{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T22:07:20Z","timestamp":1788905240553,"version":"build-2803163510"},"reference-count":30,"publisher":"JMIR Publications Inc.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JMIR Res Protoc"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec sec-type=\"background\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Stainless steel (SS) orthodontic archwires are widely used because of their mechanical properties, affordability, and biocompatibility; yet, prolonged intraoral exposure can cause electrochemical corrosion and release of metal ions (eg, Ni and Cr) that may affect clinical performance and patient safety. Surface coatings such as silver dioxide have been proposed to improve corrosion resistance, but comparative data for silver dioxide\u2013coated versus uncoated SS orthodontic archwires across clinically relevant simulated oral environments are lacking.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"objective\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This study aimed to compare the corrosion susceptibility of silver dioxide\u2013coated and noncoated 0.019\u201c\u00d70.025\u201d SS orthodontic archwires in four simulated oral solutions by measuring electrochemical behavior, cumulative metal ion release, and mass lossthereby testing our null hypothesis (H\u2080) that no difference exists between coated and noncoated wires.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This in vitro protocol uses 40 SS archwire specimens divided into two main groups (20 silver dioxide\u2013coated, and 20 uncoated) and four immersion subgroups (n=5 per subgroup): (1) 0.9% NaCl, (2) phosphate-buffered solution acidified with lactic acid (pH ~6.75), (3) phosphate-buffered solution with 0.1 wt% NaF, and (4) phosphate-buffered solution with 0.1% w\/v bovine serum albumin. Coatings will be deposited by radiofrequency magnetron sputtering to achieve a 15\u2010 to 20-nm silver oxide (Ag\u2082O\/AgO) layer; coating quality will be verified through scanning electron microscopy (SEM), energy-dispersive x-ray spectroscopy (EDS), and profilometry. Specimens will be incubated individually at 37 \u00b0C with orbital agitation; immersion solutions will be sampled at baseline, 14 days, and 28 days. The primary outcome is corrosion current density (Icorr, \u00b5A\/cm\u00b2) from potentiodynamic polarization. Secondary outcomes include pitting potential (Epit, mV vs SCE), cumulative ion release (Ag, Ni, Cr, Fe; expressed \u00b5g\/mm\u00b2) analyzed by inductively coupled plasma\u2013optical emission spectrometry (ICP-OES) after acidification, percent weight loss normalized to surface area (mg\/cm\u00b2), and SEM\/EDS surface analyses. Electrochemical tests will follow a standardized three-electrode setup (SCE reference). Statistical analyses will be used to assess normality; we will use independent-samples tests or nonparametric equivalents for between-group comparisons and mixed-effects models for time-dependent measures. Tests were evaluated at \u03b1=.05, with effect sizes and 95% CIs reported throughout.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Institutional ethical approval was obtained in April 2024 (DMIHER(DU)\/IEC\/2024\/253). Coating parameters and quality control procedures have been established, and 40 specimens have been prepared and characterized. Immersion and electrochemical experiments are scheduled between June and December 2025, followed by ICP-OES analysis and statistical evaluation, with study completion planned by December 2025.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"conclusions\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>This protocol will generate comparative data on electrochemical corrosion, ion release, and material degradation of silver dioxide\u2013coated versus uncoated SS orthodontic archwires under multiple simulated oral conditions. Our findings will inform the potential of silver dioxide coatings to enhance the durability and biocompatibility of orthodontic archwires and will guide future in vivo or clinical investigations.