{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T19:02:11Z","timestamp":1782846131423,"version":"3.54.5"},"reference-count":36,"publisher":"JMIR Publications Inc.","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JMIR Mhealth Uhealth"],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Hypertension is a global public health issue and is closely related to chronic kidney disorder (CKD). In people with CKD, strict monitoring of blood pressure is an important part of therapy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>The aim of this research was to validate the iHealth Track blood pressure monitoring device for patients with CKD according to the European Society of Hypertension International Protocol 2010 (ESH-IP2).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In total, 33 patients who received hemodialysis in Plasencia participated in the study. There were 9 successive measurements made, which conformed to the ESH-IP2. We calculated the differences between the standard reference device (Omron M3 Intellisense) and the test device (iHealth Track) for blood pressure and heart rate values. For 99 total comparisons of paired measurements, we classified differences into various categories (\u22645 mmHg, \u226410 mmHg, and \u226415 mmHg for blood pressure; \u22643, \u22645, and \u22648 beats per minute for heart rate).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>In 90 of 99 systolic blood pressure and 89 of 99 diastolic blood pressure comparisons between the devices, measurement differences were within 5 mmHg. In 81 of 99 heart rate comparisons between the devices, measurement differences were within 3 beats per minute. The mean differences between the test and reference standard measurements were 3.27 (SD 2.99) mmHg for systolic blood pressure, 3.59 (SD 4.55) mmHg for diastolic blood pressure, and 2.18 (SD 2.75) beats per minute for heart rate.\nWe also observed that for both systolic and diastolic blood pressure, 31 of 33 participants had at least two of three comparisons between the devices with measurement differences less than 5 mmHg. For heart rate, 28 of 33 patients had at least two of three comparisons between the devices with measurement differences less than 3 beats per minute.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>To our knowledge, this is the first study to show that iHealth Track meets the requirements of the ESH-IP2 in patients with CKD. Therefore, the iHealth Track is suitable for use in renal patients.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2196\/14702","type":"journal-article","created":{"date-parts":[[2020,1,27]],"date-time":"2020-01-27T19:48:46Z","timestamp":1580154526000},"page":"e14702","source":"Crossref","is-referenced-by-count":5,"title":["An Automated Blood Pressure Display for Self-Measurement in Patients With Chronic Kidney Disease (iHealth Track): Device Validation Study"],"prefix":"10.2196","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5741-7606","authenticated-orcid":false,"given":"Victoria","family":"Mazoteras-Pardo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1568-7602","authenticated-orcid":false,"given":"Ricardo","family":"Becerro-De-Bengoa-Vallejo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7588-2069","authenticated-orcid":false,"given":"Marta Elena","family":"Losa-Iglesias","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9818-6290","authenticated-orcid":false,"given":"Daniel","family":"L\u00f3pez-L\u00f3pez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6569-1311","authenticated-orcid":false,"given":"C\u00e9sar","family":"Calvo-Lobo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3629-6590","authenticated-orcid":false,"given":"David","family":"Rodr\u00edguez-Sanz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0926-5200","authenticated-orcid":false,"given":"Eva Mar\u00eda","family":"Mart\u00ednez-Jim\u00e9nez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3821-949X","authenticated-orcid":false,"given":"Patricia","family":"Palomo-L\u00f3pez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1010","published-online":{"date-parts":[[2020,4,2]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1038\/kisup.2012.73"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1038\/nrneph.2017.52"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(13)60687-X"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.semnephrol.2017.02.005"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.kint.2016.03.021"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1038\/nrneph.2015.172"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2009.09.014"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1681\/asn.2015030243"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1038\/nrdp.2017.88"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.108.110635"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000001940"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2014.04.065"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1681\/ASN.2017020148"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1161\/hypertensionaha.115.06896"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-159-3-201308060-00008"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000000673"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1038\/hr.2012.56"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1097\/01.hjh.0000431740.32696.cc"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1097\/00004872-199306000-00013"},{"key":"ref20","unstructured":"ANSI\/AAMI\/ISO 81060- 2:2013Association For The Advancement Of Medical InstrumentationNon-invasive sphygmomanometers \u2014 Part 2: Clinical investigation of automated measurement typehttp:\/\/my.aami.org\/aamiresources\/previewfiles\/8106002_1306_preview.pdf"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1097\/00126097-200202000-00002"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e3283360e98"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1097\/hjh.0000000000001634"},{"key":"ref24","unstructured":"Asociaci\u00f3n M\u00e9dica Mundial2013102019-03-04Declaraci\u00f3n de Helsinki de la Amm - principios \u00e9ticos para las investigaciones m\u00e9dicas en seres humanoshttps:\/\/www.wma.net\/es\/policies-post\/declaracion-de-helsinki-de-la-amm-principios- eticos-para-las-investigaciones-medicas-en-seres-humanos\/"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e3283354b11"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1159\/000330719"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1016\/s0140-6736(95)91748-9"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.2196\/13137"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1038\/jhh.2010.54"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1097\/mbp.0b013e328108f544"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1097\/00126097-199910000-00003"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1097\/01.mbp.0000172713.28029.84"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1097\/mbp.0b013e328331d5b5"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.2147\/VHRM.S27193"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000002039"}],"container-title":["JMIR mHealth and uHealth"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/mhealth.jmir.org\/2020\/4\/e14702","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T18:05:50Z","timestamp":1782842750000},"score":1,"resource":{"primary":{"URL":"https:\/\/mhealth.jmir.org\/2020\/4\/e14702"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,2]]},"references-count":36,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.2196\/14702","relation":{"has-preprint":[{"id-type":"doi","id":"10.2196\/preprints.14702","asserted-by":"object"}]},"ISSN":["2291-5222"],"issn-type":[{"value":"2291-5222","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,2]]}}}