{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T22:36:09Z","timestamp":1785537369844,"version":"3.56.0"},"reference-count":75,"publisher":"JMIR Publications Inc.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Med Internet Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec sec-type=\"background\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Sleep apnea (SA) is a serious sleep disorder, and its diagnostic gold standard, polysomnography, is costly and time-consuming. Electroencephalogram (EEG) signals, due to their direct correlation with neural activity and ease of extraction, represent a promising tool. Despite increasing research on machine learning (ML) and deep learning for EEG-based SA detection, model performance has not been consistently evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"objective\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This systematic review evaluated the accuracy of ML in detecting SA from EEG data and provided an evidence base for further clinical application and future research.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Following the PRISMA-DTA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses of Diagnostic Test Accuracy) and PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) 2020 expanded checklists, we systematically searched PubMed, Embase, Web of Science, Cochrane Library (CENTRAL), Scopus, IEEE Xplore, and ClinicalTrials.gov databases from inception to April 2026. Studies evaluating the value of ML algorithms for detecting SA based only on EEG data were included. The Quality Assessment of Diagnostic Accuracy Studies-2 and Prediction Model Risk of Bias Assessment Tool for Artificial Intelligence tools were used to assess the risk of bias in each study. Statistical analysis was performed using the\n                      <jats:italic>mada<\/jats:italic>\n                      and\n                      <jats:italic>metafor<\/jats:italic>\n                      packages in R (version 4.6.0; R Foundation for Statistical Computing) and the Meta-DiSc (version 1.4; Hospital Ram\u00f3n y Cajal) software. We used GRADE (Grading of Recommendations Assessment, Development and Evaluation) to evaluate the certainty of evidence.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 27 retrospective studies were included. Segment-level analyses showed high diagnostic performance, with a pooled sensitivity of 0.90 (95% CI 0.85\u20100.94; 95% prediction interval 0.43\u20100.99) and specificity of 0.92 (95% CI 0.87\u20100.95; 95% prediction interval 0.46\u20100.99). The pooled area under the summary receiver operating characteristic curve was 0.95 (95% CI 0.92\u20100.99). Meta-regression identified EEG channel configuration, region, and validation strategy as significant sources of heterogeneity (\n                      <jats:italic>P<\/jats:italic>\n                      =.004,\n                      <jats:italic>P<\/jats:italic>\n                      =.003, and\n                      <jats:italic>P<\/jats:italic>\n                      =.046, respectively). Multichannel EEG, deep learning approaches, and hold-out validation strategies generally demonstrated better diagnostic performance. Only 2 studies evaluated patient-level diagnostic performance, which was summarized qualitatively.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"conclusions\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>To our knowledge, this is the first systematic review and meta-analysis specifically focused on the diagnostic accuracy of EEG-based ML models in the detection of SA. This meta-analysis indicates that ML models based on EEG demonstrate good diagnostic accuracy in detecting SA at the segment level and show promise as tools for SA screening and clinical decision support. However, most current studies are retrospective segment-level analyses, which may overestimate the practical value of this technology in real-world clinical settings. To reliably integrate EEG-based ML models into clinical diagnostic workflows, further prospective studies incorporating full-night monitoring and patient-level validation are needed.