{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T19:05:24Z","timestamp":1782846324714,"version":"3.54.5"},"reference-count":19,"publisher":"JMIR Publications Inc.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JMIR Res Protoc"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec sec-type=\"background\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The accurate transfer of implant positions from the patient\u2019s mouth to the laboratory is crucial for the successful fabrication of prostheses in implant-based prosthodontics. Making an implant impression is a crucial part of this procedure as it replicates the intraoral implant position and transfers it to the cast to be used in the laboratory for fabricating a passive fit prosthesis. The purpose of this study is to compare and assess the accuracy of implant impressions made with prefabricated self-perforating trays and custom acrylic trays.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"objective\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>The primary objective is to compare the dimensional accuracy of implant impressions made using custom acrylic trays versus prefabricated self-perforating trays in an in vitro setting. The secondary objective is to determine whether the impressions made with prefabricated self-perforating trays achieve clinically acceptable accuracy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A partially edentulous mandibular model with implants placed at the second premolar and first molar region will function as a master model. Impressions will be made using the custom acrylic tray and prefabricated self-perforating implant impression tray. The cast obtained will be scanned, and an STL file will be generated to evaluate the accuracy of implant positions using HyperMesh software. Statistical analysis will be done with IBM SPSS Statistics at a 95% CI and 80% power.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The study aims to evaluate whether there is a statistically significant difference in the accuracy of implant casts obtained using prefabricated self-perforating trays versus custom acrylic trays. As of July 2025, the models have been prepared for further analysis. It is projected that data collection will be completed in May 2026, with results to be published in early 2027.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"conclusions\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>For the success of implant dentistry, the precise fit of the final prosthesis has become a necessity. A mismatched framework may overload the implant, endangering its durability. To achieve a precise fit of the implant framework, a precise definitive cast is necessary, which depends on several factors, one of them being the implant impression tray selection. Traditionally, custom acrylic trays have been used. However, they are impractical to use in routine clinical practice due to certain disadvantages. A newer range of trays for the open tray impression technique is being marketed, and one would be able to reduce the additional expense and laboratory time associated with using custom acrylic trays by using this newer variety of self-perforating implant impression tray.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2196\/79452","type":"journal-article","created":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T07:40:06Z","timestamp":1753861206000},"page":"e79452-e79452","source":"Crossref","is-referenced-by-count":0,"title":["In Vitro Comparison of the Dimensional Accuracy of Implant Impressions Using Custom Acrylic Trays and Prefabricated Self-Perforating Trays: Protocol for a Comparative Evaluation Study"],"prefix":"10.2196","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-1070-4153","authenticated-orcid":false,"given":"Arti","family":"Agrawal","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1188-7300","authenticated-orcid":false,"given":"Sharayu","family":"Nimonkar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3642-9787","authenticated-orcid":false,"given":"Surekha","family":"Godbole","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-4360-8057","authenticated-orcid":false,"given":"Rushabh","family":"Parakh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8667-5011","authenticated-orcid":false,"given":"Vikram","family":"Belkhode","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-7046-8942","authenticated-orcid":false,"given":"Namita","family":"Zilpilwar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1010","published-online":{"date-parts":[[2026,2,19]]},"reference":[{"issue":"6","key":"R1","first-page":"1422","volume":"27","author":"Mpikos","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"8","key":"R2","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1038\/sj.bdj.2011.862","article-title":"Impressions in implant dentistry","volume":"211","author":"Bhakta","journal-title":"Br Dent J"},{"issue":"3","key":"R3","doi-asserted-by":"publisher","first-page":"271","DOI":"10.4103\/jips.jips_232_17","article-title":"Need