{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T15:59:36Z","timestamp":1740153576559,"version":"3.37.3"},"reference-count":15,"publisher":"Bentham Science Publishers Ltd.","issue":"2","funder":[{"DOI":"10.13039\/501100018764","name":"Semnan University of Medical Sciences","doi-asserted-by":"publisher","award":["1739"],"award-info":[{"award-number":["1739"]}],"id":[{"id":"10.13039\/501100018764","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["eurekaselect.com"],"crossmark-restriction":true},"short-container-title":["CRP"],"published-print":{"date-parts":[[2022,3]]},"abstract":"<jats:sec>\n<jats:title>Introduction:<\/jats:title>\n<jats:p>In myocardial perfusion imaging, reducing the number of photons in images\nof obese patients causes poor image quality. To solve this problem, we need to inject the tracer\naccording to the patients' weight. Therefore, this study aimed to investigate the relationship between\nmyocardial photon counts with patients' weight, BMI, and gender.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Materials and Methods:<\/jats:title>\n<jats:p>A total of 129 patients underwent myocardial perfusion imaging in a twoday\nstress-first protocol, but only rest images were included in this study. Multiplication factor\nwas used to determine the amount of\nradiopharmaceutical activity injected into the patients. For evaluating the effect of gender, the photon\ncounts of 22 female patients were also assessed when the breast tissue was pulled upward\n(Breast Up). The total myocardial detector counts in the raw images were calculated from the summation\nof 32 projections. A multiple linear regression test was used to simultaneously examine the\neffects of weight, BMI, and gender on photon counts.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Results:<\/jats:title>\n<jats:p>There was no significant relationship between photon counts and patients' weight\n(p=0.129) and BMI (0.406), but gender had significant effects on photon counts, and myocardial\ndetector counts were found to be higher in males (p=0.00). There was a statistically significant difference\nbetween the images of Breast Up and Non-Breast Up, and myocardial detector counts were\nhigher in the Breast Up imaging method (p=0.00).<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Conclusion:<\/jats:title>\n<jats:p>Using the bodyweight formula, the image quality was comparable in obese and lean\npatients, but myocardial detector counts were lower in females, and this formula needs to be adjusted\naccording to the patient's gender.<\/jats:p>\n<\/jats:sec>","DOI":"10.2174\/1874471014666210426112933","type":"journal-article","created":{"date-parts":[[2021,4,27]],"date-time":"2021-04-27T04:42:32Z","timestamp":1619498552000},"page":"117-122","update-policy":"https:\/\/doi.org\/10.2174\/bsp_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Assessment Relation of Myocardial Detector Counts and Administered Activity\nof 99mTc-SestaMIBI in MPI: The Effects of Body Weight, BMI, and\nGender"],"prefix":"10.2174","volume":"15","author":[{"given":"Mohammad Ali","family":"Tajik-Mansoury","sequence":"first","affiliation":[{"name":"Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran"},{"name":"Raaheaseman Center of Nuclear\nMedicine, Semnan University of Medical Science, Semnan, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3015-4532","authenticated-orcid":true,"given":"Mahdi","family":"Mazinani","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mahsa","family":"Sabour","sequence":"additional","affiliation":[{"name":"Raaheaseman Center of Nuclear\nMedicine, Semnan University of Medical Science, Semnan, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Majid","family":"Jadidi","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Milad","family":"Peer- Firozjaei","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nader","family":"Asadian","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran"},{"name":"Raaheaseman Center of