{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T02:01:34Z","timestamp":1788919294937,"version":"build-2803163510"},"reference-count":79,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013,3]]},"abstract":"<jats:sec>\n                    <jats:title>Summary<\/jats:title>\n                    <jats:p>Implantable left ventricular assist devices (LVADs) are increasingly being used as a bridge to transplantation or as destination therapy in patients with end stage heart failure refractory to conventional medical therapy. A significant number of these patients have associated renal dysfunction before LVAD implantation, which may improve after LVAD placement due to enhanced perfusion. Other patients develop AKI after implantation. LVAD recipients who develop AKI requiring renal replacement therapy in the hospital or who ultimately require long-term outpatient hemodialysis therapy present management challenges with respect to hemodynamics, volume, and dialysis access. This review discusses the mechanics of a continuous-flow LVAD (the HeartMate II), the effects of continuous blood flow on the kidney, renal outcomes of patients after LVAD implantation, dialysis modality selection, vascular access, hemodynamic monitoring during the dialytic procedure, and other issues relevant to caring for these patients.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2215\/cjn.06210612","type":"journal-article","created":{"date-parts":[[2012,10,12]],"date-time":"2012-10-12T21:00:06Z","timestamp":1350075606000},"page":"484-496","source":"Crossref","is-referenced-by-count":86,"title":["Renal Failure in Patients with Left Ventricular Assist Devices"],"prefix":"10.2215","volume":"8","author":[{"given":"Ami M.","family":"Patel","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gbemisola A.","family":"Adeseun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Irfan","family":"Ahmed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nanhi","family":"Mitter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. Eduardo","family":"Rame","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael R.","family":"Rudnick","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-21-20230811","first-page":"e2","article-title":"Heart disease and stroke statistics\u20142012 update: A report from the American Heart Association.","volume":"125","author":"Roger","year":"2012","journal-title":"Circulation"},{"key":"R2-21-20230811","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1016\/j.ahj.2008.05.028","article-title":"Quality of care and outcomes among patients with heart failure and chronic kidney disease: A Get With the Guidelines \u2014 Heart Failure Program study.","volume":"156","author":"Patel","year":"2008","journal-title":"Am Heart J"},{"key":"R3-21-20230811","doi-asserted-by":"crossref","first-page":"1004","DOI":"10.1161\/01.CIR.0000116764.53225.A9","article-title":"Renal insufficiency and heart failure: Prognostic and therapeutic implications from a prospective cohort study.","volume":"109","author":"McAlister","year":"2004","journal-title":"Circulation"},{"key":"R4-21-20230811","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1056\/NEJMoa012175","article-title":"Long-term use of a left ventricular assist device for end-stage heart failure.","volume":"345","author":"Rose","year":"2001","journal-title":"N Engl J Med"},{"key":"R5-21-20230811","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.jtcvs.2004.04.044","article-title":"Left ventricular assist devices as destination therapy: A new look at survival.","volume":"129","author":"Park","year":"2005","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R7-21-20230811","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1111\/j.1540-8191.2008.00696.x","article-title":"Past, present, and future of long-term mechanical cardiac support in adults.","volume":"23","author":"Christiansen","year":"2008","journal-title":"J Card Surg"},{"key":"R8-21-20230811","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1016\/j.healun.2005.11.439","article-title":"Peripheral vascular reactivity in patients with pulsatile vs axial flow left ventricular assist device support.","volume":"25","author":"Amir","year":"2006","journal-title":"J Heart Lung Transplant"},{"key":"R9-21-20230811","first-page":"275","article-title":"Initial clinical experience with the HeartMate II axial-flow left ventricular assist device.","volume":"34","author":"Frazier","year":"2007","journal-title":"Tex Heart Inst J"},{"key":"R10-21-20230811","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1007\/s10047-005-0295-y","article-title":"Chronic