{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:44:21Z","timestamp":1785545061129,"version":"3.56.0"},"reference-count":46,"publisher":"JMIR Publications Inc.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JMIR Form Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec sec-type=\"background\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Wearable inertial measurement units (IMUs) offer scalable, objective gait assessment, but detailed stride-level validation against motion capture and their ability to reflect physical activity (PA)\u2013related gait differences in knee osteoarthritis (KOA) remain incompletely characterized.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"objective\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This study aimed to evaluate the technical validity of foot-mounted IMU\u2013derived gait parameters compared with optical motion capture in individuals with KOA and healthy controls. As a secondary exploratory aim, we assessed whether IMU-derived gait parameters differed across self-reported PA levels.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In this pilot cross-sectional validation study, 20 participants (KOA: n=10, 50%; healthy controls: n=10, 50%) completed 3 standardized walking conditions (self-paced, fast-paced, and endurance-equivalent). IMU-derived gait parameters were compared with motion capture at the stride level (\u22655000 strides) using Pearson correlation, intraclass correlation coefficients (ICCs), mean absolute error, root mean square error, and Bland-Altman analysis. Participants completed the Stanford Brief Activity Survey to categorize PA level. Secondary analyses emphasized effect sizes and 95% CIs given the pilot design. Feasibility was assessed by protocol completion, data completeness, and tolerability.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      IMU-derived gait speed demonstrated strong agreement with motion capture (\n                      <jats:italic>r<\/jats:italic>\n                      =0.99; ICC=0.98, 95% CI 0.95\u20100.99; mean absolute error=0.07 m\/s; bias=0.01 m\/s; 95% limits of agreement \u22120.14 to 0.16 m\/s). Stride length and cadence showed similarly high agreement (ICC range 0.96\u20100.97). All participants completed the protocol with minimal adverse events. Exploratory analyses suggested that participants reporting higher PA demonstrated directionally faster gait speed and longer stride length, with small-to-moderate effect sizes, whereas inactive participants exhibited higher stance-related rhythm parameters.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"conclusions\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Foot-mounted IMUs demonstrated strong stride-level agreement with motion capture across walking conditions, supporting technical validity in both KOA and healthy populations. Exploratory findings suggest that wearable-derived gait parameters may reflect activity-related differences; however, larger longitudinal studies are required to confirm these preliminary signals.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2196\/80728","type":"journal-article","created":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T08:20:07Z","timestamp":1773303607000},"page":"e80728-e80728","source":"Crossref","is-referenced-by-count":0,"title":["Wearable Sensor\u2013Derived Gait Parameters Across Self-Reported Physical Activity Levels in Individuals With Knee Osteoarthritis and Healthy Controls: Pilot Cross-Sectional Validation Study"],"prefix":"10.2196","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8280-4015","authenticated-orcid":false,"given":"Charles Amoatey","family":"Odonkor","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1137-3350","authenticated-orcid":false,"given":"Siri","family":"Bohacek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9614-3211","authenticated-orcid":false,"given":"Salman","family":"Hirani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6022-6832","authenticated-orcid":false,"given":"Wei","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8227-4149","authenticated-orcid":false,"given":"Amir","family":"Muaremi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9931-2271","authenticated-orcid":false,"given":"Heike","family":"Leutheuser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2990-069X","authenticated-orcid":false,"given":"Matthew","family":"Smuck","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1010","published-online":{"date-parts":[[2026,6,3]]},"reference":[{"issue":"7","key":"R1","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1136\/annrheumdis-2013-204763","article-title":"The global burden of hip