{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T18:57:30Z","timestamp":1782845850213,"version":"3.54.5"},"reference-count":36,"publisher":"JMIR Publications Inc.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JMIR Cardio"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec sec-type=\"background\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Exercise capacity and lifestyle have proven to be important prognostic factors for cardiovascular patients. Both can be ameliorated through different preventive interventions. Cardiac rehabilitation and remote patient monitoring have been proven to reduce cardiac events and cardiovascular mortality. One of the most important goals of cardiac rehabilitation and remote patient monitoring is improving physical fitness and monitoring of cardiovascular parameters, which could predict cardiac deterioration. In order to monitor cardiac patients successfully, reliable and nonobtrusive devices to assess physical activity and cardiovascular parameters need to be available.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"objective\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This validation study aims to determine the accuracy of the Philips Health Band (PHB), a noninvasive, wrist-worn, medically certified device, for the assessment of heart rate (HR) and energy expenditure (EE) in patients with chronic cardiovascular diseases and recreational athletes (RAs).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The assessment of HR and EE by the PHB was compared with indirect calorimetry (Oxycon Mobile [OM; CareFusion GmbH]) during an activity protocol consisting of daily activities. Three groups were assessed: patients with heart failure with reduced ejection fraction (HFrEF), patients with stable coronary artery disease (CAD) with preserved left ventricular ejection fraction, and RAs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 57 patients were included: 19 with CAD, 19 with HFrEF, and 19 RAs. HR assessment in the HFrEF and CAD groups was significantly underestimated over the entire protocol by the PHB as compared to the OM, with poor and fair reliability, respectively. No significant difference in HR was found between the PHB and OM over the entire protocol for the RA group, with good reliability (HFrEF: mean difference 3.0;\n                      <jats:italic>P<\/jats:italic>\n                      &lt;.001; intraclass correlation coefficient [ICC] 0.36; CAD: mean difference 2.7;\n                      <jats:italic>P<\/jats:italic>\n                      &lt;.001; ICC 0.55; RA: mean difference 0.8; ICC 0.60). Assessment of EE showed an underestimation over the entire protocol for the RA and CAD group, with poor and fair reliability, respectively. The HFrEF group showed no significant difference in EE assessment over the entire protocol, with poor reliability (HFrEF: mean difference 0.09; ICC 0.32; CAD: mean difference 0.29;\n                      <jats:italic>P<\/jats:italic>\n                      &lt;.001; ICC 0.46; RA: mean difference 0.79;\n                      <jats:italic>P<\/jats:italic>\n                      &lt;.001; ICC 0.26). The responsiveness to detect within-patient changes in activity intensity of the PHB was moderate for the HFrEF and CAD groups and acceptable for the RA group.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"conclusions\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>HR and EE assessment of a medically certified noninvasive sensor using a photoplethysmogram and accelerometer showed poor accuracy and moderate responsiveness during an activity protocol reflecting daily living activities in patients with stable CAD and chronic HFrEF. Accuracy of HR in RAs was good and the responsiveness for both HR and EE was acceptable. This research confirms previous research and stresses the need for better patient-specific algorithms in noninvasive sensors, taking cardiovascular pathology and medication usage into account, for assessing HR and EE prior to their implemention in patient care.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2196\/69343","type":"journal-article","created":{"date-parts":[[2025,8,6]],"date-time":"2025-08-06T04:47:12Z","timestamp":1754455632000},"page":"e69343-e69343","source":"Crossref","is-referenced-by-count":0,"title":["Analysis of a Medically Certified, Wrist-Worn Sensor for the Assessment of Heart Rate and Energy Expenditure During Daily Activities in Patients With Chronic Heart Failure or Coronary Artery Disease and Recreational Athletes: Validation Study"],"prefix":"10.2196","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-6639-9428","authenticated-orcid":false,"given":"Ignace L J","family":"De Lathauwer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4946-6288","authenticated-orcid":false,"given":"Valerie A A","family":"van Es","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5048-3747","authenticated-orcid":false,"given":"Mayke M C J","family":"van Leunen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-9009-3549","authenticated-orcid":false,"given":"Steven","family":"Onkelinx","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8409-2357","authenticated-orcid":false,"given":"Rutger W M","family":"Brouwers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8553-5025","authenticated-orcid":false,"given":"Danny A J P","family":"van de Sande","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5877-2802","authenticated-orcid":false,"given":"Mathias","family":"Funk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0272-4355","authenticated-orcid":false,"given":"Hareld M