{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,24]],"date-time":"2026-01-24T19:15:59Z","timestamp":1769282159040,"version":"3.49.0"},"reference-count":35,"publisher":"Japan Prosthodontic Society","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Prosthodont Res"],"published-print":{"date-parts":[[2026]]},"DOI":"10.2186\/jpr.jpr_d_25_00094","type":"journal-article","created":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T22:08:52Z","timestamp":1769119732000},"source":"Crossref","is-referenced-by-count":0,"title":["Telescopic prosthesis for extensive mandibular tooth loss with a polyetherketoneketone framework fabricated using digital workflow: A case report"],"prefix":"10.2186","author":[{"given":"Rong","family":"Huang","sequence":"first","affiliation":[{"name":"Department of Prosthodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology,Nanjing University, Nanjing, PR China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wen","family":"Shu","sequence":"additional","affiliation":[{"name":"Department of Dental laboratory, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology,Nanjing University, Nanjing, PR China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaojing","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Dental laboratory, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology,Nanjing University, Nanjing, PR China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yalin","family":"Guo","sequence":"additional","affiliation":[{"name":"Department of Dental laboratory, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology,Nanjing University, Nanjing, PR China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fangfang","family":"Sun","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology,Nanjing University, Nanjing, PR China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guofeng","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology,Nanjing University, Nanjing, PR China"},{"name":"Department of Digital Engineering Center of Stomatology, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology,Nanjing University, Nanjing, PR China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"996","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"[1]Roach M. Base metal alloys used for dental restorations and implants. Dent Clin North Am. 2007;51:603\u201327, vi. https:\/\/doi.org\/10.1016\/j.cden.2007.04.001","DOI":"10.1016\/j.cden.2007.04.001"},{"key":"2","doi-asserted-by":"crossref","unstructured":"[2] Hong JK,Kim SK,Heo SJ,Koak JY. Mechanical properties and metal-ceramic bond strength of Co-Cr alloy manufactured by selective laser melting. Materials (Basel). 2020;13:5745. https:\/\/doi.org\/10.3390\/ma13245745 PMID:33339320","DOI":"10.3390\/ma13245745"},{"key":"3","doi-asserted-by":"crossref","unstructured":"[3] Levartovsky S,Arieli A,Fridenberg N,Matalon S,Pilo R. Survival and success rates of soft-milled cobalt-chromium-ceramic full-arch screw-retained implant-supported prostheses: a 2- to 7-year follow-up retrospective study. Clin Oral Investig. 2021;25:5341\u201350. https:\/\/doi.org\/10.1007\/s00784-021-03842-7 PMID:33616806","DOI":"10.1007\/s00784-021-03842-7"},{"key":"4","doi-asserted-by":"crossref","unstructured":"[4] Wiesli MG,\u00d6zcan M. High-performance polymers and their potential application as medical and oral implant materials: A review. Implant Dent. 2015;448\u201357. https:\/\/doi.org\/10.1097\/ID.0000000000000285 PMID:26035377","DOI":"10.1097\/ID.0000000000000285"},{"key":"5","doi-asserted-by":"crossref","unstructured":"[5] Al-Imam H,Benetti AR,\u00d6zhayat EB,Pedersen AML,Johansen JD,Thyssen JP,<i>et al.<\/i> Cobalt release and complications resulting from the use of dental prostheses. Contact Dermatitis. 