{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T17:36:00Z","timestamp":1791048960607,"version":"4.1.0"},"reference-count":27,"publisher":"Japan Prosthodontic Society","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Prosthodont Res"],"published-print":{"date-parts":[[2026]]},"DOI":"10.2186\/jpr.jpr_d_25_00067","type":"journal-article","created":{"date-parts":[[2025,9,25]],"date-time":"2025-09-25T22:09:23Z","timestamp":1758838163000},"page":"306-312","source":"Crossref","is-referenced-by-count":2,"title":["Impact of intaglio surface depth and scanning technology on the trueness of          complete denture scans using intraoral scanners"],"prefix":"10.2186","volume":"70","author":[{"given":"Yuanhua","family":"Piao","sequence":"first","affiliation":[{"name":"Digital Dentistry, Graduate School of Medical and Dental Sciences,              Institute of Science Tokyo, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maiko","family":"Iwaki","sequence":"additional","affiliation":[{"name":"Digital Dentistry, Graduate School of Medical and Dental Sciences,              Institute of Science Tokyo, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yumi","family":"Tsuchida","sequence":"additional","affiliation":[{"name":"Digital Dentistry, Graduate School of Medical and Dental Sciences,              Institute of Science Tokyo, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yo","family":"Akiyama","sequence":"additional","affiliation":[{"name":"Gerodontology and Oral Rehabilitation, Graduate School of Medical and              Dental Sciences, Institute of Science Tokyo, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenming","family":"Zhou","sequence":"additional","affiliation":[{"name":"Gerodontology and Oral Rehabilitation, Graduate School of Medical and              Dental Sciences, Institute of Science Tokyo, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atsushi","family":"Takaichi","sequence":"additional","affiliation":[{"name":"Digital Dentistry, Graduate School of Medical and Dental Sciences,              Institute of Science Tokyo, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manabu","family":"Kanazawa","sequence":"additional","affiliation":[{"name":"Gerodontology and Oral Rehabilitation, Graduate School of Medical and              Dental Sciences, Institute of Science Tokyo, Tokyo, Japan"},{"name":"Clinic of General, Special Care and Geriatric Dentistry, Center for Dental              Medicine, University of Zurich, Zurich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"996","reference":[{"key":"1","doi-asserted-by":"publisher","unstructured":"[1]  Wismeijer D,Mans R,van Genuchten M,Reijers HA.          Patients\u2019 preferences when comparing analogue implant impressions using a polyether          impression material versus digital impressions (Intraoral Scan) of dental implants. Clin          Oral Implants Res. 2014;25:1113\u20138. https:\/\/doi.org\/10.1111\/clr.12234          PMID:23941118","DOI":"10.1111\/clr.12234"},{"key":"2","doi-asserted-by":"publisher","unstructured":"[2]  Burzynski JA,Firestone AR,Beck FM,Fields HW          Jr,Deguchi T. Comparison of digital intraoral scanners and alginate impressions: time and          patient satisfaction. Am J Orthod Dentofacial Orthop. 2018;153:534\u201341.          https:\/\/doi.org\/10.1016\/j.ajodo.2017.08.017 PMID:29602345","DOI":"10.1016\/j.ajodo.2017.08.017"},{"key":"3","doi-asserted-by":"publisher","unstructured":"[3]  Oyamada Y,Yonezawa Y,Kondo H. Simple duplication          technique of complete denture using an intraoral scanner. J Prosthodont. 2021;30:458\u201361.          https:\/\/doi.org\/10.1111\/jopr.13342 PMID:33533111","DOI":"10.1111\/jopr.13342"},{"key":"4","doi-asserted-by":"publisher","unstructured":"[4]  Chen L,Li D,Zhou J,Lin WS,Tan J. Duplicating          complete dentures with conventional and digital methods: comparisons of trueness and          efficiency. Dent J. 2022;10:35. https:\/\/doi.org\/10.3390\/dj10030035          PMID:35323238","DOI":"10.3390\/dj10030035"},{"key":"5","doi-asserted-by":"publisher","unstructured":"[5]  Arai K,Tanaka Y,Matsuda S,Okamura T,Iwayama          K,Ono Y. Complete denture fabrication using digitally fabricated copy dentures for a          patient with moderate dementia. Case Rep Dent. 2021;2021:1\u20137.          