{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,8]],"date-time":"2026-04-08T23:05:46Z","timestamp":1775689546267,"version":"3.50.1"},"reference-count":29,"publisher":"Japan Prosthodontic Society","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Prosthodont Res"],"published-print":{"date-parts":[[2024]]},"DOI":"10.2186\/jpr.jpr_d_23_00080","type":"journal-article","created":{"date-parts":[[2024,1,11]],"date-time":"2024-01-11T22:12:16Z","timestamp":1705011136000},"page":"466-473","source":"Crossref","is-referenced-by-count":6,"title":["&lt;i&gt;In vitro&lt;\/i&gt; study of optimal removable partial denture clasp design made from novel high-performance polyetherketoneketone"],"prefix":"10.2186","volume":"68","author":[{"given":"Pei-Wen","family":"Peng","sequence":"first","affiliation":[{"name":"School of Dental Technology, Taipei Medical University, Taipei, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"May-Show","family":"Chen","sequence":"additional","affiliation":[{"name":"School of Dentistry, Taipei Medical University, Taipei, Taiwan"},{"name":"Division of Prosthodontics, Department of Dentistry, Taipei Medical University Hospital, Taipei, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tzu-Yu","family":"Peng","sequence":"additional","affiliation":[{"name":"School of Dentistry, Taipei Medical University, Taipei, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peng-Chien","family":"Huang","sequence":"additional","affiliation":[{"name":"School of Dental Technology, Taipei Medical University, Taipei, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroki","family":"Nikawa","sequence":"additional","affiliation":[{"name":"Department of Oral Biology &amp; Engineering, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima City, Hiroshima, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei-Fang","family":"Lee","sequence":"additional","affiliation":[{"name":"School of Dental Technology, Taipei Medical University, Taipei, Taiwan"},{"name":"School of Dentistry, Taipei Medical University, Taipei, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"996","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"[1] Mayinger F,Micovic D,Schleich A,Roos M,Eichberger M,Stawarczyk B. Retention force of polyetheretherketone and cobalt-chrome-molybdenum removable dental prosthesis clasps after artificial aging. Clin Oral Investig. 2021;25:3141\u20139. https:\/\/doi.org\/10.1007\/s00784-020-03642-5 PMID:33064206","DOI":"10.1007\/s00784-020-03642-5"},{"key":"2","doi-asserted-by":"crossref","unstructured":"[2] Arda T,Arikan A. An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps. J Prosthet Dent. 2005;94:267\u201374. https:\/\/doi.org\/10.1016\/j.prosdent.2005.06.009 PMID:16126079","DOI":"10.1016\/j.prosdent.2005.06.009"},{"key":"3","doi-asserted-by":"crossref","unstructured":"[3] Davenport J,Basker R,Heath J,Ralph J,Glantz P. Retention. Br Dent J. 2000;189:646\u201357. https:\/\/doi.org\/10.1038\/sj.bdj.4800854a PMID:11191177","DOI":"10.1038\/sj.bdj.4800854a"},{"key":"4","doi-asserted-by":"crossref","unstructured":"[4] McCracken WL. Contemporary partial denture designs. J Prosthet Dent. 2004;92:409\u201317. https:\/\/doi.org\/10.1016\/j.prosdent.2004.08.001 PMID:15523328","DOI":"10.1016\/j.prosdent.2004.08.001"},{"key":"5","doi-asserted-by":"crossref","unstructured":"[5] Applegate OC. The rationale of partial denture choice. J Prosthet Dent. 1960;10:891\u2013907. https:\/\/doi.org\/10.1016\/0022-3913(60)90123-2","DOI":"10.1016\/0022-3913(60)90123-2"},{"key":"6","doi-asserted-by":"crossref","unstructured":"[6] Osada H,Shimpo H,Hayakawa T,Ohkubo C. Influence of thickness and undercut of thermoplastic resin clasps on retentive force. Dent Mater J. 2013;32:381\u20139. https:\/\/doi.org\/10.4012\/dmj.2012-284 PMID:23718997","DOI":"10.4012\/dmj.2012-284"},{"key":"7","doi-asserted-by":"crossref","unstructured":"[7] Yamazaki T,Murakami N,Suzuki S,Handa K,Yatabe M,Takahashi H,<i>et al.<\/i> Influence of block-out on retentive force of thermoplastic resin clasps: an in vitro experimental and finite element analysis. J Prosthodont Res. 2019;63:303\u20138. https:\/\/doi.org\/10.1016\/j.jpor.2019.01.002 PMID:30704930","DOI":"10.1016\/j.jpor.2019.01.002"},{"key":"8","doi-asserted-by":"crossref","unstructured":"[8] Turner JW,Radford DR,Sherriff M. Flexural properties and surface finishing of acetal resin denture clasps. J Prosthodont. 