{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,24]],"date-time":"2026-07-24T10:16:12Z","timestamp":1784888172441,"version":"3.55.0"},"reference-count":24,"publisher":"Japan Neurosurgical Society","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Neurol. Med. Chir.(Tokyo)"],"published-print":{"date-parts":[[2025,5,15]]},"DOI":"10.2176\/jns-nmc.2024-0297","type":"journal-article","created":{"date-parts":[[2025,3,20]],"date-time":"2025-03-20T22:14:28Z","timestamp":1742508868000},"page":"247-254","source":"Crossref","is-referenced-by-count":4,"title":["Comparison of the Tigertriever and Self-expanding Stent Retrievers for Mechanical Thrombectomy of Acute Ischemic Stroke: A Single-center Experience"],"prefix":"10.2176","volume":"65","author":[{"given":"Koichiro","family":"SHINDO","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Hyogo Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazutaka","family":"UCHIDA","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Hyogo Medical University"},{"name":"Department of Epidemiology, Hyogo Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manabu","family":"SHIRAKAWA","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Hyogo Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shoichiro","family":"TSUJI","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Hyogo Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuntaro","family":"KUWAHARA","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Hyogo Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoji","family":"KURAMOTO","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Hyogo Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shinichi","family":"YOSHIMURA","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Hyogo Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"971","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1) Goyal M, Menon BK, van Zwam WH, et al. Endovascular thrombectomy after large-vessel ischaemic stroke: a meta-analysis of individual patient data from five randomised trials. Lancet. 2016;387 (10029):1723-31. doi: 10.1016\/S0140-6736(16)00163-X","DOI":"10.1016\/S0140-6736(16)00163-X"},{"key":"2","doi-asserted-by":"publisher","unstructured":"2) Bhogal P, Andersson T, Maus V, et al. Mechanical Thrombectomy-A Brief Review of a Revolutionary new Treatment for thromboembolic Stroke. Clin Neuroradiol. 2018;28 (3):313-26. doi: 10.1007\/s00062-018-0692-2","DOI":"10.1007\/s00062-018-0692-2"},{"key":"3","doi-asserted-by":"publisher","unstructured":"3) Gupta R, Saver JL, Levy E, et al. New class of radially adjustable Stentrievers for acute ischemic stroke: primary results of the multicenter TIGER trial. Stroke. 2021;52 (5):1534-44. doi: 10.1161\/STROKEAHA.121.034436","DOI":"10.1161\/STROKEAHA.121.034436"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4) Yamagami H, Hayakawa M, Inoue M, et al. Guidelines for mechanical thrombectomy in Japan, the fourth edition, March 2020: a guideline from the Japan Stroke Society, the Japan Neurosurgical Society, and the Japanese Society for Neuroendovascular Therapy. Neurol Med Chir (Tokyo). 2021;61 (3):163-92. doi: 10.2176\/nmc.st.2020-0357","DOI":"10.2176\/nmc.nmc.st.2020-0357"},{"key":"5","doi-asserted-by":"publisher","unstructured":"5) Toyoda K, Koga M, Iguchi Y, et al. Guidelines for intravenous thrombolysis (recombinant tissue-type plasminogen activator), the third edition, March 2019: a guideline from the Japan Stroke Society. Neurol Med Chir (Tokyo). 2019;59 (12):449-91. doi: 10.2176\/nmc.st.2019-0177","DOI":"10.2176\/nmc.st.2019-0177"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6) Van Swieten JC, Koudstaal PJ, Visser MC, et al. Interobserver agreement for the assessment of handicap in stroke patients. Stroke. 1988;19 (5):604-7. doi: 10.1161\/01.str.19.5.604","DOI":"10.1161\/01.STR.19.5.604"},{"key":"7","unstructured":"7) Pexman JH, Barber PA, Hill MD, et al. Use of the Alberta Stroke Program Early CT Score (ASPECTS) for assessing CT scans in patients with acute stroke. AJNR Am J Neuroradiol. 2001;22 (8):1534-42."},{"key":"8","doi-asserted-by":"publisher","unstructured":"8) Zaidat OO, Yoo AJ, Khatri P, et al. Recommendations on angiographic revascularization grading standards for acute ischemic stroke: a consensus statement. Stroke. 2013;44 (9):2650-63. doi: 10.1161\/STROKEAHA.113.001972","DOI":"10.1161\/STROKEAHA.113.001972"},{"key":"9","doi-asserted-by":"publisher","unstructured":"9) Larrue V, von Kummer R R, M\u00fcller A, et al. Risk factors for severe hemorrhagic transformation in ischemic stroke patients treated with recombinant tissue plasminogen activator: a secondary analysis of the European-Australasian Acute Stroke Study (ECASS II). Stroke. 2001;32 (2):438-41. doi: 10.1161\/01.str.32.2.438","DOI":"10.1161\/01.STR.32.2.438"},{"key":"10","doi-asserted-by":"publisher","unstructured":"10) Zaidat OO, Castonguay AC, Linfante I, et al. First pass effect: a new measure for stroke thrombectomy devices. Stroke. 2018;49 (3):660-6. doi: 10.1161\/STROKEAHA.117.020315","DOI":"10.1161\/STROKEAHA.117.020315"},{"key":"11","doi-asserted-by":"publisher","unstructured":"11) Saber H, Froehler MT, Zaidat OO, et al. Variation in vessel size and angiographic outcomes following stent-retriever thrombectomy in acute ischemic stroke: STRATIS registry. Stroke Vasc Interv Neurol. 