{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:43:51Z","timestamp":1785545031380,"version":"3.56.0"},"reference-count":66,"publisher":"JMIR Publications Inc.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JMIR Hum Factors"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec sec-type=\"background\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Digital decision-support tools for labor care remain limited, with few technologies successfully addressing the complex, time-sensitive decisions required during labor triage. Fit4Labour is a clinician-facing, data-driven research tool, currently under development, that combines computerized cardiotocography interpretation with maternal and fetal risk factors to generate individualized risk scores at labor onset. Its primary aim is to support clinicians in identifying fetuses who may require closer monitoring or expedited delivery, while simultaneously providing reassurance in low-risk cases. By promoting consistent communication and timely escalation of care, the Fit4Labour tool seeks to strengthen clinical decision-making. Understanding and addressing usability and implementation barriers will be critical to its adoption in clinical practice.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"objective\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This study aims to evaluate whether a digitally co-developed labor decision-support tool (Fit4Labour) maintains usability and implementation readiness across NHS hospitals with differing clinical contexts.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We conducted a convergent parallel mixed methods study in 3 United Kingdom hospitals (December 2022 to May 2025). Phase 1 involved iterative co-development with midwives and doctors at Oxford University Hospitals NHS Foundation Trust; Phase 2 validated the locked version at Birmingham Women\u2019s and Children\u2019s NHS Foundation Trust and Buckinghamshire Healthcare NHS Trust. Participants completed scenario-based usability sessions evaluated with the System Usability Scale (SUS) and Single Ease Question (SEQ), and task completion time, followed by focus groups and interviews analyzed thematically.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Twenty-six health care professionals participated: 12 in co-development (7 midwives, 5 doctors) and 14 in validation (8 midwives, 6 doctors) phases. During co-development at Oxford, the tool met the \u201cexcellent\u201d usability threshold (mean SUS 82.1, SD 12.3), indicating readiness for the validation phase. The locked version (v4.0) independently met the \u201cexcellent\u201d threshold at both validation sites (combined mean SUS 85.8, SD 10.2; Birmingham 80.7, SD 10.8; Buckinghamshire 90.8, SD 7.2). Task completion times were comparable across validation sites (Birmingham 10.3, SD 1.6 min; Buckinghamshire 9.2, SD 1.9 min), while SEQ scores were consistently high across all scenarios (mean 6.1\/7, SD 0.8). Thematic analysis identified 12 themes within 3 domains: clinical integration and workflow, technology adoption and implementation, and patient safety and decision-making. Participants described the Fit4Labour tool as a supportive tool, \u201clike a co-pilot,\u201d improving confidence in decisions with the potential to aid triage assessment. Perceived limitations included an incomplete risk factor profile and the need for minor technical adjustments or integration with existing hospital systems.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"conclusions\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Through systematic co-development, the Fit4Labour tool met the established usability benchmark at 2 independent NHS hospitals with markedly different clinical contexts. Clinicians viewed the tool as a supportive aid providing a shared language for risk communication and enhanced decision-making while preserving clinical autonomy. Whether these usability findings translate to improved clinical outcomes in real-world practice requires prospective evaluation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2196\/87589","type":"journal-article","created":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T18:50:07Z","timestamp":1782240607000},"page":"e87589-e87589","source":"Crossref","is-referenced-by-count":0,"title":["Multicenter Usability Evaluation and Co-Development of a Digital Decision-Support Tool for Labor Triage: Mixed Methods