and knee osteoarthritis: estimates from the global burden of disease 2010 study","volume":"73","author":"Cross","journal-title":"Ann Rheum Dis"},{"issue":"3","key":"R2","doi-asserted-by":"publisher","first-page":"219","DOI":"10.5792\/ksrr.2016.28.3.219","article-title":"Quality of life and functional independence in patients with osteoarthritis of the knee","volume":"28","author":"Araujo","journal-title":"Knee Surg Relat Res"},{"issue":"2","key":"R3","doi-asserted-by":"publisher","DOI":"10.1136\/rmdopen-2018-000715","article-title":"Patient-reported outcome measures in osteoarthritis: a systematic search and review of their use and psychometric properties","volume":"4","author":"Lundgren-Nilsson","journal-title":"RMD Open"},{"issue":"9","key":"R4","doi-asserted-by":"publisher","first-page":"1721","DOI":"10.1093\/rheumatology\/ket216","article-title":"The clinical utility of accelerometry in patients with rheumatoid arthritis","volume":"52","author":"Prioreschi","journal-title":"Rheumatology (Oxford)"},{"issue":"1","key":"R5","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.spinee.2018.07.007","article-title":"Digital biomarkers of spine and musculoskeletal disease from accelerometers: defining phenotypes of free-living physical activity in knee osteoarthritis and lumbar spinal stenosis","volume":"19","author":"Tomkins-Lane","journal-title":"Spine J"},{"key":"R6","doi-asserted-by":"publisher","DOI":"10.3389\/fspor.2023.1236143","article-title":"Measuring objective physical activity in people with chronic low back pain using accelerometers: a scoping review","volume":"5","author":"Berger","journal-title":"Front Sports Act Living"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2020.05.019","article-title":"Gait features for discriminating between mobility-limiting musculoskeletal disorders: lumbar spinal stenosis and knee osteoarthritis","volume":"80","author":"Odonkor","journal-title":"Gait Posture"},{"issue":"8","key":"R8","doi-asserted-by":"publisher","first-page":"977","DOI":"10.1097\/00005768-199708000-00001","article-title":"Compliance to exercise therapy in older participants with knee osteoarthritis: implications for treating disability","volume":"29","author":"Rejeski","journal-title":"Med Sci Sports Exerc"},{"issue":"7","key":"R9","doi-asserted-by":"publisher","DOI":"10.3390\/s17071522","article-title":"Towards mobile gait analysis: concurrent validity and test-retest reliability of an inertial measurement system for the assessment of spatio-temporal gait parameters","volume":"17","author":"Kluge","journal-title":"Sensors (Basel)"},{"key":"R10","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2019.109567","article-title":"Measuring markers of aging and knee osteoarthritis gait using inertial measurement units","volume":"99","author":"Hafer","journal-title":"J Biomech"},{"issue":"8","key":"R11","doi-asserted-by":"publisher","DOI":"10.3390\/s24082413","article-title":"The analytical validity of stride detection and gait parameters reconstruction using the ankle-mounted inertial measurement unit Syde\u00ae","volume":"24","author":"Michaud","journal-title":"Sensors (Basel)"},{"issue":"1","key":"R12","doi-asserted-by":"publisher","DOI":"10.3390\/s19010038","article-title":"Towards inertial sensor based mobile gait analysis: event-detection and spatio-temporal parameters","volume":"19","author":"Teufl","journal-title":"Sensors (Basel)"},{"issue":"5","key":"R13","doi-asserted-by":"publisher","DOI":"10.3390\/s20051343","article-title":"Accuracy verification of spatio-temporal and kinematic parameters for gait using inertial measurement unit system","volume":"20","author":"Yeo","journal-title":"Sensors (Basel)"},{"key":"R14","doi-asserted-by":"publisher","DOI":"10.7717\/peerj.16641","article-title":"Validation of an algorithm to assess regular and irregular gait using inertial sensors in healthy and stroke individuals","volume":"11","author":"Ensink","journal-title":"PeerJ"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2024.10.013","article-title":"Validity of IMU sensors for assessing features of walking in laboratory and outdoor environments among older adults","volume":"114","author":"Matikainen-Tervola","journal-title":"Gait Posture"},{"issue":"17","key":"R16","doi-asserted-by":"publisher","first-page":"5501","DOI":"10.3390\/s25175501","article-title":"Comparison of wearable and depth-sensing technologies with electronic walkway for comprehensive gait analysis","volume":"25","author":"Nassajpour","journal-title":"Sensors (Basel)"},{"issue":"6","key":"R17","doi-asserted-by":"publisher","first-page":"635","DOI":"10.3944\/AOTT.2014.13.0071","article-title":"Effects of severity of osteoarthritis