{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T00:29:36Z","timestamp":1780532976838,"version":"3.54.1"},"reference-count":24,"publisher":"Japan Neurosurgical Society","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Neurol. Med. Chir.(Tokyo)"],"published-print":{"date-parts":[[2023,2,15]]},"DOI":"10.2176\/jns-nmc.2022-0217","type":"journal-article","created":{"date-parts":[[2022,12,19]],"date-time":"2022-12-19T22:22:42Z","timestamp":1671488562000},"page":"58-64","source":"Crossref","is-referenced-by-count":16,"title":["Pipeline Flex with Shield Technology Placement for Small- and Medium-sized Aneurysms Achieves Early Complete Occlusion"],"prefix":"10.2176","volume":"63","author":[{"given":"Sho","family":"ARAI","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Graduate School of Medicine, Juntendo University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"FUJII","sequence":"additional","affiliation":[{"name":"Department of Neuroendovascular Therapy, Graduate School of Medicine, Juntendo University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kohsuke","family":"TERANISHI","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Graduate School of Medicine, Juntendo University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Senshu","family":"NONAKA","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Graduate School of Medicine, Juntendo University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takayuki","family":"KITAMURA","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Graduate School of Medicine, Juntendo University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yumiko","family":"MITOME-MISHIMA","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Graduate School of Medicine, Juntendo University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akihide","family":"KONDO","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Graduate School of Medicine, Juntendo University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hidenori","family":"OISHI","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Graduate School of Medicine, Juntendo University"},{"name":"Department of Neuroendovascular Therapy, Graduate School of Medicine, Juntendo University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"971","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1) Nelson PK, Lylyk P, Szikora I, Wetzel SG, Wanke I, Fiorella D: The pipeline embolization device for the intracranial treatment of aneurysms trial. <i>AJNR Am J Neuroradiol<\/i> 32: 34-40, 2011","DOI":"10.3174\/ajnr.A2421"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2) Becske T, Kallmes DF, Saatci I, et al.: Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial. <i>Radiology<\/i> 267: 858-868, 2013","DOI":"10.1148\/radiol.13120099"},{"key":"3","unstructured":"3) Kallmes DF, Hanel R, Lopes D, et al.: International retrospective study of the pipeline embolization device: a multicenter aneurysm treatment study. <i>AJNR Am J Neuroradiol<\/i> 36: 108-115, 2015"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4) Oishi H, Teranishi K, Yatomi K, Fujii T, Yamamoto M, Arai H: Flow diverter therapy using a pipeline embolization device for 100 unruptured large and giant internal carotid artery aneurysms in a single center in a Japanese population. <i>Neurol Med Chir (Tokyo)<\/i> 58: 461-467, 2018","DOI":"10.2176\/nmc.oa.2018-0148"},{"key":"5","unstructured":"5) Hanel RA, Kallmes DF, Lopes DK, et al.: Prospective study on embolization of intracranial aneurysms with the pipeline device: the PREMIER study 1 year results. <i>J Neurointerv Surg<\/i> 12: 62-66, 2020"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6) Hanel RA, Monteiro A, Nelson PK, Lopes DK, Kallmes DF: Predictors of incomplete aneurysm occlusion after treatment with the Pipeline Embolization Device: PREMIER trial 1 year analysis. <i>J Neurointerv Surg<\/i> 14: 1014-1017, 2022","DOI":"10.1136\/neurintsurg-2021-018054"},{"key":"7","doi-asserted-by":"publisher","unstructured":"7) Hanel RA, Cortez GM, Lopes DK, et al.: Prospective study on embolization of intracranial aneurysms with the pipeline device (PREMIER study): 3-year results with the application of a flow diverter specific occlusion classification. <i>J Neurointerv Surg<\/i> 2022. doi: 10.1136\/neurintsurg-2021-018501","DOI":"10.1136\/neurintsurg-2021-018501"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8) Li L, Bu-Lang G, Qiu-Ji S, et al.: Small unruptured intracranial aneurysms can be effectively treated with flow-diverting devices. <i>Front Neurol<\/i> 13: 91365, 2022","DOI":"10.3389\/fneur.2022.913653"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9) Pereira VM, Kelly M, Vega P, et al.: New pipeline flex device: initial experience and technical nuances. <i>J Neurointerv Surg<\/i> 7: 920-925, 2015","DOI":"10.1136\/neurintsurg-2014-011347"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10) Matsuda Y, Jang DK, Chung J, Wainwright JM, Lopes D: Preliminary outcomes of single antiplatelet therapy for surface-modified flow diverters in an