{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,6,24]],"date-time":"2024-06-24T01:30:46Z","timestamp":1719192646140},"reference-count":40,"publisher":"Tokyo Dental College","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Bull. Tokyo Dent. Coll."],"published-print":{"date-parts":[[2003]]},"DOI":"10.2209\/tdcpublication.44.159","type":"journal-article","created":{"date-parts":[[2006,1,31]],"date-time":"2006-01-31T05:57:19Z","timestamp":1138687039000},"page":"159-167","source":"Crossref","is-referenced-by-count":3,"title":["CLINICAL VALIDITY OF THE INTERACTIVE AND LOW-DOSE THREE-DIMENSIONAL DENTO-ALVEOLAR IMAGING SYSTEM, TUNED-APERTURE COMPUTED TOMOGRAPHY"],"prefix":"10.2209","volume":"44","author":[{"given":"YOSHIHIKO","family":"HAYAKAWA","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"KAZUHIRO","family":"YAMAMOTO","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"YUJI","family":"KOUSUGE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"NORIO","family":"KOBAYASHI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MAMORU","family":"WAKOH","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"HIROSHI","family":"SEKIGUCHI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MASASHI","family":"YAKUSHIJI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ALLAN G.","family":"FARMAN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1039","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1) Abreu, M., Jr., Tyndall, D.A. and Ludlow, J.B. (2001). Generation of TACT image slices using different reconstruction algorithms: Effects on natural caries detection. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 92, 576-581.","DOI":"10.1067\/moe.2001.119146"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2) Abreu, M., Jr., Tyndall, D.A., Ludlow, J.B. and Nortje, C.J. (2001). The effect of the number of iterative restorations on tuned aperture computed tomography for approximal caries detection. Dentomaxillofac Radiol 30, 325-329.","DOI":"10.1038\/sj.dmfr.4600636"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3) Abreu, M., Jr., Tyndall, D.A., Ludlow, J.B. and Nortje, C.J. (2002). Influence of the number of basis images and projection array on caries detection using tuned aperture computed tomography (TACT). Dentomaxillofac Radiol 31, 24-31.","DOI":"10.1038\/sj.dmfr.4600656"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4) Abreu, M., Jr., Tyndall, D.A., Platin, E., Ludlow, J.B. and Philips, C. (1999). Two- and three-dimensional imaging modalities for detection of caries: A comparison between film, digital radiography and tuned aperture computed tomography (TACT). Dentomaxillofac Radiol 28, 152-157.","DOI":"10.1038\/sj.dmfr.4600430"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5) Cavalcanti, M.G., Ruprecht, A. and Vannier, M.W. (2002). 3D volume rendering using multislice CT for dental implants. Dentomaxillofac Radiol 31, 218-223.","DOI":"10.1038\/sj.dmfr.4600701"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6) Chai-U-Dom, O., Ludlow, J.B., Tyndall, D.A. and Webber, R.L. (2001). Detection of simulated periodontal bone gain by digital subtraction radiography with tuned-aperture computed tomography. The effect of angular disparity. Dentomaxillofac Radiol 30, 92-97.","DOI":"10.1038\/sj.dmfr.4600579"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7) Chai-U-Dom, O., Ludlow, J.B., Tyndall, D.A. and Webber, R.L. (2002). Comparison of conventional and TACT (Tuned Aperture Computed Tomography) digital subtraction radiography in detection of pericrestal bonegain. J Periodontal Res 37, 147-153.","DOI":"10.1034\/j.1600-0765.2002.00032.x"},{"key":"8","unstructured":"8) Fahey, F.H., Grow, K.L., Webber, R.L., Harkness, B.A., Bayram, E. and Hemler, P.F. (2001). Emission tuned-aperture computed tomography: A novel approach to scintimammography. J Nucl Med 42, 1121-1127."