{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,7]],"date-time":"2025-08-07T21:18:54Z","timestamp":1754601534378,"version":"3.27.0"},"reference-count":36,"publisher":"Japan Prosthodontic Society","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Prosthodont Res"],"published-print":{"date-parts":[[2024]]},"DOI":"10.2186\/jpr.jpr_d_23_00005","type":"journal-article","created":{"date-parts":[[2024,6,25]],"date-time":"2024-06-25T22:10:12Z","timestamp":1719353412000},"page":"624-633","source":"Crossref","is-referenced-by-count":2,"title":["Partial fixed dental prostheses fabricated using fiber-reinforced composite          resin supported by short and extra-short implants: A case series"],"prefix":"10.2186","volume":"68","author":[{"given":"Yu-Chi","family":"Cheng","sequence":"first","affiliation":[{"name":"Harvard School of Dental Medicine, Boston, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Estevam A.","family":"Bonfante","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics and Periodontology, University of Sao Paulo \u2013              Bauru School of Dentistry, Bauru, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Edmara T.P.","family":"Bergamo","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics and Periodontology, University of Sao Paulo \u2013              Bauru School of Dentistry, Bauru, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rolf","family":"Ewers","sequence":"additional","affiliation":[{"name":"University Hospital for Cranio-Maxillofacial and Oral Surgery and CMF              Institute Vienna, Vienna, Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"996","reference":[{"unstructured":"[1]  Abou-Ayash S,Strasding M,R\u00fccker G,Att W. Impact          of prosthetic material on mid- and long-term outcome of dental implants supporting single          crowns and fixed partial dentures: A systematic review and meta-analysis. Eur J Oral          Implantology. 2017;10(suppl 1):47\u201365. PMID:28944368","key":"1"},{"doi-asserted-by":"crossref","unstructured":"[2]  Sailer I,Strasding M,Valente NA,Zwahlen M,Liu          S,Pjetursson BE. A systematic review of the survival and complication rates of          zirconia\u2010ceramic and metal\u2010ceramic multiple\u2010unit fixed dental prostheses. Clin Oral          Implants Res. 2018;29(suppl 16):184\u201398. https:\/\/doi.org\/10.1111\/clr.13277          PMID:30328185","key":"2","DOI":"10.1111\/clr.13277"},{"doi-asserted-by":"crossref","unstructured":"[3]  Pieralli S,Kohal RJ,Rabel K,von Stein-Lausnitz          M,Vach K,Spies BC. Clinical outcomes of partial and full\u2010arch all\u2010ceramic          implant\u2010supported fixed dental prostheses. A systematic review and meta\u2010analysis. Clin          Oral Implants Res. 2018;29(suppl 18):224\u201336. https:\/\/doi.org\/10.1111\/clr.13345          PMID:30306694","key":"3","DOI":"10.1111\/clr.13345"},{"doi-asserted-by":"crossref","unstructured":"[4]  Ewers R,Marincola M,Perpetuini P,Morina          A,Bergamo ETP,Cheng YC,<i>et al.<\/i> Severely atrophic mandibles restored with          fiber-reinforced composite prostheses supported by 5.0 mm ultra-short implants present          high survival rates up to eight years. J Oral Maxillofac Surg. 2022;80:81\u201392.          https:\/\/doi.org\/10.1016\/j.joms.2021.09.018 PMID:34666033","key":"4","DOI":"10.1016\/j.joms.2021.09.018"},{"doi-asserted-by":"crossref","unstructured":"[5]  Messias A,Nicolau P,Guerra F. Different          interventions for rehabilitation of the edentulous maxilla with implant-supported          prostheses: an overview of systematic reviews. Int J Prosthodont. 2021;34:s63\u201384.          https:\/\/doi.org\/10.11607\/ijp.7162 PMID:33571327","key":"5","DOI":"10.11607\/ijp.7162"},{"doi-asserted-by":"crossref","unstructured":"[6]  de Oliveira Lino LF,Machado CM,de Paula          VG,Vidotti HA,Coelho PG,Benalc\u00e1zar Jalkh EB,<i>et al.<\/i> Effect of aging and          testing method on bond strength of CAD\/CAM fiber-reinforced composite to dentin. Dent          Mater. 