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2196\/93378","type":"journal-article","created":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T20:03:36Z","timestamp":1785528216000},"page":"e93378-e93378","source":"Crossref","is-referenced-by-count":0,"title":["Accuracy of Machine Learning Algorithms Based on Electroencephalogram in Sleep Apnea Detection: Systematic Review and Meta-Analysis"],"prefix":"10.2196","volume":"28","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-7582-3737","authenticated-orcid":false,"given":"Xiangshuo","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-2495-566X","authenticated-orcid":false,"given":"Lulu","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6137-8005","authenticated-orcid":false,"given":"Ting","family":"Tang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-4770-8346","authenticated-orcid":false,"given":"Yuanyuan","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-7558-1109","authenticated-orcid":false,"given":"Lan","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-5430-4576","authenticated-orcid":false,"given":"Hao","family":"Cai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-8363-0258","authenticated-orcid":false,"given":"Chen","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-5081-0139","authenticated-orcid":false,"given":"Shuxiao","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8522-1560","authenticated-orcid":false,"given":"Ning","family":"Ding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4135-314X","authenticated-orcid":false,"given":"Kouying","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1010","published-online":{"date-parts":[[2026,7,31]]},"reference":[{"issue":"8","key":"R1","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1016\/S2213-2600(19)30198-5","article-title":"Estimation of the global prevalence and burden of obstructive sleep apnoea: a literature-based analysis","volume":"7","author":"Benjafield","journal-title":"Lancet Respir Med"},{"issue":"3","key":"R2","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1016\/j.ijcard.2013.08.088","article-title":"Obstructive sleep apnea and risk of cardiovascular disease and all-cause mortality: a meta-analysis of prospective cohort studies","volume":"169","author":"Wang","journal-title":"Int J Cardiol"},{"key":"R3","doi-asserted-by":"publisher","DOI":"10.1016\/j.smrv.2016.07.002","article-title":"Prevalence of obstructive sleep apnea in the general population: a systematic review","volume":"34","author":"Senaratna","journal-title":"Sleep Med Rev"},{"issue":"2","key":"R4","doi-asserted-by":"publisher","first-page":"142","DOI":"10.5935\/1984-0063.20200056","article-title":"A comprehensive review of obstructive sleep apnea","volume":"14","author":"Abbasi","journal-title":"Sleep Sci"},{"issue":"1","key":"R5","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1007\/s00408-007-9055-5","article-title":"The economic impact of obstructive sleep apnea","volume":"186","author":"AlGhanim","journal-title":"Lung"},{"issue":"2","key":"R6","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1007\/s11325-011-0524-y","article-title":"How reliable is the manual correction of the autoscoring of a level IV sleep study (ApneaLink\u2122) by an observer without experience in polysomnography?","volume":"16","author":"Nigro","journal-title":"Sleep Breath"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.1016\/j.mex.2025.103528","article-title":"Automated diagnostic method for sleep apnea and hypopnea using overnight airflow and oxygen saturation","volume":"15","author":"Yu","journal-title":"MethodsX"},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1109\/EMBC.2013.6610674","article-title":"Detection of apnoea from respiratory time series data using clinically recognizable features and kNN classification","volume":"2013","author":"Thommandram","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc"},{"key":"R9","doi-asserted-by":"crossref","unstructured":"Al-Abed M Manry M Burk JR Lucas EA Behbehani K . A method to detect obstructive sleep apnea using neural network classification of time-frequency plots of the heart rate variability. Presented at: 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society; Aug 22-26, 2007; Lyon, France. 