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2196\/74309","type":"journal-article","created":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T19:05:09Z","timestamp":1767035109000},"page":"e74309-e74309","source":"Crossref","is-referenced-by-count":0,"title":["Comparative Evaluation of Silver Dioxide\u2013Coated and Noncoated Stainless Steel Wires for Susceptibility to Corrosion: Protocol for an In Vitro Study"],"prefix":"10.2196","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-3464-3633","authenticated-orcid":false,"given":"Aishwarya","family":"Atey","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5601-8443","authenticated-orcid":false,"given":"Rizwan","family":"Gilani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1811-9179","authenticated-orcid":false,"given":"Shefali","family":"Singh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-7658-5119","authenticated-orcid":false,"given":"Abhijeet","family":"Kadam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1010","published-online":{"date-parts":[[2026,9,8]]},"reference":[{"issue":"1","key":"R1","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1007\/s10439-013-0885-4","article-title":"Susceptibility to corrosion and in vitro biocompatibility of a laser-welded composite orthodontic arch wire","volume":"42","author":"Zhang","journal-title":"Ann Biomed Eng"},{"issue":"1","key":"R2","first-page":"12","volume":"7","author":"Gopikrishnan","journal-title":"J Int Oral Health"},{"issue":"4","key":"R3","doi-asserted-by":"publisher","first-page":"429","DOI":"10.17796\/jcpd.35.4.m17j2h5827861m55","article-title":"Comparison of some dietary habits on corrosion behavior of stainless steel brackets: An in vitro study","volume":"35","author":"Shahabi","journal-title":"J Clin Pediatr Dent"},{"issue":"1","key":"R4","doi-asserted-by":"publisher","first-page":"9","DOI":"10.4103\/0301-5742.199245","article-title":"Antibacterial and antiadherent properties of silver dioxide-coated brackets","volume":"51","author":"Gilani","journal-title":"J Indian Orthod Soc"},{"issue":"7","key":"R5","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1016\/j.dental.2011.03.009","article-title":"Comparative study on corrosion resistance and in vitro biocompatibility of bulk nanocrystalline and microcrystalline biomedical 304 stainless steel","volume":"27","author":"Nie","journal-title":"Dent Mater"},{"issue":"1","key":"R6","first-page":"13","volume":"19","author":"Shin","journal-title":"Aust Orthod J"},{"issue":"4","key":"R7","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1002\/jbm.a.30340","article-title":"Surface characterizations and corrosion resistance of nickel-titanium orthodontic archwires in artificial saliva of various degrees of acidity","volume":"74","author":"Huang","journal-title":"J Biomed Mater Res A"},{"issue":"3","key":"R8","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1043\/0003-3219(2002)072<0222:IVAOOA>2.0.CO;2","article-title":"In vivo aging of orthodontic alloys: implications for corrosion potential, nickel release, and biocompatibility","volume":"72","author":"Eliades","journal-title":"Angle Orthod"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1043\/0003-3219(1999)0692.3.CO;2","article-title":"Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires","volume":"69","author":"Kim","journal-title":"Angle Orthod"},{"issue":"1","key":"R10","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.ajodo.2006.12.018","article-title":"Nickel concentration in the saliva of patients with nickel-titanium orthodontic appliances","volume":"135","author":"Petoumenou","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"1","key":"R11","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1016\/0889-5406(93)70098-9","article-title":"Biodegradation of orthodontic appliances. Part I. Biodegradation of nickel and chromium in vitro","volume":"103","author":"Barrett","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"6","key":"R12","doi-asserted-by":"publisher","first-page":"409","DOI":"10.3109\/00016358709096365","article-title":"Metal release from heat-treated orthodontic archwires","volume":"45","author":"Gjerdet","journal-title":"Acta Odontol Scand"},{"issue":"2","key":"R13","doi-asserted-by":"publisher","first-page":"355","DOI":"10.2319\/0003-3219(2007)077[0355:GCOMIM]2.0.CO;2","article-title":"Galvanic corrosion of metal injection molded (MIM) and conventional brackets with nickel-titanium and copper-nickel-titanium archwires","volume":"77","author":"Siargos","journal-title":"Angle Orthod"},{"issue":"1","key":"R14","first-page":"16","volume":"29","author":"Matasa","journal-title":"J Clin Orthod"},{"issue":"2","key":"R15","doi-asserted-by":"publisher","first-page":"275","DOI":"10.4103\/0970-9290.66648","article-title":"An overview of orthodontic material degradation in oral cavity","volume":"21","author":"Chaturvedi","journal-title":"Indian J Dent Res"},{"issue":"6","key":"R16","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1016\/s0300-5712(98)00073-6","article-title":"Ion