animal model: analysis of neointimal development and thrombus formation using OCT. <i>J Neurointerv Surg<\/i> 11: 74-79, 2019","DOI":"10.1136\/neurintsurg-2018-013935"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11) Kulcsar Z, Houdart E, Bonafe A, et al.: Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment. <i>AJNR Am J Neuroradiol<\/i> 32: 20-25, 2011","DOI":"10.3174\/ajnr.A2370"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12) Roy D, Milot G, Raymond J: Endovascular treatment of unruptured aneurysms. <i>Stroke<\/i> 32: 1998-2004, 2001","DOI":"10.1161\/hs0901.095600"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13) Campbell EJ, O&apos;Byrne V, Stratford PW, et al.: Biocompatible surfaces using methacryloylphosphorylcholine laurylmethacrylate copolymer. <i>ASAIO J<\/i> 40: M853-M857, 1994","DOI":"10.1097\/00002480-199407000-00118"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14) Manning NW, Cheung A, Phillips TJ, Wenderoth JD: Pipeline shield with single antiplatelet therapy in aneurysmal subarachnoid haemorrhage: multicentre experience. <i>J Neurointerv Surg<\/i> 11: 694-698, 2019","DOI":"10.1136\/neurintsurg-2018-014363"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15) Cappuzzo JM, Monteiro A, Taylor MN, et al.: First U.S. experience using the pipeline flex embolization device with shield technology for treatment of intracranial aneurysms. <i>World Neurosurg<\/i> 159: e184-e191, 2022","DOI":"10.1016\/j.wneu.2021.12.031"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16) Rice H, Martinez Galdamez M, Holtmannspotter M, et al.: Periprocedural to 1-year safety and efficacy outcomes with the Pipeline Embolization Device with Shield technology for intracranial aneurysms: a prospective, post-market, multi-center study. <i>J Neurointerv Surg<\/i> 12: 1107-1112, 2020","DOI":"10.1136\/neurintsurg-2020-015943"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17) Ravindran K, Casabella AM, Cebral J, Brinjikji W, Kallmes DF, Kadirvel R: Mechanism of action and biology of flow diverters in the treatment of intracranial aneurysms. <i>Neurosurgery<\/i> 86: S13-S19, 2020","DOI":"10.1093\/neuros\/nyz324"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18) Zhang Q, Shao Q, Chang K, et al.: Safety and efficacy of coils in conjunction with the pipeline flex embolization device for the treatment of cerebral aneurysms. <i>Front Neurol<\/i> 12: 651465, 2021","DOI":"10.3389\/fneur.2021.651465"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19) Lin N, Brouillard AM, Krishna C, et al.: Use of coils in conjunction with the pipeline embolization device for treatment of intracranial aneurysms. <i>Neurosurgery<\/i> 76: 142-149, 2015","DOI":"10.1227\/NEU.0000000000000579"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20) Fujii T, Teranishi K, Yatomi K, et al.: Long-term follow-up results after flow diverter therapy using the Pipeline Embolization Device for large or giant unruptured internal carotid artery aneurysms: single-center retrospective analysis in the Japanese population. <i>Neurol Med Chir (Tokyo)<\/i> 62: 19-27, 2022","DOI":"10.2176\/nmc.oa.2021-0203"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21) Brinjikji W, Kallmes DF, Cloft HJ, Lanzino G: Age-related outcomes following intracranial aneurysm treatment with the Pipeline Embolization Device: a subgroup analysis of the IntrePED registry. <i>J Neurosurg<\/i> 124: 1726-1730, 2016","DOI":"10.3171\/2015.5.JNS15327"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22) Adeeb N, Moore JM, Wirtz M, et al.: Predictors of incomplete occlusion following pipeline embolization of intracranial aneurysms: Is it less effective in older patients? <i>AJNR Am J Neuroradiol<\/i> 38: 2295-2300, 2017","DOI":"10.3174\/ajnr.A5375"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23) Kole MJ, Miller TR, Cannarsa G, et al.: Pipeline embolization device diameter is an important factor determining the efficacy of flow diversion treatment of small intracranial saccular aneurysms. <i>J Neurointerv Surg<\/i> 11: 1004-1008, 2019","DOI":"10.1136\/neurintsurg-2019-014792"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24) Kan P, Srinivasan VM, Mbabuike N, et al.: Aneurysms with persistent patency after treatment with the Pipeline Embolization Device. <i>J Neurosurg<\/i> 126: 1894-1898, 2017","DOI":"10.3171\/2016.6.JNS16402"}],"container-title":["Neurologia medico-chirurgica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/nmc\/63\/2\/63_2022-0217\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,10]],"date-time":"2024-05-10T04:32:46Z","timestamp":1715315566000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/nmc\/63\/2\/63_2022-0217\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,15]]},"references-count":24,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.2176\/jns-nmc.2022-0217","relation":{},"ISSN":["0470-8105","1349-8029"],"issn-type":[{"value":"0470-8105","type":"print"},{"value":"1349-8029","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,2,15]]},"article-number":"2022-0217"}}