on the temporospatial gait parameters in patients with knee osteoarthritis","volume":"48","author":"Ta\u015f","journal-title":"Acta Orthop Traumatol Turc"},{"issue":"1","key":"R18","doi-asserted-by":"publisher","DOI":"10.1177\/2055102914564582","article-title":"Self-efficacy and arthritis disability: an updated synthesis of the evidence base and its relevance to optimal patient care","volume":"1","author":"Marks","journal-title":"Health Psychol Open"},{"issue":"2","key":"R19","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1016\/j.joca.2012.11.008","article-title":"Knee joint loading during gait in healthy controls and individuals with knee osteoarthritis","volume":"21","author":"Kumar","journal-title":"Osteoarthritis Cartilage"},{"issue":"11","key":"R20","doi-asserted-by":"publisher","first-page":"1234","DOI":"10.1016\/j.joca.2012.08.004","article-title":"Body mass index affects knee joint mechanics during gait differently with and without moderate knee osteoarthritis","volume":"20","author":"Harding","journal-title":"Osteoarthritis Cartilage"},{"issue":"10","key":"R21","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2011.08.223","article-title":"The association of accelerometer-based activity monitoring with chronic low back pain","volume":"11","author":"Smuck","journal-title":"Spine J"},{"issue":"9","key":"R22","doi-asserted-by":"publisher","first-page":"1229","DOI":"10.1002\/art.24007","article-title":"Physical activity levels in patients with early knee osteoarthritis measured by accelerometry","volume":"59","author":"Farr","journal-title":"Arthritis Rheum"},{"issue":"9","key":"R23","doi-asserted-by":"publisher","first-page":"1939","DOI":"10.1002\/acr.25096","article-title":"Reliability of wearable sensors for assessing gait and chair stand function at home in people with knee osteoarthritis","volume":"75","author":"Rose","journal-title":"Arthritis Care Res (Hoboken)"},{"issue":"23","key":"R24","doi-asserted-by":"publisher","DOI":"10.3390\/s22239301","article-title":"Gait variability to phenotype common orthopedic gait impairments using wearable sensors","volume":"22","author":"Kushioka","journal-title":"Sensors (Basel)"},{"key":"R25","doi-asserted-by":"publisher","DOI":"10.2174\/1874120701509010157","article-title":"Accelerometer-based physical activity monitoring in patients with knee osteoarthritis: objective and ambulatory assessment of actual physical activity during daily life circumstances","volume":"9","author":"Verlaan","journal-title":"Open Biomed Eng J"},{"issue":"3","key":"R26","doi-asserted-by":"publisher","DOI":"10.3390\/jfmk10030288","article-title":"Wearable sensor assessment of gait characteristics in individuals awaiting total knee arthroplasty: a cross-sectional, observational study","volume":"10","author":"Gianzina","journal-title":"J Funct Morphol Kinesiol"},{"issue":"6","key":"R27","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1016\/j.pmrj.2011.03.002","article-title":"Comparison of self-reported knee injury and osteoarthritis outcome score to performance measures in patients after total knee arthroplasty","volume":"3","author":"Stevens-Lapsley","journal-title":"PM R"},{"issue":"12","key":"R28","doi-asserted-by":"publisher","first-page":"1532","DOI":"10.1093\/gerona\/glt060","article-title":"A comparison of straight- and curved-path walking tests among mobility-limited older adults","volume":"68","author":"Odonkor","journal-title":"J Gerontol A Biol Sci Med Sci"},{"issue":"11","key":"R29","doi-asserted-by":"publisher","first-page":"2127","DOI":"10.1111\/j.1532-5415.2012.04209.x","article-title":"Gait and cognition: a complementary approach to understanding brain function and the risk of falling","volume":"60","author":"Montero-Odasso","journal-title":"J Am Geriatr Soc"},{"issue":"1","key":"R30","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/s0167-4943(03)00082-7","article-title":"Predicting falls within the elderly community: comparison of postural sway, reaction time, the Berg balance scale and the Activities-specific Balance Confidence (ABC) scale for comparing fallers and non-fallers","volume":"38","author":"Lajoie","journal-title":"Arch Gerontol Geriatr"},{"issue":"15","key":"R31","doi-asserted-by":"publisher","first-page":"2999","DOI":"10.1016\/j.jbiomech.2010.07.003","article-title":"3D gait assessment in young and elderly subjects using foot-worn inertial sensors","volume":"43","author":"Mariani","journal-title":"J Biomech"},{"key":"R32","doi-asserted-by":"publisher","DOI":"10.12688\/f1000research.51700.2","article-title":"Comparison of gender, age, and body mass index for spatiotemporal parameters of bilateral gait