{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T19:17:50Z","timestamp":1787944670198,"version":"build-2784847793"},"reference-count":23,"publisher":"JMIR Publications Inc.","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JMIR Nursing"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec sec-type=\"background\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Monitoring of vital signs is a critical component of nursing care, facilitating the early detection of complications, enabling the observation of the progression of health status, and providing a foundation for diagnosis and therapeutic decision-making. It is instrumental in ensuring quality of care. Contactless measurement methods, such as radar-based sensors, have the potential to enable continuous monitoring of respiration, heart rate, and bed activity without disturbing or stressing vulnerable patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"objective\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>The study investigates the feasibility, usability, acceptance, and implementation of a contactless digital vital-signs monitoring system. The objective is to ascertain the suitability of the device for incorporation into the workflow of nursing personnel and to assess implementation factors in an inpatient setting. Additionally, the study examines user acceptance and satisfaction among nursing staff.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A total of 13 nursing staff members from geriatric and dialysis departments participated in this mixed methods pilot study. Following the installation of the technology, the participants underwent a 30-minute training period to become acquainted with its operation. Thereafter, the system was subjected to a 4-week trial period. Quantitative data were collected at 3 points in time using the Technology Usage Inventory and the System Usability Scale. Furthermore, measurement protocols were evaluated to compare the time required for the standard and contactless measurement methods. Qualitative data were collected subsequent to the conclusion of the trial through the implementation of focus group interviews. Ethical approval and informed consent were obtained.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The study results suggest that the average intention to use among the study participants (n=13) reached a relatively high level after 4 weeks (mean 85.5, SD 107.7). However, variation was observed when the 2 nursing wards were considered separately (geriatrics: 28.4 vs dialysis 199.8). The monitoring system was evaluated based on the System Usability Scale, which yielded a mean score of 74.5 (SD 10.5), indicating good usability. The nurses reported a perceived enhancement in their sense of security and monitoring oversight during routine care. Additionally, potential time savings were observed due to a reduction in disruptions to established processes. However, compared with conventional real-time monitoring, disadvantages were identified and technical requirements were defined.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"conclusions\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The use of contactless measurement in the assessment of vital signs holds considerable promise for enhancing the efficacy of nursing care, particularly in contexts where manual measurements have been the prevailing standard. In order to further explore technical capabilities in a nursing context, additional research needs to be conducted.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2196\/93624","type":"journal-article","created":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T18:42:52Z","timestamp":1787942572000},"page":"e93624-e93624","source":"Crossref","is-referenced-by-count":0,"title":["Radar-Based Contactless Monitoring in Different Inpatient Nursing Care Settings: Mixed Methods Feasibility Study"],"prefix":"10.2196","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8736-025X","authenticated-orcid":false,"given":"Madeleine","family":"Ritter-Herschbach","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3110-2379","authenticated-orcid":false,"given":"Sebastian","family":"Hofstetter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-1755-4467","authenticated-orcid":false,"given":"Dominik","family":"Behr","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-8331-6008","authenticated-orcid":false,"given":"Melina","family":"Hager","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-1921-2946","authenticated-orcid":false,"given":"Burkhard","family":"Mueller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1533-6717","authenticated-orcid":false,"given":"Patrick","family":"Jahn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1010","published-online":{"date-parts":[[2026,8,28]]},"reference":[{"issue":"10","key":"R1","doi-asserted-by":"publisher","first-page":"806","DOI":"10.1111\/ijcp.12846","article-title":"Effectiveness of continuous or intermittent vital signs monitoring in preventing adverse events on general wards: a systematic review and meta-analysis","volume":"70","author":"Cardona-Morrell","journal-title":"Int J Clin Pract"},{"issue":"19","key":"R2","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.12968\/bjon.2014.23.19.1036","article-title":"The National Early Warning Score in practice: a reflection","volume":"23","author":"Day","journal-title":"Br J Nurs"},{"key":"R3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijnurstu.2018.04.013","article-title":"The impact of continuous versus intermittent vital signs monitoring in hospitals: a systematic review and narrative synthesis","volume":"84","author":"Downey","journal-title":"Int J Nurs