2016;75:377\u201383. https:\/\/doi.org\/10.1111\/cod.12649 PMID:27385620","DOI":"10.1111\/cod.12649"},{"key":"6","doi-asserted-by":"crossref","unstructured":"[6] Micovic D,Mayinger F,Bauer S,Roos M,Eichberger M,Stawarczyk B. Is the high-performance thermoplastic polyetheretherketone indicated as a clasp material for removable dental prostheses? Clin Oral Investig. 2021;25:2859\u201366. https:\/\/doi.org\/10.1007\/s00784-020-03603-y PMID:33026523","DOI":"10.1007\/s00784-020-03603-y"},{"key":"7","doi-asserted-by":"crossref","unstructured":"[7] Lucchetti MC,Fratto G,Valeriani F,De Vittori E,Giampaoli S,Papetti P,<i>et al.<\/i> Cobalt-chromium alloys in dentistry: An evaluation of metal ion release. J Prosthet Dent. 2015;114:602\u20138. https:\/\/doi.org\/10.1016\/j.prosdent.2015.03.002 PMID:25979449","DOI":"10.1016\/j.prosdent.2015.03.002"},{"key":"8","doi-asserted-by":"crossref","unstructured":"[8] Zol SM,Alauddin MS,Said Z,Mohd Ghazali MI,Hao-Ern L,Mohd Farid DA,<i>et al.<\/i> Description of poly(aryl-ether-ketone) materials (PAEKs), polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) for application as a dental material: A materials science review. Polymers (Basel). 2023;15:2170. https:\/\/doi.org\/10.3390\/polym15092170 PMID:37177316","DOI":"10.3390\/polym15092170"},{"key":"9","doi-asserted-by":"crossref","unstructured":"[9] Alqurashi H,Khurshid Z,Syed AUY,Rashid Habib S,Rokaya D,Zafar MS. Polyetherketoneketone (PEKK): An emerging biomaterial for oral implants and dental prostheses. J Adv Res. 2021;28:87\u201395. https:\/\/doi.org\/10.1016\/j.jare.2020.09.004 PMID:33384878","DOI":"10.1016\/j.jare.2020.09.004"},{"key":"10","doi-asserted-by":"crossref","unstructured":"[10] Lommen J,Schorn L,Sproll C,Haussmann J,K\u00fcbler NR,Budach W,<i>et al.<\/i> Reduction of CT artifacts using polyetheretherketone (PEEK), polyetherketoneketone (PEKK), polyphenylsulfone (PPSU), and polyethylene (PE) reconstruction plates in oral oncology. J Oral Maxillofac Surg. 2022;80:1272\u201383. https:\/\/doi.org\/10.1016\/j.joms.2022.03.004 PMID:35378095","DOI":"10.1016\/j.joms.2022.03.004"},{"key":"11","doi-asserted-by":"crossref","unstructured":"[11] Song CH,Choi JW,Jeon YC,Jeong CM,Lee SH,Kang ES,<i>et al.<\/i> Comparison of the microtensile bond strength of a polyetherketoneketone (PEKK) tooth post cemented with various surface treatments and various resin cements. Materials (Basel). 2018;11:916. https:\/\/doi.org\/10.3390\/ma11060916 PMID:29844270","DOI":"10.3390\/ma11060916"},{"key":"12","doi-asserted-by":"crossref","unstructured":"[12] Bae SY,Park JY,Jeong ID,Kim HY,Kim JH,Kim WC. Three-dimensional analysis of marginal and internal fit of copings fabricated with polyetherketoneketone (PEKK) and zirconia. J Prosthodont Res. 2017;61:106\u201312. https:\/\/doi.org\/10.1016\/j.jpor.2016.07.005 PMID:27484816","DOI":"10.1016\/j.jpor.2016.07.005"},{"key":"13","doi-asserted-by":"crossref","unstructured":"[13] Alsadon O,Wood D,Patrick D,Pollington S. Fatigue behavior and damage modes of high performance poly-ether-ketone-ketone PEKK bilayered crowns. J Mech Behav Biomed Mater. 2020;110:103957. https:\/\/doi.org\/10.1016\/j.jmbbm.2020.103957 PMID:32957248","DOI":"10.1016\/j.jmbbm.2020.103957"},{"key":"14","doi-asserted-by":"crossref","unstructured":"[14] G\u00fcven M\u00c7,Dayan S\u00c7,Y\u0131ld\u0131r\u0131m G,Mumcu E. Custom and prefabricated PolyEtherKetoneKetone (PEKK) post\u2010core systems bond strength: Scanning electron microscopy evaluation. Microsc Res Tech. 2020;83:804\u201310. https:\/\/doi.org\/10.1002\/jemt.23471 PMID:32167226","DOI":"10.1002\/jemt.23471"},{"key":"15","doi-asserted-by":"crossref","unstructured":"[15] Ghanem N,Ali H,Bahrli N,Hassan H. Clinical performance of custom\u2010milled polyetherketoneketone (PEKK) posts and cores: A 12\u2010month follow\u2010up randomized controlled pilot study. Clin Exp Dent Res. 2024;10:e854. https:\/\/doi.org\/10.1002\/cre2.854 PMID:38433309","DOI":"10.1002\/cre2.854"},{"key":"16","doi-asserted-by":"crossref","unstructured":"[16] Dawson JH,Hyde B,Hurst M,Harris BT,Lin WS. Polyetherketoneketone (PEKK), a framework material for complete fixed and removable dental prostheses: A clinical report. J Prosthet Dent. 2018;119:867\u201372. https:\/\/doi.org\/10.1016\/j.prosdent.2017.09.008 PMID:29195815","DOI":"10.1016\/j.prosdent.2017.09.008"},{"key":"17","doi-asserted-by":"crossref","unstructured":"[17] Sun F,Shen X,Zhou N,Gao Y,Guo Y,Yang X,<i>et al.