{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,11]],"date-time":"2026-11-11T00:00:54Z","timestamp":1794355254939,"version":"4.9.0"},"reference-count":54,"publisher":"JMIR Publications Inc.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JMIR Cardio"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec sec-type=\"background\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Heart rate (HR) is a vital physiological parameter, serving as an indicator of homeostasis and a key metric for monitoring cardiovascular health and physiological responses. Wearable devices using photoplethysmography (PPG) technology provide noninvasive HR monitoring in real-life settings, but their performance may vary due to factors such as wearing position, blood flow, motion, and device updates. Therefore, ongoing validation of their accuracy and reliability across different activities is essential.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"objectives\">\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>This study aimed to assess the accuracy and reliability of the HR measurement from the PPG-based Polar Verity Sense and the Polar Vantage V2 devices across a range of physical activities and intensities as well as wearing positions (ie, upper arm, forearm, and both wrists).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Sixteen healthy participants were recruited to participate in this study protocol, which involved 9 activities of varying intensities, ranging from lying down to high-intensity interval training, each repeated twice. The HR measurements from the Verity Sense and Vantage V2 were compared with the criterion measure Polar H10 electrocardiogram (ECG) chest strap. The data were processed to eliminate artifacts and outliers. Accuracy and reliability were assessed using multiple statistical methods, including systematic bias (mean of differences), mean absolute error (MAE) and mean absolute percentage error (MAPE), Pearson product moment correlation coefficient (\n                      <jats:italic>r<\/jats:italic>\n                      ), Lin concordance correlation coefficient (CCC), and within-subject coefficient of variation (WSCV).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      All 16 participants (female=7; male=9; mean 27.4, SD 5.8 years) completed the study. The Verity Sense, worn on the upper arm, demonstrated excellent accuracy across most activities, with a systematic bias of \u22120.05 bpm, MAE of 1.43 bpm, MAPE of 1.35%,\n                      <jats:italic>r<\/jats:italic>\n                      =1.00, and CCC=1.00. It also demonstrated high reliability across all activities with a WSCV of 2.57% and no significant differences between the 2 sessions. The wrist-worn Vantage V2 demonstrated moderate accuracy with a slight overestimation compared with the ECG and considerable variation in accuracy depending on the activity. For the nondominant wrist, it demonstrated a systematic bias of 2.56 bpm, MAE of 6.41 bpm, MAPE 6.82%,\n                      <jats:italic>r<\/jats:italic>\n                      =0.93, and CCC=0.92. Reliability varied considerably, ranging from a WSCV of 3.64% during postexercise sitting to 23.03% during lying down.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"conclusions\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The Verity Sense was found to be highly accurate and reliable, outperforming many other wearable HR devices and establishing itself as a strong alternative to ECG-based chest straps, especially when worn on the upper arm. The Vantage V2 was found to have moderate accuracy, with performance highly dependent on activity type and intensity. While it exhibited greater variability and limitations at lower HR, it performed better at higher intensities and outperformed several wrist-worn devices from previous research, particularly during vigorous activities. These findings highlight the importance of device selection and wearing position to ensure the highest possible accuracy in the intended context.