Nuclear\nMedicine, Semnan University of Medical Science, Semnan, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"965","reference":[{"key":"ref=1","author":"Cardiology N.","year":"2016","unstructured":"Cardiology N.;  IAEA Human Health Series No 23 (rev 1) 2016","journal-title":"IAEA Human Health Series No 23 (rev 1)"},{"key":"ref=2","doi-asserted-by":"publisher","first-page":"606","DOI":"10.1007\/s12350-015-0387-x","volume":"23","author":"Henzlova M.J.","year":"2016","unstructured":"Henzlova M.J.; Duvall W.L.; Einstein A.J.; Travin M.I.; Verberne H.J.; ASNC imaging guidelines for SPECT nuclear cardiology procedures: Stress, protocols, and tracers. J Nucl Cardiol 2016,23(3),606-639","journal-title":"J Nucl Cardiol"},{"key":"ref=3","doi-asserted-by":"publisher","first-page":"1929","DOI":"10.1007\/s00259-015-3139-x","volume":"42","author":"Verberne H.J.","year":"2015","unstructured":"Verberne H.J.; Acampa W.; Anagnostopoulos C.; Ballinger J.; Bengel F.; De Bondt P.; Buechel R.R.; Cuocolo A.; van Eck-Smit B.L.; Flotats A.; Hacker M.; Hindorf C.; Kaufmann P.A.; Lindner O.; Ljungberg M.; Lonsdale M.; Manrique A.; Minarik D.; Scholte A.J.; Slart R.H.; Tr\u00e4g\u00e5rdh E.; de Wit T.C.; Hesse B.; EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT\/CT: 2015 revision. Eur J Nucl Med Mol Imaging 2015,42(12),1929-1940","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"ref=4","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1097\/00006231-200301000-00015","volume":"24","author":"Notghi A.","year":"2003","unstructured":"Notghi A.; Williams N.; Smith N.; Goyle S.; Harding L.K.; Relationship between myocardial counts and patient weight: Adjusting the injected activity in myocardial perfusion scans. Nucl Med Commun 2003,24(1),55-59","journal-title":"Nucl Med Commun"},{"key":"ref=5","doi-asserted-by":"publisher","first-page":"304","DOI":"10.1016\/S1071-3581(98)90132-5","volume":"5","author":"O\u2019Connor M.K.","year":"1998","unstructured":"O\u2019Connor M.K.; Bothun E.; Gibbons R.J.; Influence of patient height and weight and type of stress on myocardial count density during SPECT imaging with thallium-201 and technetium 99m-sestamibi. J Nucl Cardiol 1998,5(3),304-312","journal-title":"J Nucl Cardiol"},{"key":"ref=6","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.ejmp.2019.11.011","volume":"68","author":"Papanastasiou E.","year":"2019","unstructured":"Papanastasiou E.; Theodoridou E.; Doumas A.; Gerasimou G.; Siountas A.; A study on the optimization of the administered activity in myocardial perfusion SPECT imaging with Tc-99m according to body measurements. Phys Med 2019,68,69-74","journal-title":"Phys Med"},{"key":"ref=7","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1097\/MNM.0b013e328342e9d9","volume":"32","author":"Taylor J.C.","year":"2011","unstructured":"Taylor J.C.; Froberg S-A.; Hillel P.G.; Harris A.M.; Tindale W.B.; Correlation of left ventricular count rate with patient weight in Tc-99m myocardial perfusion imaging. Nucl Med Commun 2011,32(4),279-283","journal-title":"Nucl Med Commun"},{"key":"ref=8","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1007\/s12350-015-0246-9","volume":"23","author":"van Dijk J.D.","year":"2016","unstructured":"van Dijk J.D.; Jager P.L.; Ottervanger J.P.; de Boer J.; Oostdijk A.H.; Engbers E.M.; Slump C.H.; Knollema S.; van Dalen J.A.; Development and validation of a patient-tailored dose regime in myocardial perfusion imaging using conventional SPECT. J Nucl Cardiol 2016,23(1),134-142","journal-title":"J Nucl Cardiol"},{"key":"ref=9","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1007\/s12350-015-0286-1","volume":"23","author":"van Dijk J.D.","year":"2016","unstructured":"van Dijk J.D.; Jager P.L.; Ottervanger J.P.; Slump C.H.; Knollema S.; van Dalen J.A.; Patient-specific tracer activity in MPI SPECT: A hands-on approach. J Nucl Cardiol 2016,23(1),145-148","journal-title":"J Nucl Cardiol"},{"key":"ref=10","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1186\/s13550-016-0250-3","volume":"7","author":"Wickham