{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,12,18]],"date-time":"2022-12-18T05:34:11Z","timestamp":1671341651983},"reference-count":37,"publisher":"Tokyo Dental College","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Bull. Tokyo Dent. Coll."],"published-print":{"date-parts":[[2021]]},"DOI":"10.2209\/tdcpublication.2020-0028","type":"journal-article","created":{"date-parts":[[2021,2,14]],"date-time":"2021-02-14T22:10:00Z","timestamp":1613340600000},"page":"15-26","source":"Crossref","is-referenced-by-count":0,"title":["Influence of Tooth Mold Materials in Composite Resin CAD\/CAM Crown Destructive Test"],"prefix":"10.2209","volume":"62","author":[{"given":"Syuntaro","family":"Nomoto","sequence":"first","affiliation":[{"name":"Department of Fixed Prosthodontics, Tokyo Dental College"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomotoshi","family":"Masuda","sequence":"additional","affiliation":[{"name":"Department of Fixed Prosthodontics, Tokyo Dental College"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toru","family":"Sato","sequence":"additional","affiliation":[{"name":"Tokyo Dental Junior College"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mariko","family":"Yumoto","sequence":"additional","affiliation":[{"name":"Department of Fixed Prosthodontics, Tokyo Dental College"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gen","family":"Kuroishi","sequence":"additional","affiliation":[{"name":"Department of Fixed Prosthodontics, Tokyo Dental College"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yosuke","family":"Maeda","sequence":"additional","affiliation":[{"name":"Department of Fixed Prosthodontics, Tokyo Dental College"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mizuho","family":"Hirano","sequence":"additional","affiliation":[{"name":"Department of Fixed Prosthodontics, Tokyo Dental College"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hideshi","family":"Sekine","sequence":"additional","affiliation":[{"name":"Department of Fixed Prosthodontics, Tokyo Dental College"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1039","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1) Adriana OC, Greciana B, Marcelo G, Pascal M (2014) Fatigue resistance of CAD\/CAM complete crowns with a simplified cementation process. J Prosthet Dent 111: 310-317.","DOI":"10.1016\/j.prosdent.2013.09.020"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2) Al-Assaf K, Chakmakchi M, Palaghias G, Karanika-kouma A, Eliades G (2007) Interfacial characteristics of adhesive luting resins and composite with dentin. Dent Mater 23: 829-839.","DOI":"10.1016\/j.dental.2006.06.023"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3) Andrew CJ, Antheunis V, Daranee T, Swati A (2014) Fracture strength of CAD\/CAM composite and composite-ceramic occlusal veneers. J Prosthodont Res 58: 107-114.","DOI":"10.1016\/j.jpor.2014.01.001"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4) Attia A, Abdelaziz KM, Freitag S, Kern M (2006) Fracture load of composite resin and feldspathic all-ceramic CAD\/CAM crowns. J Prosthet Dent 95: 117-123.","DOI":"10.1016\/j.prosdent.2005.11.014"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5) Awada A, Nathanson D (2015) Mechanical properties of resin-ceramic CAD\/CAM restorative material. J Prosthet Dent 114: 587-593.","DOI":"10.1016\/j.prosdent.2015.04.016"},{"key":"6","unstructured":"6) Chang YH, Lin WH, Kuo WC, Chang CY, Lin CL (2009) Mechanical interactions of cuspalcoverage designs and cement thickness in a cusp-replacing ceramic premolar restoration: a finite element study. Clin Oral Investing 47: 367-374."