},{"key":"9","doi-asserted-by":"crossref","unstructured":"9) Farman, A.G., Scheetz, J.P., Eleazer, P.D., Edge, M.J., Morant, R.D., Limrachtamorn, S. and Yamamoto, K. (2001). Tuned-aperture computed tomography accuracy in tomosynthetic assessment for dental procedures. In The Proceedings of the 15th International Congress of Computer Assisted Radiology and Surgery. (H.U., Lemke, M.W., Vannier, K., Inamura, A.G., Farman and K. Doi eds.) pp.654-658, Springer, Berlin.","DOI":"10.1016\/S0531-5131(01)00113-3"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10) Hashimoto, K., Arai, Y., Iwai, K., Araki, M., Kawashima, S. and Terakado, M. (2003). Comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 95, 371-377.","DOI":"10.1067\/moe.2003.120"},{"key":"11","unstructured":"11) Hayakawa, Y., Yamamoto, K., Kobayashi, N., Kousuge, Y., Wakoh, M. and Farman, A.G. (2002). Clinical trial of small flat-panel detector in dento-alveolar imaging. Innervision 18(4), 88-91. (in Japanese)"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12) Heiland, M., Schulze, D., Adam, G. and Schmelzle, R. (2003). 3D-imaging of the facial skeleton with an isocentric mobile C-arm system (Siremobil Iso-C3D). Dentomaxillofac Radiol 32, 21-25.","DOI":"10.1259\/dmfr\/80391180"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13) Lehmann, T.M., Hemler, P.F. and Webber, R.L. (2002). Virtual radiographs computed from TACT volume data as a gold standard for image registration prior to subtraction. Dentomaxillofac Radiol 31, 187-192.","DOI":"10.1038\/sj.dmfr.4600682"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14) Liang, H., Tyndall, D.A., Ludlow, J.B. and Lang, L.A. (1999). Cross-sectional presurgical implant imaging using tuned aperture computed tomography (TACT). Dentomaxillofac Radiol 28, 232-237.","DOI":"10.1038\/sj.dmfr.4600451"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15) Liang, H., Tyndall, D.A., Ludlow, J.B., Lang, L.A. and Nunn, M.E. (2001). Accuracy of mandibular cross-sectional imaging with tuned-aperture computed tomography (TACT), iteratively reconstructed TACT, and multidirectional, linear, and transverse panoramic tomography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 91, 594-602.","DOI":"10.1067\/moe.2001.112157"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16) Linnenbrugger, N.I., Webber, R.L. and Lehmann, T.M. (2002). Implementation of a generalized TACT algorithm for arbitrary source-object distances. Dentomaxillofac Radiol 31, 249-256.","DOI":"10.1038\/sj.dmfr.4600703"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17) Morant, R.D., Eleazer, P.D., Scheetz, J.P. and Farman, A.G. (2001). Array-projection geometry and depth discrimination with Tuned-Aperture Computed Tomography for assessing the relationship between tooth roots and the inferior alveolar canal. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 91, 252-259.","DOI":"10.1067\/moe.2001.112597"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18) Nair, M.K., Nair, U.P., Grondahl, H.G. and Webber, R.L. (2002). Accuracy of tuned aperture computed tomography in the diagnosis of radicular fractures in non-restored maxillary anterior teeth-An in vitro study. Dentomaxillofac Radiol 31, 299-304.","DOI":"10.1038\/sj.dmfr.4600712"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19) Nair, M.K., Nair, U.D.P., Grondahl, H.G., Webber, R.L. and Wallace, J.A. (2001). Detection of artificially induced vertical radicular fractures using tuned aperture computed tomography. Eur J Oral Sci 109, 375-379.","DOI":"10.1034\/j.1600-0722.2001.00085.x"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20) Nair, M.K., Seyedain, A., Agarwal, S., Webber, R.L., Nair, U.P., Piesco, N.P., Mooney, M.P. and