https:\/\/doi.org\/10.1155\/2021\/9385095 PMID:34354844","DOI":"10.1155\/2021\/9385095"},{"key":"6","doi-asserted-by":"publisher","unstructured":"[6]  Tanaka J,Murakami T,Tanaka S,Kanno T,Imada Y.          Accuracy of implant-supported copy overdentures fabricated using either an intraoral          scanner and a 3D printer or the conventional copy denture technique: A comparative study.          Int J Oral Maxillofac Implants. 2022;37:989\u201396. https:\/\/doi.org\/10.11607\/jomi.9575          PMID:36170314","DOI":"10.11607\/jomi.9575"},{"key":"7","unstructured":"[7]  Davda K,Osnes C,Dillon S,Wu J,Hyde P,Keeling A.          An investigation into the trueness and precision of copy denture templates produced by          rapid prototyping and conventional means. Eur J Prosthodont Restor Dent. 2017;25:186\u201392.          https:\/\/doi.org\/10.1922\/EJPRD_01716Davda07 PMID:29182214"},{"key":"8","doi-asserted-by":"publisher","unstructured":"[8]  Kurahashi K,Matsuda T,Goto T,Ishida Y,Ito          T,Ichikawa T. Duplication of complete dentures using general-purpose handheld optical          scanner and 3-dimensional printer: Introduction and clinical considerations. J Prosthodont          Res. 2017;61:81\u20136. https:\/\/doi.org\/10.1016\/j.jpor.2016.06.002          PMID:27345254","DOI":"10.1016\/j.jpor.2016.06.002"},{"key":"9","doi-asserted-by":"publisher","unstructured":"[9]  Cho SM,Oh KC,Park JM,Lim JH,Kwon JS. Comparative          assessment of marginal and internal gaps of cast-free monolithic zirconia crowns          fabricated from 2 intraoral scanners: A prospective, double-blind, randomized clinical          trial. J Prosthet Dent. 2023;129:69\u201375. https:\/\/doi.org\/10.1016\/j.prosdent.2022.05.035          PMID:35985854","DOI":"10.1016\/j.prosdent.2022.05.035"},{"key":"10","doi-asserted-by":"publisher","unstructured":"[10]  Osman RB,Alharbi NM. Influence of scan          technology on the accuracy and speed of intraoral scanning systems for the edentulous          maxilla: An in vitro study. J Prosthodont. 2023;32:821\u20138.          https:\/\/doi.org\/10.1111\/jopr.13633 PMID:36571837","DOI":"10.1111\/jopr.13633"},{"key":"11","doi-asserted-by":"publisher","unstructured":"[11]  Kim MK,Son K,Yu BY,Lee KB. Effect of the          volumetric dimensions of a complete arch on the accuracy of scanners. J Adv Prosthodont.          2020;12:361\u20138. https:\/\/doi.org\/10.4047\/jap.2020.12.6.361 PMID:33489020","DOI":"10.4047\/jap.2020.12.6.361"},{"key":"12","doi-asserted-by":"publisher","unstructured":"[12]  Elbashti M,Hattori M,Patzelt S,Aswehlee A,Sumita          Y,Taniguchi H. Precision and trueness of computerized optical impressions in maxillectomy          defects: an in vitro 3D comparison. Int J Prosthodont. 2019;32:289\u201392.          https:\/\/doi.org\/10.11607\/ijp.6077 PMID:31034547","DOI":"10.11607\/ijp.6077"},{"key":"13","doi-asserted-by":"publisher","unstructured":"[13]  Jeong ID,Lee JJ,Jeon JH,Kim JH,Kim HY,Kim WC.          Accuracy of complete-arch model using an intraoral video scanner: an in vitro study. J          Prosthet Dent. 2016;115:755\u20139. https:\/\/doi.org\/10.1016\/j.prosdent.2015.11.007          PMID:26794703","DOI":"10.1016\/j.prosdent.2015.11.007"},{"key":"14","doi-asserted-by":"publisher","unstructured":"[14]  G\u00f3mez-Polo M,Cimolai A,Ortega R,Barmak AB,Kois          JC,Revilla-Le\u00f3n M. Accuracy, scanning time, and number of photograms of various scanning          patterns for the extraoral digitalization of complete dentures by using an intraoral          scanner. J Prosthet Dent. 2024;131:521\u20138. https:\/\/doi.org\/10.1016\/j.prosdent.2022.03.017          PMID:35527066","DOI":"10.1016\/j.prosdent.2022.03.017"},{"key":"15","unstructured":"[15]  International Organization for Standardization.          Accuracy (trueness and precision) of measurement methods and results e Part 1: General          principles and definitions (ISO 5725e1:1994). Berlin: Beuth Verlag GmbH;          1997."},{"key":"16","doi-asserted-by":"publisher","unstructured":"[16]  Ender A,Mehl A. Accuracy of complete-arch dental          impressions: A new method of measuring trueness and precision. J Prosthet Dent.          2013;109:121\u20138. https:\/\/doi.org\/10.1016\/S0022-3913(13)60028-1          PMID:23395338","DOI":"10.1016\/S0022-3913(13)60028-1"},{"key":"17","unstructured":"[17]  Japan Prosthodontic Society. Protocol for          assessing the difficulty level of prosthodontic treatment,          https:\/\/www.hotetsu.com\/files\/files_719.pdf; 2022 [accessed 2 June 2025]."