{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T17:26:02Z","timestamp":1787851562655,"version":"build-2784847793"},"reference-count":68,"publisher":"JMIR Publications Inc.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JMIR Mhealth Uhealth"],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Over the past decade, wearable activity monitoring (WAM) devices have become prevalent to improve quality of life and support the prevention and management of a wide range of health disorders. WAM devices based on the Internet of Medical Things (IoMT) paradigm provide a practical means of tracking physical activity, but their widespread adoption raises sustainability concerns. Meanwhile, health technology assessment and life cycle assessment are typically applied at advanced development stages, when empirical certainty about the final design and operating conditions is available, leaving little room for further improvements.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This exploratory work provides the empirical foundations for an information-driven approach addressing this paradox in the early evaluation and conception of wrist-worn step counters, for which evidence suggests overdimensioned and unsustainable electronic designs. Specifically, we identify optimal resource-performance trade-offs in critical electronic components of frugal smartbands based on the data they collect and the information they preserve for step counting. This approach accounts for uncertainties in device reliability, users\u2019 gait speeds, and material and energy consumption in final products.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We conducted a secondary analysis of an accelerometer dataset characterizing wrist motion in healthy individuals walking at different speeds. The original x-, y-, and z-axis signals were progressively downsampled using cubic spline interpolation and discretized to quantify the information preserved, first across sampling frequencies and then with respect to changes in motion velocity. We also preliminarily assessed the viability of the downsampled signals for step detection by estimating percentage errors in peak and valley counts. Based on this, we constructed and evaluated 4 frugal smartband design archetypes, linking energy consumption and sampling frequency for 4 widely used accelerometers and combining essential electronic components, implementing a suboptimal asynchronous first-in-first-out (FIFO) algorithm at different sampling rates. Finally, we evaluated the environmental impact and circularity of these components through a streamlined analysis focused on raw materials.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>About 70%\u201090% of the information is lost in signals downsampled at very low frequencies (2\u20105 Hz), whereas losses remain below 24% from 20 Hz onward. Substantial information loss also occurs when individuals walk briskly or jog (\u22658 km\/h), or walk below 8 km\/h with sampling frequencies below 7 Hz or above 25 Hz. Step-counting accuracy is expected to be acceptable from approximately 11 Hz onward. Conversely, higher sampling rates rapidly saturate FIFO buffers and increase energy overhead, particularly when implemented in memory-dense components handling both processing and data transfer. Finally, gold and silver in transceivers and microcontrollers contribute substantially to resource depletion, while copper remains relevant for material recovery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>These findings provide preliminary insights into the concurrent assessment and development of frugal WAM devices. This work extends the understanding of step detection under knowledge-constrained conditions and provides mechanisms to reduce uncertainty during early health technology assessment and eco-design.