{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T10:31:40Z","timestamp":1781605900496,"version":"3.54.5"},"reference-count":33,"publisher":"Japan Prosthodontic Society","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Prosthodont Res"],"published-print":{"date-parts":[[2026]]},"DOI":"10.2186\/jpr.jpr_d_24_00224","type":"journal-article","created":{"date-parts":[[2025,3,31]],"date-time":"2025-03-31T18:16:28Z","timestamp":1743444988000},"page":"37-42","source":"Crossref","is-referenced-by-count":5,"title":["Influence of material and tightening torque on the subsidence of implant scan          bodies"],"prefix":"10.2186","volume":"70","author":[{"given":"Daiki","family":"Morita","sequence":"first","affiliation":[{"name":"Section of Fixed Prosthodontics, Division of Oral Rehabilitation, Faculty              of Dental Science, Kyushu University, Fukuoka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tatsuya","family":"Matsuzaki","sequence":"additional","affiliation":[{"name":"Section of Fixed Prosthodontics, Division of Oral Rehabilitation, Faculty              of Dental Science, Kyushu University, Fukuoka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nobuo","family":"Sakai","sequence":"additional","affiliation":[{"name":"Mechanical and Control Engineering, Kyushu Institute of Technology,              Kitakyushu, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoichiro","family":"Ogino","sequence":"additional","affiliation":[{"name":"Section of Fixed Prosthodontics, Division of Oral Rehabilitation, Faculty              of Dental Science, Kyushu University, Fukuoka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ikiru","family":"Atsuta","sequence":"additional","affiliation":[{"name":"Section of Fixed Prosthodontics, Division of Oral Rehabilitation, Faculty              of Dental Science, Kyushu University, Fukuoka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasunori","family":"Ayukawa","sequence":"additional","affiliation":[{"name":"Section of Implant and Rehabilitative Dentistry, Division of Oral              Rehabilitation, Faculty of Dental Science, Kyushu University, Fukuoka,              Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"996","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"[1]  Gehrke SA, Shibli JA, Aramburu JS Junior, de Val          JE, Calvo-Girardo JL, Dedavid BA. Effects of different torque levels on the          implant-abutment interface in a conical internal connection. Braz Oral Res. 2016;30.          https:\/\/doi.org\/10.1590\/1807-3107BOR-2016.vol30.0040","DOI":"10.1590\/1807-3107BOR-2016.vol30.0040"},{"key":"2","doi-asserted-by":"crossref","unstructured":"[2]  Hon\u00f3rio Tonin BS,He Y,Ye N,Chew HP,Fok A.          Effects of tightening torque on screw stress and formation of implant-abutment microgaps:          A finite element analysis. J Prosthet Dent. 2022;127:882\u20139.          https:\/\/doi.org\/10.1016\/j.prosdent.2020.11.026 PMID:33472752","DOI":"10.1016\/j.prosdent.2020.11.026"},{"key":"3","doi-asserted-by":"crossref","unstructured":"[3]  Tsuruta K,Ayukawa Y,Matsuzaki T,Kihara M,Koyano          K. The influence of implant\u2013abutment connection on the screw loosening and microleakage.          Int J Implant Dent. 2018;4:11. https:\/\/doi.org\/10.1186\/s40729-018-0121-y          PMID:29629492","DOI":"10.1186\/s40729-018-0121-y"},{"key":"4","doi-asserted-by":"crossref","unstructured":"[4]  Mishra SK,Chowdhary R,Kumari S. Microleakage at          the different implant abutment interface: A systematic review. J Clin Diagn Res.          2017;11:ZE10\u20135. https:\/\/doi.org\/10.7860\/JCDR\/2017\/28951.10054          PMID:28764310","DOI":"10.7860\/JCDR\/2017\/28951.10054"},{"key":"5","doi-asserted-by":"crossref","unstructured":"[5]  Caricasulo R,Malchiodi L,Ghensi P,Fantozzi          G,Cucchi A. The influence of implant\u2010abutment connection to peri\u2010implant bone loss: A          systematic review and meta\u2010analysis. Clin Implant Dent Relat Res. 2018;20:653\u201364.          