},{"key":"18","doi-asserted-by":"publisher","unstructured":"[18]  Soeda Y,Kanazawa M,Arakida T,Iwaki M,Minakuchi          S. CAD-CAM milled complete dentures with custom disks and prefabricated artificial teeth:          A dental technique. J Prosthet Dent. 2022;127:55\u20138.          https:\/\/doi.org\/10.1016\/j.prosdent.2020.06.020 PMID:33190864","DOI":"10.1016\/j.prosdent.2020.06.020"},{"key":"19","doi-asserted-by":"publisher","unstructured":"[19]  Rhee YK,Huh YH,Cho LR,Park CJ. Comparison of          intraoral scanning and conventional impression techniques using 3-dimensional          superimposition. J Adv Prosthodont. 2015;7:460\u20137. https:\/\/doi.org\/10.4047\/jap.2015.7.6.460          PMID:26816576","DOI":"10.4047\/jap.2015.7.6.460"},{"key":"20","doi-asserted-by":"publisher","unstructured":"[20]  Amornvit P,Rokaya D,Sanohkan S. Comparison of          accuracy of current ten intraoral scanners. BioMed Res Int. 2021;2021:2673040.          https:\/\/doi.org\/10.1155\/2021\/2673040 PMID:34552983","DOI":"10.1155\/2021\/2673040"},{"key":"21","doi-asserted-by":"publisher","unstructured":"[21]  Oh KC,Park JM,Moon HS. Effects of scanning          strategy and scanner type on the accuracy of intraoral scans: A new approach for assessing          the accuracy of scanned data. J Prosthodont. 2020;29:518\u201323.          https:\/\/doi.org\/10.1111\/jopr.13158 PMID:32133690","DOI":"10.1111\/jopr.13158"},{"key":"22","doi-asserted-by":"publisher","unstructured":"[22]  Le Texier L,Nicolas E,Batisse C. Evaluation and          comparison of the accuracy of three intraoral scanners for replicating a complete denture.          J Prosthet Dent. 2024;131:706.e1\u20138. https:\/\/doi.org\/10.1016\/j.prosdent.2024.01.011          PMID:38310062","DOI":"10.1016\/j.prosdent.2024.01.011"},{"key":"23","doi-asserted-by":"publisher","unstructured":"[23]  Alehaideb A,Lin WS,Levon JA,Chu TMG,Yang CC.          Accuracy of digital duplication scanning methods for complete dentures. J Prosthodont.          2025;34:42\u20138. https:\/\/doi.org\/10.1111\/jopr.13788 PMID:37924229","DOI":"10.1111\/jopr.13788"},{"key":"24","doi-asserted-by":"publisher","unstructured":"[24]  Logozzo S,Zanetti EM,Franceschini G,Kilpel\u00e4          A,M\u00e4kynen A. Recent advances in dental optics \u2013 Part I: 3D intraoral scanners for          restorative dentistry. Opt Lasers Eng. 2014;54:203\u201321.          https:\/\/doi.org\/10.1016\/j.optlaseng.2013.07.017","DOI":"10.1016\/j.optlaseng.2013.07.017"},{"key":"25","doi-asserted-by":"publisher","unstructured":"[25]  Waldecker M,Rues S,Rammelsberg P,B\u00f6micke W.          Accuracy of complete-arch intraoral scans based on confocal microscopy versus optical          triangulation: A comparative in vitro study. J Prosthet Dent. 2021;126:414\u201320.          https:\/\/doi.org\/10.1016\/j.prosdent.2020.04.019 PMID:32950254","DOI":"10.1016\/j.prosdent.2020.04.019"},{"key":"26","doi-asserted-by":"publisher","unstructured":"[26]  Sawangsri K,Leelaluk S,Hsieh Y,Lee DJ.          Comparison of trueness, time, and number of images among different denture digitization          protocols. J Prosthodont. 2025;34:388\u201394. https:\/\/doi.org\/10.1111\/jopr.13967          PMID:39471255","DOI":"10.1111\/jopr.13967"},{"key":"27","doi-asserted-by":"publisher","unstructured":"[27]  Osnes CA,Wu JH,Venezia P,Ferrari M,Keeling AJ.          Full arch precision of six intraoral scanners in vitro. J Prosthodont Res. 2020;64:6\u201311.          https:\/\/doi.org\/10.1016\/j.jpor.2019.05.005 PMID:31227447","DOI":"10.1016\/j.jpor.2019.05.005"}],"container-title":["Journal of Prosthodontic Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jpr\/70\/2\/70_JPR_D_25_00067\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,18]],"date-time":"2026-04-18T04:24:15Z","timestamp":1776486255000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jpr\/70\/2\/70_JPR_D_25_00067\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":27,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.2186\/jpr.jpr_d_25_00067","relation":{},"ISSN":["1883-1958","1883-9207"],"issn-type":[{"value":"1883-1958","type":"print"},{"value":"1883-9207","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026]]},"article-number":"JPR_D_25_00067"}}