for a reliable alternative to custom-made Implant Impression trays: an  study comparing accuracy of custom trays versus specialized aluminum stock tray","volume":"18","author":"Goel","journal-title":"J Indian Prosthodont Soc"},{"issue":"1","key":"R4","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-023-03583-x","article-title":"Comparative evaluation of open tray impression technique: investigating the precision of four splinting materials in multiple implants","volume":"23","author":"Patil","journal-title":"BMC Oral Health"},{"key":"R5","doi-asserted-by":"publisher","DOI":"10.11606\/issn.2357-8041.clrd.2017.135626","article-title":"Accuracy of self-perforating impression tray for maxillary dental implant","author":"Bohner","journal-title":"Clinical and Laboratorial Research in Dentistry"},{"issue":"2","key":"R6","doi-asserted-by":"publisher","first-page":"808","DOI":"10.1016\/j.jds.2023.01.012","article-title":"Accuracy of digital impressions for implant-supported complete-arch prosthesis when using an auxiliary geometry device","volume":"18","author":"Arikan","journal-title":"J Dent Sci"},{"issue":"3","key":"R7","doi-asserted-by":"publisher","first-page":"239","DOI":"10.4103\/jips.jips_27_18","article-title":"Evaluation of positional accuracy in multiple implants using four different splinting materials: an  study","volume":"18","author":"Joseph","journal-title":"J Indian Prosthodont Soc"},{"issue":"1","key":"R8","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1007\/s13191-013-0343-x","article-title":"Passive fit in screw retained multi-unit implant prosthesis understanding and achieving: a review of the literature","volume":"14","author":"Buzayan","journal-title":"J Indian Prosthodont Soc"},{"issue":"2","key":"R9","first-page":"167","volume":"12","author":"Wee","journal-title":"Int J Prosthodont"},{"key":"R10","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/6306530","article-title":"In vitro comparative evaluation of different types of impression trays and impression materials on the accuracy of open tray implant impressions: a pilot study","volume":"2017","author":"Gupta","journal-title":"Int J Dent"},{"key":"R11","unstructured":"Mahesh L Kurtzman G . Advances in dental impressions. Impladent. 2015. URL: https:\/\/www.centrefordentalimplant.com\/wp-content\/uploads\/2016\/11\/ADVANCES-IN-IMPLANT-IMPRESSIONS.pdf [Accessed 27-01-2026]"},{"issue":"6","key":"R12","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1016\/S0022-3913(11)60075-9","article-title":"Accuracy of implant impressions without impression copings: a three-dimensional analysis","volume":"105","author":"Kwon","journal-title":"J Prosthet Dent"},{"issue":"4","key":"R13","doi-asserted-by":"publisher","first-page":"287","DOI":"10.4047\/jap.2017.9.4.287","article-title":"Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique","volume":"9","author":"Pastoret","journal-title":"J Adv Prosthodont"},{"key":"R14","doi-asserted-by":"publisher","DOI":"10.7860\/JCDR\/2022\/53057.16014","article-title":"Implant impression techniques using different materials and methods: a review","volume":"16","author":"Yasar","journal-title":"JCDR"},{"issue":"4","key":"R15","doi-asserted-by":"publisher","first-page":"185","DOI":"10.4103\/0972-4052.30693","article-title":"Comparative evaluation of accuracy of six different implant impression techniques: an in vitro study","volume":"6","author":"Madhan","journal-title":"J Indian Prosthodont Soc"},{"issue":"4","key":"R16","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1016\/0022-3913(90)90235-5","article-title":"An evaluation of impression techniques for osseointegrated implants","volume":"63","author":"Spector","journal-title":"J Prosthet Dent"},{"issue":"4","key":"R17","first-page":"367","volume":"9","author":"Rueda","journal-title":"Int J Prosthodont"},{"issue":"5","key":"R18","doi-asserted-by":"publisher","DOI":"10.2196\/25244","article-title":"Assessment of outcomes of immediately loaded dental implants in orofacial cleft patients: protocol for a single-arm clinical trial","volume":"10","author":"Mallick","journal-title":"JMIR Res Protoc"},{"issue":"1","key":"R19","doi-asserted-by":"publisher","DOI":"10.2196\/13237","article-title":"The effects of titanium implant surface topography on osseointegration: literature review","volume":"4","author":"Kumar","journal-title":"JMIR Biomed Eng"}],"container-title":["JMIR Research Protocols"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.researchprotocols.org\/2026\/1\/e79452","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T18:12:29Z","timestamp":1782843149000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.researchprotocols.org\/2026\/1\/e79452"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,19]]},"references-count":19,"URL":"https:\/\/doi.org\/10.2196\/79452","relation":{},"ISSN":["1929-0748"],"issn-type":[{"value":"1929-0748","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,19]]},"article-number":"v15i6e79452"}}