{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T01:57:08Z","timestamp":1790128628620,"version":"4.0.1"},"reference-count":26,"publisher":"JMIR Publications Inc.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JMIR Res Protoc"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec sec-type=\"background\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Covered stents commercially available are frequently used off-label in conjunction with fenestrated and branched aortic stent grafts, but there is a lack of dedicated devices.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"objective\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>\n                      This study aims to assess the safety and mid-term clinical performance of a new dedicated covered stent, the GORE\n                      <jats:sup\/>\n                      VIABAHN\n                      <jats:sup\/>\n                      VBX Balloon Expandable Endoprosthesis (VBX stent graft), when used as a bridging stent with branched and fenestrated aortic endografts in treating complex abdominal aortic and thoraco-abdominal aneurysms.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A retrospective, multicenter, single-arm study in the European Union (ClinicalTrials.gov NCT05143138) enrolled patients treated with the VBX stent graft as a bridging stent in branched endovascular repair (BEVAR) and fenestrated endovascular repair (FEVAR) to allow endovascular aneurysm repair between January 2017 and December 2021. Up to 15 sites in Europe were required to enroll a minimum of 220 patients. Patients\u2019 medical records were reviewed by the investigator, and specific data were collected ambispectively for up to 5 years of follow-up from the index procedure. The primary end point is target vessel patency (patient level) through 12 months. The registry was designed to statistically test target vessel patency at 12 months in both FEVAR and BEVAR populations. The hypothesis will be tested separately in the 2 cohorts (fenestrated or branched endovascular repair), using patients with core laboratory imaging results available annually through 5 years. The binomial exact test will be used with a 1-sided 2.5% level of significance to test the null hypothesis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      In total, 259 patients were retrospectively enrolled for a prospective follow-up of 5 years: 136 patients (n=99, 72.8% male; mean age 73, SD 8.9 y) in the BEVAR cohort, 92 patients (n=80, 87.0% male, mean age 72.7, SD 8.1 y) in the FEVAR cohort, and 31 patients (n=17, 54.8% male, mean age 70.9, SD 9.4 y) in the mixed fenestrated or branched endovascular repair cohort. Overall, 662 target vessels were stented with the investigational covered stents: 163 (24.6%) celiac trunk, 192 (29.0%) superior mesenteric artery, and 307 (46.4%) renal arteries. The VBX stent grafts were paired with branches in 451 (68.1%) cases or fenestrations in 211 (31.9%) cases among all Cook Medical stent graft cases. The 1-year results will be published in the fourth quarter of\n                      <jats:sub\/>\n                      2025, and the 5-year follow-up results will be analyzed by mid-year 2028.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"conclusions\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>This study will investigate the VBX stent graft performance in combination with fenestrated and branched aortic grafts to corroborate its use in complex aortic endovascular procedures and support the modification of current device instructions for use.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2196\/78970","type":"journal-article","created":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T18:45:08Z","timestamp":1767033908000},"page":"e78970-e78970","source":"Crossref","is-referenced-by-count":3,"title":["GORE VIABAHN VBX Balloon-Expandable Endoprostheses as a Bridging Stent With Branched and Fenestrated Endografts in the Endovascular Treatment of Aortic Aneurysms: Protocol for a Retrospective Multicenter Registry (EMBRACE Study)"],"prefix":"10.2196","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-3053-8384","authenticated-orcid":false,"given":"Pietro","family":"Dioni","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3273-8726","authenticated-orcid":false,"given":"Anders","family":"Wanhainen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6181-6391","authenticated-orcid":false,"given":"Jacob","family":"Budtz-Lilly","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6907-6148","authenticated-orcid":false,"given":"Nuno","family":"Dias","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-5628-9475","authenticated-orcid":false,"given":"Tab","family":"Bonny","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6871-2176","authenticated-orcid":false,"given":"Luca","family":"Bertoglio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"EMBRACE