nonpulsatile blood flow is compatible with normal end-organ function: Implications for LVAD development.","volume":"8","author":"Saito","year":"2005","journal-title":"J Artif Organs"},{"key":"R11-21-20230811","doi-asserted-by":"crossref","first-page":"2241","DOI":"10.1056\/NEJMoa0909938","article-title":"Advanced heart failure treated with continuous-flow left ventricular assist device.","volume":"361","author":"Slaughter","year":"2009","journal-title":"N Engl J Med"},{"key":"R12-21-20230811","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/j.healun.2011.12.001","article-title":"The Fourth INTERMACS Annual Report: 4,000 implants and counting.","volume":"31","author":"Kirklin","year":"2012","journal-title":"J Heart Lung Transplant"},{"key":"R13-21-20230811","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/S0003-4975(00)02639-4","article-title":"HeartMate II left ventricular assist system: from concept to first clinical use.","volume":"71","author":"Griffith","year":"2001","journal-title":"Ann Thorac Surg"},{"key":"R14-21-20230811","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1016\/j.healun.2010.01.011","article-title":"Clinical management of continuous-flow left ventricular assist devices in advanced heart failure.","volume":"29","author":"Slaughter","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"R15-21-20230811","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1016\/j.jacc.2005.09.070","article-title":"Same bridge, new destinations rethinking paradigms for mechanical cardiac support in heart failure.","volume":"47","author":"Felker","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"R16-21-20230811","doi-asserted-by":"crossref","first-page":"1515","DOI":"10.1161\/01.CIR.93.8.1515","article-title":"Plasma volume and its regulatory factors in congestive heart failure after implantation of long-term left ventricular assist devices.","volume":"93","author":"James","year":"1996","journal-title":"Circulation"},{"key":"R17-21-20230811","first-page":"1125","article-title":"Recovery of major organ function in patients awaiting heart transplantation with Thoratec ventricular assist devices.","volume":"13","author":"Farrar","year":"1994","journal-title":"J Heart Lung Transplant"},{"key":"R18-21-20230811","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1097\/01.mat.0000191334.51375.7e","article-title":"Neurocognitive function in patients with ventricular assist devices: A comparison of pulsatile and continuous blood flow devices.","volume":"52","author":"Zimpfer","year":"2006","journal-title":"ASAIO J"},{"key":"R19-21-20230811","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1016\/j.jacc.2009.03.055","article-title":"Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device.","volume":"54","author":"Pagani","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"R20-21-20230811","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1161\/CIRCHEARTFAILURE.111.963991","article-title":"Outcomes in advanced heart failure patients with left ventricular assist devices for destination therapy.","volume":"5","author":"Park","year":"2012","journal-title":"Circ Heart Fail"},{"key":"R21-21-20230811","doi-asserted-by":"crossref","first-page":"1890","DOI":"10.1016\/j.jacc.2010.10.062","article-title":"Results of the post-U.S. Food and Drug Administration-approval study with a continuous flow left ventricular assist device as a bridge to heart transplantation: A prospective study using the INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support).","volume":"57","author":"Starling","year":"2011","journal-title":"J Am Coll Cardiol"},{"key":"R22-21-20230811","doi-asserted-by":"crossref","first-page":"1490","DOI":"10.1056\/NEJMed010109","article-title":"Mechanical cardiac-support devices\u2014dreams and devilish details.","volume":"345","author":"Jessup","year":"2001","journal-title":"N Engl J Med"},{"key":"R23-21-20230811","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1016\/j.athoracsur.2009.01.022","article-title":"Renal function and outcome after continuous flow left ventricular assist device implantation.","volume":"87","author":"Sandner","year":"2009","journal-title":"Ann Thorac Surg"},{"key":"R24-21-20230811","first-page":"426","article-title":"Renal failure in patients with ventricular assist devices.","volume":"33","author":"Kanter","year":"1987","journal-title":"ASAIO Trans"},{"key":"R25-21-20230811","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/0002-8703(95)90056-X","article-title":"Selection criteria for placement of left