{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T19:00:02Z","timestamp":1782846002527,"version":"3.54.5"},"reference-count":27,"publisher":"JMIR Publications Inc.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JMIR Form Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec sec-type=\"background\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The risk of developing heat-related illness increases when personal protective equipment (PPE) is worn, especially in hot and humid environments. While cooling strategies are effective, they must be applied preemptively or delivered promptly, which can be difficult if individuals are working in dangerous environments or wearing contaminated PPE. Wearable sensors can be leveraged to continuously monitor health including heart rate, respiration rate, blood oxygen levels, and physical activity.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"objective\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This study aims to (1) evaluate the use of wearable sensors for monitoring the real-time health of individuals wearing PPE to mitigate the risk of developing a heat-related illness and enable timely intervention, (2) understand how PPE may affect smartwatch data quality and comfort, and (3) identify circumstances in which people wearing PPE may not be able to wear a smartwatch.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Individuals participating in planned field trainings or exercises where PPE was being worn were asked to wear Garmin Fenix 6 smartwatch (Garmin Ltd) before, during, and after the event to monitor health and recovery. These convenience cohorts were selected to understand the feasibility of using smartwatches with different types of PPE (ie, level C PPE and firefighter gear) for different types of training (ie, a simulated environmental cleanup exercise and skill and tactical maneuver training for new firefighter recruits).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Two data collections were conducted using the Garmin Fenix 6 smartwatch to assess wearability, data quality, and data accuracy. For the first effort, participants wore the watch for 3.9\u20105.1 days, and wear compliance ranged from 83.8% to 99.9%. For the second effort, participants wore the watch for the exercise only, which was 3.5 hours. Participants were able to wear the watches for the entire time that they were wearing PPE and did not report any adverse events. Changes in heart rate corresponded with changes in physical activity, providing evidence that physiology can be acceptably monitored during physical activity. Heart rate data artifact ranged between 5.8% and 9.3% and was highest for the control participant (second data collection) who was not wearing PPE.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"conclusions\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Based on the results obtained from the 8 pilot users, the Garmin Fenix 6 smartwatch is an appropriate choice for continuously monitoring the health of individuals wearing PPE. The watch can be tolerated for extended wear periods and data quality is sufficient for monitoring heart rate and predicting core body temperature.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2196\/72324","type":"journal-article","created":{"date-parts":[[2025,7,6]],"date-time":"2025-07-06T02:30:07Z","timestamp":1751769007000},"page":"e72324-e72324","source":"Crossref","is-referenced-by-count":2,"title":["Predicting Risk of Heat-Related Injuries for Individuals Wearing Personal Protective Equipment Using Smartwatches: Feasibility Observational Study"],"prefix":"10.2196","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0919-6906","authenticated-orcid":false,"given":"Meghan","family":"Hegarty-Craver","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9500-0975","authenticated-orcid":false,"given":"Donna","family":"Womack","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6740-2149","authenticated-orcid":false,"given":"Jonathan","family":"Thornburg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3715-7784","authenticated-orcid":false,"given":"Timothy","family":"Boe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0455-7204","authenticated-orcid":false,"given":"M John","family":"Archer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6544-329X","authenticated-orcid":false,"given":"Worth","family":"Calfee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1010","published-online":{"date-parts":[[2025,10,17]]},"reference":[{"issue":"3","key":"R1","doi-asserted-by":"publisher","DOI":"10.3390\/ijerph19031905","article-title":"Heat strain and use of heat mitigation strategies among COVID-19 healthcare workers wearing personal protective equipment-a retrospective study","volume":"19","author":"Bongers","journal-title":"Int J Environ Res Public Health"},{"issue":"19","key":"R2","doi-asserted-by":"publisher","DOI":"10.3390\/ijerph191912288","article-title":"Perceptions of heat stress, heat strain and mitigation practices in wildfire suppression across Southern Europe and Latin America","volume":"19","author":"Carballo-Leyenda","journal-title":"Int J Environ Res Public Health"},{"issue":"11-12","key":"R3","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1080\/15459624.2020.1834112","article-title":"Influence of age, geographical region, and work unit on heat strain symptoms: a cross-sectional survey of electrical utility workers","volume":"17","author":"Rogerson","journal-title":"J Occup Environ Hyg"},{"key":"R4","unstructured":"Occupational Safety and Health Administration. OSHA technical manual (OTM). section III: chapter 4: heat stress. US Department of Labor. 