2018;34:1690\u2013701. https:\/\/doi.org\/10.1016\/j.dental.2018.08.302          PMID:30220508","key":"6","DOI":"10.1016\/j.dental.2018.08.302"},{"doi-asserted-by":"crossref","unstructured":"[7]  Suzaki N,Yamaguchi S,Hirose N,Tanaka R,Takahashi          Y,Imazato S,<i>et al.<\/i> Evaluation of physical properties of fiber-reinforced          composite resin. Dent Mater. 2020;36:987\u201396. https:\/\/doi.org\/10.1016\/j.dental.2020.04.012          PMID:32546399","key":"7","DOI":"10.1016\/j.dental.2020.04.012"},{"doi-asserted-by":"crossref","unstructured":"[8]  Biri\u0219 C,Bechir ES,Bechir A,Mola FC,Caraiane          A,Badiu AV,<i>et al.<\/i> Trinia reinforced polymer as core for implants          superstructure. Mater Plast. 2017;54:762\u20137.          https:\/\/doi.org\/10.37358\/MP.17.4.4941","key":"8","DOI":"10.37358\/MP.17.4.4941"},{"doi-asserted-by":"crossref","unstructured":"[9]  Erkmen E,Meri\u00e7 G,Kurt A,Tun\u00e7 Y,Eser A.          Biomechanical comparison of implant retained fixed partial dentures with fiber reinforced          composite versus conventional metal frameworks: A 3D FEA study. J Mech Behav Biomed Mater.          2011;4:107\u201316. https:\/\/doi.org\/10.1016\/j.jmbbm.2010.09.011 PMID:21094484","key":"9","DOI":"10.1016\/j.jmbbm.2010.09.011"},{"unstructured":"[10]  Ciarmatori E,Passaretti A,Miracolo G,Cicconetti          A. Critical review of literature on the use of short implants. J Osseointegration.          2018;10:87\u201394. https:\/\/doi.org\/10.23805\/jo.2018.10.03.04","key":"10"},{"doi-asserted-by":"crossref","unstructured":"[11]  do Prado Ribeiro P,Goiato MC,Pellizzer          EP,Pesqueira AA,Haddad MF,Alves-Rezende MCR,<i>et al.<\/i> Photoelastic stress          analysis of different attachment systems on implant-retained and conventional palatal          obturator prostheses. J Craniofac Surg. 2011;22:523\u20136.          https:\/\/doi.org\/10.1097\/SCS.0b013e3182085401 PMID:21403545","key":"11","DOI":"10.1097\/SCS.0b013e3182085401"},{"doi-asserted-by":"crossref","unstructured":"[12]  Al-Johany SS,Al Amri MD,Alsaeed S,Alalola B.          Dental implant length and diameter: A proposed classification scheme. J Prosthodont.          2017;26:252\u201360. https:\/\/doi.org\/10.1111\/jopr.12517 PMID:27379723","key":"12","DOI":"10.1111\/jopr.12517"},{"doi-asserted-by":"crossref","unstructured":"[13]  Cheng YC,Bergamo ETP,Murcko L,Hirayama          M,Perpetuini P,Speratti D,<i>et al.<\/i> Fiber\u2010reinforced composite partial fixed          dental prostheses supported by short or extra\u2010short implants: A 10 year retrospective          study. Clin Implant Dent Relat Res. 2022;24:854\u201361. https:\/\/doi.org\/10.1111\/cid.13133          PMID:36205843","key":"13","DOI":"10.1111\/cid.13133"},{"doi-asserted-by":"crossref","unstructured":"[14]  Rossi F,Lang NP,Ricci E,Ferraioli L,Marchetti          C,Botticelli D. 6\u2010mm\u2010long implants loaded with fiber\u2010reinforced composite resin\u2010bonded          fixed prostheses ( FRCRBFDP s). A 5\u2010year prospective study. Clin Oral Implants Res.          2017;28:1478\u201383. https:\/\/doi.org\/10.1111\/clr.13015 PMID:28370406","key":"14","DOI":"10.1111\/clr.13015"},{"doi-asserted-by":"crossref","unstructured":"[15]  Vandenbroucke JP,von Elm E,Altman DG,G\u00f8tzsche          PC,Mulrow CD,Pocock SJ,<i>et al.<\/i>; STROBE initiative. Strengthening the          Reporting of Observational Studies in Epidemiology (STROBE): explanation and Elaboration.          Ann Intern Med. 2007;147:W. https:\/\/doi.org\/10.7326\/0003-4819-147-8-200710160-00010-w1          PMID:17938389","key":"15","DOI":"10.7326\/0003-4819-147-8-200710160-00010-w1"},{"doi-asserted-by":"crossref","unstructured":"[16]  Persson RE,Tzannetou S,Feloutzis AG,Br\u00e4gger          U,Persson GR,Lang NP. Comparison between panoramic and intra\u2010oral radiographs for the          assessment of alveolar bone levels in a periodontal maintenance population. J Clin          Periodontol. 2003;30:833\u20139. https:\/\/doi.org\/10.1034\/j.1600-051X.2003.00379.x          PMID:12956660","key":"16","DOI":"10.1034\/j.1600-051X.2003.00379.x"},{"doi-asserted-by":"crossref","unstructured":"[17]  Takeshita W,Vessoni Iwaki L,Da Silva M,Tonin R.          