study investigator","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1010","published-online":{"date-parts":[[2026,2,27]]},"reference":[{"issue":"1","key":"R1","doi-asserted-by":"publisher","first-page":"4S","DOI":"10.1016\/j.jvs.2020.06.011","article-title":"Reporting standards for endovascular aortic repair of aneurysms involving the renal-mesenteric arteries","volume":"73","author":"Oderich","journal-title":"J Vasc Surg"},{"issue":"4","key":"R2","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1016\/j.ejvs.2019.10.003","article-title":"Elective multistaged endovascular repair of thoraco-abdominal aneurysms with fenestrated and branched endografts to mitigate spinal cord ischaemia","volume":"59","author":"Bertoglio","journal-title":"Eur J Vasc Endovasc Surg"},{"issue":"4","key":"R3","doi-asserted-by":"publisher","first-page":"e893","DOI":"10.1097\/SLA.0000000000005859","article-title":"Mid-term renal and mesenteric artery outcomes during fenestrated and branched endovascular aortic repair for complex abdominal and thoracoabdominal aortic aneurysms in the United States aortic research consortium","volume":"278","author":"Tenorio","journal-title":"Ann Surg"},{"issue":"36","key":"R4","doi-asserted-by":"publisher","first-page":"3538","DOI":"10.1093\/eurheartj\/ehae179","article-title":"2024 ESC Guidelines for the management of peripheral arterial and aortic diseases","volume":"45","author":"Mazzolai","journal-title":"Eur Heart J"},{"issue":"4","key":"R5","doi-asserted-by":"publisher","first-page":"854","DOI":"10.1016\/j.jvs.2023.05.053","article-title":"Multicenter trans-Atlantic experience with fenestrated-branched endovascular aortic repair of chronic post-dissection thoracoabdominal aortic aneurysms","volume":"78","author":"Abdelhalim","journal-title":"J Vasc Surg"},{"issue":"2","key":"R6","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1177\/1526602817752449","article-title":"Preliminary outcomes of the LifeStream balloon-expandable covered stent in fenestrated and branched thoracoabdominal endovascular repairs","volume":"25","author":"Bertoglio","journal-title":"J Endovasc Ther"},{"key":"R7","unstructured":"International ethical guidelines for health-related research involving humans. Council for International Organizations of Medical Sciences (CIOMS); 2016. URL: https:\/\/cioms.ch\/wp-content\/uploads\/2017\/01\/WEB-CIOMS-EthicalGuidelines.pdf [Accessed 29-01-2026]"},{"issue":"2","key":"R8","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1016\/j.ejvs.2016.03.018","article-title":"Mid-term outcomes of renal branches versus renal fenestrations for thoraco-abdominal aneurysm repair","volume":"52","author":"Martin-Gonzalez","journal-title":"Eur J Vasc Endovasc Surg"},{"issue":"3","key":"R9","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1177\/1526602819842569","article-title":"In vitro evaluation of the Gore Viabahn balloon-expandable stent-graft for fenestrated endovascular aortic repair","volume":"26","author":"Torsello","journal-title":"J Endovasc Ther"},{"issue":"3","key":"R10","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1177\/1526602821996724","article-title":"Fatigue resistance of the Advanta V12\/iCast and Viabahn balloon-expandable stent-graft as bridging stents in experimental fenestrated endografting","volume":"28","author":"Torsello","journal-title":"J Endovasc Ther"},{"key":"R11","doi-asserted-by":"publisher","DOI":"10.1177\/15266028241289291","article-title":"Comparison of biomechanical properties of the iCover and VBX stent grafts when used as bridge stents in fenestrated endografts: an in vitro study","author":"Blanco Amil","journal-title":"J Endovasc Ther"},{"issue":"3","key":"R12","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1177\/15266028221083458","article-title":"Meta-analysis of comparative studies between self- and balloon-expandable bridging stent grafts in branched endovascular aneurysm repair","volume":"30","author":"Nana","journal-title":"J Endovasc Ther"},{"issue":"6","key":"R13","doi-asserted-by":"publisher","first-page":"1598","DOI":"10.1016\/j.jvs.2023.02.007","article-title":"Midterm results on a new self-expandable covered stent combined with branched stent grafts: insights from a multicenter Italian registry","volume":"77","author":"Bertoglio","journal-title":"J Vasc Surg"},{"issue":"4","key":"R14","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1177\/15266028211010455","article-title":"Performance