{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,5,21]],"date-time":"2023-05-21T04:39:58Z","timestamp":1684643998808},"reference-count":23,"publisher":"Japan Neurosurgical Society","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Neurol. Med. Chir.(Tokyo)"],"published-print":{"date-parts":[[2023,5,15]]},"DOI":"10.2176\/jns-nmc.2022-0215","type":"journal-article","created":{"date-parts":[[2023,4,5]],"date-time":"2023-04-05T22:10:44Z","timestamp":1680732644000},"page":"206-212","source":"Crossref","is-referenced-by-count":0,"title":["Transarticular Fixation Using Bioabsorptive Screws for Cervical Lesions"],"prefix":"10.2176","volume":"63","author":[{"given":"Daijiro","family":"MORIMOTO","sequence":"first","affiliation":[{"name":"Department of Neurological Surgery, Nippon Medical School"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kyongsong","family":"KIM","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Chiba Hokuso Hospital, Nippon Medical School"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rinko","family":"KOKUBO","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Chiba Hokuso Hospital, Nippon Medical School"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takao","family":"KITAMURA","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Nippon Medical School"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toyohiko","family":"ISU","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Kushiro Rosai Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akio","family":"MORITA","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Nippon Medical School"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"971","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1) Yagi M, Ninomiya K, Kihara M, Horiuchi Y: Long-term surgical outcome and risk factors in patients with cervical myelopathy and a change in signal intensity of intramedullary spinal cord on magnetic resonance imaging. <i>J Neurosurg Spine<\/i> 12: 59-65, 2010","DOI":"10.3171\/2009.5.SPINE08940"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2) Miyamoto H, Sumi M, Uno K: Utility of modified transarticular screw in the middle and lower cervical spine as intermediate fixation in posterior long fusion surgery. <i>J Neurosurg Spine<\/i> 11: 555-561, 2009","DOI":"10.3171\/2009.5.SPINE08348"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3) Kim K, Nariai M, Kawauchi M, et al.: Is the vertebral posterior line a safety landmark for cervical posterior screw insertion?-radiological study of the vertebral artery in the cervical spine. <i>Neurol Med Chir Tokyo<\/i> 60: 223-228, 2020","DOI":"10.2176\/nmc.oa.2019-0244"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4) Coe JD, Vaccaro AR, Dailey AT, et al.: Lateral mass screw fixation in the cervical spine: a systematic literature review. <i>J Bone Joint Surg Am<\/i> 95: 2136-2143, 2013","DOI":"10.2106\/JBJS.L.01522"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5) Jones EL, Heller JG, Silcox DH, Hutton WC: Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison. <i>Spine (Phila PA 1976)<\/i> 22: 977-982, 1997","DOI":"10.1097\/00007632-199705010-00009"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6) Heller JG, Estes BT, Zaouali M, Diop A: Biomechanical study of screws in the lateral masses: variables affecting pull-out resistance. <i>J Bone Joint Surg Am<\/i> 78: 1315-1321, 1996","DOI":"10.2106\/00004623-199609000-00004"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7) Takayasu M, Hara M, Yamauchi K, et al.: Transarticular screw fixation in the middle and lower cervical spine [technical note]. <i>J Neurol Surg<\/i> 99: S132-S136, 2013","DOI":"10.3171\/spi.2003.99.1.0132"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8) DalCanto RA, Lieberman I, Inceoglu S, Kayanja M, Ferrara L: Biomechanical comparison of transarticular facet screws to lateral mass plates in two-level instrumentations of the cervical spine. <i>Spine<\/i> 30: 897-892, 2005","DOI":"10.1097\/01.brs.0000158937.64577.25"},{"key":"9","unstructured":"9) Liu GY, Xu RM, Ma WH, Ruan YP, Sun SH, Huang L: Anatomic comparison of transarticular screws with lateral mass screws in cervical vertebrae. <i>Chin J Traumatol<\/i> 10: 67-71, 2007"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10) Klekamp JW, Ugbo JL, Heller JG, Hutton WC: Cervical transfacet versus lateral mass screws: a biomechanical comparison. <i>J Spinal Disord<\/i> 13: 515-518, 2000","DOI":"10.1097\/00002517-200012000-00009"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11) Miyanji