2017. URL: https:\/\/www.osha.gov\/otm\/section-3-health-hazards\/chapter-4 [Accessed 12-09-2025]"},{"issue":"2","key":"R5","doi-asserted-by":"publisher","first-page":"91","DOI":"10.2486\/indhealth.2018-0205","article-title":"A novel vest with dual functions for firefighters: combined effects of body cooling and cold fluid ingestion on the alleviation of heat strain","volume":"58","author":"Kim","journal-title":"Ind Health"},{"issue":"3","key":"R6","doi-asserted-by":"publisher","first-page":"370","DOI":"10.2486\/indhealth.2018-0063","article-title":"Frequency of firefighters\u2019 heat-related illness and its association with removing personal protective equipment and working hours","volume":"57","author":"Kim","journal-title":"Ind Health"},{"issue":"9","key":"R7","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1139\/apnm-2018-0173","article-title":"On the use of wearable physiological monitors to assess heat strain during occupational heat stress","volume":"43","author":"Notley","journal-title":"Appl Physiol Nutr Metab"},{"issue":"2","key":"R8","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1016\/S0003-4878(00)00030-2","article-title":"Development and validation of the predicted heat strain model","volume":"45","author":"Malchaire","journal-title":"Ann Occup Hyg"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtherbio.2017.01.003","article-title":"Mathematical prediction of core body temperature from environment, activity, and clothing: The heat strain decision aid (HSDA)","volume":"64","author":"Potter","journal-title":"J Therm Biol"},{"key":"R10","doi-asserted-by":"crossref","unstructured":"Vogt JJ Candas V Libert JP Daull F . Chapter 6: required sweat rate as an index of thermal strain in industry. In: Studies in Environmental Science. 1981:99-110. [doi: 10.1016\/S0166-1116(08)71083-5]","DOI":"10.1016\/S0166-1116(08)71083-5"},{"issue":"10","key":"R11","doi-asserted-by":"publisher","first-page":"831","DOI":"10.2519\/jospt.2014.5500","article-title":"Heat stress and thermal strain challenges in running","volume":"44","author":"Bergeron","journal-title":"J Orthop Sports Phys Ther"},{"issue":"4","key":"R12","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1016\/s0022-3476(98)70067-8","article-title":"Comparison of esophageal, rectal, axillary, bladder, tympanic, and pulmonary artery temperatures in children","volume":"133","author":"Robinson","journal-title":"J Pediatr"},{"key":"R13","doi-asserted-by":"crossref","unstructured":"Murdock R Hagen J . Soldier safety and performance through wearable devices. Presented at: Micro- and Nanotechnology Sensors, Systems, and Applications X; Apr 15-19, 2018; Orlando, FL, United States. [doi: 10.1117\/12.2304899]","DOI":"10.1117\/12.2304899"},{"issue":"7","key":"R14","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1088\/0967-3334\/34\/7\/781","article-title":"Estimation of human core temperature from sequential heart rate observations","volume":"34","author":"Buller","journal-title":"Physiol Meas"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2018.05.021","article-title":"Estimation of core body temperature from skin temperature, heat flux, and heart rate using a Kalman filter","volume":"99","author":"Welles","journal-title":"Comput Biol Med"},{"issue":"1","key":"R16","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-020-0226-6","article-title":"Investigating sources of inaccuracy in wearable optical heart rate sensors","volume":"3","author":"Bent","journal-title":"NPJ Digit Med"},{"key":"R17","unstructured":"Personal protective equipment. Environmental Protection Agency. 2022. URL: https:\/\/www.epa.gov\/emergency-response\/personal-protective-equipment [Accessed 26-02-2023]"},{"key":"R18","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtherbio.2014.08.009","article-title":"Seasonal heat acclimatization in wildland firefighters","volume":"45","author":"Lui","journal-title":"J Therm Biol"},{"key":"R19","unstructured":"WRAP. URL: https:\/\/www.gowrap.org [Accessed 25-01-2023]"},{"issue":"2","key":"R20","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1152\/japplphysiol.00374.2018","article-title":"Step frequency patterns of elite ultramarathon runners during a 100-km road race","volume":"126","author":"Burns","journal-title":"J Appl Physiol (1985)"},{"issue":"21","key":"R21","doi-asserted-by":"publisher","DOI":"10.3390\/s20216396","article-title":"The importance of respiratory rate monitoring: from healthcare to sport and exercise","volume":"20","author":"Nicol\u00f2","journal-title":"Sensors (Basel)"},{"issue":"3","key":"R22","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1097\/ALN.0000000000002002","article-title":"Four types of pulse oximeters accurately detect hypoxia during low perfusion and motion","volume":"128","author":"Louie","journal-title":"Anesthesiology"},{"key":"R23","unstructured":"Champseix R . hrvanalysis. URL: https:\/\/aura-healthcare.github.io\/hrv-analysis\/ [Accessed 11-10-2025]"},{"key":"R24","doi-asserted-by":"publisher","DOI":"10.1016\/j.envint.2019.05.026","article-title":"Evaluation of wearable sensors for physiologic monitoring of individually experienced temperatures in outdoor workers in southeastern U.S","volume":"129","author":"Runkle","journal-title":"Environ Int"},{"issue":"2","key":"R25","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1152\/japplphysiol.00266.2021","article-title":"Sex differences in the physiological responses to exercise-induced dehydration: consequences and mechanisms","volume":"131","author":"Wickham","journal-title":"J Appl Physiol (1985)"},{"issue":"3","key":"R26","doi-asserted-by":"publisher","first-page":"e327","DOI":"10.1097\/CCM.0000000000004807","article-title":"The relationship between heart rate and body temperature in critically ill patients","volume":"49","author":"Broman","journal-title":"Crit Care Med"},{"issue":"Suppl 1","key":"R27","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1186\/cc8561","article-title":"A comparison of core and tympanic temperature measurement in the critically ill","volume":"14","author":"Sanderson","journal-title":"Crit Care"}],"container-title":["JMIR Formative Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/formative.jmir.org\/2025\/1\/e72324","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T18:02:36Z","timestamp":1782842556000},"score":1,"resource":{"primary":{"URL":"https:\/\/formative.jmir.org\/2025\/1\/e72324"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,17]]},"references-count":27,"URL":"https:\/\/doi.org\/10.2196\/72324","relation":{},"ISSN":["2561-326X"],"issn-type":[{"value":"2561-326X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,17]]},"article-number":"v9i3e72324"}}