https:\/\/doi.org\/10.1111\/cid.12620 PMID:29761902","DOI":"10.1111\/cid.12620"},{"key":"6","doi-asserted-by":"crossref","unstructured":"[6]  Cassetta M,Driver A,Brandetti G,Calasso S.          Peri-implant bone loss around platform-switched Morse taper connection implants: A          prospective 60-month follow-up study. Int J Oral Maxillofac Surg. 2016;45:1577\u201385.          https:\/\/doi.org\/10.1016\/j.ijom.2016.09.009 PMID:27692898","DOI":"10.1016\/j.ijom.2016.09.009"},{"key":"7","doi-asserted-by":"crossref","unstructured":"[7]  Lee JH,Kim DG,Park CJ,Cho LR. Axial          displacements in external and internal implant\u2010abutment connection. Clin Oral Implants          Res. 2014;25:e83\u20139. https:\/\/doi.org\/10.1111\/clr.12062 PMID:23088616","DOI":"10.1111\/clr.12062"},{"key":"8","doi-asserted-by":"crossref","unstructured":"[8]  Sasada Y,Cochran D. Implant-abutment          connections: A review of biologic consequences and peri-implantitis implications. Int J          Oral Maxillofac Implants. 2017;32:1296\u2013307. https:\/\/doi.org\/10.11607\/jomi.5732          PMID:29140374","DOI":"10.11607\/jomi.5732"},{"key":"9","doi-asserted-by":"crossref","unstructured":"[9]  Janda M,Larsson C,Mattheos N. Influence of          misfit on the occurrence of porcelain veneer fractures in implant-supported metal-ceramic          fixed dental prostheses. Part 2: A three-dimensional finite element analysis. Int J          Prosthodont. 2021;34:458\u201362. https:\/\/doi.org\/10.11607\/ijp.6496          PMID:32588996","DOI":"10.11607\/ijp.6496"},{"key":"10","doi-asserted-by":"crossref","unstructured":"[10]  Kihara H,Hatakeyama W,Kondo H,Yamamori T,Baba K.          Current complications and issues of implant superstructure. J Oral Sci. 2022;64:257\u201362.          https:\/\/doi.org\/10.2334\/josnusd.21-0534 PMID:35989295","DOI":"10.2334\/josnusd.21-0534"},{"key":"11","doi-asserted-by":"crossref","unstructured":"[11]  Kihara H,Hatakeyama W,Komine F,Takafuji          K,Takahashi T,Yokota J,<i>et al.<\/i> Accuracy and practicality of intraoral          scanner in dentistry: A literature review. J Prosthodont Res. 2020;64:109\u201313.          https:\/\/doi.org\/10.1016\/j.jpor.2019.07.010 PMID:31474576","DOI":"10.1016\/j.jpor.2019.07.010"},{"key":"12","doi-asserted-by":"crossref","unstructured":"[12]  Aswani K,Wankhade S,Khalikar A,Deogade S.          Accuracy of an intraoral digital impression: A review. J Indian Prosthodont Soc.          2020;20:27\u201337. https:\/\/doi.org\/10.4103\/jips.jips_327_19 PMID:32089596","DOI":"10.4103\/jips.jips_327_19"},{"key":"13","doi-asserted-by":"crossref","unstructured":"[13]  Alikhasi M,Alsharbaty MHM,Moharrami M. Digital          implant impression technique accuracy: A systematic review. Implant Dent. 2017;26:929\u201335.          https:\/\/doi.org\/10.1097\/ID.0000000000000683 PMID:29095786","DOI":"10.1097\/ID.0000000000000683"},{"key":"14","doi-asserted-by":"crossref","unstructured":"[14]  Thanasrisuebwong P,Kulchotirat T,Anunmana C.          Effects of inter-implant distance on the accuracy of intraoral scanner: An in vitro study.          J Adv Prosthodont. 