{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:44:08Z","timestamp":1785545048587,"version":"3.56.0"},"reference-count":46,"publisher":"JMIR Publications Inc.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JMIR Biomed Eng"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec sec-type=\"background\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The application of spinal orthoses and local vibration in the treatment of hyperkyphosis is a developing concept. Further research is needed to determine the impact of leaf springs and local vibration techniques on the neuromusculoskeletal system.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"objective\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This study aimed to evaluate the effect of the simultaneous application of a leaf spring and a programmed local vibration system in a spinal orthosis on thoracic kyphosis angle (TKA) and the function of trunk flexor and extensor muscles.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We used a soft thoracolumbar orthosis as a base for 2 parallel leaf spring bars made from AISI (American Iron and Steel Institute) 1075 steel (45 cm \u00d7 2 cm \u00d7 2 mm each). We added 4 solenoid actuators (60 g each) housed in 2 units positioned 12 cm apart, generating 20 N vertical force at 8 Hz frequency with 10 mm free displacement. A programmable Arduino microcontroller delivered 10-second vibration bursts followed by 5-minute rest intervals, repeated for 12 cycles per session, applied every other day. One participant with hyperkyphosis (baseline TKA=47.24\u00b0) used this device for 4 weeks. Outcomes included TKA (measured by photogrammetry) and trunk muscle function (assessed under isometric, isotonic, and isokinetic conditions). Feasibility outcomes included adherence, wear time, and adverse events.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Bench testing confirmed an 8 Hz vibration frequency, a 10 mm free displacement, and an on-body contact pressure of 9.5 N\/cm\u00b2 (95 kPa). In the short-term assessment (N=10), mean acceptability scores were 7.95 (SD 0.83) for appearance and 7.6 (SD 0.07) for comfort, and no skin-related adverse events occurred. In the 4-week single-participant pilot (N=1), adherence was 100% (12\/12 sessions completed), mean daily wear time was 1.4 (SD 0.3) hours, and no adverse events were reported. TKA decreased from 47.24\u00b0 to 45.81\u00b0 (change: \u22121.43\u00b0), which did not exceed the minimal detectable change (4.62\u00b0). Pre-post changes in muscle function outcomes are reported descriptively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"conclusions\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>A semirigid thoracolumbar orthosis with integrated programmable vibration (8 Hz, 20 N free force) is technically feasible, showing reliable bench performance. Short-term assessment in 10 participants indicated acceptable comfort and appearance with no immediate safety concerns. The 4-week single-participant pilot demonstrated 100% adherence and no adverse events. The observed 1.43\u00b0 kyphosis reduction was not clinically meaningful (below minimal detectable change). Larger controlled studies are needed to determine whether this device improves muscle function or spinal alignment.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2196\/82013","type":"journal-article","created":{"date-parts":[[2026,5,25]],"date-time":"2026-05-25T12:15:07Z","timestamp":1779711307000},"page":"e82013-e82013","source":"Crossref","is-referenced-by-count":0,"title":["Effect of a Spinal Orthosis With Leaf Spring and Programmable Local Vibration on Kyphosis Angle and Trunk Muscle Strength in Hyperkyphosis: Development and Feasibility Study"],"prefix":"10.2196","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1818-4672","authenticated-orcid":false,"given":"Fatemeh","family":"Keshavarzi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6855-063X","authenticated-orcid":false,"given":"Mokhtar","family":"Arazpour","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9313-315X","authenticated-orcid":false,"given":"Saeed","family":"Behzadipour","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1010","published-online":{"date-parts":[[2026,6,25]]},"reference":[{"key":"R1","doi-asserted-by":"publisher","DOI":"10.1177\/20556683241268605","article-title":"Effect of spinal orthoses on osteoporotic elderly patients kyphosis, back muscles strength, balance and osteoporotic vertebral fractures: a systematic review and meta-analysis","volume":"11","author":"Keshavarzi","journal-title":"J Rehabil Assist Technol Eng"},{"key":"R2","doi-asserted-by":"crossref","unstructured":"Weppner JL Alfano AP . 