Study"],"prefix":"10.2196","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1503-4161","authenticated-orcid":false,"given":"Mariana","family":"Tome","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1966-008X","authenticated-orcid":false,"given":"Xavier","family":"Laurent","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-4636-5594","authenticated-orcid":false,"given":"Kristiyan","family":"Georgiev","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-4119-9562","authenticated-orcid":false,"given":"John","family":"Tolladay","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5202-5336","authenticated-orcid":false,"given":"Sarah","family":"Collins","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-2112-595X","authenticated-orcid":false,"given":"Deborah","family":"Hedgecott","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2784-2040","authenticated-orcid":false,"given":"Lyuba V","family":"Bozhilova","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0176-2651","authenticated-orcid":false,"given":"Jane E","family":"Hirst","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4462-112X","authenticated-orcid":false,"given":"Lawrence","family":"Impey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5543-6683","authenticated-orcid":false,"given":"Antoniya","family":"Georgieva","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1010","published-online":{"date-parts":[[2026,7,23]]},"reference":[{"issue":"21","key":"R1","doi-asserted-by":"publisher","first-page":"2199","DOI":"10.1001\/jama.2018.17163","article-title":"Clinical decision support in the era of artificial intelligence","volume":"320","author":"Shortliffe","journal-title":"JAMA"},{"issue":"1","key":"R2","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1038\/s41591-018-0300-7","article-title":"High-performance medicine: the convergence of human and artificial intelligence","volume":"25","author":"Topol","journal-title":"Nat Med"},{"issue":"14","key":"R3","doi-asserted-by":"publisher","first-page":"1347","DOI":"10.1056\/NEJMra1814259","article-title":"Machine learning in medicine","volume":"380","author":"Rajkomar","journal-title":"N Engl J Med"},{"issue":"1","key":"R4","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-019-0158-1","article-title":"Why digital medicine depends on interoperability","volume":"2","author":"Lehne","journal-title":"NPJ Digit Med"},{"key":"R5","unstructured":"Global Strategy on Digital Health 2020-2025. World Health Organization; 2021. ISBN: 978-92-4-002092-4"},{"issue":"1","key":"R6","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.ijgo.2015.06.020","article-title":"FIGO consensus guidelines on intrapartum fetal monitoring: cardiotocography","volume":"131","author":"Ayres\u2010de\u2010Campos","journal-title":"Intl J Gynecology & Obste"},{"key":"R7","unstructured":"WHO Recommendations: Intrapartum Care for a Positive Childbirth Experience. World Health Organization; 2018. ISBN: 978-92-4-155021-5"},{"key":"R8","unstructured":"Fetal monitoring in labour [NG229]. National Institute for Health and Care Excellence (NICE). 2022. URL: https:\/\/www.nice.org.uk\/guidance\/ng229 [Accessed 11-07-2026]"},{"key":"R9","doi-asserted-by":"crossref","unstructured":"Norman DA , editor. User Centered System Design: New Perspectives on Human-Computer Interaction. CRC Press; 1986. [doi: 10.1201\/9780367807320]","DOI":"10.1201\/9780367807320"},{"issue":"6","key":"R10","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1197\/jamia.M1370","article-title":"Ten commandments for effective clinical decision support: making the practice of evidence-based medicine a reality","volume":"10","author":"Bates","journal-title":"J Am Med Inform Assoc"},{"issue":"7494","key":"R11","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1136\/bmj.38398.500764.8F","article-title":"Improving clinical practice using clinical decision support systems: a systematic review of trials to identify features critical to success","volume":"330","author":"Kawamoto","journal-title":"BMJ"},{"issue":"Suppl 1","key":"R12","doi-asserted-by":"publisher","first-page":"i50","DOI":"10.1136\/qshc.2005.015842","article-title":"Work system design for patient safety: the SEIPS model","volume":"15 Suppl 1","author":"Carayon","journal-title":"Qual Saf Health Care"},{"issue":"5","key":"R13","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1177\/1356262214556550","article-title":"Patient safety and interactive medical devices: realigning work as imagined and work as done","volume":"20","author":"Blandford","journal-title":"Clin Risk"},{"issue":"1","key":"R14","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.jbi.2004.11.005","article-title":"A user-centered framework for redesigning health care interfaces","volume":"38","author":"Johnson","journal-title":"J Biomed Inform"},{"issue":"e1","key":"R15","doi-asserted-by":"publisher","first-page":"e9","DOI":"10.1136\/amiajnl-2013-001684","article-title":"Ten key considerations for the successful implementation and adoption of large-scale health information technology","volume":"20","author":"Cresswell","journal-title":"J Am Med