F.","year":"2017","unstructured":"Wickham F.; McMeekin H.; Burniston M.; McCool D.; Pencharz D.; Skillen A.; Wagner T.; Patient-specific optimisation of administered activity and acquisition times for F-FDG PET imaging. EJNMMI Res 2017,7(1),3","journal-title":"EJNMMI Res"},{"key":"ref=11","first-page":"527","volume":"5","author":"Karakatsanis N.A.","year":"2015","unstructured":"Karakatsanis N.A.; Fokou E.; Tsoumpas C.; Dosage optimization in positron emission tomography: State-of-the-art methods and future prospects. Am J Nucl Med Mol Imaging 2015,5(5),527-547","journal-title":"Am J Nucl Med Mol Imaging"},{"key":"ref=12","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.nuclcard.2006.12.144","volume":"14","author":"Garcia E.V.","year":"2007","unstructured":"Garcia E.V.; SPECT attenuation correction: An essential tool to realize nuclear cardiology\u2019s manifest destiny. J Nucl Cardiol 2007,14(1),16-24","journal-title":"J Nucl Cardiol"},{"key":"ref=13","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1016\/j.ejrnm.2016.05.006","volume":"47","author":"Raza H.","year":"2016","unstructured":"Raza H.; Jadoon L.K.; Mushtaq S.; Jabeen A.; Maqbool M.; Ain M.U.; Ahmed B.; Memon M.A.; Comparison of non-attenuation corrected and attenuation corrected myocardial perfusion SPECT. Egyptian J Radiolo Nucl Med 2016,47,783-792","journal-title":"Egyptian J Radiolo Nucl Med"},{"key":"ref=14","doi-asserted-by":"publisher","first-page":"e1923","DOI":"10.32113\/wcrj_20213_1923","volume":"8","author":"Sadeghipour Vojdani F.","year":"2021","unstructured":"Sadeghipour Vojdani F.; Agha-Alinejad H.; Molanouri Shamsi M.; Soudi S.; Aerobic interval training modulates the systemic inflammation and metastasis in breast cancer. World Cancer Res J 2021,8,e1923","journal-title":"World Cancer Res J"},{"key":"ref=15","doi-asserted-by":"publisher","DOI":"10.1007\/s12350-016-0636-7","author":"Kim D.A.","year":"2017","unstructured":"Kim D.A.; Farrell M.B.; Jerome S.D.;  It\u2019s about time we think about lowering radiation dose in obese patients too 2017","journal-title":"It\u2019s about time we think about lowering radiation dose in obese patients too"}],"container-title":["Current Radiopharmaceuticals"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.eurekaselect.com\/article\/download?doi=10.2174\/1874471014666210426112933","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.eurekaselect.com\/193022\/article","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.eurekaselect.com\/article\/download?doi=10.2174\/1874471014666210426112933","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,27]],"date-time":"2022-10-27T16:31:49Z","timestamp":1666888309000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.eurekaselect.com\/193022\/article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3]]},"references-count":15,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022,3]]}},"alternative-id":["LiveAll1"],"URL":"https:\/\/doi.org\/10.2174\/1874471014666210426112933","relation":{},"ISSN":["1874-4710"],"issn-type":[{"type":"print","value":"1874-4710"}],"subject":[],"published":{"date-parts":[[2022,3]]},"assertion":[{"value":"Peer Reviewed","order":0,"name":"review_status","label":"Review Status","group":{"name":"peer_review_details","label":"Peer Review Details"}},{"value":"Single blind","order":1,"name":"review_process","label":"Review Process","group":{"name":"peer_review_details","label":"Peer Review Details"}},{"value":"Checked with iThenticate","order":0,"name":"screening_status","label":"Screening Status","group":{"name":"plagiarism_screening","label":"Plagiarism Screening"}},{"value":"2020-12-30","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-03-15","order":1,"name":"revised","label":"Revised","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-03-16","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-04-27","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}