6\u2014Principles and components of spinal orthoses. In: Webster JB Murphy DP , editors. Atlas of Orthoses and Assistive Devices. 5th ed. Elsevier; 2019:69-89.e2. [doi: 10.1016\/B978-0-323-48323-0.00006-8]","DOI":"10.1016\/B978-0-323-48323-0.00006-8"},{"issue":"3","key":"R3","doi-asserted-by":"publisher","first-page":"235","DOI":"10.4065\/71.3.235","article-title":"Effect of back supports on back strength in patients with osteoporosis: a pilot study","volume":"71","author":"Kaplan","journal-title":"Mayo Clin Proc"},{"issue":"1","key":"R4","doi-asserted-by":"publisher","first-page":"56","DOI":"10.3109\/03093649509078233","article-title":"New concept of spinal orthosis for weakened back muscles","volume":"19","author":"Watanabe","journal-title":"Prosthet Orthot Int"},{"key":"R5","doi-asserted-by":"publisher","DOI":"10.1016\/j.msksp.2021.102438","article-title":"Decreasing thoracic hyperkyphosis\u2014which treatments are most effective? A systematic literature review and meta-analysis","volume":"56","author":"Jenkins","journal-title":"Musculoskelet Sci Pract"},{"issue":"3","key":"R6","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1097\/01.phm.0000113403.16617.93","article-title":"Effects of a new spinal orthosis on posture, trunk strength, and quality of life in women with postmenopausal osteoporosis: a randomized trial","volume":"83","author":"Pfeifer","journal-title":"Am J Phys Med Rehabil"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.3389\/fpain.2022.1038269","article-title":"Effects of the \u201cSpinomed active\u201d orthosis on chronic back pain in kyphotic women with osteoporotic vertebral fractures three months and older: a randomized controlled study","volume":"3","author":"Hettchen","journal-title":"Front Pain Res (Lausanne)"},{"issue":"9","key":"R8","doi-asserted-by":"publisher","first-page":"1488","DOI":"10.1080\/09638288.2022.2065541","article-title":"Effect of a semi-rigid backpack type thoracolumbar orthosis on thoracic kyphosis angle and muscle performance in older adults with hyperkyphosis: a randomized controlled trial","volume":"45","author":"Keshavarzi","journal-title":"Disabil Rehabil"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbmt.2024.05.034","article-title":"Effects of vibration therapy on muscle soreness and athletic performance in wheelchair basketball players","volume":"40","author":"Uysal","journal-title":"J Bodyw Mov Ther"},{"issue":"8","key":"R10","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1589\/jpts.36.441","article-title":"Effects of local vibration stimulation on muscle recovery and hypertrophy","volume":"36","author":"Ishikura","journal-title":"J Phys Ther Sci"},{"issue":"3","key":"R11","doi-asserted-by":"publisher","first-page":"212","DOI":"10.21859\/jrehab-1803212","article-title":"Effect of new kypho-remainder orthosis on curve intensity in adults with postural hyper kyphosis","volume":"18","author":"Torkaman","journal-title":"Arch Rehabil"},{"issue":"4","key":"R12","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1007\/s40520-016-0617-3","article-title":"Age-related hyperkyphosis: update of its potential causes and clinical impacts-narrative review","volume":"29","author":"Roghani","journal-title":"Aging Clin Exp Res"},{"issue":"1","key":"R13","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/j.physio.2017.06.006","article-title":"Effect of localised vibration on muscle strength in healthy adults: a systematic review","volume":"104","author":"Alghadir","journal-title":"Physiotherapy"},{"key":"R14","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2021.765257","article-title":"Systematic review of back-support exoskeletons and soft robotic suits","volume":"9","author":"Ali","journal-title":"Front Bioeng Biotechnol"},{"issue":"1","key":"R15","doi-asserted-by":"publisher","DOI":"10.3390\/healthcare9010070","article-title":"Review of current spinal robotic orthoses","volume":"9","author":"Mak","journal-title":"Healthcare (Basel)"},{"issue":"4","key":"R16","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1177\/0309364620923816","article-title":"Effect of a Spinomed orthosis on balance performance, spinal alignment, joint position sense and back muscle endurance in elderly people with hyperkyphotic posture: a randomized controlled trial","volume":"44","author":"Hosseinabadi","journal-title":"Prosthet Orthot Int"},{"issue":"4","key":"R17","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0216180","article-title":"Effects of exercise programs on kyphosis and lordosis angle: a systematic