{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T17:28:29Z","timestamp":1793726909159,"version":"4.6.1"},"reference-count":29,"publisher":"JMIR Publications Inc.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JMIR Mhealth Uhealth"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec sec-type=\"background\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Diabetic foot ulcers (DFUs) are a life-changing complication of diabetes. There is increasing evidence that remote plantar temperature monitoring can reduce the recurrence of DFUs. Monitoring of foot temperature once a day is the current guideline for identifying early signs of foot inflammation. However, single readings of physiological signals can increase the risk of misdiagnosis when the signals fluctuate throughout the day.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"objective\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>The aim of this study was to evaluate whether intraday temperature asymmetry signals were stable or varied as a function of time in individuals at risk of DFUs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In total, 64 participants with diabetes (mean age 68, SD 13.8 y) were provided with multimodal sensory insoles (Orpyx Sensory Insoles) to monitor continuous temperature data at a frequency of once per minute at 5 plantar locations in a 90-day study window. The augmented Dickey-Fuller test was used to determine whether the temperature asymmetry signals were stationary (ie, indicating constant mean and variance over time) or nonstationary (ie, indicating time-varying behaviors or trends in the signal).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The study included 43 participants, 1080 data days, and 5400 contralateral temperature asymmetry signals. Most (4428\/5400, 82%) of the temperature asymmetry signals were nonstationary, with intraday fluctuations likely influenced by physiological and environmental factors. Of the nonstationary signals, nearly half (1948\/4428, 44%) fluctuated above and below the concerning asymmetry threshold of 2.2 \u00b0C. The intraday variability underscores the potential for false-positive and false-negative hot spot detection with once-daily measurements. Substantial variability was observed in stationarity patterns both within and across participants. Notably, concerning asymmetries in nonstationary signals occurred at different time points across participants, measurement windows, and days.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"conclusions\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Our findings highlight the value of continuous plantar temperature monitoring for diabetic foot health management, relative to once-daily measurements. Several repeated measurements throughout the day increase confidence with regard to the accuracy of observed plantar physiology trends. Continuous monitoring may improve the accuracy of plantar temperature measurement, unlock new diagnostic capabilities, and support personalized care.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2196\/73187","type":"journal-article","created":{"date-parts":[[2025,7,21]],"date-time":"2025-07-21T23:10:06Z","timestamp":1753139406000},"page":"e73187-e73187","source":"Crossref","is-referenced-by-count":5,"title":["Exploring the Value of Continuous Plantar Temperature Monitoring for Diabetic Foot Health Management: Observational, Prospective Cohort Study"],"prefix":"10.2196","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1424-499X","authenticated-orcid":false,"given":"Maryam","family":"Hajizadeh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1956-0107","authenticated-orcid":false,"given":"Emily","family":"Matijevich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-2183-1414","authenticated-orcid":false,"given":"Emily","family":"Bray","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4631-9992","authenticated-orcid":false,"given":"Evan","family":"Minty","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-6023-2582","authenticated-orcid":false,"given":"Brock","family":"Liden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1010","published-online":{"date-parts":[[2025,9,12]]},"reference":[{"issue":"1","key":"R1","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1001\/jama.2023.10578","article-title":"Diabetic