{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T03:45:37Z","timestamp":1787024737138,"version":"build-2736575974"},"reference-count":40,"publisher":"Japan Prosthodontic Society","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Prosthodont Res"],"published-print":{"date-parts":[[2026]]},"DOI":"10.2186\/jpr.jpr_d_25_00308","type":"journal-article","created":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T22:14:28Z","timestamp":1776291268000},"source":"Crossref","is-referenced-by-count":1,"title":["Influence of multiple use of titanium and PEEK scan bodies on scan precision after sterilization and thermal disinfection: An &lt;i&gt;in vitro&lt;\/i&gt; study"],"prefix":"10.2186","author":[{"given":"Elisabeth","family":"V\u00f6ller","sequence":"first","affiliation":[{"name":"Department of Prosthodontics, Center for Dentistry and Oral Medicine (Carolinum), Goethe-University Frankfurt am Main, Frankfurt am Main, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan-Frederik","family":"G\u00fcth","sequence":"additional","affiliation":[{"name":"Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Heuser","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Center for Dentistry and Oral Medicine (Carolinum), Goethe-University Frankfurt am Main, Frankfurt am Main, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oliver","family":"Schubert","sequence":"additional","affiliation":[{"name":"Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Josef","family":"Schweiger","sequence":"additional","affiliation":[{"name":"Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tobias","family":"Graf","sequence":"additional","affiliation":[{"name":"Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"996","reference":[{"key":"1","doi-asserted-by":"publisher","unstructured":"[1] Bernauer SA,Zitzmann NU,Joda T. The complete digital workflow in fixed prosthodontics updated: A systematic review. Healthcare (Basel). 2023;11:679. https:\/\/doi.org\/10.3390\/healthcare11050679 PMID:36900684","DOI":"10.3390\/healthcare11050679"},{"key":"2","doi-asserted-by":"publisher","unstructured":"[2] Siqueira R,Galli M,Chen Z,Mendon\u00e7a G,Meirelles L,Wang HL,<i>et al.<\/i> Intraoral scanning reduces procedure time and improves patient comfort in fixed prosthodontics and implant dentistry: A systematic review. Clin Oral Investig. 2021;25:6517\u201331. https:\/\/doi.org\/10.1007\/s00784-021-04157-3 PMID:34568955","DOI":"10.1007\/s00784-021-04157-3"},{"key":"3","doi-asserted-by":"publisher","unstructured":"[3] Sanz M,Noguerol B,Sanz-Sanchez I,Hammerle CHF,Schliephake H,Renouard F,<i>et al.<\/i>; Steering Committee. European Association for Osseointegration Delphi study on the trends in implant dentistry in Europe for the year 2030. Clin Oral Implants Res. 2019;30:476\u201386. https:\/\/doi.org\/10.1111\/clr.13431 PMID:31033047","DOI":"10.1111\/clr.13431"},{"key":"4","doi-asserted-by":"publisher","unstructured":"[4] Michelinakis G,Apostolakis D,Kamposiora P,Papavasiliou G,\u00d6zcan M. The direct digital workflow in fixed implant prosthodontics: A narrative review. BMC Oral Health. 2021;21:37. https:\/\/doi.org\/10.1186\/s12903-021-01398-2 PMID:33478459","DOI":"10.1186\/s12903-021-01398-2"},{"key":"5","doi-asserted-by":"publisher","unstructured":"[5] Rutk\u016bnas V,Au\u0161kalnis L,Pletkus J. Intraoral scanners in implant prosthodontics. A narrative review. J Dent. 2024;148:105152. https:\/\/doi.org\/10.1016\/j.jdent.2024.105152 PMID:38909643","DOI":"10.1016\/j.jdent.2024.105152"},{"key":"6","doi-asserted-by":"publisher","unstructured":"[6] Gracis S,Appiani A,No\u00e8 G. Digital workflow in implant prosthodontics: The critical aspects for reliable accuracy. J Esthet Restor Dent. 2023;35:250\u201361. https:\/\/doi.org\/10.1111\/jerd.13004 PMID:36606714","DOI":"10.1111\/jerd.13004"},{"key":"7","doi-asserted-by":"publisher","unstructured":"[7] Graf T,G\u00fcth JF,Diegritz C,Liebermann A,Schweiger J,Schubert O. Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns - cast-free vs 3D printed cast-based. J Adv Prosthodont. 2021;13:351\u201360. https:\/\/doi.org\/10.4047\/jap.2021.13.6.351 PMID:35003551","DOI":"10.4047\/jap.2021.13.6.351"},{"key":"8","doi-asserted-by":"publisher","unstructured":"[8] Schmidt A,W\u00f6stmann B,Schlenz MA. Accuracy of digital implant impressions in clinical studies: A systematic review. Clin Oral Implants Res. 2022;33:573\u201385. https:\/\/doi.org\/10.1111\/clr.13951 PMID:35527511","DOI":"10.1111\/clr.13951"},{"key":"9","doi-asserted-by":"publisher","unstructured":"[9] Revilla-Le\u00f3n M,Kois DE,Kois JC. A guide for maximizing the accuracy of intraoral digital scans. Part 1: Operator factors. J Esthet Restor Dent. 2023;35:230\u201340. https:\/\/doi.org\/10.1111\/jerd.12985 PMID:36479807","DOI":"10.1111\/jerd.12985"},{"key":"10","doi-asserted-by":"publisher","unstructured":"[10] Revilla-Le\u00f3n M,Kois DE,Kois JC. A guide for maximizing the accuracy of intraoral digital scans: Part 2\u2014Patient factors. J Esthet Restor Dent. 2023;35:241\u20139. https:\/\/doi.org\/10.1111\/jerd.12993 PMID:36639916","DOI":"10.1111\/jerd.12993"},{"key":"11","doi-asserted-by":"publisher","unstructured":"[11] G\u00f3mez-Polo M,Donmez MB,\u00c7akmak G,Yilmaz B,Revilla-Le\u00f3n M. Influence of implant scan body design (height, diameter, geometry, material, and retention system) on intraoral scanning accuracy: A systematic review. J Prosthodont. 2023;32:165\u201380. https:\/\/doi.org\/10.1111\/jopr.13774 PMID:37771200","DOI":"10.1111\/jopr.13774"},{"key":"12","doi-asserted-by":"publisher","unstructured":"[12] Gehrke P,Rashidpour M,Sader R,Weigl P. A systematic review of factors impacting intraoral scanning accuracy in implant dentistry with emphasis on scan bodies. Int J Implant Dent. 2024;10:20. https:\/\/doi.org\/10.1186\/s40729-024-00543-0 PMID:38691258","DOI":"10.1186\/s40729-024-00543-0"},{"key":"13","doi-asserted-by":"publisher","unstructured":"[13] Mizumoto RM,Yilmaz B. Intraoral scan bodies in implant dentistry: A systematic review. J Prosthet Dent. 2018;120:343\u201352. https:\/\/doi.org\/10.1016\/j.prosdent.2017.10.029 PMID:29627211","DOI":"10.1016\/j.prosdent.2017.10.029"},{"key":"14","doi-asserted-by":"publisher","unstructured":"[14] Aktas A,Manav TY,Zortuk M. Effect of reusing impression posts and scan bodies on recording accuracy. J Prosthet Dent. 2025;133:1324.e1\u20137. https:\/\/doi.org\/10.1016\/j.prosdent.2025.02.007 PMID:40055085","DOI":"10.1016\/j.prosdent.2025.02.007"},{"key":"15","doi-asserted-by":"publisher","unstructured":"[15] Sawyers J,Baig M,ElMasoud B. Effect of multiple use of impression copings and scanbodies on implant cast accuracy. Int J Oral Maxillofac Implants. 2019;34:891\u20138. https:\/\/doi.org\/10.11607\/jomi.6945 PMID:31107939","DOI":"10.11607\/jomi.6945"},{"key":"16","doi-asserted-by":"publisher","unstructured":"[16] Revilla-Le\u00f3n M,Lanis A,Yilmaz B,Kois JC,Gallucci GO. Intraoral digital implant scans: Parameters to improve accuracy. J Prosthodont. 2023;32:150\u201364. https:\/\/doi.org\/10.1111\/jopr.13749 PMID:37586762","DOI":"10.1111\/jopr.13749"},{"key":"17","unstructured":"[17] Mehl A,Reich S,Beuer F,G\u00fcth JF. Accuracy, trueness, and precision - a guideline for the evaluation of these basic values in digital dentistry. Int J Comput Dent. 2021;24:341\u201352. PMID:34931770"},{"key":"18","unstructured":"[18] CAMLOG Biotechnologies GmbH. Aufbereitungsanweisung f\u00fcr CAMLOG\u00ae\/CONELOG\u00ae Implant system; 2025. [accessed 20 August 2025]. Available from: https:\/\/www.camlog.de\/de\/service\/media-center\/dokumentationen\/katalog-und-prospekte-camlog."},{"key":"19","doi-asserted-by":"publisher","unstructured":"[19] Andriessen FS,Rijkens DR,van der Meer WJ,Wismeijer DW. Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: A pilot study. J Prosthet Dent. 2014;111:186\u201394. https:\/\/doi.org\/10.1016\/j.prosdent.2013.07.010 PMID:24210732","DOI":"10.1016\/j.prosdent.2013.07.010"},{"key":"20","doi-asserted-by":"publisher","unstructured":"[20] Fukazawa S,Odaira C,Kondo H. Investigation of accuracy and reproducibility of abutment position by intraoral scanners. J Prosthodont Res. 2017;61:450\u20139. https:\/\/doi.org\/10.1016\/j.jpor.2017.01.005 PMID:28216020","DOI":"10.1016\/j.jpor.2017.01.005"},{"key":"21","doi-asserted-by":"publisher","unstructured":"[21] Malik J,Rodriguez J,Weisbloom M,Petridis H. Comparison of accuracy between a conventional and two digital intraoral impression techniques. Int J Prosthodont. 2018;31:107\u201313. https:\/\/doi.org\/10.11607\/ijp.5643 PMID:29518805","DOI":"10.11607\/ijp.5643"},{"key":"22","doi-asserted-by":"publisher","unstructured":"[22] Papaspyridakos P,Chen CJ,Gallucci G,Doukoudakis A,Weber HP,Chronopoulos V. Accuracy of implant impressions for partially and completely edentulous patients: A systematic review. Int J Oral Maxillofac Implants. 2014;29:836\u201345. https:\/\/doi.org\/10.11607\/jomi.3625 PMID:25032763","DOI":"10.11607\/jomi.3625"},{"key":"23","doi-asserted-by":"publisher","unstructured":"[23] Stimmelmayr M,G\u00fcth JF,Erdelt K,Edelhoff D,Beuer F. Digital evaluation of the reproducibility of implant scanbody fit\u2014an in vitro study. Clin Oral Investig. 2012;16:851\u20136. https:\/\/doi.org\/10.1007\/s00784-011-0564-5 PMID:21647591","DOI":"10.1007\/s00784-011-0564-5"},{"key":"24","doi-asserted-by":"publisher","unstructured":"[24] Arcuri L,Pozzi A,Lio F,Rompen E,Zechner W,Nardi A. Influence of implant scanbody material, position and operator on the accuracy of digital impression for complete-arch: A randomized in vitro trial. J Prosthodont Res. 2020;64:128\u201336. https:\/\/doi.org\/10.1016\/j.jpor.2019.06.001 PMID:31255546","DOI":"10.1016\/j.jpor.2019.06.001"},{"key":"25","doi-asserted-by":"publisher","unstructured":"[25] Karthhik R,Raj B,Karthikeyan BV. Role of scan body material and shape on the accuracy of complete arch implant digitalization. Journal of Oral Research and Review. 2022;14:114\u201320. https:\/\/doi.org\/10.4103\/jorr.jorr_63_21","DOI":"10.4103\/jorr.jorr_63_21"},{"key":"26","doi-asserted-by":"publisher","unstructured":"[26] Soltan H,Mai X,Ramdan AS,Saleh MQ,Ashour SH,Xie W. Impact of implant scan body material and angulation on the trueness and precision of digital implant impressions using four intraoral scanners\u2013an in vitro study. BMC Oral Health. 2025;25:1288. https:\/\/doi.org\/10.1186\/s12903-025-06502-4 PMID:40745640","DOI":"10.1186\/s12903-025-06502-4"},{"key":"27","doi-asserted-by":"publisher","unstructured":"[27] Kumar A,Yap WT,Foo SL,Lee TK. Effects of sterilization cycles on PEEK for medical device application. Bioengineering (Basel). 2018;5:18. https:\/\/doi.org\/10.3390\/bioengineering5010018 PMID:29466289","DOI":"10.3390\/bioengineering5010018"},{"key":"28","doi-asserted-by":"publisher","unstructured":"[28] Diker E,Terzioglu H,Gouveia DNM,Donmez MB,Seidt J,Yilmaz B. Effect of material type, torque value, and sterilization on linear displacements of a scan body: An in vitro study. Clin Implant Dent Relat Res. 2023;25:419\u201325. https:\/\/doi.org\/10.1111\/cid.13187 PMID:36762614","DOI":"10.1111\/cid.13187"},{"key":"29","unstructured":"[29] Semper W,Heberer S,Mehrhof J,Schink T,Nelson K. Effects of repeated manual disassembly and reassembly on the positional stability of various implant-abutment complexes: An experimental study. Int J Oral Maxillofac Implants. 2010;25:86\u201394. PMID:20209190"},{"key":"30","doi-asserted-by":"publisher","unstructured":"[30] Semper W,Kraft S,Kr\u00fcger T,Nelson K. Theoretical considerations: Implant positional index design. J Dent Res. 2009;88:725\u201330. https:\/\/doi.org\/10.1177\/0022034509341172 PMID:19734459","DOI":"10.1177\/0022034509341172"},{"key":"31","doi-asserted-by":"publisher","unstructured":"[31] Azevedo L,Marques T,Karasan D,Fehmer V,Sailer I,Correia A,<i>et al.