1999;8:188\u201395. https:\/\/doi.org\/10.1111\/j.1532-849X.1999.tb00034.x PMID:10740501","DOI":"10.1111\/j.1532-849X.1999.tb00034.x"},{"key":"9","doi-asserted-by":"crossref","unstructured":"[9] Sato Y,Abe Y,Yuasa Y,Akagawa Y. Effect of friction coefficient on Akers clasp retention. J Prosthet Dent. 1997;78:22\u20137. https:\/\/doi.org\/10.1016\/S0022-3913(97)70083-0 PMID:9237142","DOI":"10.1016\/S0022-3913(97)70083-0"},{"key":"10","doi-asserted-by":"crossref","unstructured":"[10] Tanaka A,Miyake N,Hotta H,Takemoto S,Yoshinari M,Yamashita S. Change in the retentive force of Akers clasp for zirconia crown by repetitive insertion and removal test. J Prosthodont Res. 2019;63:447\u201352. https:\/\/doi.org\/10.1016\/j.jpor.2019.02.005 PMID:30904359","DOI":"10.1016\/j.jpor.2019.02.005"},{"key":"11","doi-asserted-by":"crossref","unstructured":"[11] Cheng H,Xu M,Zhang H,Wu W,Zheng M,Li X. Cyclic fatigue properties of cobalt-chromium alloy clasps for partial removable dental prostheses. J Prosthet Dent. 2010;104:389\u201396. https:\/\/doi.org\/10.1016\/S0022-3913(10)60173-4 PMID:21095402","DOI":"10.1016\/S0022-3913(10)60173-4"},{"key":"12","doi-asserted-by":"crossref","unstructured":"[12] Marie A,Keeling A,Hyde TP,Nattress BR,Pavitt S,Murphy RJ,<i>et al.<\/i> Deformation and retentive force following in vitro cyclic fatigue of cobalt-chrome and aryl ketone polymer (AKP) clasps. Dent Mater. 2019;35:e113\u201321. https:\/\/doi.org\/10.1016\/j.dental.2019.02.028 PMID:30948229","DOI":"10.1016\/j.dental.2019.02.028"},{"key":"13","doi-asserted-by":"crossref","unstructured":"[13] Tribst JPM,Dal Piva AMO,Borges ALS,Ara\u00fajo RM,da Silva JMF,Bottino MA,<i>et al.<\/i> Effect of different materials and undercut on the removal force and stress distribution in circumferential clasps during direct retainer action in removable partial dentures. Dent Mater. 2020;36:179\u201386. https:\/\/doi.org\/10.1016\/j.dental.2019.11.022 PMID:31791736","DOI":"10.1016\/j.dental.2019.11.022"},{"key":"14","doi-asserted-by":"crossref","unstructured":"[14] Tannous F,Steiner M,Shahin R,Kern M. Retentive forces and fatigue resistance of thermoplastic resin clasps. Dent Mater. 2012;28:273\u20138. https:\/\/doi.org\/10.1016\/j.dental.2011.10.016 PMID:22130464","DOI":"10.1016\/j.dental.2011.10.016"},{"key":"15","doi-asserted-by":"crossref","unstructured":"[15] Torii M,Nakata T,Takahashi K,Kawamura N,Shimpo H,Ohkubo C. Fitness and retentive force of cobalt-chromium alloy clasps fabricated with repeated laser sintering and milling. J Prosthodont Res. 2018;62:342\u20136. https:\/\/doi.org\/10.1016\/j.jpor.2018.01.001 PMID:29428170","DOI":"10.1016\/j.jpor.2018.01.001"},{"key":"16","doi-asserted-by":"crossref","unstructured":"[16] Fueki K,Yoshida-Kohno E,Inamochi Y,Wakabayashi N. Patient satisfaction and preference with thermoplastic resin removable partial dentures: a randomised cross-over trial. J Prosthodont Res. 2020;64:20\u20135. https:\/\/doi.org\/10.1016\/j.jpor.2019.05.003 PMID:31196765","DOI":"10.1016\/j.jpor.2019.05.003"},{"key":"17","doi-asserted-by":"crossref","unstructured":"[17] Jovanovi\u0107 M,\u017divi\u0107 M,Milosavljevi\u0107 M. A potential application of materials based on a polymer and CAD\/CAM composite resins in prosthetic dentistry. J Prosthodont Res. 2021;65:137\u201347. https:\/\/doi.org\/10.2186\/jpr.JPOR_2019_404 PMID:32981910","DOI":"10.2186\/jpr.JPOR_2019_404"},{"key":"18","doi-asserted-by":"crossref","unstructured":"[18] Chen T,Jinno Y,Atsuta I,Tsuchiya A,Stocchero M,Bressan E,<i>et al.<\/i> Current surface modification strategies to improve the binding efficiency of emerging biomaterial polyetheretherketone (PEEK) with bone and soft tissue: A literature review. J Prosthodont Res. 2022;67:337\u201347. https:\/\/doi.org\/10.2186\/jpr.JPR_D_22_00138 PMID:36372438","DOI":"10.2186\/jpr.JPR_D_22_00138"},{"key":"19","doi-asserted-by":"crossref","unstructured":"[19] Wang J,Wu P,Liu H,Zhang L,Liu L,Ma C,<i>et al.