2007.[doi: 10.1109\/IEMBS.2007.4353741]","DOI":"10.1109\/IEMBS.2007.4353741"},{"issue":"7","key":"R10","doi-asserted-by":"publisher","DOI":"10.1002\/smtd.202501242","article-title":"Conductive hydrogel-enabled electrode for scalp electroencephalography monitoring","volume":"10","author":"Ji","journal-title":"Small Methods"},{"issue":"5","key":"R11","doi-asserted-by":"publisher","first-page":"1043","DOI":"10.1007\/s10439-025-03691-5","article-title":"Sleep apnea detection using EEG: a systematic review of datasets, methods, challenges, and future directions","volume":"53","author":"Fathima","journal-title":"Ann Biomed Eng"},{"issue":"4","key":"R12","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1111\/jsr.12131","article-title":"Sleep respiratory disturbances and arousals at moderate altitude have overlapping electroencephalogram spectral signatures","volume":"23","author":"Stadelmann","journal-title":"J Sleep Res"},{"issue":"15","key":"R13","doi-asserted-by":"publisher","first-page":"3981","DOI":"10.1140\/epjs\/s11734-025-01606-y","article-title":"EEG signal processing in neurological conditions using machine learning and deep learning methods: a comprehensive review","volume":"234","author":"Jonna","journal-title":"Eur Phys J Spec Top"},{"issue":"9","key":"R14","doi-asserted-by":"publisher","DOI":"10.2196\/39452","article-title":"Enabling early obstructive sleep apnea diagnosis with machine learning: systematic review","volume":"24","author":"Ferreira-Santos","journal-title":"J Med Internet Res"},{"issue":"2","key":"R15","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1016\/j.chest.2025.04.006","article-title":"Machine listening for OSA diagnosis: a Bayesian meta-analysis","volume":"168","author":"Tan","journal-title":"Chest"},{"key":"R16","doi-asserted-by":"publisher","DOI":"10.2196\/58187","article-title":"Detection of sleep apnea using wearable AI: systematic review and meta-analysis","volume":"26","author":"Abd-Alrazaq","journal-title":"J Med Internet Res"},{"issue":"1","key":"R17","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1186\/s13643-020-01542-z","article-title":"PRISMA-S: an extension to the PRISMA statement for reporting literature searches in systematic reviews","volume":"10","author":"Rethlefsen","journal-title":"Syst Rev"},{"key":"R18","doi-asserted-by":"crossref","unstructured":"Zhang DH Zhou J Wickens JD Veale AG Hallum LE . Apnea and hypopnea event detection using EEG, EMG, and sleep stage labels in a cohort of patients with suspected sleep apnea. medRxiv. Preprint posted online on Oct 25, 2024. [doi: 10.1101\/2024.10.24.24316077]","DOI":"10.1101\/2024.10.24.24316077"},{"key":"R19","doi-asserted-by":"crossref","unstructured":"Shahnaz C Minhaz AT Ahamed S . Sub-frame based apnea detection exploiting delta band power ratio extracted from EEG signals. In: Shahnaz C Minhaz AT Ahamed ST , editors. Presented at: TENCON 2016\u20142016 IEEE Region 10 Conference; Nov 22-25, 2016; Singapore. 2016.[doi: 10.1109\/TENCON.2016.7847987]","DOI":"10.1109\/TENCON.2016.7847987"},{"issue":"1","key":"R20","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1186\/s44147-025-00821-7","article-title":"Alzheimer\u2019s diagnosis from EEG with reliable probabilities: subject-wise, leakage-free evaluation and isotonic calibration","volume":"72","author":"Shamsi","journal-title":"J Eng Appl Sci"},{"issue":"8","key":"R21","doi-asserted-by":"publisher","first-page":"529","DOI":"10.7326\/0003-4819-155-8-201110180-00009","article-title":"QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies","volume":"155","author":"Whiting","journal-title":"Ann Intern Med"},{"key":"R22","doi-asserted-by":"publisher","DOI":"10.1136\/bmj-2024-082505","article-title":"PROBAST+AI: an updated quality, risk of bias, and applicability assessment tool for prediction models using regression or artificial intelligence methods","volume":"388","author":"Moons","journal-title":"BMJ"},{"issue":"4","key":"R23","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1007\/s11065-019-09415-6","article-title":"A