<\/i> Influence of implant ScanBody material and intraoral scanners on the accuracy of complete-arch digital implant impressions. Int J Prosthodont. 2024;37:575\u2013582a. https:\/\/doi.org\/10.11607\/ijp.8565 PMID:37729480","DOI":"10.11607\/ijp.8565"},{"key":"32","doi-asserted-by":"publisher","unstructured":"[32] Grande F,Mosca Balma A,Mussano F,Catapano S. Effect of implant scan body type, intraoral scanner and scan strategy on the accuracy and scanning time of a maxillary complete arch implant scans: An in vitro study. J Dent. 2025;159:105782. https:\/\/doi.org\/10.1016\/j.jdent.2025.105782 PMID:40288482","DOI":"10.1016\/j.jdent.2025.105782"},{"key":"33","doi-asserted-by":"publisher","unstructured":"[33] Lee JH,Bae JH,Lee SY. Trueness of digital implant impressions based on implant angulation and scan body materials. Sci Rep. 2021;11:21892. https:\/\/doi.org\/10.1038\/s41598-021-01442-9 PMID:34750515","DOI":"10.1038\/s41598-021-01442-9"},{"key":"34","doi-asserted-by":"publisher","unstructured":"[34] Kato T,Yasunami N,Furuhashi A,Sanda K,Ayukawa Y. Effects of autoclave sterilization and multiple use on implant scanbody deformation in vitro. Materials (Basel). 2022;15:7717. https:\/\/doi.org\/10.3390\/ma15217717 PMID:36363311","DOI":"10.3390\/ma15217717"},{"key":"35","doi-asserted-by":"publisher","unstructured":"[35] Revilla-Le\u00f3n M,Gohil A,Barmak AB,G\u00f3mez-Polo M,P\u00e9rez-Barquero JA,Att W,<i>et al.<\/i> Influence of ambient temperature changes on intraoral scanning accuracy. J Prosthet Dent. 2023;130:755\u201360. https:\/\/doi.org\/10.1016\/j.prosdent.2022.01.012 PMID:35210107","DOI":"10.1016\/j.prosdent.2022.01.012"},{"key":"36","unstructured":"[36] Keul C,G\u00fcth JF. Influence of intraoral conditions on the accuracy of full-arch scans by Cerec Primescan AC: An in vitro and in vivo comparison. Int J Comput Dent. 2022;25:17\u201325. PMID:35322649"},{"key":"37","doi-asserted-by":"publisher","unstructured":"[37] Marques VR,\u00c7akmak G,Yilmaz H,Abou-Ayash S,Donmez MB,Yilmaz B. Effect of scanned area and operator on the accuracy of dentate arch scans with a single implant. J Clin Med. 2022;11:4125. https:\/\/doi.org\/10.3390\/jcm11144125 PMID:35887889","DOI":"10.3390\/jcm11144125"},{"key":"38","unstructured":"[38] Abduo J,Elseyoufi M. Accuracy of intraoral scanners: a systematic review of influencing factors. Eur J Prosthodont Restor Dent. 2018;26:101\u201321. PMID:29989757"},{"key":"39","doi-asserted-by":"publisher","unstructured":"[39] Mangano FG,Hauschild U,Veronesi G,Imburgia M,Mangano C,Admakin O. Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: A comparative in vitro study. BMC Oral Health. 2019;19:101. https:\/\/doi.org\/10.1186\/s12903-019-0792-7 PMID:31170969","DOI":"10.1186\/s12903-019-0792-7"},{"key":"40","doi-asserted-by":"publisher","unstructured":"[40] Revilla-Le\u00f3n M,Aragoneses R,Arroyo Valverde EM,G\u00f3mez-Polo M,Kois JC. Classification of scanning errors of digital scans recorded by using intraoral scanners. J Esthet Restor Dent. 2025;37:1363\u201371. https:\/\/doi.org\/10.1111\/jerd.13419 PMID:39828965","DOI":"10.1111\/jerd.13419"}],"container-title":["Journal of Prosthodontic Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jpr\/advpub\/0\/advpub_JPR_D_25_00308\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,18]],"date-time":"2026-04-18T04:24:22Z","timestamp":1776486262000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jpr\/advpub\/0\/advpub_JPR_D_25_00308\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":40,"URL":"https:\/\/doi.org\/10.2186\/jpr.jpr_d_25_00308","relation":{},"ISSN":["1883-1958","1883-9207"],"issn-type":[{"value":"1883-1958","type":"print"},{"value":"1883-9207","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026]]},"article-number":"JPR_D_25_00308"}}