ventricular assist devices.","volume":"129","author":"Oz","year":"1995","journal-title":"Am Heart J"},{"key":"R26-21-20230811","doi-asserted-by":"crossref","first-page":"904","DOI":"10.1016\/S0022-5223(98)70373-3","article-title":"One hundred patients with the HeartMate left ventricular assist device: Evolving concepts and technology.","volume":"115","author":"McCarthy","year":"1998","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R27-21-20230811","doi-asserted-by":"crossref","first-page":"1745","DOI":"10.1016\/j.athoracsur.2005.11.061","article-title":"Relationship between renal function and left ventricular assist device use.","volume":"81","author":"Butler","year":"2006","journal-title":"Ann Thorac Surg"},{"key":"R28-21-20230811","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1161\/CIRCULATIONAHA.107.691972","article-title":"Outcomes of left ventricular assist device implantation as destination therapy in the post-REMATCH era: Implications for patient selection.","volume":"116","author":"Lietz","year":"2007","journal-title":"Circulation"},{"key":"R29-21-20230811","doi-asserted-by":"crossref","first-page":"1631","DOI":"10.1253\/circj.CJ-11-1452","article-title":"Predictor of early mortality for severe heart failure patients with left ventricular assist device implantation: Significance of INTERMACS level and renal function.","volume":"76","author":"Yoshioka","year":"2012","journal-title":"Circ J"},{"key":"R30-21-20230811","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1016\/j.athoracsur.2011.11.058","article-title":"Serial changes in renal function as a prognostic indicator in advanced heart failure patients with left ventricular assist system.","volume":"93","author":"Iwashima","year":"2012","journal-title":"Ann Thorac Surg"},{"key":"R31-21-20230811","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/S0039-6109(03)00220-2","article-title":"Hemodynamics of chronic nonpulsatile flow: Implications for LVAD development.","volume":"84","author":"Saito","year":"2004","journal-title":"Surg Clin North Am"},{"key":"R32-21-20230811","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.healun.2004.04.018","article-title":"Physiology of continuous blood flow in recipients of rotary cardiac assist devices.","volume":"24","author":"Thalmann","year":"2005","journal-title":"J Heart Lung Transplant"},{"key":"R33-21-20230811","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/S0003-4975(03)01321-3","article-title":"Clinical experience with an implantable, intracardiac, continuous flow circulatory support device: Physiologic implications and their relationship to patient selection.","volume":"77","author":"Frazier","year":"2004","journal-title":"Ann Thorac Surg"},{"key":"R34-21-20230811","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1111\/j.1525-1594.1996.tb04502.x","article-title":"Effect of pulsatile and nonpulsatile assist on heart and kidney microcirculation with cardiogenic shock.","volume":"20","author":"Nakata","year":"1996","journal-title":"Artif Organs"},{"key":"R35-21-20230811","doi-asserted-by":"crossref","first-page":"M724","DOI":"10.1097\/00002480-199609000-00083","article-title":"The role of pulsatility in end-organ microcirculation after cardiogenic shock.","volume":"42","author":"Orime","year":"1996","journal-title":"ASAIO J"},{"key":"R36-21-20230811","doi-asserted-by":"crossref","first-page":"M333","DOI":"10.1097\/00002480-199507000-00025","article-title":"Five month survival in a calf supported with an intraventricular axial flow blood pump.","volume":"41","author":"Parnis","year":"1995","journal-title":"ASAIO J"},{"key":"R37-21-20230811","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/S0003-4975(02)04087-0","article-title":"Smooth muscle cell hypertrophy of renal cortex arteries with chronic continuous flow left ventricular assist.","volume":"75","author":"Kihara","year":"2003","journal-title":"Ann Thorac Surg"},{"key":"R38-21-20230811","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1007\/s100470200038","article-title":"Proliferative changes in the media of the afferent arterioles under prolonged continuous-flow left heart bypass.","volume":"5","author":"Ohnishi","year":"2002","journal-title":"J Artif Organs"},{"key":"R39-21-20230811","doi-asserted-by":"crossref","first-page":"1080","DOI":"10.1016\/S0003-4975(02)03846-8","article-title":"End-organ function during chronic nonpulsatile circulation.","volume":"74","author":"Saito","year":"2002","journal-title":"Ann Thorac Surg"},{"key":"R40-21-20230811","doi-asserted-by":"crossref","first-page":"974","DOI":"10.1046\/j.1525-1594.2002.07135.x","article-title":"Morphological