C","family":"Kemps","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1010","published-online":{"date-parts":[[2025,9,30]]},"reference":[{"issue":"10","key":"R1","doi-asserted-by":"publisher","first-page":"e56","DOI":"10.1161\/CIR.0000000000000659","article-title":"Heart disease and stroke statistics-2019 update: a report from the American Heart Association","volume":"139","author":"Benjamin","journal-title":"Circulation"},{"issue":"2","key":"R2","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1177\/26324636231158460","article-title":"Effects of exercise training and physical activity in patients with coronary artery disease","volume":"4","author":"Vooturi","journal-title":"Indian J Clin Cardiol"},{"issue":"1","key":"R3","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-98172-9","article-title":"Impact of exercise capacity on the long-term incidence of atrial arrhythmias in heart failure","volume":"11","author":"Sakai","journal-title":"Sci Rep"},{"issue":"11","key":"R4","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1056\/NEJMoa011858","article-title":"Exercise capacity and mortality among men referred for exercise testing","volume":"346","author":"Myers","journal-title":"N Engl J Med"},{"issue":"1","key":"R5","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1093\/eurjpc\/zwab007","article-title":"Exercise intensity assessment and prescription in cardiovascular rehabilitation and beyond: why and how: a position statement from the secondary prevention and rehabilitation section of the European Association of Preventive Cardiology","volume":"29","author":"Hansen","journal-title":"Eur J Prev Cardiol"},{"issue":"10","key":"R6","doi-asserted-by":"publisher","first-page":"682","DOI":"10.1016\/j.amjmed.2004.01.009","article-title":"Exercise-based rehabilitation for patients with coronary heart disease: systematic review and meta-analysis of randomized controlled trials","volume":"116","author":"Taylor","journal-title":"Am J Med"},{"issue":"16","key":"R7","doi-asserted-by":"publisher","first-page":"1967","DOI":"10.1093\/eurheartj\/ehq236","article-title":"Secondary prevention through cardiac rehabilitation: physical activity counselling and exercise training: key components of the position paper from the Cardiac Rehabilitation Section of the European Association of Cardiovascular Prevention and Rehabilitation","volume":"31","author":"European Association of Cardiovascular Prevention and Rehabilitation Committee for Science Guidelines","journal-title":"Eur Heart J"},{"issue":"2","key":"R8","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1177\/2047487312439497","article-title":"Cardiac rehabilitation uptake and its determinants in the Netherlands","volume":"20","author":"van Engen-Verheul","journal-title":"Eur J Prev Cardiol"},{"issue":"5","key":"R9","doi-asserted-by":"publisher","first-page":"899","DOI":"10.1136\/jim-2016-000199","article-title":"Clinical effectiveness of telemedicine for chronic heart failure: a systematic review and meta-analysis","volume":"65","author":"Lin","journal-title":"J Investig Med"},{"issue":"2","key":"R10","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1007\/s10741-019-09801-5","article-title":"Effectiveness of telemedicine systems for adults with heart failure: a meta-analysis of randomized controlled trials","volume":"25","author":"Zhu","journal-title":"Heart Fail Rev"},{"issue":"10152","key":"R11","doi-asserted-by":"publisher","first-page":"1047","DOI":"10.1016\/S0140-6736(18)31880-4","article-title":"Efficacy of telemedical interventional management in patients with heart failure (TIM-HF2): a randomised, controlled, parallel-group, unmasked trial","volume":"392","author":"Koehler","journal-title":"Lancet"},{"key":"R12","doi-asserted-by":"publisher","DOI":"10.1002\/ejhf.3568","article-title":"Remote patient monitoring in heart failure: a comprehensive meta\u2010analysis of effective programme components for hospitalization and mortality reduction","author":"De Lathauwer","journal-title":"Eur J Heart Fail"},{"issue":"1","key":"R13","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1007\/s00769-006-0191-z","article-title":"Understanding the meaning of accuracy, trueness and precision","volume":"12","author":"Menditto","journal-title":"Accred Qual Assur"},{"issue":"5","key":"R14","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0154420","article-title":"Accuracy of heart rate watches: implications for weight management","volume":"11","author":"Wallen","journal-title":"PLoS One"},{"issue":"2","key":"R15","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0171720","article-title":"Assessment of laboratory and daily energy expenditure estimates from consumer multi-sensor physical activity monitors","volume":"12","author":"Chowdhury","journal-title":"PLoS ONE"},{"issue":"15","key":"R16","doi-asserted-by":"publisher","first-page":"1734","DOI":"10.1080\/02640414.2017.1412235","article-title":"Comparative evaluation of heart rate-based monitors: Apple Watch vs Fitbit Charge HR","volume":"36","author":"Bai","journal-title":"J Sports Sci"},{"issue":"2","key":"R17","doi-asserted-by":"publisher","DOI":"10.3390\/jpm7020003","article-title":"Accuracy in wrist-worn, sensor-based measurements of heart rate and energy expenditure in a diverse cohort","volume":"7","author":"Shcherbina","journal-title":"J Pers Med"},{"issue":"12","key":"R18","doi-asserted-by":"publisher","DOI":"10.2196\/15045","article-title":"Usefulness of modern activity trackers for monitoring exercise behavior in chronic cardiac patients: validation study","volume":"7","author":"Herkert","journal-title":"JMIR mHealth uHealth"},{"issue":"3","key":"R19","doi-asserted-by":"publisher","DOI":"10.2196\/11889","article-title":"Accuracy of Apple watch measurements for heart rate and