{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,19]],"date-time":"2026-04-19T17:53:38Z","timestamp":1776621218896,"version":"3.51.2"},"reference-count":35,"publisher":"Japan Prosthodontic Society","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Prosthodont Res"],"published-print":{"date-parts":[[2022]]},"DOI":"10.2186\/jpr.jpr_d_22_00108","type":"journal-article","created":{"date-parts":[[2022,11,11]],"date-time":"2022-11-11T22:12:20Z","timestamp":1668204740000},"page":"430-436","source":"Crossref","is-referenced-by-count":7,"title":["Stress distribution of one-piece and two-piece mini-Implant overdentures with various attachment systems and diameters: A finite element analysis"],"prefix":"10.2186","volume":"67","author":[{"given":"Bui Ngoc Huyen","family":"Trang","sequence":"first","affiliation":[{"name":"Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manabu","family":"Kanazawa","sequence":"additional","affiliation":[{"name":"Digital Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Natsuko","family":"Murakami","sequence":"additional","affiliation":[{"name":"Advanced Prosthodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Noriyuki","family":"Wakabayashi","sequence":"additional","affiliation":[{"name":"Advanced Prosthodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tamaki","family":"Hada","sequence":"additional","affiliation":[{"name":"Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Namano","family":"Sahaprom","sequence":"additional","affiliation":[{"name":"Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Japan"},{"name":"Dental Hospital, Faculty of Dentistry, Chulalongkorn University, Thailand"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuriko","family":"Komagamine","sequence":"additional","affiliation":[{"name":"Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shunsuke","family":"Minakuchi","sequence":"additional","affiliation":[{"name":"Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"996","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"[1] Kutkut A,Bertoli E,Frazer R,Pinto-Sinai G,Fuentealba Hidalgo R,Studts J. A systematic review of studies comparing conventional complete denture and implant retained overdenture. J Prosthodont Res. 2018;62:1\u20139. https:\/\/doi.org\/10.1016\/j.jpor.2017.06.004 PMID:28666845","DOI":"10.1016\/j.jpor.2017.06.004"},{"key":"2","doi-asserted-by":"crossref","unstructured":"[2] Harris D,H\u00f6fer S,O\u2019Boyle CA,Sheridan S,Marley J,Benington IC,<i>et al.<\/i> A comparison of implant-retained mandibular overdentures and conventional dentures on quality of life in edentulous patients: a randomized, prospective, within-subject controlled clinical trial. Clin Oral Implants Res. 2013;24:96\u2013103. https:\/\/doi.org\/10.1111\/j.1600-0501.2011.02368.x PMID:22111872","DOI":"10.1111\/j.1600-0501.2011.02368.x"},{"key":"3","doi-asserted-by":"crossref","unstructured":"[3] The Glossary of Prosthodontic Terms. 9th ed. J Prosthet Dent. 2017;117:e1\u2013ee105.","DOI":"10.1016\/j.prosdent.2016.12.001"},{"key":"4","doi-asserted-by":"crossref","unstructured":"[4] Hasan I,Bourauel C,Mundt T,Stark H,Heinemann F. Biomechanics and load resistance of small-diameter and mini dental implants: a review of literature. Biomed Tech (Berl). 2014;59:1\u20135. https:\/\/doi.org\/10.1515\/bmt-2013-0092 PMID:24293447","DOI":"10.1515\/bmt-2013-0092"},{"key":"5","doi-asserted-by":"crossref","unstructured":"[5] Tada S,Kanazawa M,Miyayasu A,Iwaki M,Srinivasan M,Minakuchi S,<i>et al.<\/i> Patient preferences for different tooth replacement strategies for the edentulous mandible: A willingness-to-pay analysis. J Prosthodont Res. 2021;65:535\u201340. https:\/\/doi.org\/10.2186\/jpr.JPR_D_20_00170 PMID:33980785","DOI":"10.2186\/jpr.JPR_D_20_00170"},{"key":"6","doi-asserted-by":"crossref","unstructured":"[6] Griffitts TM,Collins CP,Collins PC. Mini dental implants: an adjunct for retention, stability, and comfort for the edentulous patient. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2005;100:e81\u20134. https:\/\/doi.org\/10.1016\/j.tripleo.2005.06.018 PMID:16243233","DOI":"10.1016\/j.tripleo.2005.06.018"},{"key":"7","doi-asserted-by":"crossref","unstructured":"[7] Schwindling FS,Schwindling FP. Mini dental implants retaining mandibular overdentures: A dental practice-based retrospective analysis. J Prosthodont Res. 2016;60:193\u20138. https:\/\/doi.org\/10.1016\/j.jpor.2015.12.005 PMID:26783089","DOI":"10.1016\/j.jpor.2015.12.005"},{"key":"8","doi-asserted-by":"crossref","unstructured":"[8] Hasan I,Heinemann F,Aitlahrach M,Bourauel C. Biomechanical finite element analysis of small diameter and short dental implant. Biomed Tech (Berl). 2010;55:341\u201350. https:\/\/doi.org\/10.1515\/bmt.2010.049 PMID:21028950","DOI":"10.1515\/bmt.2010.049"},{"key":"9","doi-asserted-by":"crossref","unstructured":"[9] Allum SR,Tomlinson RA,Joshi R. The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study. Clin Oral Implants Res. 2008;19:553\u20139. https:\/\/doi.org\/10.1111\/j.1600-0501.2007.01395.x PMID:18474061","DOI":"10.1111\/j.1600-0501.2007.01395.x"},{"key":"10","doi-asserted-by":"crossref","unstructured":"[10] Jofr\u00e9 J,Hamada T,Nishimura M,Klattenhoff C. The effect of maximum bite force on marginal bone loss of mini-implants supporting a mandibular overdenture: a randomized controlled trial. Clin Oral Implants Res. 2010;21:243\u20139. https:\/\/doi.org\/10.1111\/j.1600-0501.2009.01834.x PMID:20070758","DOI":"10.1111\/j.1600-0501.2009.01834.x"},{"key":"11","doi-asserted-by":"crossref","unstructured":"[11] Klein M,Schiegnitz E,Al-Nawas B. Systematic review on success of narrow-diameter dental implants. Int J Oral Maxillofac Implants. 2014;29(suppl):43\u201354. https:\/\/doi.org\/10.11607\/jomi.2014suppl.g1.3 PMID:24660189","DOI":"10.11607\/jomi.2014suppl.g1.3"},{"key":"12","doi-asserted-by":"crossref","unstructured":"[12] Broggini N,McManus LM,Hermann JS,Medina R,Schenk RK,Buser D,<i>et al.<\/i> Peri-implant inflammation defined by the implant-abutment interface. J Dent Res. 2006;85:473\u20138. https:\/\/doi.org\/10.1177\/154405910608500515 PMID:16632764","DOI":"10.1177\/154405910608500515"},{"key":"13","doi-asserted-by":"crossref","unstructured":"[13] Messias A,Nicolau P,Guerra F. Titanium dental implants with different collar design and surface modifications: A systematic review on survival rates and marginal bone levels. Clin Oral Implants Res. 2019;30:20\u201348. https:\/\/doi.org\/10.1111\/clr.13389 PMID:30466192","DOI":"10.1111\/clr.13389"},{"key":"14","doi-asserted-by":"crossref","unstructured":"[14] Khurana N,Rodrigues S,Shenoy S,Saldanha S,Pai U,Shetty T,<i>et al.<\/i> A comparative evaluation of stress distribution with two attachment systems of varying heights in a mandibular implant-supported overdenture: A three-dimensional finite element analysis. J Prosthodont. 2019;28:e795\u2013805. https:\/\/doi.org\/10.1111\/jopr.12966 PMID:30191668","DOI":"10.1111\/jopr.12966"},{"key":"15","doi-asserted-by":"crossref","unstructured":"[15] Heckmann SM,Wichmann MG,Winter W,Meyer M,Weber H-P. Overdenture attachment selection and the loading of implant and denture-bearing area. Part 2: A methodical study using five types of attachment. Clin Oral Implants Res. 2001;12:640\u20137. https:\/\/doi.org\/10.1034\/j.1600-0501.2001.120613.x PMID:11737109","DOI":"10.1034\/j.1600-0501.2001.120613.x"},{"key":"16","doi-asserted-by":"crossref","unstructured":"[16] Cheng T,Sun G,Huo J,He X,Wang Y,Ren YF. Patient satisfaction and masticatory efficiency of single implant-retained mandibular overdentures using the stud and magnetic attachments. J Dent. 2012;40:1018\u201323. https:\/\/doi.org\/10.1016\/j.jdent.2012.08.011 PMID:22925922","DOI":"10.1016\/j.jdent.2012.08.011"},{"key":"17","doi-asserted-by":"crossref","unstructured":"[17] Wu AYJ,Hsu JT,Chee W,Lin YT,Fuh LJ,Huang HL. Biomechanical evaluation of one-piece and two-piece small-diameter dental implants: in-vitro experimental and three-dimensional finite element analyses. J Formos Med Assoc. 