pattern","volume":"10","author":"Abualait","journal-title":"F1000Res"},{"key":"R33","doi-asserted-by":"publisher","DOI":"10.1016\/j.exger.2023.112102","article-title":"Age-related changes in gait biomechanics and their impact on the metabolic cost of walking: report from a National Institute on Aging workshop","volume":"173","author":"Boyer","journal-title":"Exp Gerontol"},{"issue":"5","key":"R34","doi-asserted-by":"publisher","first-page":"540","DOI":"10.1016\/j.soard.2009.05.003","article-title":"Six-minute walk test: functional capacity of severely obese before and after bariatric surgery","volume":"5","author":"de Souza","journal-title":"Surg Obes Relat Dis"},{"issue":"3","key":"R35","doi-asserted-by":"publisher","DOI":"10.1016\/j.arrct.2021.100147","article-title":"Examining the association between self-reported estimates of function and objective measures of gait and physical capacity in lumbar stenosis","volume":"3","author":"Odonkor","journal-title":"Arch Rehabil Res Clin Transl"},{"issue":"2","key":"R36","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.gaitpost.2012.07.012","article-title":"Quantitative estimation of foot-flat and stance phase of gait using foot-worn inertial sensors","volume":"37","author":"Mariani","journal-title":"Gait Posture"},{"issue":"10","key":"R37","doi-asserted-by":"publisher","DOI":"10.3390\/s18103322","article-title":"Gait symmetry assessment with a low back 3D accelerometer in post-stroke patients","volume":"18","author":"Zhang","journal-title":"Sensors (Basel)"},{"issue":"11","key":"R38","doi-asserted-by":"publisher","first-page":"1792","DOI":"10.1016\/j.joca.2017.06.006","article-title":"Reliability and measurement error of the Osteoarthritis Research Society International (OARSI) recommended performance-based tests of physical function in people with hip and knee osteoarthritis","volume":"25","author":"Dobson","journal-title":"Osteoarthritis Cartilage"},{"issue":"6","key":"R39","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1097\/00005650-199206000-00002","article-title":"The MOS 36-item short-form health survey (SF-36). I. Conceptual framework and item selection","volume":"30","author":"Ware","journal-title":"Med Care"},{"issue":"7","key":"R40","doi-asserted-by":"publisher","first-page":"1028","DOI":"10.1002\/acr.21655","article-title":"Association of slower walking speed with incident knee osteoarthritis-related outcomes","volume":"64","author":"Purser","journal-title":"Arthritis Care Res (Hoboken)"},{"issue":"2","key":"R41","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1038\/nrrheum.2015.135","article-title":"Strategies for the prevention of knee osteoarthritis","volume":"12","author":"Roos","journal-title":"Nat Rev Rheumatol"},{"key":"R42","doi-asserted-by":"publisher","DOI":"10.1155\/2019\/9757369","article-title":"Effects of knee osteoarthritis on hip and ankle gait mechanics","volume":"2019","author":"Ro","journal-title":"Adv Orthop"},{"issue":"10","key":"R43","doi-asserted-by":"publisher","first-page":"1271","DOI":"10.1136\/ard.2006.062927","article-title":"The relationship between toe-out angle during gait and progression of medial tibiofemoral osteoarthritis","volume":"66","author":"Chang","journal-title":"Ann Rheum Dis"},{"issue":"11","key":"R44","doi-asserted-by":"publisher","first-page":"2490","DOI":"10.1007\/s10439-023-03289-9","article-title":"Bilateral asymmetry in knee and hip musculoskeletal loading during stair ascending\/descending in individuals with unilateral mild-to-moderate medial knee osteoarthritis","volume":"51","author":"Liu","journal-title":"Ann Biomed Eng"},{"issue":"6","key":"R45","doi-asserted-by":"publisher","first-page":"740","DOI":"10.1054\/arth.2001.23922","article-title":"Patient satisfaction after total knee arthroplasty: a comparison between subjective and objective outcome assessments","volume":"16","author":"Bullens","journal-title":"J Arthroplasty"},{"issue":"7","key":"R46","doi-asserted-by":"publisher","DOI":"10.3390\/jpm13071139","article-title":"Assessment of pain in osteoarthritis of the knee","volume":"13","author":"Thirumaran","journal-title":"J Pers Med"}],"container-title":["JMIR Formative Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/formative.jmir.org\/2026\/1\/e80728","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T22:26:37Z","timestamp":1785536797000},"score":1,"resource":{"primary":{"URL":"https:\/\/formative.jmir.org\/2026\/1\/e80728"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,3]]},"references-count":46,"URL":"https:\/\/doi.org\/10.2196\/80728","relation":{},"ISSN":["2561-326X"],"issn-type":[{"value":"2561-326X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,3]]},"article-number":"v10i7e80728"}}