{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T00:09:43Z","timestamp":1769126983016,"version":"3.49.0"},"reference-count":15,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2012,11,1]],"date-time":"2012-11-01T00:00:00Z","timestamp":1351728000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Water Environment Research"],"published-print":{"date-parts":[[2012,11]]},"abstract":"<jats:p>Several methods exist for the measurement of cyanide levels in treated wastewater,typically requiring preservation of the sample with sodium hydroxide to minimize loss of hydrogen cyanide gas (HCN). Recent reports have shown that cyanide levels may increase with chlorination or preservation. In this study, three flow injection analysis methods involving colorimetric and amperometric detection were compared within one laboratory, as well as across separate laboratories and equipment. Split wastewater samples from eight facilities and three different sampling periods were tested. An interlaboratory confidence interval of 3.5 ppb was calculated compared with the intralaboratory reporting limit of 2 ppb. The results show that free cyanide measurements are not statistically different than total cyanide levels. An artificial increase in cyanide level is observed with all methods for preserved samples relative to nonpreserved samples, with an average increase of 2.3 ppb. The possible loss of cyanide without preservation is shown to be statistically insignificant if properly stored up to 48 hours. The cyanide increase with preservation is further substantiated with the method of standard additions and is not a matrix interference. The increase appears to be correlated with the amount of cyanide observed without preservation, which appears to be greater in those facilities that disinfect their wastewater with chlorine, followed by dechlorination with sodium bisulfite.<\/jats:p>","DOI":"10.2175\/106143012x13373550426995","type":"journal-article","created":{"date-parts":[[2012,11,5]],"date-time":"2012-11-05T12:53:01Z","timestamp":1352119981000},"page":"2010-2016","source":"Crossref","is-referenced-by-count":5,"title":["Interlaboratory Study of Free Cyanide Methods Compared to Total Cyanide Measurements and the Effect of Preservation with Sodium Hydroxide for Secondary\u2010 and Tertiary\u2010Treated Waste Water Samples"],"prefix":"10.1002","volume":"84","author":[{"given":"Brett J.","family":"Stanley","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karen","family":"Antonio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2012,11]]},"reference":[{"key":"e_1_2_6_2_1","volume-title":"Standard Methods for the Examination of Water and Wastewater","author":"American Public Health Association; American Water Works Association; Water Environment Federation","year":"2012"},{"key":"e_1_2_6_3_1","volume-title":"1998 Annual Book of ASTM Standards","author":"ASTM","year":"1998"},{"key":"e_1_2_6_4_1","volume-title":"Designation: D 7237\u201006","author":"ASTM International","year":"2007"},{"key":"e_1_2_6_5_1","volume-title":"Designation: D 4841\u201088","author":"ASTM International","year":"2008"},{"key":"e_1_2_6_6_1","volume-title":"Digestion and Distillation of Total Cyanide in Drinking and Wastewaters Using Micro Dist and Determination of Cyanide by Flow Injection Analysis; QuikChem Method 10\u2010204\u201000\u20101\u2010X","author":"Bogren K.","year":"2007"},{"key":"e_1_2_6_7_1","doi-asserted-by":"crossref","first-page":"01543","DOI":"10.1016\/S0043-1354(95)00304-5","article-title":"Wastewater Derived Interferences in Cyanide Analysis","volume":"31","author":"Carr S. A.","year":"1997","journal-title":"Water. Res."},{"key":"e_1_2_6_8_1","volume-title":"Water Environment Research Foundation Final Report, 01\u2010ECO\u20101, Section 2.2","author":"Gensemer R. W.","year":"2007"},{"key":"e_1_2_6_9_1","volume-title":"Nondetects and Data Analysis","author":"Helsel D.","year":"2005"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.2175\/106143007X220743"},{"key":"e_1_2_6_11_1","volume-title":"Proceedings of the 79th Annual Water Environment Federation Technical Exhibition and Conference [CD\u2010ROM]; Dallas, Texas, Oct 10\u201313","author":"Pandit A.","year":"2006"},{"key":"e_1_2_6_12_1","volume-title":"Environmental Monitoring Systems Laboratory Office of Research and Development","author":"U.S. Environmental Protection Agency","year":"1993"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.2175\/106143004X141627"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.2175\/106143004X141735"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.2175\/106143004X141744"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.2175\/106143004X141636"}],"container-title":["Water Environment Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.2175\/106143012X13373550426995","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T17:00:04Z","timestamp":1694797204000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.2175\/106143012X13373550426995"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,11]]},"references-count":15,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2012,11]]}},"alternative-id":["10.2175\/106143012X13373550426995"],"URL":"https:\/\/doi.org\/10.2175\/106143012x13373550426995","archive":["Portico"],"relation":{},"ISSN":["1061-4303","1554-7531"],"issn-type":[{"value":"1061-4303","type":"print"},{"value":"1554-7531","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,11]]}}}