foot ulcers: a review","volume":"330","author":"Armstrong","journal-title":"JAMA"},{"issue":"24","key":"R2","doi-asserted-by":"publisher","first-page":"2367","DOI":"10.1056\/NEJMra1615439","article-title":"Diabetic foot ulcers and their recurrence","volume":"376","author":"Armstrong","journal-title":"N Engl J Med"},{"key":"R3","doi-asserted-by":"publisher","DOI":"10.1002\/dmrr.3269","article-title":"Guidelines on the prevention of foot ulcers in persons with diabetes (IWGDF 2019 update)","volume":"36 Suppl 1","author":"Bus","journal-title":"Diabetes Metab Res Rev"},{"issue":"1","key":"R4","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1093\/ptj\/59.1.18","article-title":"Temperature assessment of the insensitive foot","volume":"59","author":"Bergtholdt","journal-title":"Phys Ther"},{"issue":"6","key":"R5","doi-asserted-by":"publisher","DOI":"10.1002\/dmrr.3549","article-title":"Efficacy of at home monitoring of foot temperature for risk reduction of diabetes-related foot ulcer: a meta-analysis","volume":"38","author":"Golledge","journal-title":"Diabetes Metab Res Rev"},{"issue":"1","key":"R6","doi-asserted-by":"publisher","DOI":"10.15761\/WCM.1000102","article-title":"Cost effectiveness of smart insoles in preventing ulcer recurrence for people in diabetic foot remission","volume":"1","author":"Najafi","journal-title":"Wound Care Manage"},{"issue":"7","key":"R7","doi-asserted-by":"publisher","first-page":"973","DOI":"10.2337\/dc16-2294","article-title":"Feasibility and efficacy of a smart mat technology to predict development of diabetic plantar ulcers","volume":"40","author":"Frykberg","journal-title":"Diabetes Care"},{"issue":"12","key":"R8","doi-asserted-by":"publisher","DOI":"10.2196\/12460","article-title":"Continuous temperature-monitoring socks for home use in patients with diabetes: observational study","volume":"20","author":"Reyzelman","journal-title":"J Med Internet Res"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1016\/j.diabres.2020.108074","article-title":"Accuracy of a foot temperature monitoring mat for predicting diabetic foot ulcers in patients with recent wounds or partial foot amputation","volume":"161","author":"Gordon","journal-title":"Diabetes Res Clin Pract"},{"issue":"2","key":"R10","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1093\/ptj\/77.2.169","article-title":"Infrared dermal thermometry for the high-risk diabetic foot","volume":"77","author":"Armstrong","journal-title":"Phys Ther"},{"issue":"11","key":"R11","doi-asserted-by":"publisher","first-page":"714","DOI":"10.1089\/dia.2014.0052","article-title":"Diagnostic values for skin temperature assessment to detect diabetes-related foot complications","volume":"16","author":"van Netten","journal-title":"Diabetes Technol Ther"},{"issue":"5","key":"R12","doi-asserted-by":"publisher","DOI":"10.3390\/s21051717","article-title":"Monitoring of dynamic plantar foot temperatures in diabetes with personalised 3D-printed wearables","volume":"21","author":"Beach","journal-title":"Sensors (Basel)"},{"issue":"12","key":"R13","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics12122964","article-title":"Artificial intelligence, wearables and remote monitoring for heart failure: current and future applications","volume":"12","author":"Gautam","journal-title":"Diagnostics (Basel)"},{"issue":"20","key":"R14","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.118.008658","article-title":"Number of measurements needed to obtain a reliable estimate of home blood pressure: results from the improving the detection of hypertension study","volume":"7","author":"Bello","journal-title":"J Am Heart Assoc"},{"key":"R15","doi-asserted-by":"crossref","unstructured":"Mendez M Bianchi AM Villantieri O Cerutti S . Time-varying analysis of the heart rate variability during REM and non REM sleep stages. Presented at: 2006 International Conference of the IEEE Engineering in Medicine and Biology Society; Aug 30 to Sep 3, 2006:3576-3579; New York, NY. [doi: 10.1109\/IEMBS.2006.260067]","DOI":"10.1109\/IEMBS.2006.260067"},{"issue":"Suppl 2","key":"R16","doi-asserted-by":"publisher","first-page":"S3","DOI":"10.1089\/dia.2015.0417","article-title":"Continuous glucose monitoring: a review of successes, challenges, and opportunities","volume":"18 Suppl 