{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T13:38:59Z","timestamp":1782481139362,"version":"3.54.5"},"reference-count":20,"publisher":"Japan Neurosurgical Society","issue":"0","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,12,31]]},"DOI":"10.2176\/jns-nmc.2024-0106","type":"journal-article","created":{"date-parts":[[2024,10,10]],"date-time":"2024-10-10T22:13:50Z","timestamp":1728598430000},"page":"273-278","source":"Crossref","is-referenced-by-count":1,"title":["A Late Complication Related to Percutaneous Implantable Leads for Spinal Cord Stimulation: Myelopathy due to Fibrous Scar Tissue"],"prefix":"10.2176","volume":"11","author":[{"given":"Takuma","family":"MAEDA","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Tokyo Metropolitan Neurological Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"AGARI","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Tokyo Metropolitan Neurological Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"KOMORI","sequence":"additional","affiliation":[{"name":"Laboratory Medicine and Pathology, Tokyo Metropolitan Neurological Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keisuke","family":"TAKAI","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Tokyo Metropolitan Neurological Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"971","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1) Shealy CN, Mortimer JT, Reswick JB: Electrical inhibition of pain by stimulation of the dorsal columns: preliminary clinical report. <i>Anesth Analg<\/i> 46: 489-491, 1967","DOI":"10.1213\/00000539-196707000-00025"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2) Kumar K, Taylor RS, Jacques L, et al.: Spinal cord stimulation versus conventional medical management for neuropathic pain: a multicentre randomised controlled trial in patients with failed back surgery syndrome. <i>Pain<\/i> 132: 179-188, 2007","DOI":"10.1016\/j.pain.2007.07.028"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3) Kemler MA, Barendse GA, van Kleef M, et al.: Spinal cord stimulation in patients with chronic reflex sympathetic dystrophy. <i>N Engl J Med<\/i> 343: 618-624, 2000","DOI":"10.1056\/NEJM200008313430904"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4) Turner JA, Loeser JD, Bell KG: Spinal cord stimulation for chronic low back pain: a systematic literature synthesis. <i>Neurosurgery<\/i> 37: 1088-1095; discussion 1095, 1995","DOI":"10.1097\/00006123-199512000-00008"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5) Guzzi G, Volpentesta G, Chirchiglia D, Della Torre A, Lavano F, Lavano A: Cervical spinal cord compression from delayed epidural scar tissue formation around plate lead for SCS. <i>J Neurosurg Sci<\/i> 63: 337-343, 2019","DOI":"10.23736\/S0390-5616.16.03449-4"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6) Wloch A, Capelle HH, Saryyeva A, Krauss JK: Cervical myelopathy due to an epidural cervical mass after chronic cervical spinal cord stimulation. <i>Stereotact Funct Neurosurg<\/i> 91: 265-269, 2013","DOI":"10.1159\/000346501"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7) Pallotta ML, Lovi A, Luca A, Babbi L, Brayda-Bruno M: Spinal cord stimulator medullary compression-a very rare SCS complication and surgical treatment. <i>Spinal Cord Ser Cases<\/i> 8: 84, 2022","DOI":"10.1038\/s41394-022-00550-6"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8) Fransen P: Reversible late thoracic myelopathy and neurostimulation tolerance caused by fibrous scar tissue formation around the spinal cord stimulation electrode. <i>Neuromodulation<\/i> 18: 759-761, 2015","DOI":"10.1111\/ner.12282"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9) Benfield J, Maknojia A, Epstein F: Progressive paraplegia from spinal cord stimulator lead fibrotic encapsulation: A case report. <i>Am J Phys Med Rehabil<\/i> 95: e30-e33, 2016","DOI":"10.1097\/PHM.0000000000000411"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10) Al Tamimi M, Aoun SG, Gluf W: Spinal cord compression secondary to epidural fibrosis associated with percutaneously placed spinal cord stimulation electrodes: case report and review of the literature. <i>World Neurosurg<\/i> 104: 1051.e1-1051.e5, 2017","DOI":"10.1016\/j.wneu.2017.05.152"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11) Lennarson PJ, Guillen FT: Spinal cord compression from a foreign body reaction to spinal cord stimulation: a previously unreported complication. <i>Spine<\/i> 35: E1516-E1519, 2010","DOI":"10.1097\/BRS.0b013e3181ecc965"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12) Wada E, Kawai H: Late onset cervical myelopathy secondary to fibrous scar tissue formation around the spinal cord stimulation electrode. <i>Spinal Cord<\/i> 48: 646-648, 2010","DOI":"10.1038\/sc.2009.188"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13) Cicuendez M, Munarriz PM, Casta\u00f1o-Leon AM, Paredes I: Dorsal myelopathy secondary to epidural fibrous scar tissue around a spinal cord stimulation electrode. <i>J Neurosurg Spine<\/i> 17: 598-601, 2012","DOI":"10.3171\/2012.9.SPINE12334"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14) Dam-Hieu P, Magro E, Seizeur R, Simon A, Quinio B: Cervical cord compression due to delayed scarring around epidural electrodes used in spinal cord stimulation. <i>J Neurosurg Spine<\/i> 12: 409-412, 2010","DOI":"10.3171\/2009.10.SPINE09193"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15) Scranton RA, Skaribas IM, Simpson RK: Spinal stimulator peri-electrode masses: case report. <i>J Neurosurg Spine<\/i> 22: 70-74, 2015","DOI":"10.3171\/2014.10.SPINE1425"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16) Cameron T: Safety and efficacy of spinal cord stimulation for the treatment of chronic pain: a 20-year literature review. <i>J Neurosurg<\/i> 100: 254-267, 2004","DOI":"10.3171\/spi.2004.100.3.0254"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17) Delaplace M, Ma\u00eetre F, Dufour T, et al.: [Two cases of cutaneous erythema following spinal cord stimulation]. <i>Ann Dermatol Venereol<\/i> 137: 297-300, 2010","DOI":"10.1016\/j.annder.2010.02.017"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18) Liu J, Guo X, Ren X, et al.: A novel FPCL model producing directional contraction through induction of fibroblast alignment by biphasic pulse direct current electric field. <i>Exp Cell Res<\/i> 371: 426-434, 2018","DOI":"10.1016\/j.yexcr.2018.09.003"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19) Huang YJ, Samorajski J, Kreimer R, Searson PC: The influence of electric field and confinement on cell motility. <i>PLOS ONE<\/i> 8: e59447, 2013","DOI":"10.1371\/journal.pone.0059447"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20) Fishman MA, Antony A, Esposito M, Deer T, Levy R: The evolution of neuromodulation in the treatment of chronic pain: forward-looking perspectives. <i>Pain Med<\/i> 20: S58-S68, 2019","DOI":"10.1093\/pm\/pnz074"}],"container-title":["NMC Case Report Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/nmccrj\/11\/0\/11_2024-0106\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,12]],"date-time":"2024-10-12T05:09:43Z","timestamp":1728709783000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/nmccrj\/11\/0\/11_2024-0106\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,31]]},"references-count":20,"journal-issue":{"issue":"0","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.2176\/jns-nmc.2024-0106","relation":{},"ISSN":["2188-4226"],"issn-type":[{"value":"2188-4226","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,31]]},"article-number":"2024-0106"}}