{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T19:06:39Z","timestamp":1782846399187,"version":"3.54.5"},"reference-count":38,"publisher":"JMIR Publications Inc.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JMIR Biomed Eng"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec sec-type=\"background\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Adapting physical activity monitors to detect gait events (ie, at initial and final contact) has the potential to build a more personalized approach to gait rehabilitation after stroke. Meeting laboratory standards for detecting these events in impaired populations is challenging, without resorting to a multisensor solution. The Teager-Kaiser energy operator (TKEO) estimates the instantaneous energy of a signal; its enhanced sensitivity has successfully detected gait events from the acceleration signals of individuals with impaired mobility, but has not been applied to stroke.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"objective\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This study aimed to test the criterion validity of TKEO gait event detection (and derived spatiotemporal metrics) using data from thigh mounted physical activity monitors compared with concurrent 3D motion capture in chronic survivors of stroke.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Participants with a history of stroke(n=13, mean age 59, SD 14 years), time since stroke (mean 1.5, SD 0.5 years), walking speed (mean 0.93\n                      <jats:sub>\n                        <jats:italic>ms<\/jats:italic>\n                      <\/jats:sub>\n                      <jats:sup>\n                        <jats:sub>\u22121<\/jats:sub>\n                      <\/jats:sup>\n                      , SD 0.38 m\/s) performed two 10m walks at their comfortable speed, while wearing two ActivPAL 4+ (AP4) sensors (anterior of both thighs) and LED cluster markers on the pelvis and ankles which were tracked by a motion capture system. The TKEO signal processing technique was then used to extract gait events (initial and final contact) and calculate stance durations which were compared with motion capture data.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>There was very good agreement between the AP4 and motion capture data for stance duration (AP4 0.85s, motion capture system 0.88s, 95% CI of difference \u22120.07 to 0.13, intraclass correlation coefficient [3,1]=0.79).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"conclusions\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The TKEO method for gait event detection using AP4 data provides stance time durations that are comparable with laboratory-based systems in a population with chronic stroke. Providing accurate stance time durations from wearable sensors could extend gait training out of clinical environments. Limitations include ecological and external validity. Future work should confirm findings with a larger sample of participants with a history of stroke.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2196\/80308","type":"journal-article","created":{"date-parts":[[2025,10,2]],"date-time":"2025-10-02T06:40:09Z","timestamp":1759387209000},"page":"e80308-e80308","source":"Crossref","is-referenced-by-count":0,"title":["Thigh-Worn Sensor for Measuring Initial and Final Contact During Gait in a Mobility Impaired Population: Validation Study"],"prefix":"10.2196","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-7138-4338","authenticated-orcid":false,"given":"Thomas","family":"Johnson","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-9978-1096","authenticated-orcid":false,"given":"Janeesata","family":"Kuntapun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1318-0007","authenticated-orcid":false,"given":"Craig","family":"Childs","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7666-9283","authenticated-orcid":false,"given":"Andrew","family":"Kerr","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1010","published-online":{"date-parts":[[2025,10,30]]},"reference":[{"issue":"3","key":"R1","doi-asserted-by":"publisher","DOI":"10.1002\/pri.1948","article-title":"Embodiment, tailoring, and trust are important for co\u2010construction of meaning in physiotherapy after stroke: a qualitative study","volume":"27","author":"Sivertsen","journal-title":"Physiotherapy Res Intl"},{"issue":"10","key":"R2","doi-asserted-by":"publisher","first-page":"2821","DOI":"10.1007\/s40520-021-01812-3","article-title":"Impact of an individual personalised rehabilitation program on mobility performance in older-old people","volume":"33","author":"Rinc\u00e9","journal-title":"Aging Clin Exp Res"},{"issue":"9778","key":"R3","doi-asserted-by":"publisher","first-page":"1693","DOI":"10.1016\/S0140-6736(11)60325-5","article-title":"Stroke rehabilitation","volume":"377","author":"Langhorne","journal-title":"The Lancet"},{"issue":"6","key":"R4","doi-asserted-by":"publisher","first-page":"521","DOI":"10.3109\/17483107.2013.840863","article-title":"Developing a personalised self-management system for post stroke rehabilitation; utilising a user-centred design methodology","volume":"9","author":"Mawson","journal-title":"Disability and Rehabilitation: Assistive Technology"},{"key":"R5","doi-asserted-by":"crossref","unstructured":"Harris NR Sthapit D . Towards a