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2196\/67110","type":"journal-article","created":{"date-parts":[[2025,2,11]],"date-time":"2025-02-11T16:30:06Z","timestamp":1739291406000},"page":"e67110-e67110","source":"Crossref","is-referenced-by-count":31,"title":["Wrist-Worn and Arm-Worn Wearables for Monitoring Heart Rate During Sedentary and Light-to-Vigorous Physical Activities: Device Validation Study"],"prefix":"10.2196","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6816-2100","authenticated-orcid":false,"given":"Theresa","family":"Schweizer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2323-7302","authenticated-orcid":false,"given":"Rahel","family":"Gilgen-Ammann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1010","published-online":{"date-parts":[[2025,3,21]]},"reference":[{"issue":"22","key":"R1","doi-asserted-by":"publisher","DOI":"10.3390\/s22228903","article-title":"Wearable devices for remote monitoring of heart rate and heart rate variability\u2014what we know and what is coming","volume":"22","author":"Alugubelli","journal-title":"Sensors (Basel)"},{"issue":"15","key":"R2","doi-asserted-by":"publisher","first-page":"E384","DOI":"10.1503\/cmaj.160050","article-title":"Association between resting heart rate and coronary artery disease, stroke, sudden death and noncardiovascular diseases: a meta-analysis","volume":"188","author":"Zhang","journal-title":"CMAJ"},{"key":"R3","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2021.790292","article-title":"Fatigue monitoring through wearables: a state-of-the-art review","volume":"12","author":"Ad\u00e3o Martins","journal-title":"Front Physiol"},{"issue":"7","key":"R4","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1088\/0967-3334\/34\/7\/781","article-title":"Estimation of human core temperature from sequential heart rate observations","volume":"34","author":"Buller","journal-title":"Physiol Meas"},{"issue":"10","key":"R5","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1088\/1361-6579\/acf991","article-title":"Individualized monitoring of heat illness risk: novel adaptive physiological strain index to assess exercise-heat strain from athletes to fully encapsulated workers","volume":"44","author":"Buller","journal-title":"Physiol Meas"},{"key":"R6","doi-asserted-by":"publisher","DOI":"10.2196\/57373","article-title":"Validation of a wearable sensor prototype for measuring heart rate to prescribe physical activity: cross-sectional exploratory study","volume":"9","author":"Loro","journal-title":"JMIR Biomed Eng"},{"issue":"4","key":"R7","doi-asserted-by":"publisher","DOI":"10.3390\/s21041061","article-title":"Wearable devices suitable for monitoring twenty four hour heart rate variability in military populations","volume":"21","author":"Hinde","journal-title":"Sensors (Basel)"},{"issue":"17","key":"R8","doi-asserted-by":"publisher","DOI":"10.3390\/s22176536","article-title":"Validity of the Polar H10 sensor for heart rate variability analysis during resting state and incremental exercise in recreational men and women","volume":"22","author":"Schaffarczyk","journal-title":"Sensors (Basel)"},{"issue":"4","key":"R9","doi-asserted-by":"publisher","first-page":"411","DOI":"10.33678\/cor.2022.083","article-title":"Feasibility of evaluation of Polar H10 chest-belt ECG in patients with a broad range of heart conditions","volume":"64","author":"Sk\u00e1la","journal-title":"Cor Vasa"},{"issue":"Suppl 1","key":"R10","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euad122.550","article-title":"Validation of Polar H10 chest strap and Fitbit Inspire 2 tracker for measuring continuous heart rate in cardiac patients: impact of artefact removal algorithm","volume":"25","author":"Vermunicht","journal-title":"Europace"},{"issue":"7","key":"R11","doi-asserted-by":"publisher","first-page":"1525","DOI":"10.1007\/s00421-019-04142-5","article-title":"RR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exercise","volume":"119","author":"Gilgen-Ammann","journal-title":"Eur J Appl Physiol"},{"issue":"1","key":"R12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/24725838.2018.1435431","article-title":"The wearing comfort and acceptability of ambulatory physical activity monitoring devices in soldiers","volume":"6","author":"Beeler","journal-title":"IISE Trans Occup Ergon Hum Factors"},{"key":"R13","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2018.00743","article-title":"A critical review of consumer wearables, mobile applications, and equipment for