guide to conducting a meta-analysis with non-independent effect sizes","volume":"29","author":"Cheung","journal-title":"Neuropsychol Rev"},{"issue":"4","key":"R24","doi-asserted-by":"publisher","DOI":"10.1016\/j.imr.2023.101014","article-title":"How to understand and report heterogeneity in a meta-analysis: the difference between I-squared and prediction intervals","volume":"12","author":"Borenstein","journal-title":"Integr Med Res"},{"key":"R25","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2288-14-25","article-title":"The Hartung-Knapp-Sidik-Jonkman method for random effects meta-analysis is straightforward and considerably outperforms the standard DerSimonian-Laird method","volume":"14","author":"IntHout","journal-title":"BMC Med Res Methodol"},{"key":"R26","doi-asserted-by":"publisher","DOI":"10.1016\/j.bspc.2022.104358","article-title":"Multiple-instance learning for EEG based OSA event detection","volume":"80","author":"Cheng","journal-title":"Biomed Signal Process Control"},{"issue":"9","key":"R27","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0272167","article-title":"Detection of sleep apnea from single-channel electroencephalogram (EEG) using an explainable convolutional neural network (CNN)","volume":"17","author":"Barnes","journal-title":"PLoS One"},{"key":"R28","doi-asserted-by":"crossref","unstructured":"Mahmud T Aeioub Ansary M Mahmud TI Khan IA Fattah SA . Real time sleep apnea event detection with deep neural network. Presented at: 2019 IEEE International Conference on Biomedical Engineering, Computer and Information Technology for Health (BECITHCON); Nov 28-30, 2019; Dhaka, Bangladesh. 2019.[doi: 10.1109\/BECITHCON48839.2019.9063197]","DOI":"10.1109\/BECITHCON48839.2019.9063197"},{"key":"R29","doi-asserted-by":"crossref","unstructured":"Jiang D Ma Y Wang Y . A multi-scale parallel convolutional neural network for automatic sleep apnea detection using single-channel EEG signals. In: Wang Y Ma Y Wang Y , editors. Presented at: 2018 11th International Congress on Image and Signal Processing, BioMedical Engineering and Informatics (CISP-BMEI 2018); Oct 13-15, 2018; Beijing, China. 2018.[doi: 10.1109\/CISP-BMEI.2018.8633132]","DOI":"10.1109\/CISP-BMEI.2018.8633132"},{"issue":"5","key":"R30","doi-asserted-by":"publisher","first-page":"5346","DOI":"10.1016\/j.eswa.2010.10.022","article-title":"A new approach for estimation of obstructive sleep apnea syndrome","volume":"38","author":"Emin Tagluk","journal-title":"Expert Syst Appl"},{"issue":"3","key":"R31","doi-asserted-by":"publisher","first-page":"138","DOI":"10.4015\/S1016237206000233","article-title":"A new approach for identifying sleep apnea syndrome using wavelet transform and neural networks","volume":"18","author":"Lin","journal-title":"Biomed Eng Appl Basis Commun"},{"issue":"11","key":"R32","doi-asserted-by":"publisher","first-page":"8011","DOI":"10.1109\/JBHI.2025.3579556","article-title":"An EEG screening method for severe obstructive sleep apnea based on limited penetrable difference visibility graph and graph convolutional network","volume":"29","author":"Zhang","journal-title":"IEEE J Biomed Health Inform"},{"key":"R33","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2020.3038486","article-title":"An efficient method to detect sleep hypopnea- apnea events based on EEG signals","volume":"9","author":"Wang","journal-title":"IEEE Access"},{"key":"R34","doi-asserted-by":"crossref","unstructured":"Prucnal MA Polak AG . Analysis of features extracted from EEG epochs by discrete wavelet decomposition and Hilbert transform for sleep apnea detection. Presented at: 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC); Jul 17-21, 2018; Honolulu, HI. 2018.