Evaluation of diagnostic accuracy of conventional and digital periapical radiography,          panoramic radiography, and cone-beam computed tomography in the assessment of alveolar          bone loss. Contemp Clin Dent. 2014;5:318\u201323. https:\/\/doi.org\/10.4103\/0976-237X.137930          PMID:25191066","key":"17","DOI":"10.4103\/0976-237X.137930"},{"doi-asserted-by":"crossref","unstructured":"[18]  Kang MH,Jung UW,Cho KS,Lee JS. Retrospective          radiographic observational study of 1692 Straumann tissue\u2010level dental implants over 10          years. II. Marginal bone stability. Clin Implant Dent Relat Res. 2018;20:875\u201381.          https:\/\/doi.org\/10.1111\/cid.12636 PMID:30048038","key":"18","DOI":"10.1111\/cid.12636"},{"doi-asserted-by":"crossref","unstructured":"[19]  Misch CE,Perel ML,Wang HL,Sammartino          G,Galindo-Moreno P,Trisi P,<i>et al.<\/i> Implant Success, Survival, and Failure:          The International Congress of Oral Implantologists (ICOI) Pisa Consensus Conference.          Implant Dent. 2008;17:5\u201315. https:\/\/doi.org\/10.1097\/ID.0b013e3181676059          PMID:18332753","key":"19","DOI":"10.1097\/ID.0b013e3181676059"},{"doi-asserted-by":"crossref","unstructured":"[20]  Lin DY,Wei LJ. The robust inference for the Cox          proportional hazards model. J Am Stat Assoc. 1989;84:1074\u20138.          https:\/\/doi.org\/10.1080\/01621459.1989.10478874","key":"20","DOI":"10.1080\/01621459.1989.10478874"},{"doi-asserted-by":"crossref","unstructured":"[21]  Pjetursson BE,Thoma D,Jung R,Zwahlen M,Zembic A.          A systematic review of the survival and complication rates of implant\u2010supported fixed          dental prostheses ( FDP s) after a mean observation period of at least 5 years. Clin Oral          Implants Res. 2012;23(suppl 6):22\u201338. https:\/\/doi.org\/10.1111\/j.1600-0501.2012.02546.x          PMID:23062125","key":"21","DOI":"10.1111\/j.1600-0501.2012.02546.x"},{"doi-asserted-by":"crossref","unstructured":"[22]  Bonfante EA,Suzuki M,Carvalho RM,Hirata          R,Lubelski W,Bonfante G,<i>et al.<\/i> Digitally produced fiber-reinforced          composite substructures for three-unit implant-supported fixed dental prostheses. Int J          Oral Maxillofac Implants. 2015;30:321\u20139. https:\/\/doi.org\/10.11607\/jomi.3892          PMID:25830392","key":"22","DOI":"10.11607\/jomi.3892"},{"unstructured":"[23]  Urdaneta RA,Daher S,Leary J,Emanuel KM,Chuang          S-K. The survival of ultrashort locking-taper implants. Int J Oral Maxillofac Implants.          2012;27:644\u201354. PMID:22616059","key":"23"},{"doi-asserted-by":"crossref","unstructured":"[24]  Suresh S,Markose J,Eshwar S,Rekha K,Jain V,Manvi          S. Comparison of platform switched and sloping shoulder implants on stress reduction in          various bone densities: finite element analysis. J Contemp Dent Pract. 2017;18:510\u20135.          https:\/\/doi.org\/10.5005\/jp-journals-10024-2075 PMID:28621284","key":"24","DOI":"10.5005\/jp-journals-10024-2075"},{"unstructured":"[25]  Chou H-Y,Romanos G,M\u00fcft\u00fc A,M\u00fcft\u00fc S. Peri-implant          bone remodeling around an extraction socket: predictions of bone maintenance by finite          element method. Int J Oral Maxillofac Implants. 2012;27:e39\u201348.          PMID:22848899","key":"25"},{"doi-asserted-by":"crossref","unstructured":"[26]  Bozkaya D,Muftu S,Muftu A. Evaluation of load          transfer characteristics of five different implants in compact bone at different load          levels by finite elements analysis. J Prosthet Dent. 2004;92:523\u201330.          https:\/\/doi.org\/10.1016\/j.prosdent.2004.07.024 PMID:15583556","key":"26","DOI":"10.1016\/j.prosdent.2004.07.024"},{"unstructured":"[27]  Magee AC,Perpetuini P,Bonfante EA,Mitchell JC.          