},{"key":"7","doi-asserted-by":"crossref","unstructured":"7) Fahad AA, Neveen MA, Aws SA, Hala AB, Nadim Z, Baba AB (2017) Effect of aging regimens on resin nanoceramic chairside CAD\/CAM materials. J Prosthodont 26: 432-439.","DOI":"10.1111\/jopr.12408"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8) Fatma AS, Hui T, Marina K, Malvin NJ, Van PT, Niek JO, Yu Z (2016) Fatigue resistance of CAD\/CAM resin composite molar crowns. Dent Mater 32: 499-509.","DOI":"10.1016\/j.dental.2015.12.005"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9) Jonathon SE, Andrew CJ, Daranee T, Antheunis V (2015) Fracture strength of ultrathin occlusal veneer restorations made from CAM\/CAM composite or hybrid ceramic materials. Oral Sci Int 12: 53-58.","DOI":"10.1016\/S1348-8643(15)00017-8"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10) Kikuchi M, Korioth TWP, Hannam AG (1997) The association among occlusal contacts, clenching effort, and bite force distribution in man. J Dent Res 76: 1316-1325.","DOI":"10.1177\/00220345970760061201"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11) Lauvahutanon S, Takahashi H, Shiozawa M, Iwasaki N, Asakawa Y, Oki M, Werner JF, Arksornnukit M (2014) Mechanical properties of composite resin blocks for CAD\/CAM. Dent Mater J 33: 705-710.","DOI":"10.4012\/dmj.2014-208"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12) Masuda T, Nomoto S, Sato T, Kanda Y, Sakai T, Tsuyuki Y (2019) Effect of differences in axial thickness and types of cement on fracture resistance in composite resin CAD\/CAM crowns. Bull Tokyo Dent Coll 60: 17-27.","DOI":"10.2209\/tdcpublication.2018-0022"},{"key":"13","unstructured":"13) Mesmar S, Ruse ND (2017) Interfacial fracture toughness of adhesive resin cement lithium-disilicate\/resin-composite blocks. J Prosthodont 28:e243-251."},{"key":"14","unstructured":"14) Murahara S, Uenodan A, Sakoguchi K, Minesaki Y, Tanaka T, Minami H (2017) A study on the fracture resistance of CAD\/CAM hybrid resin crowns to cyclic impact. Settyaku Shigaku 35: 1-5. (in Japanese)"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15) Nakamura K, Harada A, Inagaki R, Kanno T, Niwano Y, Milleding P, Ortengren U (2015) Fracture resistance of monolithic zirconia molar crowns with reduced thickness. Acta Odontol Scand 73: 602-608.","DOI":"10.3109\/00016357.2015.1007479"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16) Nomoto S, Matsunaga S, Ide Y, Abe S, Takahashi T, Saito F, Sato T (2006) Stress distribution in maxillary alveolar ridge according to Finite Element Analysis using micro-CT. Bull Tokyo Dent Coll 47: 149-156.","DOI":"10.2209\/tdcpublication.47.149"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17) Nomoto S, Matsunaga S, Sato T, Yotsuya M, Abe S (2015) Basic finite element analysis of para-periodontal ligament in all-ceramic zirconia fixed partial denture. Bull Tokyo Dent Coll 56: 215-222.","DOI":"10.2209\/tdcpublication.56.215"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18) Ohlmann B, Gruber R, Eickemeyer G, Rammelsberg P (2008) Optimizing preparation design for metal-free composite resin crowns. J Prosthet Dent 100: 211-219.","DOI":"10.1016\/S0022-3913(08)60180-8"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19) &#214;zcan M, Mese A (2012) Adhesion of conventional and simplified resin-based luting cements to superficial and deep dentine. Clin Oral Investig 16: 1081-1088.","DOI":"10.1007\/s00784-011-0594-z"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20) Pascal M, Adriana OC, Greciana B, Marcelo G (2015) Fatigue resistance of ultrathin CAD\/CAM composite crowns with a simplified cementation process. J Prosthet Dent 114: 574-579.","DOI":"10.1016\/j.prosdent.2015.04.014"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21) Pascal M, Alena K (2009) Thickness of CAD\/CAM composite resin overlays influences fatigue resistance of endodontically treated premolars. Dent Mater 25: 1264-1268.","DOI":"10.1016\/j.dental.2009.05.007"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22) Pascal M, Luis HS, Hamilton PM, Luiz NB (2010) In vitro fatigue resistance of CAD\/CAM composite resin and ceramic posterior occlusal veneers. J Prosthet Dent 104: 149-157.","DOI":"10.1016\/S0022-3913(10)60111-4"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23) Rammelsberg P, Eickemeyer G, Erdelt K, Pospiech P (2000) Fracture resistance of posterior metal-free polymer crown. J Prosthet Dent 84: 303-308.","DOI":"10.1067\/mpr.2000.108068"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24) Rohr N, Brunner S, M&#228;rtin S, Fischer J (2018) Influence of cement type and ceramic primer on retention of polymer-infiltrated ceramic crowns to a one-piece zirconia implant. J Prosthet Dent 119: 