[doi: 10.1109\/EMBC.2018.8512201]","DOI":"10.1109\/EMBC.2018.8512201"},{"issue":"9","key":"R35","doi-asserted-by":"publisher","first-page":"1217","DOI":"10.12720\/jait.16.9.1217-1225","article-title":"Automated sleep apnea detection using CNNs: insights into the impact of FFT feature extraction on EEG signals","volume":"16","author":"Delimayanti","journal-title":"J Adv Inf Technol"},{"issue":"6","key":"R36","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1007\/s10877-015-9664-0","article-title":"Automatic detection of sleep apnea based on EEG detrended fluctuation analysis and support vector machine","volume":"29","author":"Zhou","journal-title":"J Clin Monit Comput"},{"issue":"3","key":"R37","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1049\/htl.2018.5101","article-title":"Automatic detection of sleep apnea events based on inter-band energy ratio obtained from multi-band EEG signal","volume":"6","author":"Saha","journal-title":"Healthc Technol Lett"},{"key":"R38","doi-asserted-by":"crossref","unstructured":"Gupta R Zaidi TF Farooq O . Automatic detection of sleep apnea using sub-band features from EEG signals. In: Gupta R Zaidi TF , editors. Presented at: 2020 3rd International Conference on Signal Processing and Information Security (ICSPIS); Nov 25-26, 2020; Dubai, United Arab Emirates. [doi: 10.1109\/ICSPIS51252.2020.9340133]","DOI":"10.1109\/ICSPIS51252.2020.9340133"},{"key":"R39","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2022.105211","article-title":"BI - Directional long short-term memory for automatic detection of sleep apnea events based on single channel EEG signal","volume":"142","author":"Wang","journal-title":"Comput Biol Med"},{"issue":"1","key":"R40","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-85138-0","article-title":"Classification of sleep apnea based on EEG sub-band signal characteristics","volume":"11","author":"Zhao","journal-title":"Sci Rep"},{"key":"R41","doi-asserted-by":"crossref","unstructured":"Bonner M Nikolai B Glovier Q Lamb A Gambhir A . Deep learning-based EEG analysis for sleep apnea detection. Presented at: 2024 Systems and Information Engineering Design Symposium (SIEDS); May 3-3, 2024; Charlottesville, VA. [doi: 10.1109\/SIEDS61124.2024.10534725]","DOI":"10.1109\/SIEDS61124.2024.10534725"},{"issue":"2","key":"R42","doi-asserted-by":"publisher","first-page":"431","DOI":"10.18280\/ts.380221","article-title":"Detection of sleep apnea based on the analysis of sleep stages data using single channel EEG","volume":"38","author":"Gurrala","journal-title":"Traitement du Signal"},{"key":"R43","doi-asserted-by":"publisher","DOI":"10.1016\/j.apacoust.2021.108137","article-title":"Detection of sleep apnea events using electroencephalogram signals","volume":"181","author":"Taran","journal-title":"Appl Acoust"},{"key":"R44","doi-asserted-by":"crossref","unstructured":"Khan A Biswas SK Chunka C . ESAD: expert system for apnea detection using enhanced DWT feature extraction and machine learning algorithms. In: Khan A Biswas SK Chunka C , editors. Presented at: 2023 14th International Conference on Computing Communication and Networking Technologies (ICCCNT); Jul 6-8, 2023; Delhi, India. [doi: 10.1109\/ICCCNT56998.2023.10308057]","DOI":"10.1109\/ICCCNT56998.2023.10308057"},{"key":"R45","doi-asserted-by":"publisher","DOI":"10.24425\/mms.2023.144866","article-title":"Single-channel EEG processing for sleep apnea detection and differentiation","volume":"30","author":"Prucnal","journal-title":"Metrol Meas Syst"},{"key":"R46","doi-asserted-by":"crossref","unstructured":"Wijaya RS Djamal EC Kasyidi F . Sleep apnea identification based on EEG signals using hybrid spatio-temporal deep learning. Presented at: 2024 International Conference on Computer, Control, Informatics and Its Applications (IC3INA); Oct 9-10, 2024; Bandung, Indonesia. 2024.[doi: 10.1109\/IC3INA64086.2024.10732240]","DOI":"10.1109\/IC3INA64086.2024.10732240"},{"key":"R47","doi-asserted-by":"publisher","DOI":"10.1016\/j.bspc.2022.103792","article-title":"Sparse spectrum based swarm decomposition for robust nonstationary signal analysis with application to sleep apnea detection from EEG","volume":"77","author":"Bhalerao","journal-title":"Biomed Signal Process Control"},{"key":"R48","doi-asserted-by":"crossref","unstructured":"Taran S Bajaj V Sharma D . TEO separated AM-FM components for identification of apnea EEG signals. In: Sharma D Bajaj V Sharma D , editors. Presented at: 2017 IEEE 2nd