<\/i> A speech bulb prosthesis for a soft palate defect with a polyetherketoneketone (PEKK) framework fabricated by multiple digital techniques: A clinical report. J Prosthet Dent. 2020;124:495\u20139. https:\/\/doi.org\/10.1016\/j.prosdent.2019.10.020 PMID:31879082","DOI":"10.1016\/j.prosdent.2019.10.020"},{"key":"18","doi-asserted-by":"crossref","unstructured":"[18] Oh KC,Park JH,Lee J,Moon HS. Treatment of a mandibular discontinuity defect by using a fibula free flap and an implant-supported fixed complete denture fabricated with a PEKK framework: A clinical report. J Prosthet Dent. 2018;119:1021\u20134. https:\/\/doi.org\/10.1016\/j.prosdent.2017.07.024 PMID:28967393","DOI":"10.1016\/j.prosdent.2017.07.024"},{"key":"19","doi-asserted-by":"crossref","unstructured":"[19] Nakamura M,Tanaka A,Tasaka A,Yoshinari M,Takemoto S,Yamashita S. Comparison of retentive forces between telescopic crowns made of poly(ether ether ketone) and type 4 gold alloy. Dent Mater J. 2021;40:129\u201335. https:\/\/doi.org\/10.4012\/dmj.2019-298 PMID:32863374","DOI":"10.4012\/dmj.2019-298"},{"key":"20","doi-asserted-by":"crossref","unstructured":"[20] Micovic Soldatovic D,Bitter M,Meinen J,Huth KC,Liebermann A,Stawarczyk B. Impact of material combinations and removal and insertion cycles on the retention force of telescopic systems. Clin Oral Investig. 2023;27:4007\u201316. https:\/\/doi.org\/10.1007\/s00784-023-05027-w PMID:37086284","DOI":"10.1007\/s00784-023-05027-w"},{"key":"21","doi-asserted-by":"crossref","unstructured":"[21] Igarashi K,Katagiri H,Abou-Ayash S,Schimmel M,Afrashtehfar KI. Double-crown prosthesis retention using polyetherketoneketone (PEKK): An in vitro study. J Prosthodont. 2023;32:154\u201361. https:\/\/doi.org\/10.1111\/jopr.13512 PMID:35343624","DOI":"10.1111\/jopr.13512"},{"key":"22","doi-asserted-by":"crossref","unstructured":"[22] Kewekordes T,Wille S,Kern M. Wear of polyetherketoneketones \u2014 Influence of titanium dioxide content and antagonistic material. Dent Mater. 2018;34:560\u20137. https:\/\/doi.org\/10.1016\/j.dental.2017.12.009 PMID:29373134","DOI":"10.1016\/j.dental.2017.12.009"},{"key":"23","doi-asserted-by":"crossref","unstructured":"[23] Hahnel S,Scherl C,Rosentritt M. Interim rehabilitation of occlusal vertical dimension using a double-crown-retained removable dental prosthesis with polyetheretherketone framework. J Prosthet Dent. 2018;119:315\u20138. https:\/\/doi.org\/10.1016\/j.prosdent.2017.02.017 PMID:28641822","DOI":"10.1016\/j.prosdent.2017.02.017"},{"key":"24","doi-asserted-by":"crossref","unstructured":"[24] Refai OM,Nawar NH,Lebshtien IT. Assessment of retention of CAD-CAM milled PEKK vs. PEEK double crown-retained removable partial dentures: A randomized clinical trial. J Contemp Dent Pract. 2022;22:1250\u20136. https:\/\/doi.org\/10.5005\/jp-journals-10024-3233 PMID:35343449","DOI":"10.5005\/jp-journals-10024-3233"},{"key":"25","doi-asserted-by":"crossref","unstructured":"[25] Tasaka A,Rues S,Schwindling FS,Rammelsberg P,Yamashita S. Retentive force of conical crowns combining zirconia and fiber-reinforced composite. J Dent. 2022;124:104222. https:\/\/doi.org\/10.1016\/j.jdent.2022.104222 PMID:35820502","DOI":"10.1016\/j.jdent.2022.104222"},{"key":"26","doi-asserted-by":"crossref","unstructured":"[26] Tasaka A,Schwindling FS,Rues S,Rammelsberg P,Yamashita S. Retentive force of telescopic crowns combining fiber-reinforced composite and zirconia. J Prosthodont Res. 2022;66:265\u201371. https:\/\/doi.org\/10.2186\/jpr.JPR_D_20_00163 PMID:34349081","DOI":"10.2186\/jpr.JPR_D_20_00163"},{"key":"27","doi-asserted-by":"crossref","unstructured":"[27] Luft V,Pospiech P,Schurig A,Schmitter M. In vitro investigations on retention force behavior of conventional and modern double crown systems. Dent Mater. 