{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T21:04:08Z","timestamp":1762376648890},"reference-count":27,"publisher":"Japan Neurosurgical Society","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Neurol. Med. Chir.(Tokyo)"],"published-print":{"date-parts":[[2020]]},"DOI":"10.2176\/nmc.oa.2019-0170","type":"journal-article","created":{"date-parts":[[2019,11,26]],"date-time":"2019-11-26T22:04:24Z","timestamp":1574805864000},"page":"30-36","source":"Crossref","is-referenced-by-count":8,"title":["Simple Identification of Cerebrospinal Fluid Turbulent Motion Using a Dynamic Improved Motion-sensitized Driven-equilibrium Steady-state Free Precession Method Applied to Various Types of Cerebrospinal Fluid Motion Disturbance"],"prefix":"10.2176","volume":"60","author":[{"given":"Hideki","family":"ATSUMI","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Tokai University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomohiko","family":"HORIE","sequence":"additional","affiliation":[{"name":"Division of Diagnostic Image Analysis, Tohoku University Graduate School of Medicine"},{"name":"Department of Radiology, Tokai University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nao","family":"KAJIHARA","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tokai University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Azusa","family":"SUNAGA","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Tokai University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yumetaro","family":"SAKAKIBARA","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Tokai University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mitsunori","family":"MATSUMAE","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Tokai University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"971","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1) Matsumae M, Kuroda K, Yatsushiro S, et al.: Changing the currently held concept of cerebrospinal fluid dynamics based on shared findings of cerebrospinal fluid motion in the cranial cavity using various types of magnetic resonance imaging techniques. <i>Neurol Med Chir<\/i> (<i>Tokyo<\/i>) 59: 133\u2013146, 2019","DOI":"10.2176\/nmc.ra.2018-0272"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2) Hayashi N, Matsumae M, Yatsushiro S, Hirayama A, Abdullah A, Kuroda K: Quantitative analysis of cerebrospinal fluid pressure gradients in healthy volunteers and patients with normal pressure hydrocephalus. <i>Neurol Med Chir<\/i> (<i>Tokyo<\/i>) 55: 657\u2013662, 2015","DOI":"10.2176\/nmc.oa.2014-0339"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3) Horie T, Kajihara N, Matsumae M, et al.: Magnetic resonance imaging technique for visualization of irregular cerebrospinal fluid motion in the ventricular system and subarachnoid space. <i>World Neurosurg<\/i> 97: 523\u2013531, 2017","DOI":"10.1016\/j.wneu.2016.07.062"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4) Wang J, Yarnykh VL, Yuan C: Enhanced image quality in black-blood MRI using the improved motion-sensitized driven-equilibrium (iMSDE) sequence. <i>J Magn Reson Imaging<\/i> 31: 1256\u20131263, 2010","DOI":"10.1002\/jmri.22149"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5) Obara M, Kuroda K, Wang J, et al.: Comparison between two types of improved motion-sensitized driven-equilibrium (iMSDE) for intracranial black-blood imaging at 3.0 tesla. <i>J Magn Reson Imaging<\/i> 40: 824\u2013831, 2014","DOI":"10.1002\/jmri.24430"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6) Koktzoglou I, Li D: Submillimeter isotropic resolution carotid wall MRI with swallowing compensation: imaging results and semiautomated wall morphometry. <i>J Magn Reson Imaging<\/i> 25: 815\u2013823, 2007","DOI":"10.1002\/jmri.20849"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7) Fan Z, Zhang Z, Chung YC, et al.: Carotid arterial wall MRI at 3T using 3D variable-flip-angle turbo spin-echo (TSE) with flow-sensitive dephasing (FSD). <i>J Magn Reson Imaging<\/i> 31: 645\u2013654, 2010","DOI":"10.1002\/jmri.22058"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8) Nagahata S, Nagahata M, Obara M, et al.: Wall enhancement of the intracranial aneurysms revealed by magnetic resonance vessel wall imaging using three-dimensional turbo spin-echo sequence with motion-sensitized driven-equilibrium: a sign of ruptured aneurysm? <i>Clin Neuroradiol<\/i> 26: 277\u2013283, 2016","DOI":"10.1007\/s00062-014-0353-z"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9) Fan Z, Sheehan J, Bi X, Liu X, Carr J, Li D: 3D noncontrast MR angiography of the distal lower extremities using flow-sensitive dephasing (FSD)-prepared balanced SSFP. <i>Magn Reson Med<\/i> 62: 1523\u20131532, 2009","DOI":"10.1002\/mrm.22142"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10) Priest AN, Graves MJ, Lomas DJ: Non-contrast-enhanced vascular magnetic resonance imaging using flow-dependent preparation with subtraction. <i>Magn Reson Med<\/i> 67: 628\u2013637, 2012","DOI":"10.1002\/mrm.23040"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11) Nagao E, Yoshiura T, Hiwatashi A, et al.: 3D turbo spin-echo sequence with motion-sensitized driven-equilibrium preparation for detection of brain metastases on 3T MR imaging. <i>AJNR Am J Neuroradiol<\/i> 32: 664\u2013670, 