2024;4 (3):e000978. doi: 10.1161\/SVIN.123.000978","DOI":"10.1161\/SVIN.123.000978"},{"key":"12","doi-asserted-by":"publisher","unstructured":"12) Baharvahdat H, Ooi YC, Khatibi K, et al. Increased rate of successful first passage recanalization during mechanical thrombectomy for M2 occlusion. World Neurosurg. 2020;139:e792-9. doi: 10.1016\/j.wneu.2020.04.159","DOI":"10.1016\/j.wneu.2020.04.159"},{"key":"13","doi-asserted-by":"publisher","unstructured":"13) Giray S, Ozdemir O, Ba\u015f DF, et al. Does stroke etiology play a role in predicting outcome of acute stroke patients who underwent endovascular treatment with stent retrievers? J Neurol Sci. 2017;372:104-9. doi: 10.1016\/j.jns.2016.11.006","DOI":"10.1016\/j.jns.2016.11.006"},{"key":"14","doi-asserted-by":"publisher","unstructured":"14) Kolahchi Z, Rahimian N, Momtazmanesh S, et al. Direct mechanical thrombectomy versus prior bridging intravenous thrombolysis in acute ischemic stroke: a systematic review and meta-analysis. Life (Basel). 2023;13 (1):185. doi: 10.3390\/life13010185","DOI":"10.3390\/life13010185"},{"key":"15","doi-asserted-by":"publisher","unstructured":"15) Kara B, Selcuk HH, Erbahceci Salik A, et al. Single-center experience with the Tigertriever device for the recanalization of large vessel occlusions in acute ischemic stroke. J Neurointerv Surg. 2019;11 (5):455-9. doi: 10.1136\/neurintsurg-2018-014196","DOI":"10.1136\/neurintsurg-2018-014196"},{"key":"16","doi-asserted-by":"publisher","unstructured":"16) Jankowitz B, Abergel E, Agid R, et al. Optimizing Tigertriever adjustable stentriever technique: operators&apos; experience. Interv Neuroradiol. 2024;29 (1):15910199241272743. doi: 10.1177\/15910199241272743","DOI":"10.1177\/15910199241272743"},{"key":"17","doi-asserted-by":"publisher","unstructured":"17) Piasecki P, Wierzbicki M, Narloch J, et al. Mechanical thrombectomy of large vessel occlusion using adjustable vs. self-expanding stent-retriever-Comparison of Tigertriever device with stent-like stent-retrievers: a propensity score analysis. Front Neurol. 2022;13:1032307. doi: 10.3389\/fneur.2022.1032307","DOI":"10.3389\/fneur.2022.1032307"},{"key":"18","doi-asserted-by":"publisher","unstructured":"18) Piasecki P, Wierzbicki M, Narloch J. Safety and efficacy of mechanical thrombectomy using Tigertriever as a rescue device after failed aspiration-Single Center experience. Front Neurol. 2020;11:11603679. doi: 10.3389\/fneur.2020.603679","DOI":"10.3389\/fneur.2020.603679"},{"key":"19","doi-asserted-by":"publisher","unstructured":"19) Brinjikji W, Starke RM, Murad MH, et al. Impact of balloon guide catheter on technical and clinical outcomes: a systematic review and meta-analysis. J Neurointerv Surg. 2018;10 (4):335-9. doi: 10.1136\/neurintsurg-2017-013179","DOI":"10.1136\/neurintsurg-2017-013179"},{"key":"20","doi-asserted-by":"publisher","unstructured":"20) Ding Y, Mao X, Bao L, et al. Impact of stent retriever size on clinical outcomes in the RECO registry. Heliyon. 2024;10 (7):e28873. doi: 10.1016\/j.heliyon.2024.e28873","DOI":"10.1016\/j.heliyon.2024.e28873"},{"key":"21","doi-asserted-by":"publisher","unstructured":"21) Lee HG, Yi HJ, Shin DS, et al. Comparison of 4 mm-sized and 3 mm-sized Stent Retrievers in Mechanical Thrombectomy for M2 Occlusion. Curr Neurovasc Res. 2024;21 (2):157-65. doi: 10.2174\/0115672026303196240327053722","DOI":"10.2174\/0115672026303196240327053722"},{"key":"22","doi-asserted-by":"publisher","unstructured":"22) M\u00f6nch S, Boeckh-Behrens T, Maegerlein C, et al. Mechanical thrombectomy of the middle cerebral artery - neither segment nor diameter matter. J Stroke Cerebrovasc Dis. 2020;29 (2):104542. doi: 10.1016\/j.jstrokecerebrovasdis.2019.104542","DOI":"10.1016\/j.jstrokecerebrovasdis.2019.104542"},{"key":"23","doi-asserted-by":"publisher","unstructured":"23) Rhiner N, Thut MZ, Thurner P, et al. Impact of age on mechanical thrombectomy and clinical outcome in patients with acute ischemic stroke. J Stroke Cerebrovasc Dis. 2023;32 (9):107248. doi: 10.1016\/j.jstrokecerebrovasdis.2023.107248","DOI":"10.1016\/j.jstrokecerebrovasdis.2023.107248"},{"key":"24","doi-asserted-by":"publisher","unstructured":"24) Toyoda K. Epidemiology and registry studies of stroke in Japan. J Stroke. 2013;15 (1):21-6. doi: 10.5853\/jos.2013.15.1.21","DOI":"10.5853\/jos.2013.15.1.21"}],"container-title":["Neurologia medico-chirurgica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/nmc\/65\/5\/65_2024-0297\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,17]],"date-time":"2025-05-17T03:42:59Z","timestamp":1747453379000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/nmc\/65\/5\/65_2024-0297\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,15]]},"references-count":24,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.2176\/jns-nmc.2024-0297","relation":{},"ISSN":["0470-8105","1349-8029"],"issn-type":[{"value":"0470-8105","type":"print"},{"value":"1349-8029","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,15]]},"article-number":"2024-0297"}}