2021;37:191\u2013200. https:\/\/doi.org\/10.1016\/j.dental.2020.10.028 PMID:33276956","DOI":"10.1016\/j.dental.2020.10.028"},{"key":"28","doi-asserted-by":"crossref","unstructured":"[28] Mochalski J,Fr\u00f6hls C,Keilig L,Bourauel C,D\u00f6rsam I. Experimental and numerical investigations of fracture and fatigue behaviour of implant-supported bars with distal extension made of three different materials. Biomedical Engineering \/ Biomedizinische Technik. 2021;66:305\u201316. https:\/\/doi.org\/10.1515\/bmt-2020-0157 PMID:34062636","DOI":"10.1515\/bmt-2020-0157"},{"key":"29","doi-asserted-by":"crossref","unstructured":"[29] Ichikawa T,Kurahashi K,Liu L,Matsuda T,Ishida Y. Use of a polyetheretherketone clasp retainer for removable partial denture: A case report. Dent J. 2019;7:4. https:\/\/doi.org\/10.3390\/dj7010004 PMID:30609778","DOI":"10.3390\/dj7010004"},{"key":"30","doi-asserted-by":"crossref","unstructured":"[30] Young FA,Williams KR,Draughn R,Strohaver R. Design of prosthetic cantilever bridgework supported by osseointegrated implants using the finite element method. Dent Mater. 1998;14:37\u201343. https:\/\/doi.org\/10.1016\/S0109-5641(98)00007-4 PMID:9972149","DOI":"10.1016\/S0109-5641(98)00007-4"},{"key":"31","doi-asserted-by":"crossref","unstructured":"[31]Tribst JP,Dal Piva AM,Syed AU,Alrabiah M,Al-Aali KA,Vohra F,Abduljabbar T. Comparative stress analysis of polyetherketoneketone (PEKK) telescopic crowns supported by different primary crown materials. Appl Sci-Basel. 2022;12:3446. https:\/\/doi.org\/10.3390\/app12073446","DOI":"10.3390\/app12073446"},{"key":"32","doi-asserted-by":"crossref","unstructured":"[32] Stock V,Wagner C,Merk S,Roos M,Schmidlin PR,Eichberger M,<i>et al.<\/i> Retention force of differently fabricated telescopic PEEK crowns with different tapers. Dent Mater J. 2016;35:594\u2013600. https:\/\/doi.org\/10.4012\/dmj.2015-249 PMID:27477224","DOI":"10.4012\/dmj.2015-249"},{"key":"33","unstructured":"[33] Fingerhut C,Schindler HJ,Schweizerhof K,Kordass B,Lenz J. Finite element analysis of the principles and loosening force of the conical telescopic crown: A computer-based study. Int J Comput Dent. 2014;17:199\u2013218. PMID:25558760"},{"key":"34","doi-asserted-by":"crossref","unstructured":"[34] Pedroso JM,Enger M,Bandeira P,Magalh\u00e3es FD. Comparative study of friction and wear performance of PEK, PEEK and PEKK binders in tribological coatings. Polymers (Basel). 2022;14:4008. https:\/\/doi.org\/10.3390\/polym14194008 PMID:36235956","DOI":"10.3390\/polym14194008"},{"key":"35","doi-asserted-by":"crossref","unstructured":"[35] Tasaka A,Shimizu T,Ito K,Wadachi J,Odaka K,Yamashita S. Digital technology for fabrication of removable dental prosthesis with double crowns combining fiber-reinforced composite and zirconia. J Prosthodont Res. 2022;67:487\u201392. https:\/\/doi.org\/10.2186\/jpr.JPR_D_22_00064 PMID:36031348","DOI":"10.2186\/jpr.JPR_D_22_00064"}],"container-title":["Journal of Prosthodontic Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jpr\/advpub\/0\/advpub_JPR_D_25_00094\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,24]],"date-time":"2026-01-24T04:45:41Z","timestamp":1769229941000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jpr\/advpub\/0\/advpub_JPR_D_25_00094\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":35,"URL":"https:\/\/doi.org\/10.2186\/jpr.jpr_d_25_00094","relation":{},"ISSN":["1883-1958","1883-9207"],"issn-type":[{"value":"1883-1958","type":"print"},{"value":"1883-9207","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026]]},"article-number":"JPR_D_25_00094"}}