Photoelastic analysis of fiber-reinforced composite implant supported dentures n.d.          https:\/\/azkasresearchday-midwestern.ipostersessions.com\/?s=74-ED-BB-6B-91-B5-E9-88-DB-52-62-6D-C3-26-42-9B          (accessed January 3, 2023).","key":"27"},{"doi-asserted-by":"crossref","unstructured":"[28]  Urdaneta RA,Leary J,Panetta KM,Chuang SK. The          effect of opposing structures, natural teeth vs. implants on crestal bone levels          surrounding single\u2010tooth implants. Clin Oral Implants Res. 2014;25:e179\u201388.          https:\/\/doi.org\/10.1111\/clr.12087 PMID:23278549","key":"28","DOI":"10.1111\/clr.12087"},{"unstructured":"[29]  Urdaneta RA,Daher S,Lery J,Emanuel K,Chuang S-K.          Factors associated with crestal bone gain on single-tooth locking-taper implants: the          effect of nonsteroidal anti-inflammatory drugs. Int J Oral Maxillofac Implants.          2011;26:1063\u201378. PMID:22010091","key":"29"},{"doi-asserted-by":"crossref","unstructured":"[30]  Lombardo G,Signoriello A,Pardo A,Serpa Romero          XZ,Vila Sierra LA,Ar\u00e9valo Tovar L,<i>et al.<\/i> Short and ultra\u2010short (&lt;6\u2010mm)          locking\u2010taper implants supporting single crowns in posterior areas (part II ): A 5\u2010year          retrospective study on periodontally healthy patients and patients with a history of          periodontitis. Clin Implant Dent Relat Res. 2022;24:455\u201367.          https:\/\/doi.org\/10.1111\/cid.13103 PMID:35635514","key":"30","DOI":"10.1111\/cid.13103"},{"doi-asserted-by":"crossref","unstructured":"[31]  Urdaneta RA,Leary J,Lubelski W,Emanuel KM,Chuang          SK. The effect of implant size 5 \u00d7 8 mm on crestal bone levels around single-tooth          implants. J Periodontol. 2012;83:1235\u201344. https:\/\/doi.org\/10.1902\/jop.2012.110299          PMID:22309172","key":"31","DOI":"10.1902\/jop.2012.110299"},{"unstructured":"[32]  Lombardo G,Corrocher G,Pighi J,Faccioni F,Rovera          A,Marincola M,<i>et al.<\/i> The impact of subcrestal placement on short          locking-taper implants placed in posterior maxilla and mandible: a retrospective          evaluation on hard and soft tissues stability after 2 years of loading. Minerva Stomatol.          2014;63:391\u2013402. PMID:25503340","key":"32"},{"doi-asserted-by":"crossref","unstructured":"[33]  Tatarakis N,Bashutski J,Wang HL,Oh TJ. Early          implant bone loss: preventable or inevitable? Implant Dent. 2012;21:379\u201386.          https:\/\/doi.org\/10.1097\/ID.0b013e3182665d0c PMID:22983314","key":"33","DOI":"10.1097\/ID.0b013e3182665d0c"},{"unstructured":"[34]  Chung DM,Oh T-J,Lee J,Misch CE,Wang H-L. Factors          affecting late implant bone loss: a retrospective analysis. Int J Oral Maxillofac          Implants. 2007;22:117\u201326. PMID:17340905","key":"34"},{"doi-asserted-by":"crossref","unstructured":"[35]  Vervaeke S,Collaert B,Cosyn J,De Bruyn H. A          9-year prospective case series using multivariate analyses to identify predictors of early          and late peri-implant bone loss. Clin Implant Dent Relat Res. 2016;18:30\u20139.          https:\/\/doi.org\/10.1111\/cid.12255 PMID:24995626","key":"35","DOI":"10.1111\/cid.12255"},{"doi-asserted-by":"crossref","unstructured":"[36]  Ogundimu EO,Altman DG,Collins GS. Adequate          sample size for developing prediction models is not simply related to events per variable.          J Clin Epidemiol. 2016;76:175\u201382. https:\/\/doi.org\/10.1016\/j.jclinepi.2016.02.031          PMID:26964707","key":"36","DOI":"10.1016\/j.jclinepi.2016.02.031"}],"container-title":["Journal of Prosthodontic Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jpr\/68\/4\/68_JPR_D_23_00005\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,19]],"date-time":"2024-10-19T04:55:23Z","timestamp":1729313723000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jpr\/68\/4\/68_JPR_D_23_00005\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"references-count":36,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.2186\/jpr.jpr_d_23_00005","relation":{},"ISSN":["1883-1958","1883-9207"],"issn-type":[{"type":"print","value":"1883-1958"},{"type":"electronic","value":"1883-9207"}],"subject":[],"published":{"date-parts":[[2024]]},"article-number":"JPR_D_23_00005"}}