International Conference on Signal and Image Processing (ICSIP); Aug 4-6, 2017; Singapore. [doi: 10.1109\/SIPROCESS.2017.8124571]","DOI":"10.1109\/SIPROCESS.2017.8124571"},{"key":"R49","doi-asserted-by":"crossref","unstructured":"Sharifi P Fakharzadeh M . Algorithm for EEG\u2014based sleep\u2014wake classification toward sleep apnea detection. Presented at: 2025 32nd National and 10th International Iranian Conference on Biomedical Engineering (ICBME); Nov 19-20, 2025; Tabriz, Iran, Islamic Republic of. [doi: 10.1109\/ICBME68496.2025.11392421]","DOI":"10.1109\/ICBME68496.2025.11392421"},{"key":"R50","doi-asserted-by":"publisher","DOI":"10.1007\/s00034-026-03559-6","article-title":"An apnea detection method based on temporal feature variational pattern of multi-band EEG signal incorporating sleep stage information","author":"Saha","journal-title":"Circuits Syst Signal Process"},{"issue":"1","key":"R51","doi-asserted-by":"publisher","first-page":"1656","DOI":"10.47857\/irjms.2026.v07i01.08867","article-title":"Heuristic deep learning framework for EEG-based sleep apnea event classification","volume":"07","author":"Band","journal-title":"Int Res J Multidiscip Scope"},{"issue":"1","key":"R52","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2288-14-70","article-title":"Investigation of publication bias in meta-analyses of diagnostic test accuracy: a meta-epidemiological study","volume":"14","author":"van Enst","journal-title":"BMC Med Res Methodol"},{"issue":"7305","key":"R53","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1136\/bmj.323.7305.157","article-title":"Systematic reviews in health care: systematic reviews of evaluations of diagnostic and screening tests","volume":"323","author":"Deeks","journal-title":"BMJ"},{"issue":"2","key":"R54","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1159\/000489158","article-title":"Accuracy of Type III portable monitors for diagnosing obstructive sleep apnea","volume":"3","author":"Ito","journal-title":"Biomed Hub"},{"key":"R55","doi-asserted-by":"publisher","DOI":"10.1016\/j.sleep.2019.12.021","article-title":"Portable diagnosis of sleep apnea with the validation of individual event detection","volume":"69","author":"Saha","journal-title":"Sleep Med"},{"key":"R56","doi-asserted-by":"publisher","DOI":"10.3389\/fnins.2023.1059186","article-title":"Age-integrated artificial intelligence framework for sleep stage classification and obstructive sleep apnea screening","volume":"17","author":"Kang","journal-title":"Front Neurosci"},{"issue":"1","key":"R57","doi-asserted-by":"publisher","DOI":"10.3390\/clockssleep7010001","article-title":"Changes in the spatial structure of synchronization connections in EEG during nocturnal sleep apnea","volume":"7","author":"Zhuravlev","journal-title":"Clocks Sleep"},{"key":"R58","doi-asserted-by":"crossref","unstructured":"Prucnal MA Polak AG . Effectiveness of sleep apnea detection based on one vs. two symmetrical EEG channels. In: Prucnal MA Polak AG , editors. Presented at: 2019 41st Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC); Jul 23-27, 2019; Berlin, Germany. 2019.[doi: 10.1109\/EMBC.2019.8856632]","DOI":"10.1109\/EMBC.2019.8856632"},{"key":"R59","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2022.118994","article-title":"Robust learning from corrupted EEG with dynamic spatial filtering","volume":"251","author":"Banville","journal-title":"Neuroimage"},{"issue":"12","key":"R60","doi-asserted-by":"publisher","DOI":"10.3390\/brainsci14121201","article-title":"Comparative analysis of single-channel and multi-channel classification of sleep stages across four different data sets","volume":"14","author":"Zhang","journal-title":"Brain Sci"},{"key":"R61","doi-asserted-by":"publisher","DOI":"10.1109\/TIM.2025.3556900","article-title":"A tale of single-channel electroencephalogram: devices, datasets, signal processing, applications, and future directions","volume":"74","author":"Li","journal-title":"IEEE Trans Instrum Meas"},{"issue":"19","key":"R62","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.2413789122","article-title":"Cortical signatures linked to behavior