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2196\/88237","type":"journal-article","created":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T13:30:08Z","timestamp":1782307808000},"page":"e88237","source":"Crossref","is-referenced-by-count":0,"title":["An Information-Driven Approach for the Early Health Technology Sustainability Assessment and the Frugal Design of the Internet of Medical Things: Exploratory Study of Wearable Activity Monitoring Devices"],"prefix":"10.2196","volume":"14","author":[{"given":"Ernesto","family":"Quisbert-Trujillo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicolas","family":"Vuillerme","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1010","published-online":{"date-parts":[[2026,7,31]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/S2589-7500(22)00111-X"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.2196\/59507"},{"key":"ref3","year":"2018","journal-title":"Global Action Plan on Physical Activity 2018-2030: More Active People for a Healthier World"},{"key":"ref4","unstructured":"Wearable technology market (2026-2033): size, share & trends analysis2026062026-06-09Grand View Researchhttps:\/\/tinyurl.com\/3s3b7pf2"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1038\/s41586-025-09819-w"},{"key":"ref6","unstructured":"Life cycle assessment for Galaxy WatchesSamsung2026-03-03https:\/\/www.samsung.com\/global\/sustainability\/policy-file\/AYmutOga96AALYNW\/LCA_Results_for_Watch.pdf"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-024-79732-1"},{"key":"ref8","unstructured":"Apple Watch Series 2: environmental report2016092026-06-09Apple Inchttps:\/\/www.apple.com\/environment\/pdf\/products\/watch\/Apple_Watch_Series2_PER_sept2016.pdf"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.2196\/16674"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1123\/jmpb.2022-0022"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1186\/s12966-020-01020-8"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.3390\/s23218971"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-020-00684-4"},{"key":"ref14","year":"2011","journal-title":"Health Technology Assessment of Medical Devices"},{"key":"ref15","unstructured":"ISO 14040:2006 Environmental management \u2013 Life cycle assessment \u2013 Principles and frameworkInternational Organization for Standardization2006072026-06-09https:\/\/www.iso.org\/standard\/37456.html"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclepro.2011.05.021"},{"key":"ref17","author":"Graedel, T","year":"1998","journal-title":"Streamlined Life-Cycle Assessment"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.15171\/ijhpm.2019.36"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1007\/s40273-017-0509-1"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1177\/135581969700200107"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1002\/ep.670220414"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclepro.2020.125232"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclepro.2012.04.005"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1080\/17434440.2020.1743174"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.3390\/s25133839"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.3390\/s20133784"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1177\/1550147717740073"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1007\/s43926-023-00051-4"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclepro.2023.139675"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhazmat.2024.134545"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1016\/j.wasman.2023.10.008"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-89567-9"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1111\/j.1530-9290.2011.00342.x"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1002\/047174882X"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4419-7970-4"},{"key":"ref36","author":"MacKay, DJC","year":"2003","journal-title":"Information Theory, Inference, and Learning Algorithms"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.3390\/e19110631"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.3390\/jpm12050749"},{"key":"ref39","doi-asserted-by":"publisher","DOI":"10.1109\/T-AIEE.1928.5055024"},{"key":"ref40","doi-asserted-by":"publisher","DOI":"10.1109\/JRPROC.1949.232969"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1152\/japplphysiol.00138.2005"},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.1300\/J184v06n04_08"},{"key":"ref43","first-page":"236","author":"Rashkovska, A","year":"2010","journal-title":"33rd International Convention MIPRO"},{"key":"ref44","author":"Gravetter, FJ","year":"2021","journal-title":"Essentials