of the Gore VBX balloon expandable endoprosthesis as bridging stent-graft in branched endovascular aortic repair for thoracoabdominal aneurysms","volume":"28","author":"Torsello","journal-title":"J Endovasc Ther"},{"issue":"5","key":"R15","doi-asserted-by":"publisher","first-page":"1489","DOI":"10.1016\/j.jvs.2019.07.079","article-title":"Outcomes of directional branches using self-expandable or balloon-expandable stent grafts during endovascular repair of thoracoabdominal aortic aneurysms","volume":"71","author":"Tenorio","journal-title":"J Vasc Surg"},{"issue":"6","key":"R16","doi-asserted-by":"publisher","first-page":"910","DOI":"10.1016\/j.ejvs.2020.02.015","article-title":"Outcomes of small renal artery targets in patients treated by fenestrated-branched endovascular aortic repair","volume":"59","author":"K\u00e4rkk\u00e4inen","journal-title":"Eur J Vasc Endovasc Surg"},{"issue":"4","key":"R17","doi-asserted-by":"publisher","first-page":"926","DOI":"10.1016\/j.jvs.2012.09.071","article-title":"Durability of branches in branched and fenestrated endografts","volume":"57","author":"Mastracci","journal-title":"J Vasc Surg"},{"issue":"2","key":"R18","doi-asserted-by":"publisher","first-page":"396","DOI":"10.1016\/j.jvs.2020.12.093","article-title":"Respiratory-induced changes in renovisceral branch vessel morphology after fenestrated thoracoabdominal aneurysm repair with the BeGraft balloon-expandable covered stent","volume":"74","author":"Tran","journal-title":"J Vasc Surg"},{"issue":"1","key":"R19","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/j.jvs.2022.01.135","article-title":"Impact of gap distance between fenestration and aortic wall on target artery instability following fenestrated-branched endovascular aortic repair","volume":"76","author":"Chait","journal-title":"J Vasc Surg"},{"issue":"5","key":"R20","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1177\/1538574419840880","article-title":"Initial experience with Viabahn VBX as the bridging stent graft for branched and fenestrated endovascular aneurysm repair","volume":"53","author":"Mafeld","journal-title":"Vasc Endovascular Surg"},{"issue":"2","key":"R21","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1016\/j.jvs.2020.05.028","article-title":"Performance of Viabahn balloon-expandable stent compared with self-expandable covered stents for branched endovascular aortic repair","volume":"73","author":"Motta","journal-title":"J Vasc Surg"},{"issue":"6","key":"R22","doi-asserted-by":"publisher","first-page":"1376","DOI":"10.1016\/j.jvs.2023.07.061","article-title":"One-year results of a balloon expandable endoprosthesis as a bridging stent for branched endovascular aortic repair","volume":"78","author":"Usai","journal-title":"J Vasc Surg"},{"issue":"1","key":"R23","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1177\/15266028241248600","article-title":"Three-dimensional geometric analysis of Viabahn VBX bridging stent grafts in fenestrated endovascular aortic repair: a multicenter, retrospective cohort study","volume":"33","author":"Fouad","journal-title":"J Endovasc Ther"},{"key":"R24","doi-asserted-by":"publisher","DOI":"10.1177\/15266028241300005","article-title":"Mid-term outcomes of the Viabahn balloon-expandable endoprosthesis as bridging stent graft for fenestrated and branched endovascular aortic repair","author":"Kappe","journal-title":"J Endovasc Ther"},{"issue":"2","key":"R25","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1016\/j.jvs.2024.10.002","article-title":"A three-year experience with the balloon expandable GORE VIABAHN VBX in the treatment of thoraco-abdominal aortic aneurysms within the EXPAND trial","volume":"81","author":"Usai","journal-title":"J Vasc Surg"},{"issue":"5","key":"R26","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.1016\/j.jvs.2023.12.037","article-title":"Comparison of bridging stent grafts in branched endovascular aortic repair","volume":"79","author":"Migliari","journal-title":"J Vasc Surg"}],"container-title":["JMIR Research Protocols"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.researchprotocols.org\/2026\/1\/e78970","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T18:11:48Z","timestamp":1782843108000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.researchprotocols.org\/2026\/1\/e78970"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,27]]},"references-count":26,"URL":"https:\/\/doi.org\/10.2196\/78970","relation":{},"ISSN":["1929-0748"],"issn-type":[{"value":"1929-0748","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,27]]},"article-number":"v15i1e78970"}}