energy expenditure in patients with cardiovascular disease: cross-sectional study","volume":"7","author":"Falter","journal-title":"JMIR mHealth uHealth"},{"issue":"1","key":"R20","doi-asserted-by":"publisher","DOI":"10.2196\/30791","article-title":"Accuracy and acceptability of wrist-wearable activity-tracking devices: systematic review of the literature","volume":"24","author":"Germini","journal-title":"J Med Internet Res"},{"issue":"38","key":"R21","doi-asserted-by":"publisher","first-page":"2949","DOI":"10.1093\/eurheartj\/eht296","article-title":"2013 ESC guidelines on the management of stable coronary artery disease: the Task Force on the management of stable coronary artery disease of the European Society of Cardiology","volume":"34","author":"Task Force Members","journal-title":"Eur Heart J"},{"issue":"6","key":"R22","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1111\/j.1600-0838.2007.00768.x","article-title":"Risk factors for lower extremity injuries among male marathon runners","volume":"18","author":"Van Middelkoop","journal-title":"Scand J Med Sci Sports"},{"issue":"16","key":"R23","doi-asserted-by":"publisher","first-page":"1734","DOI":"10.1177\/2047487316667786","article-title":"Energy expenditure estimation in beta-blocker-medicated cardiac patients by combining heart rate and body movement data","volume":"23","author":"Kraal","journal-title":"Eur J Prev Cardiol"},{"issue":"2","key":"R24","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1007\/s00421-009-1326-9","article-title":"Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method","volume":"109","author":"Rosdahl","journal-title":"Eur J Appl Physiol"},{"issue":"1-2","key":"R25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1113\/jphysiol.1949.sp004363","article-title":"New methods for calculating metabolic rate with special reference to protein metabolism","volume":"109","author":"WEIR","journal-title":"J Physiol"},{"issue":"1","key":"R26","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1109\/87.974338","article-title":"Outliers in process modeling and identification","volume":"10","author":"Pearson","journal-title":"IEEE Trans Contr Syst Technol"},{"issue":"1","key":"R27","doi-asserted-by":"publisher","first-page":"52","DOI":"10.5395\/rde.2013.38.1.52","article-title":"Statistical notes for clinical researchers: assessing normal distribution (2) using skewness and kurtosis","volume":"38","author":"Kim","journal-title":"Restor Dent Endod"},{"issue":"4","key":"R28","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1037\/1040-3590.6.4.284","article-title":"Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology","volume":"6","author":"Cicchetti","journal-title":"Psychol Assess"},{"key":"R29","doi-asserted-by":"publisher","DOI":"10.1016\/j.jelectrocard.2021.06.009","article-title":"The accuracy of heartbeat detection using photoplethysmography technology in cardiac patients","volume":"67","author":"Blok","journal-title":"J Electrocardiol"},{"issue":"1","key":"R30","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/LSENS.2018.2878207","article-title":"Heart rate monitoring during physical exercise from photoplethysmography using neural network","volume":"3","author":"Zhu","journal-title":"IEEE Sens Lett"},{"issue":"4","key":"R31","doi-asserted-by":"publisher","first-page":"261","DOI":"10.5535\/arm.23019","article-title":"Validation of wearable digital devices for heart rate measurement during exercise test in patients with coronary artery disease","volume":"47","author":"Kim","journal-title":"Ann Rehabil Med"},{"issue":"4","key":"R32","doi-asserted-by":"publisher","DOI":"10.3390\/bios11040126","article-title":"Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring","volume":"11","author":"Fine","journal-title":"Biosensors (Basel)"},{"key":"R33","doi-asserted-by":"crossref","unstructured":"Mej\u00eda-Mej\u00eda E Allen J Budidha K El-Hajj C Kyriacou PA Charlton PH . Photoplethysmography signal processing and synthesis. In: Kyriacou PA Budidha K , editors. Photoplethysmography: Technology, Signal Analysis, and Applications. Academic Press; 2021:139-175.","DOI":"10.1016\/B978-0-12-823374-0.00015-3"},{"issue":"3","key":"R34","doi-asserted-by":"publisher","first-page":"R1","DOI":"10.1088\/0967-3334\/28\/3\/R01","article-title":"Photoplethysmography and its application in clinical physiological measurement","volume":"28","author":"Allen","journal-title":"Physiol Meas"},{"issue":"2","key":"R35","doi-asserted-by":"publisher","first-page":"522","DOI":"10.1109\/TBME.2014.2359372","article-title":"TROIKA: a general framework for heart rate monitoring using wrist-type photoplethysmographic signals during intensive physical exercise","volume":"62","author":"Zhang","journal-title":"IEEE Trans Biomed Eng"},{"issue":"5","key":"R36","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1093\/ehjdh\/ztae042","article-title":"Standardized assessment of evidence supporting the adoption of mobile health solutions: a clinical consensus statement of the ESC Regulatory Affairs Committee","volume":"5","author":"Caiani","journal-title":"Eur Heart J Digit Health"}],"container-title":["JMIR Cardio"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/cardio.jmir.org\/2025\/1\/e69343","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T17:56:58Z","timestamp":1782842218000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardio.jmir.org\/2025\/1\/e69343"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,30]]},"references-count":36,"URL":"https:\/\/doi.org\/10.2196\/69343","relation":{},"ISSN":["2561-1011"],"issn-type":[{"value":"2561-1011","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,30]]},"article-number":"v9i10e69343"}}