changes of the arterial systems in the kidney under prolonged continuous flow left heart bypass.","volume":"26","author":"Ohnishi","year":"2002","journal-title":"Artif Organs"},{"key":"R41-21-20230811","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.jtcvs.2007.12.023","article-title":"Reduced pulsatility induces periarteritis in kidney: Role of the local renin-angiotensin system.","volume":"136","author":"Ootaki","year":"2008","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R42-21-20230811","doi-asserted-by":"crossref","first-page":"1167","DOI":"10.1016\/S0003-4975(03)00724-0","article-title":"Continuous axial-flow left ventricular assist device (Jarvik 2000) maintains kidney and liver perfusion for up to 6 months.","volume":"76","author":"Letsou","year":"2003","journal-title":"Ann Thorac Surg"},{"key":"R43-21-20230811","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1016\/j.healun.2007.05.012","article-title":"End-organ function in patients on long-term circulatory support with continuous- or pulsatile-flow assist devices.","volume":"26","author":"Radovancevic","year":"2007","journal-title":"J Heart Lung Transplant"},{"key":"R44-21-20230811","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1016\/j.healun.2007.12.012","article-title":"Renal function after implantation of continuous versus pulsatile flow left ventricular assist devices.","volume":"27","author":"Sandner","year":"2008","journal-title":"J Heart Lung Transplant"},{"key":"R45-21-20230811","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1016\/j.healun.2009.01.005","article-title":"Effects of centrifugal, axial, and pulsatile left ventricular assist device support on end-organ function in heart failure patients.","volume":"28","author":"Kamdar","year":"2009","journal-title":"J Heart Lung Transplant"},{"key":"R46-21-20230811","doi-asserted-by":"crossref","first-page":"2352","DOI":"10.1161\/CIRCULATIONAHA.108.814863","article-title":"Renal and hepatic function improve in advanced heart failure patients during continuous-flow support with the HeartMate II left ventricular assist device.","volume":"120","author":"Russell","year":"2009","journal-title":"Circulation"},{"key":"R47-21-20230811","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.jacc.2011.09.038","article-title":"Changes in renal function after implantation of continuous-flow left ventricular assist devices.","volume":"59","author":"Hasin","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"R48-21-20230811","doi-asserted-by":"crossref","first-page":"S185","DOI":"10.1055\/s-0029-1240709","article-title":"Effect of pulsatile and non-pulsatile left ventricular assist devices on the renin-angiotensin system in patients with end-stage heart failure.","volume":"58","author":"Welp","year":"2010","journal-title":"Thorac Cardiovasc Surg"},{"key":"R49-21-20230811","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1097\/00002480-200005000-00017","article-title":"Outcome of patients with ventricular assist devices and acute renal failure requiring renal replacement therapy.","volume":"46","author":"Kaltenmaier","year":"2000","journal-title":"ASAIO J"},{"key":"R50-21-20230811","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1067\/mtc.2001.118274","article-title":"Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation.","volume":"122","author":"Frazier","year":"2001","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R51-21-20230811","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1111\/j.1525-1594.2003.47331.x","article-title":"Ventricular assist devices as a bridge to cardiac transplantation: The Ottawa experience.","volume":"28","author":"Haddad","year":"2004","journal-title":"Artif Organs"},{"key":"R52-21-20230811","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1016\/j.healun.2005.07.002","article-title":"Mechanical circulatory support device database of the International Society for Heart and Lung Transplantation: Third annual report\u20142005.","volume":"24","author":"Deng","year":"2005","journal-title":"J Heart Lung Transplant"},{"key":"R53-21-20230811","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1016\/j.healun.2005.11.457","article-title":"Predictors and outcomes of continuous veno-venous hemodialysis use after implantation of a left ventricular assist device.","volume":"25","author":"Topkara","year":"2006","journal-title":"J Heart Lung Transplant"},{"key":"R54-21-20230811","doi-asserted-by":"crossref","first-page":"1082","DOI":"10.1016\/j.athoracsur.2006.10.034","article-title":"Clinical