{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,22]],"date-time":"2026-08-22T00:12:47Z","timestamp":1787357567419,"version":"build-2736575974"},"reference-count":26,"publisher":"JMIR Publications Inc.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JMIR Form Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec sec-type=\"background\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Smartwatches have gained popularity for their potential to provide accurate measurements of various physiological parameters. However, the validity of energy expenditure (EE) across different smartwatch models remains a topic of ongoing investigation. Discrepancies between results obtained from different models and gold standard methods are particularly critical across varying exercise intensities and types, as validation studies have demonstrated overestimation when wearable activity monitors are compared with indirect calorimetry.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"objective\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This study investigated the accuracy of 2 versions of the Samsung smartwatch (Galaxy Watch [GW] 6 and 7) in measuring EE during intermittent moderate-intensity running exercises, using indirect calorimetry as the gold standard method.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This study included 148 healthy adults, comprising 80 men and 68 women. Participants performed intermittent treadmill running, consisting of walking at 5 km\u00b7h\u207b\u00b9 for 1 minute and running between 8 and 16 km\u00b7h\u207b\u00b9 for 2 minutes, based on participant preference, for a total duration of 27 minutes. The GW6 and GW7 models were used and EE was measured by indirect calorimetry using a wearable portable metabolic gas analysis system (K5; Cosmed), which is considered a gold standard method.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      No statistically significant differences were found between the GW models and the K5. The K5 showed a mean EE of 213.60 (SD 43.04) kilocalories, compared with 219.53 (SD 35.70) kilocalories for the GW6 and 202.67 (SD 47.42) kilocalories for the GW7 (all\n                      <jats:italic>P<\/jats:italic>\n                      &gt;.05). Good Spearman correlations (0.63\u20100.70) and moderate intraclass correlation coefficients (0.65\u20100.74) were found. Mean absolute percentage error values ranged from 10.10% to 12.55%. Bland-Altman analysis revealed limits of agreement for all comparisons (K5 vs GW6 and GW7, \u221261.93 to 65.80 kcal).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"conclusions\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The GW6 and GW7 devices showed moderate validity for estimating EE during intermittent running exercises, demonstrating the suitability of the GW as a low-cost and practical wearable option for daily physical activities.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2196\/83090","type":"journal-article","created":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T18:40:05Z","timestamp":1768243205000},"page":"e83090-e83090","source":"Crossref","is-referenced-by-count":2,"title":["Validity of Galaxy Watch for Estimating Energy Expenditure During Intermittent Running: Cross-Sectional Study"],"prefix":"10.2196","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9389-1639","authenticated-orcid":false,"given":"Alexandre Reis Pires","family":"Ferreira","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3068-0839","authenticated-orcid":false,"given":"Allan","family":"Inoue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-0270-6890","authenticated-orcid":false,"given":"Ramon Ludman Martins","family":"Barbosa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-2237-7309","authenticated-orcid":false,"given":"Cassio","family":"Hayek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-2185-4263","authenticated-orcid":false,"given":"Mateus","family":"Reis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7765-7391","authenticated-orcid":false,"given":"Jo\u00e3o Arthur","family":"Alc\u00e2ntara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0198-6695","authenticated-orcid":false,"given":"Augusto Hirao","family":"Shigueoka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2926-1311","authenticated-orcid":false,"given":"Marcelo Rodrigues","family":"dos Santos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1010","published-online":{"date-parts":[[2026,3,18]]},"reference":[{"key":"R1","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2022.995575","article-title":"Validity of three smartwatches in estimating energy expenditure during outdoor walking and running","volume":"13","author":"Le","journal-title":"Front Physiol"},{"issue":"7","key":"R2","doi-asserted-by":"publisher","first-page":"503","DOI":"10.70252\/NJQX2719","article-title":"Current state of commercial wearable technology in physical activity monitoring 2015-2017","volume":"11","author":"Bunn","journal-title":"Int J Exerc Sci"},{"issue":"4","key":"R3","doi-asserted-by":"publisher","first-page":"658","DOI":"10.52082\/jssm.2023.658","article-title":"Validation of Polar Grit X Pro for estimating energy expenditure during military field training: a pilot study","volume":"22","author":"Kloss","journal-title":"J Sports Sci Med"},{"issue":"8","key":"R4","doi-asserted-by":"publisher","first-page":"1817","DOI":"10.1007\/s40279-022-01665-4","article-title":"Recommendations for determining the validity of consumer wearables and smartphones for the estimation of energy expenditure: expert statement and checklist of the INTERLIVE network","volume":"52","author":"Argent","journal-title":"Sports Med"},{"key":"R5","doi-asserted-by":"publisher","DOI":"10.1186\/s12966-015-0314-1","article-title":"Systematic review of the validity and reliability of consumer-wearable activity trackers","volume":"12","author":"Evenson","journal-title":"Int J Behav Nutr Phys Act"},{"issue":"7","key":"R6","doi-asserted-by":"publisher","first-page":"456","DOI":"10.3109\/03091902.2013.831135","article-title":"Comparison of steps and energy expenditure assessment in adults of Fitbit Tracker and Ultra to the