. Res."},{"key":"refR32","doi-asserted-by":"publisher","first-page":"682","DOI":"10.1007\/s11999-008-0682-9","volume":"467","author":"K\u00f6hnlein W.","year":"2009","unstructured":"K\u00f6hnlein W, Ganz R, Impellizzeri FM, Leunig M. Acetabular morphology: implications for joint-preserving surgery. Clin Orthop Relat Res 2009; 467 (3) : 682-91.","journal-title":"Clin. Orthop. Relat. Res."},{"key":"refR33","doi-asserted-by":"publisher","first-page":"87","DOI":"10.3109\/10929080500229447","volume":"10","author":"Richolt J.A.","year":"2005","unstructured":"Richolt JA, Effenberger H, Rittmeister ME. How does soft tissue distribution affect anteversion accuracy of the palpation procedure in image-free acetabular cup navigation? An ultrasonographic assessment. Comput Aided Surg 2005; 10 (2) : 87-92.","journal-title":"Comput. Aided Surg."},{"key":"refR34","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1054\/arth.2002.30411","volume":"17","author":"Digioia A.M.","year":"2002","unstructured":"Digioia AM III, Jaramaz B, Plakseychuk AY, et al. Comparison of a mechanical acetabular alignment guide with computer placement of the socket. J Arthroplasty 2002; 17 (3) : 359-64.","journal-title":"J. Arthroplasty"},{"key":"refR35","doi-asserted-by":"crossref","first-page":"10","DOI":"10.3928\/01477447-20110525-13","volume":"31","author":"Fukunishi S.","year":"2008","unstructured":"Fukunishi S, Fukui T, Imamura F, Nishio S. Assessment of accuracy of acetabular cup orientation in CT-free navigated total hip arthroplasty. Orthopedics 2008; 31 (10) : 10.","journal-title":"Orthopedics"},{"key":"refR36","doi-asserted-by":"publisher","first-page":"e33","DOI":"10.4081\/or.2012.e33","volume":"4","author":"Fukunishi S.","year":"2012","unstructured":"Fukunishi S, Fukui T, Nishio S, Fujihara Y, Okahisa S, Yoshiya S. Combined anteversion of the total hip arthroplasty implanted with image-free cup navigation and without stem navigation. Orthop Rev (Pavia) 2012; 4 (4) : e33.","journal-title":"Orthop. Rev. (Pavia)"},{"key":"refR37","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1007\/s00776-011-0025-7","volume":"16","author":"Jingushi S.","year":"2011","unstructured":"Jingushi S, Ohfuji S, Sofue M, et al. Osteoarthritis hip joints in Japan: involvement of acetabular dysplasia. J Orthop Sci 2011; 16 (2) : 156-64.","journal-title":"J. Orthop. Sci."}],"container-title":["The Open Orthopaedics Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/openorthopaedicsjournal.com\/contents\/volumes\/V10\/TOORTHJ-10-26\/TOORTHJ-10-26.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/openorthopaedicsjournal.com\/contents\/volumes\/V10\/TOORTHJ-10-26\/TOORTHJ-10-26.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/openorthopaedicsjournal.com\/contents\/volumes\/V10\/TOORTHJ-10-26\/TOORTHJ-10-26.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,16]],"date-time":"2022-06-16T03:01:19Z","timestamp":1655348479000},"score":1,"resource":{"primary":{"URL":"https:\/\/openorthopaedicsjournal.com\/VOLUME\/10\/PAGE\/26\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,3,22]]},"references-count":37,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2016,3,22]]}},"alternative-id":["TOORTHJ-10-26"],"URL":"https:\/\/doi.org\/10.2174\/1874325001610010026","relation":{},"ISSN":["1874-3250"],"issn-type":[{"value":"1874-3250","type":"print"}],"subject":[],"published":{"date-parts":[[2016,3,22]]},"assertion":[{"value":"Peer Reviewed","order":0,"name":"review_status","label":"Review Status","group":{"name":"peer_review_details","label":"Peer Review Details"}},{"value":"Single blind","order":1,"name":"review_process","label":"Review Process","group":{"name":"peer_review_details","label":"Peer Review Details"}},{"value":"Checked with iThenticate","order":0,"name":"screening_status","label":"Screening Status","group":{"name":"plagiarism_screening","label":"Plagiarism Screening"}},{"value":"2015-7-2","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2015-12-4","order":1,"name":"revised","label":"Revised","group":{"name":"publication_history","label":"Publication History"}},{"value":"2015-12-7","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2016-3-22","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}