2","author":"Rodbard","journal-title":"Diabetes Technol Ther"},{"issue":"5","key":"R17","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1089\/dia.2020.0524","article-title":"The ambulatory glucose profile: opportunities for enhancement","volume":"23","author":"Rodbard","journal-title":"Diabetes Technol Ther"},{"key":"R18","doi-asserted-by":"publisher","DOI":"10.1109\/JTEHM.2021.3098127","article-title":"A novel wearable device for continuous temperature monitoring & fever detection","volume":"9","author":"Verma","journal-title":"IEEE J Transl Eng Health Med"},{"issue":"2","key":"R19","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1177\/0309364620968642","article-title":"A walking bout reveals altered foot thermodynamics associated with unilateral transtibial amputation among individuals with type 2 diabetes","volume":"45","author":"Leister","journal-title":"Prosthetics & Orthotics International"},{"issue":"6","key":"R20","doi-asserted-by":"publisher","first-page":"e308","DOI":"10.1016\/S2589-7500(19)30128-1","article-title":"Innovative intelligent insole system reduces diabetic foot ulcer recurrence at plantar sites: a prospective, randomised, proof-of-concept study","volume":"1","author":"Abbott","journal-title":"Lancet Digit Health"},{"issue":"9","key":"R21","doi-asserted-by":"publisher","DOI":"10.3390\/s24092675","article-title":"A multi-faceted digital health solution for monitoring and managing diabetic foot ulcer risk: a case series","volume":"24","author":"Matijevich","journal-title":"Sensors (Basel)"},{"issue":"1","key":"R22","doi-asserted-by":"publisher","DOI":"10.25080\/Majora-92bf1922-011","article-title":"Statsmodels: econometric and statistical modeling with Python","volume":"7","author":"Seabold","journal-title":"SciPy"},{"issue":"2","key":"R23","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1080\/07350015.1994.10510005","article-title":"Approximate asymptotic distribution functions for unit-root and cointegration tests","volume":"12","author":"MacKinnon","journal-title":"J Bus Econ Stat"},{"key":"R24","doi-asserted-by":"crossref","unstructured":"Mushtaq R . Augmented Dickey Fuller Test. SSRN J. Preprint posted online on Aug 17, 2011. [doi: 10.2139\/ssrn.1911068]","DOI":"10.2139\/ssrn.1911068"},{"issue":"5","key":"R25","doi-asserted-by":"publisher","DOI":"10.1002\/dmrr.3621","article-title":"Does the skin heat up before it breaks down in diabetic foot ulceration?","volume":"39","author":"aan de Stegge","journal-title":"Diabetes Metabolism Res"},{"key":"R26","doi-asserted-by":"publisher","DOI":"10.1177\/19322968241249970","article-title":"Infrared thermography shows that a temperature difference of 2.2\u00b0C (4\u00b0F) or greater between corresponding sites of neuropathic feet does not always lead to a diabetic foot ulcer","author":"Liew","journal-title":"J Diabetes Sci Technol"},{"key":"R27","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2016.12.008","article-title":"Walking cadence affects rate of plantar foot temperature change but not final temperature in younger and older adults","volume":"52","author":"Reddy","journal-title":"Gait Posture"},{"issue":"2","key":"R28","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1055\/a-0838-5209","article-title":"Thermographic characteristics of the diabetic foot with peripheral arterial disease using the angiosome concept","volume":"129","author":"Carabott","journal-title":"Exp Clin Endocrinol Diabetes"},{"issue":"4","key":"R29","doi-asserted-by":"publisher","first-page":"550","DOI":"10.2337\/cd23-0092","article-title":"Unleashing the potential of blood glucose monitoring data with the Ambulatory Glucose Profile Report","volume":"42","author":"Simonson","journal-title":"Clin Diabetes"}],"container-title":["JMIR mHealth and uHealth"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/mhealth.jmir.org\/2025\/1\/e73187","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T18:03:43Z","timestamp":1782842623000},"score":1,"resource":{"primary":{"URL":"https:\/\/mhealth.jmir.org\/2025\/1\/e73187"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,12]]},"references-count":29,"URL":"https:\/\/doi.org\/10.2196\/73187","relation":{},"ISSN":["2291-5222"],"issn-type":[{"value":"2291-5222","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,12]]},"article-number":"v13i1e73187"}}