review and meta-analysis","volume":"14","author":"Gonz\u00e1lez-G\u00e1lvez","journal-title":"PLoS One"},{"issue":"2","key":"R18","doi-asserted-by":"publisher","first-page":"37","DOI":"10.3390\/robotics11020037","article-title":"Active soft brace for scoliotic spine: a finite element study to evaluate in-brace correction","volume":"11","author":"Ali","journal-title":"Robotics"},{"key":"R19","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/867869","article-title":"Mechanism and design analysis of articulated ankle foot orthoses for drop-foot","volume":"2014","author":"Alam","journal-title":"Sci World J"},{"issue":"3","key":"R20","doi-asserted-by":"publisher","first-page":"1075","DOI":"10.22214\/ijraset.2021.33488","article-title":"Design and analysis of leaf spring by using composite material","volume":"9","author":"Priya","journal-title":"Int J Res Appl Sci Eng Technol"},{"issue":"4","key":"R21","doi-asserted-by":"publisher","first-page":"351","DOI":"10.32598\/irj.19.4.1412.1","article-title":"Comparing Spinomed\u00ae and elderly spinal orthosis use on kyphosis angle, back pain, and quality of life in elderly with thoracic hyperkyphosis","volume":"19","author":"Rahimi","journal-title":"Iran Rehabil J"},{"issue":"3","key":"R22","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1080\/17483107.2017.1419295","article-title":"Comparison of the immediate efficacy of the Spinomed back orthosis and posture training support on walking ability in elderly people with thoracic kyphosis","volume":"14","author":"Namdar","journal-title":"Disabil Rehabil Assist Technol"},{"key":"R23","doi-asserted-by":"publisher","DOI":"10.2147\/CIA.S199853","article-title":"Effect of a semirigid thoracolumbar orthosis on gait and sagittal alignment in patients with an osteoporotic vertebral compression fracture","volume":"14","author":"Jacobs","journal-title":"Clin Interv Aging"},{"issue":"3","key":"R24","doi-asserted-by":"publisher","DOI":"10.3390\/bioengineering12030263","article-title":"A muscle-driven spine model for predictive simulations in the design of spinal implants and lumbar orthoses","volume":"12","author":"Remus","journal-title":"Bioengineering (Basel)"},{"issue":"6","key":"R25","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1080\/00140139.2020.1870162","article-title":"Effects of industrial back-support exoskeletons on body loading and user experience: an updated systematic review","volume":"64","author":"Kermavnar","journal-title":"Ergonomics"},{"key":"R26","doi-asserted-by":"publisher","DOI":"10.1017\/wtc.2020.10","article-title":"Design and preliminary evaluation of a flexible exoskeleton to assist with lifting","volume":"1","author":"Chang","journal-title":"Wearable Technol"},{"key":"R27","doi-asserted-by":"crossref","unstructured":"Chan HH Liao H Gao F Zhao X Liao WH . A back-support exoskeleton with a cable-driven series-parallel elastic actuation: prototype design and operational analysis. Presented at: 2021 IEEE International Conference on Mechatronics and Automation (ICMA); Aug 8-11, 2021; Takamatsu, Japan. [doi: 10.1109\/ICMA52036.2021.9512832]","DOI":"10.1109\/ICMA52036.2021.9512832"},{"key":"R28","doi-asserted-by":"publisher","DOI":"10.1186\/s11556-020-00247-5","article-title":"Effects of vibration therapy on muscle mass, muscle strength and physical function in older adults with sarcopenia: a systematic review and meta-analysis","volume":"17","author":"Wu","journal-title":"Eur Rev Aging Phys Act"},{"key":"R29","volume":"91","author":"Lou","journal-title":"Stud Health Technol Inform"},{"issue":"11","key":"R30","doi-asserted-by":"publisher","first-page":"1147","DOI":"10.1007\/s11517-011-0847-7","article-title":"Development of a smart garment to reduce kyphosis during daily living","volume":"50","author":"Lou","journal-title":"Med Biol Eng Comput"},{"issue":"7","key":"R31","doi-asserted-by":"publisher","DOI":"10.1002\/hsr2.71051","article-title":"Effect of local vibration and thoracolumbar orthosis on thoracic kyphosis angle and trunk flexor and extensor muscles in older adults with hyperkyphosis: a randomized control trial","volume":"8","author":"Keshavarzi","journal-title":"Health Sci Rep"},{"issue":"7","key":"R32","doi-asserted-by":"publisher","first-page":"2969","DOI":"10.3390\/app11072969","article-title":"Focal vibration therapy: vibration parameters of effective wearable devices","volume":"11","author":"Ghazi","journal-title":"Appl Sci (Basel)"},{"issue":"12","key":"R33","doi-asserted-by":"publisher","DOI":"10.3390\/bioengineering11121242","article-title":"The biomechanics of spinal orthoses for adolescent idiopathic scoliosis: a systematic review of the controlling forces","volume":"11","author":"Luo","journal-title":"Bioengineering (Basel)"},{"issue":"13","key":"R34","doi-asserted-by":"publisher","first-page":"3018","DOI":"10.1080\/09593985.2021.1975337","article-title":"Validity and test-retest reliability of photogrammetry in adolescents with hyperkyphosis","volume":"38","author":"Azadinia","journal-title":"Physiother Theory Pract"},{"issue":"8","key":"R35","doi-asserted-by":"publisher","first-page":"712","DOI":"10.1016\/j.jmpt.2018.03.003","article-title":"Thoracic kyphosis and lumbar lordosis assessment by radiography and photogrammetry: a review of normative values and reliability","volume":"41","author":"Porto","journal-title":"J Manipulative Physiol Ther"},{"issue":"2","key":"R36","doi-asserted-by":"publisher","first-page":"136","DOI":"10.5312\/wjo.v7.i2.136","article-title":"Photogrammetry as a tool for the postural evaluation of the spine: a systematic review","volume":"7","author":"Furlanetto","journal-title":"World J Orthop"},{"issue":"1","key":"R37","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1179\/016164110X12556180206310","article-title":"Effects of 8 weeks of vibration training at different frequencies (1 or 15 Hz) in senior sportsmen on torque and force development and of 1 year of training on muscle fibers","volume":"32","author":"Kern","journal-title":"Neurol Res"},{"key":"R38","doi-asserted-by":"publisher","DOI":"10.1016\/j.jelekin.2018.02.005","article-title":"Effects of vibration-induced fatigue on the H-reflex","volume":"39","author":"Sammali","journal-title":"J Electromyogr Kinesiol"},{"issue":"2","key":"R39","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1055\/s-0031-1286294","article-title":"Chronic effects of different frequencies of local vibrations","volume":"33","author":"Couto","journal-title":"Int J Sports Med"},{"key":"R40","doi-asserted-by":"crossref","unstructured":"Raiser SN Alfano AP . 10\u2014Orthoses for osteoporosis. In: Webster JB Murphy DP , editors. Atlas of Orthoses and Assistive Devices. 5th ed. Elsevier; 2019:115-125. [doi: 10.1016\/B978-0-323-48323-0.00010-X]","DOI":"10.1016\/B978-0-323-48323-0.00010-X"},{"key":"R41","doi-asserted-by":"crossref","unstructured":"Srinivasan TM Kumar KV . A microprocessor based automated H response monitor. In: Saha S , editor. Biomedical Engineering I: Recent Developments: Proceedings of the First Southern Biomedical Engineering Conference. Pergamon; 1982:405-408. [doi: 10.1016\/B978-0-08-028826-0.50090-1]","DOI":"10.1016\/B978-0-08-028826-0.50090-1"},{"issue":"1","key":"R42","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1615\/CritRevBiomedEng.2022041625","article-title":"Impact of local vibration training on neuromuscular activity, muscle cell, and muscle strength: a review","volume":"50","author":"Masud","journal-title":"Crit Rev Biomed Eng"},{"issue":"8","key":"R43","doi-asserted-by":"publisher","first-page":"650","DOI":"10.1016\/s0268-0033(01)00064-x","article-title":"Trunk posture and spinal stability","volume":"16","author":"Granata","journal-title":"Clin Biomech (Bristol)"},{"issue":"9","key":"R44","doi-asserted-by":"publisher","first-page":"1022","DOI":"10.1093\/gerona\/62.9.1022","article-title":"Changes in antagonist muscles\u2019 coactivation in response to strength training in older women","volume":"62","author":"de Boer","journal-title":"J Gerontol A Biol Sci Med Sci"},{"issue":"12","key":"R45","doi-asserted-by":"publisher","first-page":"3707","DOI":"10.1007\/s00421-024-05553-9","article-title":"Immediate effect of local vibration on motor unit firing behavior and muscle strength in healthy young adult males","volume":"124","author":"Nishikawa","journal-title":"Eur J Appl Physiol"},{"key":"R46","doi-asserted-by":"crossref","unstructured":"Dunleavy K . Introduction to therapeutic exercise for rehabilitation. In: Dunleavy K Slowik AK , editors. Therapeutic Exercise Prescription. Elsevier; 2019:2-11. [doi: 10.1016\/B978-0-323-28053-2.00001-6]","DOI":"10.1016\/B978-0-323-28053-2.00001-6"}],"container-title":["JMIR Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/biomedeng.jmir.org\/2026\/1\/e82013","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T22:26:25Z","timestamp":1785536785000},"score":1,"resource":{"primary":{"URL":"https:\/\/biomedeng.jmir.org\/2026\/1\/e82013"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,25]]},"references-count":46,"URL":"https:\/\/doi.org\/10.2196\/82013","relation":{},"ISSN":["2561-3278"],"issn-type":[{"value":"2561-3278","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,25]]},"article-number":"v11i3e82013"}}