personalised rehabilitation system for post stroke treatment. Presented at: 2016 IEEE Sensors Applications Symposium (SAS); Apr 20-22, 2016; Catania, Italy. [doi: 10.1109\/SAS.2016.7479848]","DOI":"10.1109\/SAS.2016.7479848"},{"issue":"3","key":"R6","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1016\/j.gaitpost.2011.10.358","article-title":"Predictors of gait velocity among community-dwelling stroke survivors","volume":"35","author":"Taylor-Piliae","journal-title":"Gait Posture"},{"issue":"1","key":"R7","doi-asserted-by":"publisher","DOI":"10.1186\/s12883-021-02072-4","article-title":"The parameters of gait analysis related to ambulatory and balance functions in hemiplegic stroke patients: a gait analysis study","volume":"21","author":"Chang","journal-title":"BMC Neurol"},{"issue":"8","key":"R8","doi-asserted-by":"publisher","first-page":"1185","DOI":"10.1016\/s0003-9993(03)00030-3","article-title":"Analysis of impairments influencing gait velocity and asymmetry of hemiplegic patients after mild to moderate stroke","volume":"84","author":"Hsu","journal-title":"Arch Phys Med Rehabil"},{"issue":"5","key":"R9","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1080\/10749357.2019.1605751","article-title":"Walking speed as a predictor of community mobility and quality of life after stroke","volume":"26","author":"Grau-Pellicer","journal-title":"Top Stroke Rehabil"},{"key":"R10","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2022.989622","article-title":"Walking speed at the acute and subacute stroke stage: a descriptive meta-analysis","volume":"13","author":"Tasseel-Ponche","journal-title":"Front Neurol"},{"issue":"5","key":"R11","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1007\/BF02443147","article-title":"Temporal asymmetry as a gait quality indicator","volume":"18","author":"Dewar","journal-title":"Med Biol Eng Comput"},{"issue":"9","key":"R12","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1177\/1545968310372091","article-title":"Changes in gait symmetry and velocity after stroke: a cross-sectional study from weeks to years after stroke","volume":"24","author":"Patterson","journal-title":"Neurorehabil Neural Repair"},{"issue":"6","key":"R13","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1080\/10749357.2017.1285746","article-title":"A systematic review of mechanisms of gait speed change post-stroke. Part 1: spatiotemporal parameters and asymmetry ratios","volume":"24","author":"Wonsetler","journal-title":"Top Stroke Rehabil"},{"key":"R14","doi-asserted-by":"crossref","unstructured":"Zhou L Rackoll T Ekrod L et al. Monitoring and visualizing stroke rehabilitation progress using wearable sensors. Presented at: 2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC); Jul 15-19, 2024; Orlando, FL, USA. [doi: 10.1109\/EMBC53108.2024.10782489]","DOI":"10.1109\/EMBC53108.2024.10782489"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2022.08.002","article-title":"Validity of the activPAL monitor to measure stepping activity and activity intensity: a systematic review","volume":"97","author":"Wu","journal-title":"Gait & Posture"},{"issue":"2","key":"R16","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1016\/j.jshs.2016.02.002","article-title":"Considerations when using the activPAL monitor in field-based research with adult populations","volume":"6","author":"Edwardson","journal-title":"J Sport Health Sci"},{"key":"R17","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2024.1286447","article-title":"Agreement between the activPAL accelerometer and direct observation during a series of gait and sit-to-stand tasks in people living with cervical dystonia","volume":"15","author":"Yaqoob","journal-title":"Front Neurol"},{"issue":"2","key":"R18","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1080\/09638288.2022.2157896","article-title":"Validity of the activPAL and ActiGraph for measuring sitting time and steps in hospitalised orthopaedic patients with altered weight bearing","volume":"46","author":"Kirk","journal-title":"Disabil Rehabil"},{"issue":"5","key":"R19","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1093\/ptj\/pzx010","article-title":"Validity of different activity monitors to count steps in an inpatient rehabilitation setting","volume":"97","author":"Treacy","journal-title":"Phys Ther"},{"key":"R20","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2020.06.004","article-title":"Gait event detection using a thigh-worn accelerometer","volume":"80","author":"Gurchiek","journal-title":"Gait & Posture"},{"issue":"4","key":"R21","doi-asserted-by":"publisher","DOI":"10.1115\/1.4064435","article-title":"A novel gait event detection algorithm using a thigh-worn inertial measurement unit and joint angle information","volume":"146","author":"Strick","journal-title":"J Biomech Eng"},{"issue":"1","key":"R22","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1109\/TNSRE.2004.843176","article-title":"Automated estimation of initial and terminal contact timing using accelerometers; development and validation in transtibial amputees and controls","volume":"13","author":"Selles","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"1","key":"R23","doi-asserted-by":"publisher","DOI":"10.1186\/1743-0003-9-9","article-title":"Bilateral step length estimation using a single inertial measurement unit attached to the