F, Mahar A, Oka R, Newton P: Biomechanical differences between transfacet and lateral mass screw-rod constructs for multilevel posterior cervical spine stabilization. <i>Spine<\/i> 33: E865-E869, 2008","DOI":"10.1097\/BRS.0b013e318184ace8"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12) Kim K, Isu T, Sugawara A, Matsumoto R, Isobe M: Utility of new bioabsorptive screws in cervical anterior fusion. <i>Surg Neurol<\/i> 68: 264-268, 2007","DOI":"10.1016\/j.surneu.2006.11.061"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13) Park MS, Aryan HE, Ozgur BM, Jandial R, Taylor WR: Stabilization of anterior cervical spine with bioabsorbable polymer in one- and two-level fusions. <i>Neurosurgery<\/i> 54: 631-635, 2004","DOI":"10.1227\/01.NEU.0000108942.07872.2A"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14) Vaccaro AR, Carrino JA, Venger BH, et al.: Use of a bioabsorbable anterior cervical plate in the treatment of cervical degenerative and traumatic disc disruption. <i>J Neurosurg<\/i> 97: 473-480, 2002","DOI":"10.3171\/spi.2002.97.4.0473"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15) Kim K, Isu T, Omura T, Morimoto D, Kobayashi S, Teramoto A: Transarticular fixation with a bioabsorptive screw for cervical spondylolisthesis. <i>World Neurosurg<\/i> 81: 843.e5-843.e9, 2014","DOI":"10.1016\/j.wneu.2013.01.024"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16) Shikinami Y, Okuno M: Bioresorbable devices made of forged composites of hydroxyapatite (HA) particles and poly-L-lactide (PLLA): part I. Basic characteristics. <i>Biomaterials<\/i> 20: 859-877, 1999","DOI":"10.1016\/S0142-9612(98)00241-5"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17) Shikinami Y, Okuno M: Bioresorbable devices made of forged composites of hydroxyapatite (HA) particles and poly L-lactide (PLLA). Part II: Practical properties of miniscrews and miniplates. <i>Biomaterials<\/i> 22: 3197-3211, 2001","DOI":"10.1016\/S0142-9612(01)00072-2"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18) Shikinami Y, Matsusue Y, Nakamura T: The complete process of bioresorption and bone replacement using devices made of forged composites of raw hydroxyapatite particles\/poly l-lactide (F-u-HA\/PLLA). <i>Biomaterials<\/i> 26: 5542-5551, 2005","DOI":"10.1016\/j.biomaterials.2005.02.016"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19) Ames CP, Crawford NR, Chamberlain RH, Deshmukh V, Sadikovic B, Sonntag VK: Biomechanical evaluation of a bioresorbable odontoid screw. <i>J Neurosurg Spine<\/i> 2: 182-187, 2005","DOI":"10.3171\/spi.2005.2.2.0182"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20) Kim K, Isu T, Sugawara A, Matsumoto R, Isobe M: Prediction of postoperative alignment in patients undergoing anterior cervical fusion using autologous vertebral bone grafting. <i>Neurol Med Chir (Tokyo)<\/i> 48: 201-206, 2008","DOI":"10.2176\/nmc.48.201"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21) Dean CL, Gabriel JP, Cassinelli EH, Bolesta MJ, Bohlman HH: Degenerative spondylolisthesis of the cervical spine: analysis of 58 patients treated with anterior cervical decompression and fusion. <i>Spine J<\/i> 9: 439-446, 2009","DOI":"10.1016\/j.spinee.2008.11.010"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22) White AA III, Johnson RM, Panjabi MM, et al.: Biomechanical analysis of clinical stability in the cervical spine. <i>Clin Orthop Relat Res<\/i> 109: 85-96, 1975","DOI":"10.1097\/00003086-197506000-00011"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23) McCormack BM, Bundoc RC, Ver MR, et al.: Percutaneous posterior cervical fusion with the DTRAX Facet System for single-level radiculopathy: results in 60 patients. <i>J Neurosurg Spine<\/i> 18: 245-254, 2013","DOI":"10.3171\/2012.12.SPINE12477"}],"container-title":["Neurologia medico-chirurgica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/nmc\/63\/5\/63_2022-0215\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,20]],"date-time":"2023-05-20T04:27:04Z","timestamp":1684556824000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/nmc\/63\/5\/63_2022-0215\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,15]]},"references-count":23,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.2176\/jns-nmc.2022-0215","relation":{},"ISSN":["0470-8105","1349-8029"],"issn-type":[{"value":"0470-8105","type":"print"},{"value":"1349-8029","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,15]]},"article-number":"2022-0215"}}