Stud"},{"issue":"7","key":"R4","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1007\/s00391-023-02228-6","article-title":"Delirium and sleep disturbances-a narrative review","volume":"56","author":"Kuhlmann","journal-title":"Z Gerontol Geriatr"},{"issue":"11","key":"R5","doi-asserted-by":"publisher","DOI":"10.3390\/medicina57111244","article-title":"Delirium and cognitive impairment as predisposing factors of COVID-19 infection in neuropsychiatric patients: a narrative review","volume":"57","author":"Fabrazzo","journal-title":"Medicina (Kaunas)"},{"key":"R6","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijnurstu.2018.09.014","article-title":"Vital sign monitoring following stroke associated with 90-day independence: a secondary analysis of the QASC cluster randomized trial","volume":"89","author":"Middleton","journal-title":"Int J Nurs Stud"},{"issue":"2","key":"R7","doi-asserted-by":"publisher","first-page":"855","DOI":"10.1007\/s13555-025-01638-1","article-title":"Geriatric psychodermatology: current concepts and therapeutic strategies","volume":"16","author":"Kiser","journal-title":"Dermatol Ther (Heidelb)"},{"issue":"3","key":"R8","doi-asserted-by":"publisher","DOI":"10.3390\/s24031003","article-title":"Systematic literature review regarding heart rate and respiratory rate measurement by means of radar technology","volume":"24","author":"Liebetruth","journal-title":"Sensors (Basel)"},{"issue":"15","key":"R9","doi-asserted-by":"publisher","DOI":"10.3390\/s25154792","article-title":"Contactless vital sign monitoring: a review towards multi-modal multi-task approaches","volume":"25","author":"Hassanpour","journal-title":"Sensors (Basel)"},{"key":"R10","unstructured":"Shifron R . Neteera. 2024. URL: https:\/\/www.neteera.com\/product [Accessed 28-11-2024]"},{"issue":"1","key":"R11","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1177\/1525822X05282260","article-title":"Using mixed-methods sequential explanatory design: from theory to practice","volume":"18","author":"Ivankova","journal-title":"Field methods"},{"key":"R12","unstructured":"Tashakkori A Teddlie C . Handbook of Mixed Methods in the Social & Behavioral Sciences. SAGE Publications; 2002. ISBN: 9780761920731"},{"issue":"2","key":"R13","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1258\/jhsrp.2007.007074","article-title":"The quality of mixed methods studies in health services research","volume":"13","author":"O\u2019Cathain","journal-title":"J Health Serv Res Policy"},{"key":"R14","unstructured":"Kothgassner OD Felnhofer A Hauk N et al. TUI: technology usage inventory manual. FFG Forschungsf\u00f6rderungsgesellschaft; 2012. URL: https:\/\/ucrisportal.univie.ac.at\/en\/publications\/tui-technology-usage-inventory-manual\/ [Accessed 22-08-2026]"},{"key":"R15","doi-asserted-by":"crossref","unstructured":"Brooke J . SUS: a quick and dirty usability scale. In: Jordan PW Thomas B McClelland IL Weerdmeester B , editors. Usability Evaluation In Industry. CRC Press; 1996. [doi: 10.1201\/9781498710411-35]","DOI":"10.1201\/9781498710411-35"},{"key":"R16","doi-asserted-by":"crossref","unstructured":"Kuckartz U R\u00e4diker S . Analyzing Qualitative Data with MAXQDA Text, Audio, and Video. Springer International Publishing; 2019. ISBN: 978-3-030-15670-1","DOI":"10.1007\/978-3-030-15671-8_1"},{"key":"R17","doi-asserted-by":"publisher","DOI":"10.2196\/64616","article-title":"Factors influencing the implementation and adoption of digital nursing technologies: systematic umbrella review","volume":"27","author":"Walzer","journal-title":"J Med Internet Res"},{"issue":"1","key":"R18","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1177\/1474515117721561","article-title":"The effect of nurse-to-patient ratios on nurse-sensitive patient outcomes in acute specialist units: a systematic review and meta-analysis","volume":"17","author":"Driscoll","journal-title":"Eur J Cardiovasc Nurs"},{"issue":"8","key":"R19","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pdig.0000949","article-title":"Nurses\u2019 experiences with inhospital continuous monitoring of vital signs in general wards: a systematic review","volume":"4","author":"van Zeist-de Jonge","journal-title":"PLOS Digit Health"},{"issue":"12","key":"R20","doi-asserted-by":"publisher","first-page":"1743","DOI":"10.1001\/jama.1988.03410120089033","article-title":"The quality of care: how can it be assessed?","volume":"260","author":"Donabedian","journal-title":"JAMA"},{"issue":"3","key":"R21","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1024\/1012-5302\/a001063","article-title":"Practical training for nursing and allied health workers for a reflective approach to digitalization processes: a mixed methods study [Article in German]","volume":"39","author":"Kraft","journal-title":"Pflege"},{"issue":"1","key":"R22","doi-asserted-by":"publisher","DOI":"10.1186\/s11556-021-00266-w","article-title":"Sensor-based fall risk assessment in older adults with or without cognitive impairment: a systematic review","volume":"18","author":"Bezold","journal-title":"Eur Rev Aging Phys Act"},{"key":"R23","doi-asserted-by":"publisher","DOI":"10.2196\/54083","article-title":"Integrating digital assistive technologies into care processes: mixed methods study","volume":"10","author":"Hofstetter","journal-title":"JMIR Med Educ"}],"container-title":["JMIR Nursing"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T18:42:53Z","timestamp":1787942573000},"score":1,"resource":{"primary":{"URL":"https:\/\/nursing.jmir.org\/2026\/1\/e93624"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,28]]},"references-count":23,"URL":"https:\/\/doi.org\/10.2196\/93624","relation":{},"ISSN":["2562-7600"],"issn-type":[{"value":"2562-7600","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,28]]},"article-number":"v9i10e93624"}}