2021;13:107\u201316. https:\/\/doi.org\/10.4047\/jap.2021.13.2.107          PMID:34025959","DOI":"10.4047\/jap.2021.13.2.107"},{"key":"15","doi-asserted-by":"crossref","unstructured":"[15]  Daly S,Seong J,Parkinson C,Newcombe R,Claydon          N,West N. A proof of concept study to confirm the suitability of an intra oral scanner to          record oral images for the non-invasive assessment of gingival inflammation. J Dent.          2021;105:103579. https:\/\/doi.org\/10.1016\/j.jdent.2020.103579          PMID:33417977","DOI":"10.1016\/j.jdent.2020.103579"},{"key":"16","doi-asserted-by":"crossref","unstructured":"[16]  Daly S,Seong J,Parkinson C,Newcombe R,Claydon          N,West N. A randomised controlled trial evaluating the impact of oral health advice on          gingival health using intra oral images combined with a gingivitis specific toothpaste. J          Dent. 2023;131:104472. https:\/\/doi.org\/10.1016\/j.jdent.2023.104472          PMID:36849066","DOI":"10.1016\/j.jdent.2023.104472"},{"key":"17","doi-asserted-by":"crossref","unstructured":"[17]  Impellizzeri A,Horodynski M,De Stefano A,Palaia          G,Polimeni A,Romeo U,<i>et al.<\/i> CBCT and intra-oral scanner: The advantages          of 3D technologies in orthodontic treatment. Int J Environ Res Public Health.          2020;17:9428. https:\/\/doi.org\/10.3390\/ijerph17249428 PMID:33339197","DOI":"10.3390\/ijerph17249428"},{"key":"18","doi-asserted-by":"crossref","unstructured":"[18]  Jaber ST,Hajeer MY,Alkhouli KW,Al-Shamak          RM,Darwich KMA,Aljabban O,<i>et al.<\/i> Evaluation of three-dimensional digital          models formulated from direct intra-oral scanning of dental arches in comparison with          extra-oral scanning of poured dental models in terms of dimensional accuracy and          reliability. Cureus. 2024;16:e54869. https:\/\/doi.org\/10.7759\/cureus.54869          PMID:38405645","DOI":"10.7759\/cureus.54869"},{"key":"19","doi-asserted-by":"crossref","unstructured":"[19]  Papaspyridakos P,Vazouras K,Chen Y,Kotina          E,Natto Z,Kang K,<i>et al.<\/i> Digital vs conventional implant impressions: A          systematic review and meta\u2010analysis. J Prosthodont. 2020;29:660\u201378.          https:\/\/doi.org\/10.1111\/jopr.13211 PMID:32613641","DOI":"10.1111\/jopr.13211"},{"key":"20","doi-asserted-by":"crossref","unstructured":"[20]  Joda T,Lenherr P,Dedem P,Kovaltschuk I,Bragger          U,Zitzmann NU. Time efficiency, difficulty, and operator\u2019s preference comparing digital          and conventional implant impressions: A randomized controlled trial. Clin Oral Implants          Res. 2017;28:1318\u201323. https:\/\/doi.org\/10.1111\/clr.12982 PMID:27596805","DOI":"10.1111\/clr.12982"},{"key":"21","doi-asserted-by":"crossref","unstructured":"[21]  Sawase T,Kuroshima S. The current clinical          relevancy of intraoral scanners in implant dentistry. Dent Mater J. 2020;39:57\u201361.          https:\/\/doi.org\/10.4012\/dmj.2019-285 PMID:31723067","DOI":"10.4012\/dmj.2019-285"},{"key":"22","doi-asserted-by":"crossref","unstructured":"[22]  Mizumoto RM,Yilmaz B. Intraoral scan bodies in          implant dentistry: A systematic review. J Prosthet Dent. 2018;120:343\u201352.          https:\/\/doi.org\/10.1016\/j.prosdent.2017.10.029 PMID:29627211","DOI":"10.1016\/j.prosdent.2017.10.029"},{"key":"23","doi-asserted-by":"crossref","unstructured":"[23]  Fukazawa S,Odaira C,Kondo H. Investigation of          accuracy and reproducibility of abutment position by intraoral scanners. J Prosthodont          Res. 2017;61:450\u20139. https:\/\/doi.org\/10.1016\/j.jpor.2017.01.005          PMID:28216020","DOI":"10.1016\/j.jpor.2017.01.005"},{"key":"24","doi-asserted-by":"crossref","unstructured":"[24]  Kanawati A,Richards MW,Becker JJ,Monaco NE.          Measurement of clinicians\u2019 ability to hand torque dental implant components. J Oral          Implantol. 2009;35:185\u20138. https:\/\/doi.org\/10.1563\/1548-1336-35.4.185          PMID:19813423","DOI":"10.1563\/1548-1336-35.4.185"},{"key":"25","doi-asserted-by":"crossref","unstructured":"[25]  Kim J,Son K,Lee KB. Displacement of scan body          during screw tightening: A comparative in vitro study. J Adv Prosthodont. 