138-145.","DOI":"10.1016\/j.prosdent.2017.02.002"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25) Rosentritt M, Preis V, Behr M, Hahnel S (2017) Influence of preparation, fitting, and cementation on the vitro performance and fracture resistance of CAD\/CAM crowns. J Dent 65: 70-75.","DOI":"10.1016\/j.jdent.2017.07.006"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26) Sakoguchi K, Minami M (2013) Evaluation of fracture resistance of indirect composite resin crowns by cyclic impact test: influence of crown and abutment materials. Dent Mater J 32: 433-440.","DOI":"10.4012\/dmj.2012-313"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27) Seydler B, Rues S, Muller D, Schmitter M (2014) In vitro fracture load of monolithic lithium disilicate ceramic molar crowns with different wall thicknesses. Clin Oral Investing 18: 1165-1171.","DOI":"10.1007\/s00784-013-1062-8"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28) Shahrbaf S, vanNoort R, Mirzakouchaki B, Ghassemieh E, Martin N (2014) Fracture strength of machined ceramic crowns as a function of tooth preparation design and the elastic modulus of the cement. Dent Mater 30: 234-241.","DOI":"10.1016\/j.dental.2013.11.010"},{"key":"29","doi-asserted-by":"crossref","unstructured":"29) Shinya A, Miura S, Koizumi H, Hikita K, Mine A (2017) Current status and future prospect of CAD\/CAM composite crown. Nihon Hotetsu Sika Gakkai Zasshi 9: 1-15. (in Japanese)","DOI":"10.2186\/ajps.9.1"},{"key":"30","doi-asserted-by":"crossref","unstructured":"30) Sun W, Cai Q, Li P, Deng X, Wei Y, Xu MM, Yang X (2010) Post-draw PAN-PMMA nanofiber reinforced and toughened Bis-GMA dental restorative composite. Dent Mater 26: 873-880.","DOI":"10.1016\/j.dental.2010.03.022"},{"key":"31","unstructured":"31) Suzuki S, Sakoh M, Shiba A, Sakai K, Miyamoto R (1989) Effects of adhesive resin cement on durability of resin jacket crown. Settyaku Shigaku 7: 257-266. (in Japanese)"},{"key":"32","doi-asserted-by":"crossref","unstructured":"32) Tagami A, Takahashi R, Nikaido T, Tagami J (2017) The effect of curing conditions on the dentin bond strength of two dual-cure resin cements. J Prosthodont Res 61: 312-418.","DOI":"10.1016\/j.jpor.2016.12.012"},{"key":"33","doi-asserted-by":"crossref","unstructured":"33) Tsuyuki Y, Takemoto S, Sato T, Nomoto S, Yotsuya M, Koshihara T, Yoshinari M (2018) Effect of occlusal groove on abutment, crown thickness, and cement-type on fracture load of monolithic zirconia crowns. Dent Mater J 37: 843-850.","DOI":"10.4012\/dmj.2017-350"},{"key":"34","doi-asserted-by":"crossref","unstructured":"34) Vafaee F, Firooz F, Heidari B, Khoshhal M, Fotovat F, Allahbakhshi H (2017) A comparative study of flexural strength and fatigue resistance of 2 nanoceramic composite resin CAD\/CAM blocks (Lava Ultimate and Vita Enamic) and a lithium disilicate glass ceramic (IPS e. max CAD). Biomed Pharmacol J 10: 51-58.","DOI":"10.13005\/bpj\/1080"},{"key":"35","unstructured":"35) Wiskott HW, Belser UC, Scherrer SS (1999) The effect of film thickness and surface texture on the resistance of cemented extracoronal restorations lateral fatigue lording. Int J Prosthodont 12: 255-262."},{"key":"36","doi-asserted-by":"crossref","unstructured":"36) Yoshida Y (2012) Nano-interfatial analysis for tooth bonding. Nihon Hotetsu Sika Gakkai Zasshi 4: 353-363. (in Japanese)","DOI":"10.2186\/ajps.4.353"},{"key":"37","doi-asserted-by":"crossref","unstructured":"37) Zimmermann M, Egli G, Zaruba M, Mehl A (2017) Influence of material thickness on fractural strength of CAD\/CAM fabricated ceramic crowns. Dent Mater J 36: 778-783.","DOI":"10.4012\/dmj.2016-296"}],"container-title":["The Bulletin of Tokyo Dental College"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/tdcpublication\/62\/1\/62_2020-0028\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T10:39:19Z","timestamp":1671273559000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/tdcpublication\/62\/1\/62_2020-0028\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021]]},"references-count":37,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.2209\/tdcpublication.2020-0028","relation":{},"ISSN":["0040-8891"],"issn-type":[{"value":"0040-8891","type":"print"}],"subject":[],"published":{"date-parts":[[2021]]}}}