of Statistics for the Behavioral Sciences"},{"key":"ref45","unstructured":"AN-2554: step counting using the ADXL367Analog Devices, Inc20232026-06-09https:\/\/www.analog.com\/en\/resources\/app-notes\/an-2554.html"},{"key":"ref46","doi-asserted-by":"publisher","DOI":"10.1186\/s42490-023-00071-9"},{"key":"ref47","doi-asserted-by":"publisher","DOI":"10.3390\/s151027230"},{"key":"ref48","doi-asserted-by":"publisher","DOI":"10.1017\/CBO9781107326279"},{"key":"ref49","doi-asserted-by":"publisher","DOI":"10.3390\/technologies14010024"},{"key":"ref50","unstructured":"MPU-6000 and MPU-6050 product specification revision 3.4InvenSense TDK20252026-06-09https:\/\/invensense.tdk.com\/wp-content\/uploads\/2015\/02\/MPU-6000-Datasheet1.pdf"},{"key":"ref51","unstructured":"LIS2DH12 MEMS digital output motion sensor: ultra-low-power high-performance 3-axis \u201cfemto\u201d accelerometerSTMicroelectronics20252026-06-09https:\/\/www.st.com\/en\/mems-and-sensors\/lis2dh12.html"},{"key":"ref52","unstructured":"LIS2DE12 MEMS digital output motion sensor: ultra-low-power high-performance 3-axis \u201cfemto\u201d accelerometerSTMicroelectronics20252026-06-09https:\/\/www.st.com\/en\/mems-and-sensors\/lis2de12.html"},{"key":"ref53","unstructured":"LIS2DW12 MEMS digital output motion sensor: high-performance ultralow-power 3-axis \u201cfemto\u201d accelerometerSTMicroelectronics20252026-06-09https:\/\/www.st.com\/en\/mems-and-sensors\/lis2dw12.html"},{"key":"ref54","unstructured":"Ultra-low-power Arm Cortex-M0+ MCU with 8-Kbytes of flash memory, 32 MHz CPUSTMicroelectronics20252026-06-09https:\/\/www.st.com\/en\/microcontrollers-microprocessors\/stm32l011k3.html"},{"key":"ref55","unstructured":"Ultra-low-power Arm Cortex-M0+ MCU with 32 Kbytes of flash memory, 32 MHz CPU, USB, LCDSTMicroelectronics20252026-06-09https:\/\/www.st.com\/en\/microcontrollers-microprocessors\/stm32l053c6.html"},{"key":"ref56","unstructured":"Ultra-low-power Arm Cortex-M0+ MCU with 64-Kbytes of flash memory, 32 MHz CPU, USB, LCDSTMicroelectronics20252026-06-09https:\/\/www.st.com\/en\/microcontrollers-microprocessors\/stm32l073v8.html"},{"key":"ref57","unstructured":"Ultra-low-power dual core Arm Cortex-M4 MCU 64 MHz, Cortex-M0+ 32 MHz with 320 Kbytes of flash memory, Bluetooth LE 5.4STMicroelectronics20252026-06-09https:\/\/www.st.com\/en\/microcontrollers-microprocessors\/stm32wb10cc.html"},{"key":"ref58","unstructured":"Ultra-low-power dual core Arm Cortex-M4 MCU 64 MHz, Cortex-M0+ 32 MHz with 1 Mbyte of flash memory, Bluetooth LE 5.4, 802.15.4, Zigbee, Thread, Matter, AES 256STMicroelectronics20252026-06-09https:\/\/www.st.com\/en\/microcontrollers-microprocessors\/stm32wb50cg.html"},{"key":"ref59","unstructured":"Ultra-low-power dual core Arm Cortex-M4 MCU 64 MHz, Cortex-M0+ 32 MHz with 1 Mbyte of flash memory, Bluetooth LE 5.4, 802.15.4, Zigbee, Thread, Matter, USB, LCD, AES-256STMicroelectronics20252026-06-09https:\/\/www.st.com\/en\/microcontrollers-microprocessors\/stm32wb55cg.html"},{"key":"ref60","doi-asserted-by":"publisher","DOI":"10.2760\/798894"},{"key":"ref61","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-022-00745-z"},{"key":"ref62","doi-asserted-by":"publisher","DOI":"10.1249\/MSS.0000000000001146"},{"key":"ref63","doi-asserted-by":"publisher","DOI":"10.1186\/s12913-019-4305-9"},{"key":"ref64","doi-asserted-by":"publisher","DOI":"10.1080\/1463922X.2022.2064934"},{"key":"ref65","doi-asserted-by":"publisher","DOI":"10.1039\/D5TC02280K"},{"key":"ref66","doi-asserted-by":"publisher","DOI":"10.3390\/su12208444"},{"key":"ref67","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-025-01873-9"},{"key":"ref68","doi-asserted-by":"publisher","DOI":"10.2196\/64213"}],"container-title":["JMIR mHealth and uHealth"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/mhealth.jmir.org\/2026\/1\/e88237","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T16:50:03Z","timestamp":1787849403000},"score":1,"resource":{"primary":{"URL":"https:\/\/mhealth.jmir.org\/2026\/1\/e88237"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,31]]},"references-count":68,"URL":"https:\/\/doi.org\/10.2196\/88237","relation":{},"ISSN":["2291-5222"],"issn-type":[{"value":"2291-5222","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,31]]}}}