2020;12:307\u201315.          https:\/\/doi.org\/10.4047\/jap.2020.12.5.307 PMID:33149852","DOI":"10.4047\/jap.2020.12.5.307"},{"key":"26","doi-asserted-by":"crossref","unstructured":"[26]  Chia V,Esguerra R,Teoh K,Teo J,Wong K,Tan K. In          vitro three-dimensional accuracy of digital implant impressions: The effect of implant          angulation. Int J Oral Maxillofac Implants. 2017;32:313\u201321.          https:\/\/doi.org\/10.11607\/jomi.5087 PMID:28231346","DOI":"10.11607\/jomi.5087"},{"key":"27","doi-asserted-by":"crossref","unstructured":"[27]  Donmez MB,\u00c7akmak G,Dede D\u00d6,K\u00fc\u00e7\u00fckekenci AS,Lu          WE,Schumacher FL,<i>et al.<\/i> Effect of scan powder and scanning technology on          measured deviations of complete-arch implant supported frameworks digitized with          industrial and intraoral scanners. J Dent. 2023;138:104736.          https:\/\/doi.org\/10.1016\/j.jdent.2023.104736 PMID:37802291","DOI":"10.1016\/j.jdent.2023.104736"},{"key":"28","doi-asserted-by":"crossref","unstructured":"[28]  Arcuri L,Pozzi A,Lio F,Rompen E,Zechner W,Nardi          A. Influence of implant scanbody material, position and operator on the accuracy of          digital impression for complete-arch: A randomized in vitro trial. J Prosthodont Res.          2020;64:128\u201336. https:\/\/doi.org\/10.1016\/j.jpor.2019.06.001 PMID:31255546","DOI":"10.1016\/j.jpor.2019.06.001"},{"key":"29","doi-asserted-by":"crossref","unstructured":"[29]  Mattheos N,Vergoullis I,Janda M,Miseli A. The          implant supracrestal complex and its significance for long-term successful clinical          outcomes. Int J Prosthodont. 2021;34:88\u2013100. https:\/\/doi.org\/10.11607\/ijp.7201          PMID:33570524","DOI":"10.11607\/ijp.7201"},{"key":"30","doi-asserted-by":"crossref","unstructured":"[30]Sandler J,Werner P,Shaffer MSP,Demchuk          V,Altst\u00e4dt V,Windle AH. Carbon-nanofibre-reinforced poly(ether ether ketone) composites.          Composites Part a-Applied Science and Manufacturing. 2002;33:1033-9.          https:\/\/doi.org\/https:\/\/doi.org\/10.1016\/S1359-835X(02)00084-2.","DOI":"10.1016\/S1359-835X(02)00084-2"},{"key":"31","doi-asserted-by":"crossref","unstructured":"[31]  Niinomi M. Mechanical properties of biomedical          titanium alloys. Mater Sci Eng A. 1998;243:231\u20136.          https:\/\/doi.org\/10.1016\/S0921-5093(97)00806-X","DOI":"10.1016\/S0921-5093(97)00806-X"},{"key":"32","doi-asserted-by":"crossref","unstructured":"[32]  Br\u00e5nemark PI. Osseointegration and its          experimental background. J Prosthet Dent. 1983;50:399\u2013410.          https:\/\/doi.org\/10.1016\/S0022-3913(83)80101-2 PMID:6352924","DOI":"10.1016\/S0022-3913(83)80101-2"},{"key":"33","unstructured":"[33]  Abduo J,Swain M. Influence of vertical misfit of          titanium and zirconia frameworks on peri-implant strain. Int J Oral Maxillofac Implants.          2012;27:529\u201336. PMID:22616045"}],"container-title":["Journal of Prosthodontic Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jpr\/70\/1\/70_JPR_D_24_00224\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,17]],"date-time":"2026-01-17T04:46:10Z","timestamp":1768625170000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jpr\/70\/1\/70_JPR_D_24_00224\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":33,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.2186\/jpr.jpr_d_24_00224","relation":{},"ISSN":["1883-1958","1883-9207"],"issn-type":[{"value":"1883-1958","type":"print"},{"value":"1883-9207","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026]]},"article-number":"JPR_D_24_00224"}}