providing biofeedback, monitoring stress, and sleep in physically active populations","volume":"9","author":"Peake","journal-title":"Front Physiol"},{"issue":"3","key":"R14","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1088\/0031-9155\/19\/3\/003","article-title":"A photoelectric plethysmograph for the measurement of cutaneous blood flow","volume":"19","author":"Challoner","journal-title":"Phys Med Biol"},{"issue":"4","key":"R15","doi-asserted-by":"publisher","DOI":"10.2196\/mhealth.9341","article-title":"Recommendations for assessment of the reliability, sensitivity, and validity of data provided by wearable sensors designed for monitoring physical activity","volume":"6","author":"D\u00fcking","journal-title":"JMIR Mhealth Uhealth"},{"key":"R16","doi-asserted-by":"publisher","DOI":"10.1016\/j.cobme.2019.01.001","article-title":"Windows into human health through wearables data analytics","volume":"9","author":"Witt","journal-title":"Curr Opin Biomed Eng"},{"issue":"1","key":"R17","doi-asserted-by":"publisher","DOI":"10.1186\/s13102-023-00783-4","article-title":"From data to action: a scoping review of wearable technologies and biomechanical assessments informing injury prevention strategies in sport","volume":"15","author":"Rebelo","journal-title":"BMC Sports Sci Med Rehabil"},{"key":"R18","doi-asserted-by":"publisher","DOI":"10.2196\/56972","article-title":"Real-world accuracy of wearable activity trackers for detecting medical conditions: systematic review and meta-analysis","volume":"12","author":"Singh","journal-title":"JMIR Mhealth Uhealth"},{"key":"R19","doi-asserted-by":"crossref","unstructured":"Barrios L Oldrati P Santini S Lutterotti A . Evaluating the accuracy of heart rate sensors based on photoplethysmography for in-the-wild analysis. Presented at: PervasiveHealth\u201919: Proceedings of the 13th EAI International Conference on Pervasive Computing Technologies for Healthcare; May 20-23, 2019:251-261; Trento, Italy. [doi: 10.1145\/3329189.3329215]","DOI":"10.1145\/3329189.3329215"},{"issue":"8","key":"R20","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0238569","article-title":"Concurrent heart rate validity of wearable technology devices during trail running","volume":"15","author":"Navalta","journal-title":"PLoS One"},{"issue":"1","key":"R21","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-38329-w","article-title":"Heart rate processing algorithms and exercise duration on reliability and validity decisions in biceps-worn Polar Verity Sense and OH1 wearables","volume":"13","author":"Navalta","journal-title":"Sci Rep"},{"issue":"4","key":"R22","doi-asserted-by":"publisher","first-page":"195","DOI":"10.15406\/ijbsbe.2018.04.00125","article-title":"A review on wearable photoplethysmography sensors and their potential future applications in health care","volume":"4","author":"Castaneda","journal-title":"Int J Biosens Bioelectron"},{"key":"R23","doi-asserted-by":"crossref","unstructured":"Shimazaki T Kuwahara Y Kimoto M Hara S Yomo H . Effect of position and fastening belt pressure on the accuracy of PPG-based heart rate sensor. Presented at: 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC); Jul 18-21, 2018:4323-4326; Honolulu, HI. [doi: 10.1109\/EMBC.2018.8513333]","DOI":"10.1109\/EMBC.2018.8513333"},{"issue":"2","key":"R24","doi-asserted-by":"publisher","first-page":"282","DOI":"10.3390\/electronics3020282","article-title":"Wearable photoplethysmographic sensors\u2014past and present","volume":"3","author":"Tamura","journal-title":"Electronics (Basel)"},{"issue":"3","key":"R25","doi-asserted-by":"publisher","first-page":"673","DOI":"10.3390\/s19030673","article-title":"Motion artifact reduction for wrist-worn photoplethysmograph sensors based on different wavelengths","volume":"19","author":"Zhang","journal-title":"Sensors (Basel)"},{"issue":"14","key":"R26","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1136\/bjsports-2020-103148","article-title":"Recommendations for determining the validity of consumer wearable heart rate devices: expert statement and checklist of the INTERLIVE Network","volume":"55","author":"M\u00fchlen","journal-title":"Br J Sports Med"},{"issue":"9","key":"R27","doi-asserted-by":"publisher","DOI":"10.3390\/sports12090234","article-title":"Validity and reliability of wearable technology devices during simulated pickleball game play","volume":"12","author":"Navalta","journal-title":"Sports (Basel)"},{"issue":"3","key":"R28","doi-asserted-by":"publisher","first-page":"23","DOI":"10.26773\/smj.231004","article-title":"Validity and reliability of wearable devices during self-paced walking, jogging and overground skipping","volume":"21","author":"Navalta","journal-title":"Sport Mont"},{"issue":"12","key":"R29","doi-asserted-by":"publisher","first-page":"2623","DOI":"10.1111\/sms.14494","article-title":"Validity of the polar verity sense during swimming at different locations and intensities","volume":"33","author":"L\u00f3pez-Belmonte","journal-title":"Scand J Med Sci Sports"},{"issue":"9S","key":"R30","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1249\/01.mss.0000877508.29887.33","article-title":"Validity of average heart rate and energy expenditure in Polar Armband devices while self-paced biking","volume":"54","author":"Fullmer","journal-title":"Med Sci Sports Exerc"},{"issue":"11","key":"R31","doi-asserted-by":"publisher","DOI":"10.1111\/sms.14756","article-title":"Validity of four consumer-grade optical heart rate sensors for assessing volume and intensity distribution of physical activity","volume":"34","author":"Neudorfer","journal-title":"Scand J Med Sci Sports"},{"issue":"13","key":"R32","doi-asserted-by":"publisher","DOI":"10.3390\/s22134726","article-title":"Accuracy and precision of wearable devices for real-time monitoring of swimming athletes","volume":"22","author":"Cosoli","journal-title":"Sensors (Basel)"},{"issue":"5","key":"R33","doi-asserted-by":"publisher","DOI":"10.2196\/16716","article-title":"Wrist-worn wearables for monitoring heart rate and energy expenditure while sitting or performing light-to-vigorous physical activity: validation study","volume":"8","author":"D\u00fcking","journal-title":"JMIR Mhealth Uhealth"},{"key":"R34","unstructured":"World Health Organization. Physical activity. 2024. URL: https:\/\/www.who.int\/news-room\/fact-sheets\/detail\/physical-activity [Accessed 27-02-2025]"},{"issue":"6","key":"R35","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1001\/archderm.124.6.869","article-title":"The validity and practicality of sun-reactive skin types I through VI","volume":"124","author":"Fitzpatrick","journal-title":"Arch Dermatol"},{"issue":"2","key":"R36","doi-asserted-by":"publisher","first-page":"92","DOI":"10.2340\/1650197719702239298","article-title":"Perceived exertion as an indicator of somatic stress","volume":"2","author":"Borg","journal-title":"Scand J Rehabil Med"},{"issue":"2","key":"R37","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1016\/s0001-6918(01)00055-5","article-title":"A comparison of AME and CR100 for scaling perceived exertion","volume":"109","author":"Borg","journal-title":"Acta Psychol (Amst)"},{"key":"R38","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-020-0226-6","article-title":"Investigating sources of inaccuracy in wearable optical heart rate sensors","volume":"3","author":"Bent","journal-title":"NPJ Digit Med"},{"key":"R39","doi-asserted-by":"publisher","DOI":"10.3233\/SHTI220370","article-title":"Accuracy of wearable photoplethysmography sensors for continuous heart rate monitoring in telehealth applications","volume":"293","author":"Vinatzer","journal-title":"Stud Health Technol Inform"},{"key":"R40","doi-asserted-by":"crossref","unstructured":"Goldberger A Goldberger Z Shvilkin A . Chapter 13: Sinus and escape rhythms. In: Goldberger\u2019s Clinical Electrocardiography. 8thed. WB Saunders; 2013:114-120. [doi: 10.1016\/B978-0-323-08786-5.00013-0]","DOI":"10.1016\/B978-0-323-08786-5.00013-0"},{"key":"R41","doi-asserted-by":"crossref","unstructured":"Joosen P Exadaktylos V Taelman J Aerts JM Berckmans D . Method for artefact detection and removal in heart rate signals measured during physical exercise. Presented at: Proceedings of the International Congress on Cardiovascular Technologies; 57-61; Villamoura, Portugal. 2013.