pelvis","volume":"9","author":"K\u00f6se","journal-title":"J Neuroeng Rehabil"},{"key":"R24","doi-asserted-by":"crossref","unstructured":"Lee HK Hwang SJ Cho SP Lee DR You SH Lee KJ . Novel algorithm for the hemiplegic gait evaluation using a single 3-axis accelerometer. Presented at: 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society; Sep 3-6, 2009; Minneapolis, MN. [doi: 10.1109\/IEMBS.2009.5333650]","DOI":"10.1109\/IEMBS.2009.5333650"},{"key":"R25","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2024.3407887","article-title":"Estimation of gait parameters in Huntington\u2019s disease using wearable sensors in the clinic and free-living conditions","volume":"32","author":"Lozano-Garcia","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"3","key":"R26","doi-asserted-by":"publisher","first-page":"658","DOI":"10.1109\/TBME.2019.2919394","article-title":"Gait event detection from accelerometry using the Teager\u2013Kaiser Energy Operator","volume":"67","author":"Flood","journal-title":"IEEE Trans Biomed Eng"},{"issue":"4","key":"R27","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1016\/j.gaitpost.2007.07.007","article-title":"Two simple methods for determining gait events during treadmill and overground walking using kinematic data","volume":"27","author":"Zeni","journal-title":"Gait & Posture"},{"key":"R28","doi-asserted-by":"crossref","unstructured":"Kaiser DA Kaiser JF . Estimation of power systems amplitudes, frequencies, and phase characteristics using energy operators. Presented at: 2012 IEEE Energy Conversion Congress and Exposition (ECCE); Sep 15-20, 2012; Raleigh, NC, USA. [doi: 10.1109\/ECCE.2012.6342719]","DOI":"10.1109\/ECCE.2012.6342719"},{"key":"R29","doi-asserted-by":"publisher","DOI":"10.2196\/57227","article-title":"A participatory model for cocreating accessible rehabilitation technology for stroke survivors: user-centered design approach","volume":"11","author":"Kerr","journal-title":"JMIR Rehabil Assist Technol"},{"key":"R30","doi-asserted-by":"publisher","DOI":"10.2196\/46619","article-title":"An intensive exercise program using a technology-enriched rehabilitation gym for the recovery of function in people with chronic stroke: usability study","volume":"10","author":"Kerr","journal-title":"JMIR Rehabil Assist Technol"},{"issue":"10","key":"R31","doi-asserted-by":"publisher","first-page":"3135","DOI":"10.1161\/STROKEAHA.114.004590","article-title":"Use of Montreal Cognitive Assessment in patients with stroke","volume":"45","author":"Chiti","journal-title":"Stroke"},{"issue":"10","key":"R32","doi-asserted-by":"publisher","first-page":"1314","DOI":"10.1016\/j.apmr.2007.06.764","article-title":"Predictive validity and responsiveness of the functional ambulation category in hemiparetic patients after stroke","volume":"88","author":"Mehrholz","journal-title":"Arch Phys Med Rehabil"},{"issue":"6","key":"R33","doi-asserted-by":"publisher","first-page":"1086","DOI":"10.1016\/j.apmr.2011.12.015","article-title":"The Rivermead mobility index allows valid comparisons between subgroups of patients undergoing rehabilitation after stroke who differ with respect to age, sex, or side of lesion","volume":"93","author":"Roorda","journal-title":"Arch Phys Med Rehabil"},{"key":"R34","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2018.08.025","article-title":"Analysis of the performance of 17 algorithms from a systematic review: Influence of sensor position, analysed variable and computational approach in gait timing estimation from IMU measurements","volume":"66","author":"Pacini Panebianco","journal-title":"Gait & Posture"},{"issue":"1","key":"R35","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1097\/MRR.0000000000000391","article-title":"Gait characteristics of post-stroke hemiparetic patients with different walking speeds","volume":"43","author":"Wang","journal-title":"Int J Rehabil Res"},{"issue":"4","key":"R36","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1016\/j.gaitpost.2010.09.009","article-title":"Changes of locomotion in old age depend on task setting","volume":"32","author":"Bock","journal-title":"Gait & Posture"},{"issue":"1","key":"R37","doi-asserted-by":"publisher","DOI":"10.1038\/s41531-021-00171-0","article-title":"Gait speed in clinical and daily living assessments in Parkinson\u2019s disease patients: performance versus capacity","volume":"7","author":"Atrsaei","journal-title":"NPJ Parkinsons Dis"},{"key":"R38","unstructured":"Johnson T Kerr A . Data for \"thigh-worn sensor for measuring initial and final contact during gait in a mobility impaired population: a validation study\". University of Strathclyde, Glasgow. URL: https:\/\/pureportal.strath.ac.uk\/en\/datasets\/data-for-thigh-worn-sensor-for-measuring-initial-and-final-contac\/"}],"container-title":["JMIR Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/biomedeng.jmir.org\/2025\/1\/e80308","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T18:13:44Z","timestamp":1782843224000},"score":1,"resource":{"primary":{"URL":"https:\/\/biomedeng.jmir.org\/2025\/1\/e80308"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,30]]},"references-count":38,"URL":"https:\/\/doi.org\/10.2196\/80308","relation":{},"ISSN":["2561-3278"],"issn-type":[{"value":"2561-3278","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,30]]},"article-number":"v10i3e80308"}}