Grondahl, H.G. (2001). Tuned aperture computed tomography to evaluate osseous healing. J Dent Res 80, 1621-1624.","DOI":"10.1177\/00220345010800070501"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21) Nair, M.K., Seyedain, A., Webber, R.L., Nair, U.P., Piesco, N.P., Agarwal, S., Mooney, M.P. and Grondahl, H.G. (2001). Fractal analyses of osseous healing using tuned aperture computed tomography images. Eur Radiol 11, 1510-1515.","DOI":"10.1007\/s003300000773"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22) Nair, M.K., Tyndall, D.A., Ludlow, J.B. and May, K. (1998). Tuned aperture computed tomography and detection of recurrent caries. Caries Res 32, 23-30.","DOI":"10.1159\/000016426"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23) Ramesh, A., Ludlow, J.B., Webber, R.L., Tyndall, D.A. and Paquette, D. (2002). Evaluation of tuned-aperture computed tomography in the detection of simulated periodontal defects. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 93, 341-349.","DOI":"10.1067\/moe.2002.120057"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24) Suryanarayanan, S., Karellas, A., Vedantham, S., Glick, S.J., D&rsquo;Orsi, C.J., Baker, S.P. and Webber, R.L. (2000). Comparison of tomosynthesis methods used with digital mammography. Acad Radiol 7, 1085-1097.","DOI":"10.1016\/S1076-6332(00)80061-6"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25) Tyndall, D.A., Clifton, T.L., Webber, R.L., Ludlow, J.B. and Horton, R.A. (1997). TACT imaging of primary caries. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 84, 214-225.","DOI":"10.1016\/S1079-2104(97)90072-X"},{"key":"26","unstructured":"26) Webber, R.L. (1999). The future of dental imaging. Where do we go from here? Dentomaxillofac Radiol 28, 62-65."},{"key":"27","doi-asserted-by":"crossref","unstructured":"27) Webber, R.L. and Bettermann, W. (1999). A method for correcting for errors produced by variable magnification in three-dimensional tuned-aperture computed tomography. Dentomaxillofac Radiol 28, 305-310.","DOI":"10.1038\/sj.dmfr.4600463"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28) Webber, R.L. and Hendrickson, J.L. (2000). A comparison of the effect of task-specific with fixed beam alignment in tuned-aperture computed tomography. Dentomaxillofac Radiol 29, 223-229.","DOI":"10.1038\/sj.dmfr.4600535"},{"key":"29","doi-asserted-by":"crossref","unstructured":"29) Webber, R.L., Horton, R.A., Tyndall, D.A. and Ludlow, J.B. (1997). Tuned-aperture computed tomography (TACT): Theory and application for three-dimensional dento-alveolar imaging. Dentomaxillofac Radiol 26, 53-62.","DOI":"10.1038\/sj.dmfr.4600201"},{"key":"30","doi-asserted-by":"crossref","unstructured":"30) Webber, R.L., Horton, R.A., Underhill, T.E., Ludlow, J.B. and Tyndall, D.A. (1996). Comparison of film, direct digital, and tuned-aperture computed tomography images to identify the location of crestal defects around endosseous titanium implants. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 81, 480-490.","DOI":"10.1016\/S1079-2104(96)80029-1"},{"key":"31","doi-asserted-by":"crossref","unstructured":"31) Webber, R.L. and Messura, J.K. (1999). An in vivo comparison of diagnostic information obtained from tuned-aperture computed tomography and conventional dental radiographic imaging modalities. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 88, 239-247.","DOI":"10.1016\/S1079-2104(99)70122-8"},{"key":"32","doi-asserted-by":"crossref","unstructured":"32) Webber, R.L., Underhill, H.R. and Freimanis, R.I. (2000). A controlled evaluation of tuned-aperture computed tomography applied to digital spot mammography. J Digit Imaging 13, 90-97.","DOI":"10.1007\/BF03168373"},{"key":"33","doi-asserted-by":"crossref","unstructured":"33) Webber, R.L., Webber, S.E. and Moore, J. (2002). Hand-held three-dimensional dental X-ray system: Technical description and preliminary results. Dentomaxillofac Radiol 31, 240-248.","DOI":"10.1038\/sj.dmfr.4600697"},{"key":"34","doi-asserted-by":"crossref","unstructured":"34) Yamamoto, K., Farman, A.G., Webber, R.L., Horton, R.A. and Kuroyanagi, K. (1998). Effects of projection geometry and number of projections on accuracy of depth discrimination using tuned-aperture computed tomography (TACT) in dentistry. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 86, 126-130.","DOI":"10.1016\/S1079-2104(98)90162-7"},{"key":"35","doi-asserted-by":"crossref","unstructured":"35) Yamamoto, K., Farman, A.G., Webber, R.L., Horton, R.A. and Kuroyanagi, K. (1999). Effects of number of projections on accuracy of depth discrimination using tuned-aperture computed tomography (TACT) for three-dimensional dentoalveolar imaging of low-contrast details. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 88, 100-105.","DOI":"10.1016\/S1079-2104(99)70201-5"},{"key":"36","doi-asserted-by":"crossref","unstructured":"36) Yamamoto, K., Hayakawa, Y., Kobayashi, N., Kousuge, Y., Wakoh, M., Sekiguchi, H., Yakushiji, M. and Farman, A.G. (2002). Tuned-Aperture Computed Tomography (TACT<font size=\"-1\"><sup>&reg;<\/sup><\/font>) to assess impacted teeth using 2D slices and 3D pseudo-holograms. In The Proceedings of the 16th International Congress of Computer Assisted Radiology and Surgery (CARS2002). (H.U., Lemke et al. eds.) p.1117, Springer-Verlag, Berlin.","DOI":"10.1007\/978-3-642-56168-9_266"},{"key":"37","unstructured":"37) Yamamoto, K., Hayakawa, Y., Kobayashi, N., Kousuge, Y., Wakoh, M., Sekiguchi, H., Yakushiji, M. and Farman, A.G. (2002). Diagnostic value of tuned-aperture computed tomography for three-dimensional dentoalveolar imaging. Eizo Jyoho Medical 34, 1026-1031. (in Japanese)"},{"key":"38","doi-asserted-by":"crossref","unstructured":"38) Yamamoto, K., Hayakawa, Y., Kousuge, Y., Wakoh, M., Sekiguchi, H., Yakushiji, M. and Farman, A.G. (2003). Diagnostic value of tuned-aperture computed tomography versus conventional dentoalveolar imaging in assessment of impacted teeth. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 95, 109-118.","DOI":"10.1067\/moe.2003.17"},{"key":"39","doi-asserted-by":"crossref","unstructured":"39) Yamamoto, K., Nishikawa, K., Kobayashi, N., Kuroyanagi, K. and Farman, A.G. (2000). Evaluation of tuned-aperture computed tomography depth discrimination for image series acquired variously with linear horizontal, linear vertical, and conical beam projection arrays. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 89, 766-770.","DOI":"10.1067\/moe.2000.106296"},{"key":"40","doi-asserted-by":"crossref","unstructured":"40) Ziegler, C.M., Woertche, R., Brief, J. and Hassfeld, S. (2002). Clinical indications for digital volume tomography in oral and maxillofacial surgery. Dentomaxillofac Radiol 31, 126-130.","DOI":"10.1038\/sj.dmfr.4600680"}],"container-title":["The Bulletin of Tokyo Dental College"],"original-title":[],"language":"en","deposited":{"date-parts":[[2021,5,20]],"date-time":"2021-05-20T17:16:39Z","timestamp":1621530999000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.jstage.jst.go.jp\/article\/tdcpublication\/44\/3\/44_3_159\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003]]},"references-count":40,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2003]]}},"URL":"https:\/\/doi.org\/10.2209\/tdcpublication.44.159","relation":{},"ISSN":["0040-8891"],"issn-type":[{"value":"0040-8891","type":"print"}],"subject":[],"published":{"date-parts":[[2003]]}}}