Inform Assoc"},{"key":"R16","doi-asserted-by":"publisher","DOI":"10.3389\/fdgth.2022.1030194","article-title":"Implementation of health technology: directions for research and practice","volume":"4","author":"van Gemert-Pijnen","journal-title":"Front Digit Health"},{"issue":"14","key":"R17","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1001\/archinternmed.2011.327","article-title":"Defining health information technology-related errors: new developments since to err is human","volume":"171","author":"Sittig","journal-title":"Arch Intern Med"},{"issue":"2","key":"R18","doi-asserted-by":"publisher","DOI":"10.1177\/14604582241252763","article-title":"Evaluating health information systems-related errors using the human, organization, process, technology-fit (HOPT-fit) framework","volume":"30","author":"Yusof","journal-title":"Health Informatics J"},{"issue":"1","key":"R19","doi-asserted-by":"publisher","DOI":"10.1186\/s12913-024-12060-2","article-title":"The influence of electronic health record design on usability and medication safety: systematic review","volume":"25","author":"Cahill","journal-title":"BMC Health Serv Res"},{"key":"R20","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejogrb.2023.05.021","article-title":"A retrospective observational study of labour ward work Intensity: the challenge of maternity staffing","volume":"286","author":"Creswell","journal-title":"Eur J Obstetrics &amp; Gynecol Reprod Biol"},{"issue":"1","key":"R21","doi-asserted-by":"publisher","DOI":"10.1186\/s12913-024-10812-8","article-title":"The association between midwifery staffing and reported harmful incidents: a cross-sectional analysis of routinely collected data","volume":"24","author":"Turner","journal-title":"BMC Health Serv Res"},{"key":"R22","unstructured":"Maternity triage (Good Practice Paper No. 17). RCOG; 2023. URL: https:\/\/www.rcog.org.uk\/guidance\/browse-all-guidance\/good-practice-papers\/maternity-triage-good-practice-paper-no-17\/ [Accessed 11-07-2026]"},{"key":"R23","doi-asserted-by":"publisher","DOI":"10.1016\/j.hfh.2024.100065","article-title":"Nurse-centered co-design of an electronic health record nursing summary","volume":"5","author":"Park","journal-title":"Human Factors in Healthcare"},{"key":"R24","unstructured":"Intrapartum care [NG235]. National Institute for Health and Care Excellence (NICE). 2023. URL: https:\/\/www.nice.org.uk\/guidance\/ng235 [Accessed 11-07-2026]"},{"issue":"7","key":"R25","doi-asserted-by":"publisher","first-page":"853","DOI":"10.1111\/1471-0528.18097","article-title":"Advancements in fetal heart rate monitoring: a report on opportunities and strategic initiatives for better intrapartum care","volume":"132","author":"Lovers","journal-title":"BJOG"},{"key":"R26","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejogrb.2016.08.017","article-title":"Interobserver agreement in CTG interpretation using the 2015 FIGO guidelines for intrapartum fetal monitoring","volume":"205","author":"Rei","journal-title":"Eur J Obst Gynecol Reprod Biol"},{"issue":"1","key":"R27","doi-asserted-by":"publisher","DOI":"10.1080\/14767058.2024.2425758","article-title":"Interobserver agreement of intrapartum cardiotocography interpretation by midwives using current FIGO and physiology-based guidelines","volume":"37","author":"Neri","journal-title":"J Mater Fetal Neonatal Med"},{"issue":"2","key":"R28","doi-asserted-by":"publisher","first-page":"e79","DOI":"10.1055\/s-0038-1641569","article-title":"Implementing obstetric early warning systems","volume":"8","author":"Friedman","journal-title":"AJP Rep"},{"key":"R29","unstructured":"Ockenden D . Findings, conclusions and essential actions from the independent review of maternity services at the shrewsbury and telford hospital NHS trust. Department of Health and Social Care; 2022. URL: https:\/\/www.gov.uk\/government\/publications\/final-report-of-the-ockenden-review\/ockenden-review-summary-of-findings-conclusions-and-essential-actions [Accessed 11-07-2026]"},{"key":"R30","unstructured":"Knight M Bunch K Tuffnell D et al. Saving Lives, Improving Mothers\u2019 Care-Lessons Learned to Inform Maternity Care from the UK and Ireland Confidential Enquiries into Maternal Deaths and Morbidity 2017-19. MBRRACE-UK; 2021. ISBN: 978-1-8383678-9-3"},{"issue":"5","key":"R31","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1016\/s0277-9536(96)00221-3","article-title":"Shared decision-making in the medical encounter: what does it mean? (or it takes at least two to tango)","volume":"44","author":"Charles","journal-title":"Soc Sci Med"},{"issue":"10080","key":"R32","doi-asserted-by":"publisher","first-page":"1719","DOI":"10.1016\/S0140-6736(17)30568-8","article-title":"Computerised interpretation of fetal heart rate during labour (INFANT): a