2016;115:794\u2013800. https:\/\/doi.org\/10.1016\/j.jfma.2016.01.002 PMID:27013111","DOI":"10.1016\/j.jfma.2016.01.002"},{"key":"18","unstructured":"[18] Aunmeungtong W,Khongkhunthian P,Rungsiyakull P. Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study. Oral Implantol (Rome). 2016;9:202\u201312. PMID:28042449"},{"key":"19","doi-asserted-by":"crossref","unstructured":"[19] Hu F,Gong Y,Bian Z,Zhang X,Xu B,Zhang J,<i>et al.<\/i> Comparison of three different types of two-implant-supported magnetic attachments on the stress distribution in edentulous mandible. Comput Math Methods Med. 2019;2019:1\u201310. https:\/\/doi.org\/10.1155\/2019\/6839517 PMID:31089390","DOI":"10.1155\/2019\/6839517"},{"key":"20","doi-asserted-by":"crossref","unstructured":"[20] Meijer HA,Starmans FJM,Steen WHA,Bosman F. Loading conditions of endosseous implants in an edentulous human mandible: a three\u2010dimensional, finite\u2010element study. J Oral Rehabil. 1996;23:757\u201363. https:\/\/doi.org\/10.1046\/j.1365-2842.1996.d01-185.x PMID:8953480","DOI":"10.1046\/j.1365-2842.1996.d01-185.x"},{"key":"21","doi-asserted-by":"crossref","unstructured":"[21] Katranji A,Misch K,Wang HL. Cortical bone thickness in dentate and edentulous human cadavers. J Periodontol. 2007;78:874\u20138. https:\/\/doi.org\/10.1902\/jop.2007.060342 PMID:17470021","DOI":"10.1902\/jop.2007.060342"},{"key":"22","doi-asserted-by":"crossref","unstructured":"[22] Dong J,Zhang FY,Wu GH,Zhang W,Yin J. Measurement of mucosal thickness in denture-bearing area of edentulous mandible. Chin Med J (Engl). 2015;128:342\u20137. https:\/\/doi.org\/10.4103\/0366-6999.150100 PMID:25635429","DOI":"10.4103\/0366-6999.150100"},{"key":"23","doi-asserted-by":"crossref","unstructured":"[23] Barbier L,Sloten JV,Krzesinski G,Schepers E,Van der Perre G. Finite element analysis of non\u2010axial versus axial loading of oral implants in the mandible of the dog. J Oral Rehabil. 1998;25:847\u201358. https:\/\/doi.org\/10.1046\/j.1365-2842.1998.00318.x PMID:9846905","DOI":"10.1046\/j.1365-2842.1998.00318.x"},{"key":"24","doi-asserted-by":"crossref","unstructured":"[24] Bar\u00e3o VAR,Delben JA,Lima J,Cabral T,Assun\u00e7\u00e3o WG. Comparison of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible \u2013 A computed tomography-based three-dimensional finite element analysis. J Biomech. 2013;46:1312\u201320. https:\/\/doi.org\/10.1016\/j.jbiomech.2013.02.008 PMID:23518207","DOI":"10.1016\/j.jbiomech.2013.02.008"},{"key":"25","doi-asserted-by":"crossref","unstructured":"[25] Daas M,Dubois G,Bonnet AS,Lipinski P,Rignon-Bret C. A complete finite element model of a mandibular implant-retained overdenture with two implants: comparison between rigid and resilient attachment configurations. Med Eng Phys. 2008;30:218\u201325. https:\/\/doi.org\/10.1016\/j.medengphy.2007.02.005 PMID:17383925","DOI":"10.1016\/j.medengphy.2007.02.005"},{"key":"26","unstructured":"[26] Collings EW. The physical metallurgy of titanium alloys, vol. xxii. Metals Park, Ohio: American Society for Metals; 1984, 261 p. p."