Actical and indirect calorimetry","volume":"37","author":"Adam Noah","journal-title":"J Med Eng Technol"},{"issue":"1","key":"R7","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1249\/MSS.0000000000000727","article-title":"Comparison of consumer and research monitors under semistructured settings","volume":"48","author":"Bai","journal-title":"Med Sci Sports Exerc"},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1186\/s13102-017-0089-6","article-title":"Validity of sports watches when estimating energy expenditure during running","volume":"9","author":"Roos","journal-title":"BMC Sports Sci Med Rehabil"},{"issue":"1","key":"R9","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1016\/j.jclinepi.2010.03.002","article-title":"Guidelines for reporting reliability and agreement studies (GRRAS) were proposed","volume":"64","author":"Kottner","journal-title":"J Clin Epidemiol"},{"issue":"6","key":"R10","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1001\/archderm.1988.01670060015008","article-title":"The validity and practicality of sun-reactive skin types I through VI","volume":"124","author":"Fitzpatrick","journal-title":"Arch Dermatol"},{"issue":"1","key":"R11","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1007\/s00421-020-04514-2","article-title":"Reliability and validity of the COSMED K5 portable metabolic system during walking","volume":"121","author":"DeBlois","journal-title":"Eur J Appl Physiol"},{"issue":"4","key":"R12","doi-asserted-by":"publisher","DOI":"10.2196\/35626","article-title":"Accuracy and precision of energy expenditure, heart rate, and steps measured by combined-sensing Fitbits against reference measures: systematic review and meta-analysis","volume":"10","author":"Chevance","journal-title":"JMIR mHealth uHealth"},{"issue":"9","key":"R13","doi-asserted-by":"publisher","first-page":"482","DOI":"10.1016\/j.jsams.2023.07.005","article-title":"Validity of Apple Watch 6 and Polar A370 for monitoring energy expenditure while resting or performing light to vigorous physical activity","volume":"26","author":"Sun","journal-title":"J Sci Med Sport"},{"issue":"8","key":"R14","doi-asserted-by":"publisher","first-page":"1619","DOI":"10.1249\/MSS.0000000000000933","article-title":"Validity of consumer-based physical activity monitors for specific activity types","volume":"48","author":"Nelson","journal-title":"Med Sci Sports Exerc"},{"issue":"1","key":"R15","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1249\/MSS.0b013e31818cb278","article-title":"Progressive statistics for studies in sports medicine and exercise science","volume":"41","author":"Hopkins","journal-title":"Med Sci Sports Exerc"},{"key":"R16","doi-asserted-by":"publisher","DOI":"10.2196\/52312","article-title":"Accuracy of the Apple Watch Series 4 and Fitbit Versa for assessing energy expenditure and heart rate of wheelchair users during treadmill wheelchair propulsion: cross-sectional study","volume":"8","author":"Danielsson","journal-title":"JMIR Form Res"},{"issue":"5","key":"R17","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1213\/ANE.0000000000002864","article-title":"Correlation coefficients: appropriate use and interpretation","volume":"126","author":"Schober","journal-title":"Anesth Analg"},{"issue":"2","key":"R18","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo","journal-title":"J Chiropr Med"},{"key":"R19","volume":"19","author":"Hopkins","journal-title":"Sportscience"},{"issue":"2","key":"R20","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1139\/apnm-2019-0129","article-title":"Use of consumer monitors for estimating energy expenditure in youth","volume":"45","author":"LaMunion","journal-title":"Appl Physiol Nutr Metab"},{"key":"R21","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2017.00725","article-title":"Criterion-validity of commercially available physical activity tracker to estimate step count, covered distance and energy expenditure during sports conditions","volume":"8","author":"Wahl","journal-title":"Front Physiol"},{"issue":"3","key":"R22","doi-asserted-by":"publisher","DOI":"10.2196\/11889","article-title":"Accuracy of Apple Watch measurements for heart rate and energy expenditure in patients with cardiovascular disease: cross-sectional study","volume":"7","author":"Falter","journal-title":"JMIR mHealth uHealth"},{"issue":"11","key":"R23","doi-asserted-by":"publisher","first-page":"2907","DOI":"10.1007\/s40279-024-02077-2","article-title":"Keeping pace with wearables: a living umbrella review of systematic reviews evaluating the accuracy of consumer wearable technologies in health measurement","volume":"54","author":"Doherty","journal-title":"Sports Med"},{"issue":"10","key":"R24","doi-asserted-by":"publisher","first-page":"847","DOI":"10.1055\/s-0034-1371837","article-title":"Accuracy of energy expenditure estimation by activity monitors differs with ethnicity","volume":"35","author":"Brazeau","journal-title":"Int J Sports Med"},{"issue":"5","key":"R25","doi-asserted-by":"publisher","DOI":"10.2196\/16716","article-title":"Wrist-worn wearables for monitoring heart rate and energy expenditure while sitting or performing light-to-vigorous physical activity: validation study","volume":"8","author":"D\u00fcking","journal-title":"JMIR mHealth uHealth"},{"issue":"9","key":"R26","doi-asserted-by":"publisher","DOI":"10.2196\/18694","article-title":"Reliability and validity of commercially available wearable devices for measuring steps, energy expenditure, and heart rate: systematic review","volume":"8","author":"Fuller","journal-title":"JMIR mHealth uHealth"}],"container-title":["JMIR Formative Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/formative.jmir.org\/2026\/1\/e83090","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T18:17:10Z","timestamp":1782843430000},"score":1,"resource":{"primary":{"URL":"https:\/\/formative.jmir.org\/2026\/1\/e83090"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,18]]},"references-count":26,"URL":"https:\/\/doi.org\/10.2196\/83090","relation":{},"ISSN":["2561-326X"],"issn-type":[{"value":"2561-326X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,18]]},"article-number":"v10i7e83090"}}