[doi: 10.5220\/0004636800570061]","DOI":"10.5220\/0004636800570061"},{"issue":"3","key":"R42","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1249\/MSS.0000000000001471","article-title":"Validity of wearable activity monitors during cycling and resistance exercise","volume":"50","author":"Boudreaux","journal-title":"Med Sci Sports Exerc"},{"issue":"3","key":"R43","doi-asserted-by":"publisher","DOI":"10.2196\/33635","article-title":"Heart rate measurement accuracy of Fitbit Charge 4 and Samsung Galaxy Watch Active2: device evaluation study","volume":"6","author":"Nissen","journal-title":"JMIR Form Res"},{"key":"R44","unstructured":"McBride GB . A proposal for strength-of-agreement criteria for Lin\u2019s concordance correlation coefficient. NIWA client report: HAM2005-062. National Institute of Water & Atmospheric Research Ltd; 2005. URL: https:\/\/www.medcalc.org\/download\/pdf\/McBride2005.pdf [Accessed 21-12-2024]"},{"issue":"1","key":"R45","doi-asserted-by":"publisher","first-page":"255","DOI":"10.2307\/2532051","article-title":"A concordance correlation coefficient to evaluate reproducibility","volume":"45","author":"Lin","journal-title":"Biometrics"},{"issue":"2","key":"R46","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1177\/1536867X0200200206","article-title":"A note on the concordance correlation coefficient","volume":"2","author":"Steichen","journal-title":"Stata J Promot Commun Stat Stata"},{"key":"R47","unstructured":"Hopkins W . Validity thresholds and error rates for test measures used to assess individuals. In: Baca A Wessner B Diketm\u00fcller R Tschan H Hofmann M Kornfeind P Tsolakidis E , editors. Book of Abstracts of the 21st Annual Congress of the European College of Sport Science. European College of Sport Science; 2016:6-9. ISBN: 978-3-00-053383-9"},{"issue":"3","key":"R48","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1080\/1091367X.2022.2161820","article-title":"Validation of Garmin and Polar devices for continuous heart rate monitoring during common training movements in tactical populations","volume":"27","author":"Merrigan","journal-title":"Meas Phys Educ Exerc Sci"},{"issue":"4","key":"R49","doi-asserted-by":"publisher","first-page":"379","DOI":"10.21037\/cdt.2019.06.05","article-title":"Accuracy of commercially available heart rate monitors in athletes: a prospective study","volume":"9","author":"Pasadyn","journal-title":"Cardiovasc Diagn Ther"},{"issue":"12","key":"R50","doi-asserted-by":"publisher","first-page":"1411","DOI":"10.1080\/02640414.2018.1560644","article-title":"Heart rate measures from the Apple Watch, Fitbit Charge HR 2, and electrocardiogram across different exercise intensities","volume":"37","author":"Thomson","journal-title":"J Sports Sci"},{"issue":"5","key":"R51","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1213\/ANE.0000000000002864","article-title":"Correlation coefficients: appropriate use and interpretation","volume":"126","author":"Schober","journal-title":"Anesth Analg"},{"issue":"4","key":"R52","doi-asserted-by":"publisher","DOI":"10.2196\/14707","article-title":"Accuracy of optical heart rate sensing technology in wearable fitness trackers for young and older adults: validation and comparison study","volume":"8","author":"Chow","journal-title":"JMIR Mhealth Uhealth"},{"issue":"10","key":"R53","doi-asserted-by":"publisher","DOI":"10.2196\/14120","article-title":"Heart rate measures from wrist-worn activity trackers in a laboratory and free-living setting: validation study","volume":"7","author":"M\u00fcller","journal-title":"JMIR Mhealth Uhealth"},{"issue":"1","key":"R54","doi-asserted-by":"publisher","DOI":"10.3390\/s22010180","article-title":"Heart rate and distance measurement of two multisport activity trackers and a cell phone app in different sports: a cross-sectional validation and comparison field study","volume":"22","author":"Budig","journal-title":"Sensors (Basel)"}],"container-title":["JMIR Cardio"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/cardio.jmir.org\/2025\/1\/e67110","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T22:28:12Z","timestamp":1785536892000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardio.jmir.org\/2025\/1\/e67110"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,21]]},"references-count":54,"URL":"https:\/\/doi.org\/10.2196\/67110","relation":{},"ISSN":["2561-1011"],"issn-type":[{"value":"2561-1011","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,21]]},"article-number":"v9i22e67110"}}