release from orthodontic appliances","volume":"27","author":"Staffolani","journal-title":"J Dent"},{"issue":"1","key":"R17","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1051\/orthodfr\/200374115","volume":"74","author":"Grosgogeat","journal-title":"Orthod Fr"},{"issue":"8","key":"R18","doi-asserted-by":"publisher","first-page":"6919","DOI":"10.3390\/ijms24086919","article-title":"Functional surface coatings on orthodontic appliances: Reviews of friction reduction, antibacterial properties, and corrosion resistance","volume":"24","author":"Zhang","journal-title":"IJMS"},{"issue":"1","key":"R19","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/coatings3010001","article-title":"Coating and surface treatments on orthodontic metallic materials","volume":"3","author":"Arango","journal-title":"Coatings"},{"issue":"4","key":"R20","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1016\/j.ajodo.2007.03.021","article-title":"Corrosion of orthodontic appliances\u2014should we care?","volume":"133","author":"House","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"R21","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtemb.2015.05.001","article-title":"In vivo determination of aluminum, cobalt, chromium, copper, nickel, titanium and vanadium in oral mucosa cells from orthodontic patients with mini-implants by Inductively coupled plasma-mass spectrometry (ICP-MS)","volume":"32","author":"Mart\u00edn-Came\u00e1n","journal-title":"J Trace Elem Med Biol"},{"issue":"2","key":"R22","doi-asserted-by":"publisher","first-page":"190","DOI":"10.3390\/coatings12020190","article-title":"Differences in metal ions released from orthodontic appliances in an in vitro and in vivo setting","volume":"12","author":"Kovac","journal-title":"Coatings"},{"issue":"2","key":"R23","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1093\/ortho\/30.2.171","article-title":"Nickel allergy and orthodontics","volume":"30","author":"Rahilly","journal-title":"J Orthod"},{"issue":"6","key":"R24","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1038\/bdj.2008.198","article-title":"Nickel allergy and orthodontics, a review and report of two cases","volume":"204","author":"Noble","journal-title":"Br Dent J"},{"issue":"5","key":"R25","doi-asserted-by":"publisher","first-page":"9745","DOI":"10.3390\/nano9050753","article-title":"Application of a molybdenum and tungsten disulfide coating to improve tribological properties of orthodontic archwires","volume":"9","author":"Gracco","journal-title":"Nanomaterials (Basel)"},{"issue":"2","key":"R26","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/j.jds.2017.07.003","article-title":"Mechanical and frictional properties of aesthetic orthodontic wires obtained by hard chrome carbide plating","volume":"13","author":"Usui","journal-title":"J Dent Sci"},{"issue":"2","key":"R27","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1016\/j.ortho.2021.01.009","article-title":"Comparative evaluation of stainless-steel wires and brackets coated with nanoparticles of chitosan or zinc oxide upon friction: An in vitro study","volume":"19","author":"Elhelbawy","journal-title":"Int Orthod"},{"key":"R28","doi-asserted-by":"publisher","DOI":"10.1155\/2021\/6651289","article-title":"Evaluating the mechanical properties of zinc-coated stainless steel orthodontic wires using physical vapor deposition","volume":"2021","author":"Karandish","journal-title":"Int J Dent"},{"issue":"2","key":"R29","doi-asserted-by":"publisher","first-page":"286","DOI":"10.4012\/dmj.2016-348","article-title":"Corrosion resistance and mechanical properties of titanium nitride plating on orthodontic wires","volume":"37","author":"Sugisawa","journal-title":"Dent Mater J"},{"issue":"4","key":"R30","doi-asserted-by":"publisher","first-page":"1913","DOI":"10.1016\/j.actbio.2010.11.026","article-title":"Development and evaluation of two PVD-coated \u03b2-titanium orthodontic archwires for fluoride-induced corrosion protection","volume":"7","author":"Krishnan","journal-title":"Acta Biomater"}],"container-title":["JMIR Research Protocols"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T21:11:02Z","timestamp":1788901862000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.researchprotocols.org\/2026\/1\/e74309"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,8]]},"references-count":30,"URL":"https:\/\/doi.org\/10.2196\/74309","relation":{},"ISSN":["1929-0748"],"issn-type":[{"value":"1929-0748","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,8]]},"article-number":"v15i1e74309"}}