{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T08:02:32Z","timestamp":1783584152462,"version":"3.55.0"},"reference-count":29,"publisher":"Japan Neurosurgical Society","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Neurol. Med. Chir.(Tokyo)"],"published-print":{"date-parts":[[2020]]},"DOI":"10.2176\/nmc.oa.2020-0206","type":"journal-article","created":{"date-parts":[[2020,11,17]],"date-time":"2020-11-17T22:12:13Z","timestamp":1605651133000},"page":"40-46","source":"Crossref","is-referenced-by-count":5,"title":["Risk Factor Analysis of Facet Fusion Following Cervical Lateral Mass Screw Fixation with a Minimum 1-Year Follow-up: Assessment of Maximal Insertional Screw Torque and Incidence of Loosening"],"prefix":"10.2176","volume":"61","author":[{"given":"Ryo","family":"KANEMATSU","sequence":"first","affiliation":[{"name":"Department of Spinal Disorders Center, Fujieda Heisei Memorial Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junya","family":"HANAKITA","sequence":"additional","affiliation":[{"name":"Department of Spinal Disorders Center, Fujieda Heisei Memorial Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiyuki","family":"TAKAHASHI","sequence":"additional","affiliation":[{"name":"Department of Spinal Disorders Center, Fujieda Heisei Memorial Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manabu","family":"MINAMI","sequence":"additional","affiliation":[{"name":"Department of Spinal Disorders Center, Fujieda Heisei Memorial Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomoo","family":"INOUE","sequence":"additional","affiliation":[{"name":"Department of Spinal Disorders Center, Fujieda Heisei Memorial Hospital"},{"name":"Department of Neurosurgery, Kitasato University School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fumiaki","family":"HONDA","sequence":"additional","affiliation":[{"name":"Department of Spinal Disorders Center, Fujieda Heisei Memorial Hospital"},{"name":"Department of Neurosurgery, Gunma University Graduate School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"971","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1) Galbusera F, Volkheimer D, Reitmaier S, Berger-Roscher N, Kienle A, Wilke HJ: Pedicle screw loosening: a clinically relevant complication? <i>Eur Spine J<\/i> 24: 1005\u20131016, 2015","DOI":"10.1007\/s00586-015-3768-6"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2) Okuyama K, Abe E, Suzuki T, Tamura Y, Chiba M, Sato K: Can insertional torque predict screw loosening and related failures? An in vivo study of pedicle screw fixation augmenting posterior lumbar interbody fusion. <i>Spine<\/i> 25: 858\u2013864, 2000","DOI":"10.1097\/00007632-200004010-00015"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3) Jeanneret B, Magerl F, Ward EH, Ward JC: Posterior stabilization of the cervical spine with hook plates. <i>Spine<\/i> 16: S56\u2013S63, 1991","DOI":"10.1097\/00007632-199103001-00010"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4) Kwok AW, Finkelstein JA, Woodside T, Hearn TC, Hu RW: Insertional torque and pull-out strengths of conical and cylindrical pedicle screws in cadaveric bone. <i>Spine<\/i> 21: 2429\u20132434, 1996","DOI":"10.1097\/00007632-199611010-00004"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5) Hilibrand AS, Robbins M: Adjacent segment degeneration and adjacent segment disease: the consequences of spinal fusion? <i>Spine<\/i> J 4: 190S\u2013194S, 2004","DOI":"10.1016\/j.spinee.2004.07.007"},{"key":"6","unstructured":"6) Coe JD, Vaccaro AR, Dailey AT, et al.: Lateral mass screw fixation in the cervical spine: a systematic literature review. <i>J Bone Joint Surg Am<\/i> 95: 2136\u20132143, 2013"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7) Muffoletto AJ, Yang J, Vadhva M, Hadjipavlou AG: Cervical stability with lateral mass plating: unicortical versus bicortical screw purchase. <i>Spine<\/i> 28: 778\u2013781, 2003","DOI":"10.1097\/01.BRS.0000058938.57588.78"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8) Seybold EA, Baker JA, Criscitiello AA, Ordway NR, Park CK, Connolly PJ: Characteristics of unicortical and bicortical lateral mass screws in the cervical spine. <i>Spine<\/i> 24: 2397\u20132403, 1999","DOI":"10.1097\/00007632-199911150-00018"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9) Heller JG, Estes BT, Zaouali M, Diop A: Biomechanical study of screws in the lateral masses: variables affecting pull-out resistance. <i>J Bone Joint Surg Am<\/i> 78: 1315\u20131321, 1996","DOI":"10.2106\/00004623-199609000-00004"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10) Cho KH, Shin YS, Yoon SH, Kim SH, Ahn YH, Cho KG: Poor surgical technique in cervical plating leading to vertebral artery injury and brain stem infarction--case report. <i>Surg Neurol<\/i> 64: 221\u2013225, 2005","DOI":"10.1016\/j.surneu.2004.09.042"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11) Zindrick MR, Wiltse LL, Widell EH, et al.: A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. <i>Clin Orthop Relat Res<\/i> 203: 99\u2013112, 1986","DOI":"10.1097\/00003086-198602000-00012"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12) Mizuno K, Shinomiya K, Nakai O, Shindo S, Otani K: Intraoperative insertion torque of lumbar pedicle screw and postoperative radiographic evaluation: short-term observation. <i>J Orthop Sci<\/i> 10: 137\u2013144, 