<\/i> Polyetheretherketone versus titanium CAD-CAM framework for implant-supported fixed complete dentures: a retrospective study with up to 5-year follow-up. J Prosthodont Res. 2022;66:279\u201387. https:\/\/doi.org\/10.2186\/jpr.JPR_D_20_00142 PMID:34588401","DOI":"10.2186\/jpr.JPR_D_20_00142"},{"key":"20","doi-asserted-by":"crossref","unstructured":"[20] Lyu H,Murakami N,Yamazaki T,Wada J,Utsumi M,Wakabayashi N. Evaluation of PEEK and zirconia occlusal rest designs for removable partial dentures based on finite element analysis. J Prosthodont Res. 2023;67:196\u2013205. https:\/\/doi.org\/10.2186\/jpr.JPR_D_22_00011 PMID:35644568","DOI":"10.2186\/jpr.JPR_D_22_00011"},{"key":"21","doi-asserted-by":"crossref","unstructured":"[21] Eggbeer D,Bibb R,Williams R. The computer-aided design and rapid prototyping fabrication of removable partial denture frameworks. Proceedings of the Institution of Mechanical Engineers, Part H: J of Eng Med 2005;219:195-202. https:\/\/doi.org\/10.1243\/095441105X9372","DOI":"10.1243\/095441105X9372"},{"key":"22","unstructured":"[22] Williams R,Bibb R,Eggbeer D. CAD\/CAM in the fabrication of removable partial denture frameworks: a virtual method of surveying 3D scanned dental casts. Quintessence J Dent Technol. 2004;2:268\u201376."},{"key":"23","doi-asserted-by":"crossref","unstructured":"[23] Harb IE,Abdel-Khalek EA,Hegazy SA. CAD\/CAM constructed poly (etheretherketone)(PEEK) framework of Kennedy class I removable partial denture: A clinical report. J Prosthodont. 2019;28:e595\u20138. https:\/\/doi.org\/10.1111\/jopr.12968 PMID:30345575","DOI":"10.1111\/jopr.12968"},{"key":"24","doi-asserted-by":"crossref","unstructured":"[24] Gentz FI,Brooks DI,Liacouras PC,Petrich A,Hamlin CM,Ellert DO,<i>et al.<\/i> Retentive forces of removable partial denture clasp assemblies made from polyaryletherketone and cobalt\u2010chromium: a comparative study. J Prosthodont. 2022;31:299\u2013304. https:\/\/doi.org\/10.1111\/jopr.13398 PMID:34081360","DOI":"10.1111\/jopr.13398"},{"key":"25","doi-asserted-by":"crossref","unstructured":"[25] Tasaka A,Uekubo Y,Mitsui T,Kasahara T,Takanashi T,Homma S,<i>et al.<\/i> Applying intraoral scanner to residual ridge in edentulous regions: in vitro evaluation of inter-operator validity to confirm trueness. BMC Oral Health. 2019;19:264. https:\/\/doi.org\/10.1186\/s12903-019-0918-y PMID:31791324","DOI":"10.1186\/s12903-019-0918-y"},{"key":"26","unstructured":"[26] Cendres+M\u00e9taux. Instructions for Use Pekkton\u00ae ivory Milling blank.; 2022. Available from: www.cmsa.ch."},{"key":"27","doi-asserted-by":"crossref","unstructured":"[27] M\u00fcller S,Eickholz P,Reitmeir P,Eger T. Long\u2010term tooth loss in periodontally compromised but treated patients according to the type of prosthodontic treatment. A retrospective study. J Oral Rehabil. 2013;40:358\u201367. https:\/\/doi.org\/10.1111\/joor.12035 PMID:23362962","DOI":"10.1111\/joor.12035"},{"key":"28","doi-asserted-by":"crossref","unstructured":"[28] Fitton JS,Davies EH,Howlett JA,Pearson GJ. The physical properties of a polyacetal denture resin. Clin Mater. 1994;17:125\u20139. https:\/\/doi.org\/10.1016\/0267-6605(94)90135-X PMID:10150599","DOI":"10.1016\/0267-6605(94)90135-X"},{"key":"29","doi-asserted-by":"crossref","unstructured":"[29] Peng TY,Ogawa Y,Akebono H,Iwaguro S,Sugeta A,Shimoe S. Finite-element analysis and optimization of the mechanical properties of polyetheretherketone (PEEK) clasps for removable partial dentures. J Prosthodont Res. 2020;64:250\u20136. https:\/\/doi.org\/10.1016\/j.jpor.2019.07.012 PMID:31455560","DOI":"10.1016\/j.jpor.2019.07.012"}],"container-title":["Journal of Prosthodontic Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jpr\/68\/3\/68_JPR_D_23_00080\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,13]],"date-time":"2024-07-13T05:06:25Z","timestamp":1720847185000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jpr\/68\/3\/68_JPR_D_23_00080\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"references-count":29,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.2186\/jpr.jpr_d_23_00080","relation":{},"ISSN":["1883-1958","1883-9207"],"issn-type":[{"value":"1883-1958","type":"print"},{"value":"1883-9207","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024]]},"article-number":"JPR_D_23_00080"}}