2011","DOI":"10.3174\/ajnr.A2343"},{"key":"12","unstructured":"12) Kikuchi K, Hiwatashi A, Togao O, et al.: 3D MR sequence capable of simultaneous image acquisitions with and without blood vessel suppression: utility in diagnosing brain metastases. <i>Eur Radiol<\/i> 25: 901\u2013910, 2015"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13) Yoneyama M, Takahara T, Kwee TC, Nakamura M, Tabuchi T: Rapid high resolution MR neurography with a diffusion-weighted pre-pulse. <i>Magn Reson Med Sci<\/i> 12: 111\u2013119, 2013","DOI":"10.2463\/mrms.2012-0063"},{"key":"14","unstructured":"14) Hiwatashi A, Togao O, Yamashita K, et al.: Evaluation of chronic inflammatory demyelinating polyneuropathy: 3D nerve-sheath signal increased with inked rest-tissue rapid acquisition of relaxation enhancement imaging (3D SHINKEI). <i>Eur Radiol<\/i> 27: 447\u2013453, 2017"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15) Thiele H, Nagel E, Paetsch I, et al.: Functional cardiac MR imaging with steady-state free precession (SSFP) significantly improves endocardial border delineation without contrast agents. <i>J Magn Reson Imaging<\/i> 14: 362\u2013367, 2001","DOI":"10.1002\/jmri.1195"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16) Bloomer TN, Plein S, Radjenovic A, et al.: Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricle. <i>J Magn Reson Imaging<\/i> 14: 685\u2013692, 2001","DOI":"10.1002\/jmri.10019"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17) Matsumae M, Hirayama A, Atsumi H, Yatsushiro S, Kuroda K: Velocity and pressure gradients of cerebrospinal fluid assessed with magnetic resonance imaging. <i>J Neurosurg<\/i> 120: 218\u2013227, 2014","DOI":"10.3171\/2013.7.JNS121859"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18) Takizawa K, Matsumae M, Hayashi N, et al.: The choroid plexus of the lateral ventricle as the origin of CSF pulsation is questionable. <i>Neurol Med Chir<\/i> (<i>Tokyo<\/i>) 58: 23\u201331, 2018","DOI":"10.2176\/nmc.oa.2017-0117"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19) Udayakumaran S, Joseph T: Can we predict early endoscopic third ventriculostomy failure? The role of ultra-early postoperative magnetic resonance imaging in predicting early endoscopic third ventriculostomy failure. <i>World Neurosurg X<\/i> 2: 100013, 2019","DOI":"10.1016\/j.wnsx.2019.100013"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20) Okano A, Ogiwara H: Long-term follow-up for patients with infantile hydrocephalus treated by choroid plexus coagulation. <i>J Neurosurg Pediatr<\/i> 22: 638\u2013645, 2018","DOI":"10.3171\/2018.6.PEDS1840"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21) Din\u00e7er A, Yildiz E, Kohan S, Memet \u00d6zek M: Analysis of endoscopic third ventriculostomy patency by MRI: value of different pulse sequences, the sequence parameters, and the imaging planes for investigation of flow void. <i>Childs Nerv Syst<\/i> 27: 127\u2013135, 2011","DOI":"10.1007\/s00381-010-1219-6"},{"key":"22","unstructured":"22) Fukuhara T, Vorster SJ, Ruggieri P, Luciano MG: Third ventriculostomy patency: comparison of findings at cine phase-contrast MR imaging and at direct exploration. <i>AJNR Am J Neuroradiol<\/i> 20: 1560\u20131566, 1999"},{"key":"23","unstructured":"23) Bargall\u00f3 N, Olondo L, Garcia AI, Capurro S, Caral L, Rumia J: Functional analysis of third ventriculostomy patency by quantification of CSF stroke volume by using cine phase-contrast MR imaging. <i>AJNR Am J Neuroradiol<\/i> 26: 2514\u20132521, 2005"},{"key":"24","unstructured":"24) Algin O, Ucar M, Ozmen E, et al.: Assessment of third ventriculostomy patency with the 3D-SPACE technique: a preliminary multicenter research study. <i>J Neurosurg<\/i> 122: 1347\u20131355, 2015"},{"key":"25","unstructured":"25) Abe K, Ono Y, Yoneyama H, et al.: Assessment of cerebrospinal fluid flow patterns using the time-spatial labeling inversion pulse technique with 3T MRI: early clinical experiences. <i>Neuroradiol J<\/i> 27: 268\u2013279, 2014"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26) Lucic MA, Koprivsek K, Kozic D, Spero M, Spirovski M, Lucic S: Dynamic magnetic resonance imaging of endoscopic third ventriculostomy patency with differently acquired fast imaging with steady-state precession sequences. <i>Bosn J Basic Med Sci<\/i> 14: 165\u2013170, 2014","DOI":"10.17305\/bjbms.2014.3.37"},{"key":"27","unstructured":"27) Yamada S, Miyazaki M, Kanazawa H, et al.: Visualization of cerebrospinal fluid movement with spin labeling at MR imaging: preliminary results in normal and pathophysiologic conditions. <i>Radiology<\/i> 249: 644\u2013652, 2008"}],"container-title":["Neurologia medico-chirurgica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/nmc\/60\/1\/60_oa.2019-0170\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,1,18]],"date-time":"2020-01-18T03:29:57Z","timestamp":1579318197000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/nmc\/60\/1\/60_oa.2019-0170\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020]]},"references-count":27,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.2176\/nmc.oa.2019-0170","relation":{},"ISSN":["0470-8105","1349-8029"],"issn-type":[{"value":"0470-8105","type":"print"},{"value":"1349-8029","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020]]}}}