randomised controlled trial","volume":"389","author":"INFANT Collaborative Group","journal-title":"Lancet"},{"issue":"3","key":"R33","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1515\/JPM.2008.030","article-title":"Omniview-SisPorto 3.5 - a central fetal monitoring station with online alerts based on computerized cardiotocogram+ST event analysis","volume":"36","author":"Ayres-de-Campos","journal-title":"J Perinat Med"},{"key":"R34","author":"Bozhilova","journal-title":"Lancet Digital Health (forthcoming)"},{"key":"R35","doi-asserted-by":"publisher","DOI":"10.1145\/353485.353487","article-title":"Distributed cognition: toward a new foundation for human-computer interaction research","volume":"Interaction7","author":"Hollan","journal-title":"ACM Transactions on Computer-Human"},{"issue":"11","key":"R36","doi-asserted-by":"publisher","first-page":"1669","DOI":"10.1080\/00140139.2013.838643","article-title":"SEIPS 2.0: a human factors framework for studying and improving the work of healthcare professionals and patients","volume":"56","author":"Holden","journal-title":"Ergonomics"},{"key":"R37","unstructured":"Nielsen J . Usability Engineering. Morgan Kaufmann; 1994. ISBN: 978-0-08-052029-2"},{"key":"R38","unstructured":"Creswell JW Plano Clark VL . Designing and Conducting Mixed Methods Research. Sage Publications; 2017. ISBN: 978-1-4833-4437-9"},{"issue":"5","key":"R39","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1007\/s10488-013-0528-y","article-title":"Purposeful sampling for qualitative data collection and analysis in mixed method implementation research","volume":"42","author":"Palinkas","journal-title":"Adm Policy Ment Health"},{"key":"R40","doi-asserted-by":"crossref","unstructured":"Brooke J . SUS -- a quick and dirty usability scale. In: Usability Evaluation In Industry. CRC Press; 1996:189-194. [doi: 10.1201\/9781498710411-35]","DOI":"10.1201\/9781498710411-35"},{"key":"R41","author":"Bangor","journal-title":"J Usability"},{"issue":"2","key":"R42","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1191\/1478088706qp063oa","article-title":"Using thematic analysis in psychology","volume":"3","author":"Braun","journal-title":"Qual Res Psychol"},{"issue":"4","key":"R43","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1080\/2159676X.2019.1628806","article-title":"Reflecting on reflexive thematic analysis","volume":"11","author":"Braun","journal-title":"Qual Res Sport Exer Health"},{"issue":"1","key":"R44","doi-asserted-by":"publisher","DOI":"10.1186\/s12913-024-11862-8","article-title":"The digitalization of emergency department triage: the perspectives of health professionals and patients","volume":"24","author":"Morlotti","journal-title":"BMC Health Serv Res"},{"issue":"2","key":"R45","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1111\/aogs.14498","article-title":"Computerized cardiotocography analysis during labor \u2013 a state\u2010of\u2010the\u2010art review","volume":"102","author":"Ben M\u2019Barek","journal-title":"Acta Obstet Gynecol Scand"},{"issue":"3","key":"R46","doi-asserted-by":"publisher","first-page":"483","DOI":"10.26574\/maedica.2023.18.3.483","article-title":"Conventional cardiotocography versus computerized CTG analysis and perinatal outcomes: a systematic review","volume":"18","author":"Tsipoura","journal-title":"Maedica (Bucur)"},{"key":"R47","doi-asserted-by":"publisher","DOI":"10.3389\/frai.2021.765210","article-title":"Challenges of developing robust AI for intrapartum fetal heart rate monitoring","volume":"4","author":"O\u2019Sullivan","journal-title":"Front Artif Intell"},{"issue":"1","key":"R48","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1007\/s00404-019-05151-7","article-title":"Use of artificial intelligence (AI) in the interpretation of intrapartum fetal heart rate (FHR) tracings: a systematic review and meta-analysis","volume":"300","author":"Balayla","journal-title":"Arch Gynecol Obstet"},{"key":"R49","doi-asserted-by":"publisher","DOI":"10.1016\/j.artmed.2019.101762","article-title":"Clinical decision support systems for triage in the emergency department using intelligent systems: a review","volume":"102","author":"Fernandes","journal-title":"Artif Intell Med"},{"key":"R50","unstructured":"Investigation report: delays to intrapartum intervention once fetal compromise is suspected. Healthcare Safety Investigation Branch; 2022. URL: https:\/\/www.hssib.org.uk\/patient-safety-investigations\/delays-to-intrapartum-intervention-once-fetal-compromise-is-suspected\/investigation-report\/ [Accessed 11-07-2026]"},{"issue":"3","key":"R51","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1136\/bmjqs-2013-001812","article-title":"Human factors and ergonomics as a patient safety practice","volume":"23","author":"Carayon","journal-title":"BMJ Qual Saf"},{"issue":"1","key":"R52","doi-asserted-by":"publisher","DOI":"10.1186\/s12910-023-00990-1","article-title":"AI-driven decision support systems and epistemic reliance: a qualitative study on obstetricians\u2019 and midwives\u2019 perspectives on integrating AI-driven CTG into clinical decision making","volume":"25","author":"Dlugatch","journal-title":"BMC Med Ethics"},{"key":"R53","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejogrb.2022.12.008","article-title":"Artificial intelligence and machine learning in cardiotocography: a scoping review","volume":"281","author":"Aeberhard","journal-title":"European Journal of Obstetrics & Gynecology and Reproductive Biology"},{"issue":"7","key":"R54","doi-asserted-by":"publisher","first-page":"1479","DOI":"10.1111\/jan.12307","article-title":"The concept of shared mental models in healthcare collaboration","volume":"70","author":"McComb","journal-title":"J Adv Nurs"},{"issue":"5","key":"R55","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1177\/2516043518805326","article-title":"Reaching common ground: the role of shared mental models in patient safety","volume":"23","author":"Wu","journal-title":"Journal of Patient Safety and Risk Management"},{"issue":"2","key":"R56","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1055\/s-0038-1648222","article-title":"Perceived burden of EHRs on physicians at different stages of their career","volume":"9","author":"Khairat","journal-title":"Appl Clin Inform"},{"key":"R57","unstructured":"NHS resolution annual report and accounts 2024 to 2025. NHS Resolution; 2025. URL: https:\/\/www.gov.uk\/government\/publications\/nhs-resolution-annual-report-and-accounts-2024-to-2025 [Accessed 11-07-2026]"},{"key":"R58","unstructured":"NHS facing \u2018absolutely shocking\u2019 \u00a327bn bill for maternity failings in England. The Guardian. Jul 20, 2025. URL: https:\/\/www.theguardian.com\/society\/2025\/jul\/20\/nhs-facing-absolutely-shocking-27bn-bill-for-maternity-failings-in-england [Accessed 11-07-2026]"},{"key":"R59","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijmedinf.2023.105073","article-title":"Increasing acceptance of medical AI: the role of medical staff participation in AI development","volume":"175","author":"Huo","journal-title":"Int J Med Inform"},{"issue":"4","key":"R60","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1093\/jcr\/ucz013","article-title":"Resistance to medical artificial intelligence","volume":"46","author":"Longoni","journal-title":"J Consum Res"},{"issue":"1","key":"R61","doi-asserted-by":"publisher","DOI":"10.1186\/s13012-022-01245-0","article-title":"The updated consolidated framework for implementation research based on user feedback","volume":"17","author":"Damschroder","journal-title":"Implementation Sci"},{"issue":"5","key":"R62","doi-asserted-by":"publisher","first-page":"935","DOI":"10.1097\/AOG.0000000000004363","article-title":"Rethinking bias to achieve maternal health equity: changing organizations, not just individuals","volume":"137","author":"Green","journal-title":"Obstet Gynecol"},{"issue":"1","key":"R63","doi-asserted-by":"publisher","DOI":"10.1186\/s13012-023-01261-8","article-title":"Implementation costs of hospital-based computerised decision support systems: a systematic review","volume":"18","author":"Donovan","journal-title":"Implementation Sci"},{"issue":"6","key":"R64","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1007\/s40273-024-01366-y","article-title":"Developing a program costs checklist of digital health interventions: a scoping review and empirical case study","volume":"42","author":"Khan","journal-title":"Pharmacoeconomics"},{"key":"R65","unstructured":"What\u2019s the real cost of EHR implementation for healthcare providers in 2026? Sprypt. 2024. URL: https:\/\/www.sprypt.com\/blog\/guide-to-the-cost-of-ehr-implementation-for-healthcare-providers [Accessed 11-07-2026]"},{"key":"R66","unstructured":"Clinical investigations of medical devices \u2013 guidance for manufacturers. UK Government. 2025. URL: https:\/\/www.gov.uk\/guidance\/notify-mhra-about-a-clinical-investigation-for-a-medical-device [Accessed 11-07-2026]"}],"container-title":["JMIR Human Factors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/humanfactors.jmir.org\/2026\/1\/e87589","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T22:25:10Z","timestamp":1785536710000},"score":1,"resource":{"primary":{"URL":"https:\/\/humanfactors.jmir.org\/2026\/1\/e87589"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,23]]},"references-count":66,"URL":"https:\/\/doi.org\/10.2196\/87589","relation":{},"ISSN":["2292-9495"],"issn-type":[{"value":"2292-9495","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,23]]},"article-number":"v13i21e87589"}}