quantitatively track arousal levels","volume":"122","author":"Gao","journal-title":"Proc Natl Acad Sci U S A"},{"key":"R63","doi-asserted-by":"publisher","DOI":"10.1016\/j.smrv.2022.101743","article-title":"Portable evaluation of obstructive sleep apnea in adults: a systematic review","volume":"68","author":"Khor","journal-title":"Sleep Med Rev"},{"key":"R64","doi-asserted-by":"publisher","DOI":"10.3389\/fnins.2020.00310","article-title":"Sleep electroencephalographic response to respiratory events in patients with moderate sleep apnea-hypopnea syndrome","author":"Zhou","journal-title":"Front Neurosci"},{"issue":"18","key":"R65","doi-asserted-by":"publisher","DOI":"10.3390\/s25185690","article-title":"Transparent EEG analysis: leveraging autoencoders, Bi-LSTMs, and SHAP for improved neurodegenerative diseases detection","volume":"25","author":"Mouazen","journal-title":"Sensors (Basel)"},{"issue":"5","key":"R66","doi-asserted-by":"publisher","first-page":"597","DOI":"10.5664\/jcsm.2172","article-title":"Rules for scoring respiratory events in sleep: update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine","volume":"8","author":"Berry","journal-title":"J Clin Sleep Med"},{"issue":"1","key":"R67","doi-asserted-by":"publisher","DOI":"10.1186\/s41606-025-00145-8","article-title":"Multi-night home testing with portable EEG shows improvement in sleep quality after starting CPAP for obstructive sleep apnoea","volume":"9","author":"Lee","journal-title":"Sleep Sci Pract"},{"issue":"1","key":"R68","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-024-53827-1","article-title":"Validation of sleep-staging accuracy for an in-home sleep electroencephalography device compared with simultaneous polysomnography in patients with obstructive sleep apnea","volume":"14","author":"Seol","journal-title":"Sci Rep"},{"issue":"7","key":"R69","doi-asserted-by":"publisher","DOI":"10.1093\/sleep\/zsab030","article-title":"Metrics of sleep apnea severity: beyond the apnea-hypopnea index","volume":"44","author":"Malhotra","journal-title":"Sleep"},{"issue":"2","key":"R70","doi-asserted-by":"publisher","DOI":"10.1212\/CPJ.0000000000200264","article-title":"The cost of after-hour electroencephalography","volume":"14","author":"Ney","journal-title":"Neurol Clin Pract"},{"issue":"4","key":"R71","doi-asserted-by":"publisher","first-page":"1554","DOI":"10.1038\/s41440-025-02544-x","article-title":"Enhancing interpretability and clinical integration of machine learning models for home blood pressure monitoring adherence","volume":"49","author":"Yu","journal-title":"Hypertens Res"},{"issue":"1","key":"R72","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1080\/13696998.2021.1887877","article-title":"Modeling the economic value of ceribell rapid response EEG in the inpatient hospital setting","volume":"24","author":"Ney","journal-title":"J Med Econ"},{"issue":"1","key":"R73","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1038\/s41591-021-01614-0","article-title":"AI in health and medicine","volume":"28","author":"Rajpurkar","journal-title":"Nat Med"},{"key":"R74","doi-asserted-by":"publisher","DOI":"10.1016\/j.imu.2023.101286","article-title":"Application of explainable artificial intelligence in medical health: a systematic review of interpretability methods","volume":"40","author":"Band","journal-title":"Inform Med Unlocked"},{"key":"R75","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbi.2020.103611","article-title":"Detection of calibration drift in clinical prediction models to inform model updating","volume":"112","author":"Davis","journal-title":"J Biomed Inform"}],"container-title":["Journal of Medical Internet Research"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T20:03:45Z","timestamp":1785528225000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jmir.org\/2026\/1\/e93378"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,31]]},"references-count":75,"URL":"https:\/\/doi.org\/10.2196\/93378","relation":{},"ISSN":["1438-8871"],"issn-type":[{"value":"1438-8871","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,31]]},"article-number":"v28i8e93378"}}