},{"key":"27","doi-asserted-by":"crossref","unstructured":"[27] Lahoti K,Pathrabe A,Gade J. Stress analysis at bone-implant interface of single- and two-implant-retained mandibular overdenture using three-dimensional finite element analysis. Indian J Dent Res. 2016;27:597\u2013601. https:\/\/doi.org\/10.4103\/0970-9290.199587 PMID:28169256","DOI":"10.4103\/0970-9290.199587"},{"key":"28","doi-asserted-by":"crossref","unstructured":"[28] Chun HJ,Park DN,Han CH,Heo SJ,Heo MS,Koak JY. Stress distributions in maxillary bone surrounding overdenture implants with different overdenture attachments. J Oral Rehabil. 2005;32:193\u2013205. https:\/\/doi.org\/10.1111\/j.1365-2842.2004.01407.x PMID:15707430","DOI":"10.1111\/j.1365-2842.2004.01407.x"},{"key":"29","doi-asserted-by":"crossref","unstructured":"[29] Cavit Cehreli M,Ak\u00e7a K,Iplik\u00e7io\u011flu H. Force transmission of one- and two-piece morse-taper oral implants: a nonlinear finite element analysis. Clin Oral Implants Res. 2004;15:481\u20139. https:\/\/doi.org\/10.1111\/j.1600-0501.2004.01025.x PMID:15248884","DOI":"10.1111\/j.1600-0501.2004.01025.x"},{"key":"30","doi-asserted-by":"crossref","unstructured":"[30] Pilliar RM,Lee JM,Maniatopoulos C. Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop Relat Res. 1986;208:108\u201313. https:\/\/doi.org\/10.1111\/j.1600-0501.2004.01025.x PMID:15248884","DOI":"10.1097\/00003086-198607000-00023"},{"key":"31","doi-asserted-by":"crossref","unstructured":"[31] Szmukler-Moncler S,Salama H,Reingewirtz Y,Dubruille JH. Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. J Biomed Mater Res. 1998;43:192\u2013203. https:\/\/doi.org\/10.1002\/(SICI)1097-4636(199822)43:2&lt;192::AID-JBM14&gt;3.0.CO;2-K PMID:9619438","DOI":"10.1002\/(SICI)1097-4636(199822)43:2<192::AID-JBM14>3.0.CO;2-K"},{"key":"32","doi-asserted-by":"crossref","unstructured":"[32] Chen IC,Brudvik JS,Mancl LA,Rubenstein JE,Chitswe K,Raigrodski AJ. Freedom of rotation of selected overdenture attachments: an in vitro study. J Prosthet Dent. 2011;106:78\u201386. https:\/\/doi.org\/10.1016\/S0022-3913(11)60099-1 PMID:21821161","DOI":"10.1016\/S0022-3913(11)60099-1"},{"key":"33","doi-asserted-by":"crossref","unstructured":"[33] Turker N,Buyukkaplan US. Effects of overdenture attachment systems with different working principles on stress transmission: A three-dimensional finite element study. J Adv Prosthodont. 2020;12:351\u201360. https:\/\/doi.org\/10.4047\/jap.2020.12.6.351 PMID:33489019","DOI":"10.4047\/jap.2020.12.6.351"},{"key":"34","doi-asserted-by":"crossref","unstructured":"[34] Cakarer S,Can T,Yaltirik M,Keskin C. Complications associated with the ball, bar and Locator attachments for implant-supported overdentures. Med Oral Patol Oral Cir Bucal. 2011;16:e953\u20139. https:\/\/doi.org\/10.4317\/medoral.17312 PMID:21743398","DOI":"10.4317\/medoral.17312"},{"key":"35","doi-asserted-by":"crossref","unstructured":"[35] Toyoshima Y,Wakabayashi N. Load limit of mini-implants with reduced abutment height based on fatigue fracture resistance: experimental and finite element study. Int J Oral Maxillofac Implants. 2015;30:e10\u20136. https:\/\/doi.org\/10.11607\/jomi.3653 PMID:25506647","DOI":"10.11607\/jomi.3653"}],"container-title":["Journal of Prosthodontic Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jpr\/67\/3\/67_JPR_D_22_00108\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,13]],"date-time":"2024-05-13T04:49:59Z","timestamp":1715575799000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jpr\/67\/3\/67_JPR_D_22_00108\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022]]},"references-count":35,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.2186\/jpr.jpr_d_22_00108","relation":{},"ISSN":["1883-1958","1883-9207"],"issn-type":[{"value":"1883-1958","type":"print"},{"value":"1883-9207","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022]]},"article-number":"JPR_D_22_00108"}}