2005","DOI":"10.1007\/s00776-004-0873-5"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13) Lee JH, Lee J-H, Park JW, Shin YH: The insertional torque of a pedicle screw has a positive correlation with bone mineral density in posterior lumbar pedicle screw fixation. <i>J Bone Joint Surg Br<\/i> 94: 93\u201397, 2012","DOI":"10.1302\/0301-620X.94B1.27032"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14) Ozawa T, Takahashi K, Yamagata M, et al.: Insertional torque of the lumbar pedicle screw during surgery. <i>J Orthop Sci<\/i> 10: 133\u2013136, 2005","DOI":"10.1007\/s00776-004-0883-3"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15) Lovick DS, Ryken TC, Traynelis VC, Dexter F: Assessment of primary and salvage lateral mass screw insertion torque in a cadaveric model. <i>J Spinal Disord<\/i> 10: 431\u2013435, 1997","DOI":"10.1097\/00002517-199710000-00012"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16) Reitman CA, Nguyen L, Fogel GR: Biomechanical evaluation of relationship of screw pullout strength, insertional torque, and bone mineral density in the cervical spine. <i>J Spinal Disord Tech<\/i> 17: 306\u2013311, 2004","DOI":"10.1097\/01.bsd.0000090575.08296.9d"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17) Ono A, Brown MD, Latta LL, Milne EL, Holmes DC: Triangulated pedicle screw construct technique and pull-out strength of conical and cylindrical screws. <i>J Spinal Disord<\/i> 14: 323\u2013329, 2001","DOI":"10.1097\/00002517-200108000-00007"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18) Gracco A, Giagnorio C, Incerti Parenti S, Alessandri Bonetti G, Siciliani G: Effects of thread shape on the pullout strength of miniscrews. <i>Am J Orthod Dentofacial Orthop<\/i> 142: 186\u2013190, 2012","DOI":"10.1016\/j.ajodo.2012.03.023"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19) B\u00fchler DW, Berlemann U, Oxland TR, Nolte LP: Moments and forces during pedicle screw insertion. In vitro and in vivo measurements. <i>Spine<\/i> 23: 1220\u20131227 discussion 1228, 1998","DOI":"10.1097\/00007632-199806010-00009"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20) Christensen FB, Dalstra M, Sejling F, Overgaard S, B\u00fcnger C: Titanium-alloy enhances bone-pedicle screw fixation: mechanical and histomorphometrical results of titanium-alloy versus stainless steel. <i>Eur Spine J<\/i> 9: 97\u2013103, 2000","DOI":"10.1007\/s005860050218"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21) Misenhimer GR, Peek RD, Wiltse LL, Rothman SL, Widell EH: Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size. <i>Spine<\/i> 14: 367\u2013372, 1989","DOI":"10.1097\/00007632-198904000-00004"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22) Krag MH, Beynnon BD, Pope MH, DeCoster TA: Depth of insertion of transpedicular vertebral screws into human vertebrae: effect upon screw-vertebra interface strength. <i>J Spinal Disord<\/i> 1: 287\u2013294, 1988","DOI":"10.1097\/00002517-198800140-00002"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23) Kuklo TR, Lehman RA: Effect of various tapping diameters on insertion of thoracic pedicle screws: a biomechanical analysis. <i>Spine<\/i> 28: 2066\u20132071, 2003","DOI":"10.1097\/01.BRS.0000084665.31967.02"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24) Jones EL, Heller JG, Silcox DH, Hutton WC: Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison. <i>Spine<\/i> 22: 977\u2013982, 1997","DOI":"10.1097\/00007632-199705010-00009"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25) Xu R, McGirt MJ, Sutter EG, et al.: Biomechanical comparison between C-7 lateral mass and pedicle screws in subaxial cervical constructs. Presented at the 2009 Joint Spine Meeting. Laboratory investigation. <i>J Neurosurg Spine<\/i> 13: 688\u2013694, 2010","DOI":"10.3171\/2010.5.SPINE09712"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26) Krag MH: Biomechanics of thoracolumbar spinal fixation. A review. <i>Spine<\/i> 16: S84\u2013S99, 1991","DOI":"10.1097\/00007632-199103001-00014"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27) Matsukawa K, Yato Y, Imabayashi H, Asazuma T, Chiba K: Feasibility of using tapping torque during lumbar pedicle screw insertion to predict screw fixation strength. <i>J Orthop Sci<\/i> 25: 389\u2013393, 2020","DOI":"10.1016\/j.jos.2019.05.009"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28) Zdeblick TA, Kunz DN, Cooke ME, McCabe R: Pedicle screw pullout strength. Correlation with insertional torque. <i>Spine<\/i> 18: 1673\u20131676, 1993","DOI":"10.1097\/00007632-199309000-00016"},{"key":"29","doi-asserted-by":"crossref","unstructured":"29) Esses SI, Sachs BL, Dreyzin V: Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. <i>Spine<\/i> 18: 2231\u20132238; discussion 2238-2239, 1993","DOI":"10.1097\/00007632-199311000-00015"}],"container-title":["Neurologia medico-chirurgica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/nmc\/61\/1\/61_oa.2020-0206\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,16]],"date-time":"2021-01-16T03:34:51Z","timestamp":1610768091000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/nmc\/61\/1\/61_oa.2020-0206\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.2176\/nmc.oa.2020-0206","relation":{},"ISSN":["0470-8105","1349-8029"],"issn-type":[{"value":"0470-8105","type":"print"},{"value":"1349-8029","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020]]}}}