outcomes are similar in pulsatile and nonpulsatile left ventricular assist device recipients.","volume":"83","author":"Feller","year":"2007","journal-title":"Ann Thorac Surg"},{"key":"R55-21-20230811","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1056\/NEJMoa067758","article-title":"Use of a continuous-flow device in patients awaiting heart transplantation.","volume":"357","author":"Miller","year":"2007","journal-title":"N Engl J Med"},{"key":"R56-21-20230811","doi-asserted-by":"crossref","first-page":"874","DOI":"10.1016\/j.cardfail.2009.05.015","article-title":"Predictors of acute renal dysfunction after ventricular assist device placement.","volume":"15","author":"Alba","year":"2009","journal-title":"J Card Fail"},{"key":"R57-21-20230811","doi-asserted-by":"crossref","first-page":"981","DOI":"10.1016\/j.healun.2010.04.014","article-title":"Early adverse events as predictors of 1-year mortality during mechanical circulatory support.","volume":"29","author":"Genovese","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"R58-21-20230811","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/j.healun.2010.08.019","article-title":"Results of HeartMate II left ventricular assist device implantation on renal function in patients requiring post-implant renal replacement therapy.","volume":"30","author":"Demirozu","year":"2011","journal-title":"J Heart Lung Transplant"},{"key":"R59-21-20230811","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1161\/CIRCULATIONAHA.105.580506","article-title":"Renal function as a predictor of outcome in a broad spectrum of patients with heart failure.","volume":"113","author":"Hillege","year":"2006","journal-title":"Circulation"},{"key":"R60-21-20230811","doi-asserted-by":"crossref","first-page":"1369","DOI":"10.1016\/S0003-4975(00)01083-3","article-title":"Effects of left ventricular assist devices on outcomes in patients undergoing heart transplantation.","volume":"69","author":"Bank","year":"2000","journal-title":"Ann Thorac Surg"},{"key":"R61-21-20230811","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/0003-4975(93)90475-W","article-title":"Improved multiorgan function after prolonged univentricular support.","volume":"55","author":"Burnett","year":"1993","journal-title":"Ann Thorac Surg"},{"key":"R62-21-20230811","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/S0735-1097(02)02823-1","article-title":"Severe renal dysfunction complicating cardiogenic shock is not a contraindication to mechanical support as a bridge to cardiac transplantation.","volume":"41","author":"Khot","year":"2003","journal-title":"J Am Coll Cardiol"},{"key":"R63-21-20230811","doi-asserted-by":"crossref","first-page":"S29","DOI":"10.1016\/S0003-4975(03)00461-2","article-title":"Patient selection for left ventricular assist device therapy.","volume":"75","author":"Aaronson","year":"2003","journal-title":"Ann Thorac Surg"},{"key":"R64-21-20230811","doi-asserted-by":"crossref","first-page":"1348","DOI":"10.1016\/j.athoracsur.2010.10.036","article-title":"Impact of renal function before mechanical circulatory support on posttransplant renal outcomes.","volume":"91","author":"Singh","year":"2011","journal-title":"Ann Thorac Surg"},{"key":"R65-21-20230811","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1002\/lt.20445","article-title":"Renal function after orthotopic liver transplantation is predicted by duration of pretransplantation creatinine elevation.","volume":"11","author":"Campbell","year":"2005","journal-title":"Liver Transpl"},{"key":"R66-21-20230811","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1016\/j.athoracsur.2009.12.058","article-title":"Left ventricular assist device destination therapy versus extended criteria cardiac transplant.","volume":"89","author":"Daneshmand","year":"2010","journal-title":"Ann Thorac Surg"},{"key":"R67-21-20230811","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.healun.2010.12.001","article-title":"Third INTERMACS Annual Report: The evolution of destination therapy in the United States.","volume":"30","author":"Kirklin","year":"2011","journal-title":"J Heart Lung Transplant"},{"key":"R68-21-20230811","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1016\/j.healun.2010.01.004","article-title":"Natural course and risk factors for impaired renal function during the first year after heart transplantation.","volume":"29","author":"Jokinen","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"R69-21-20230811","doi-asserted-by":"crossref","first-page":"2225","DOI":"10.1161\/CIRCULATIONAHA.109.850610","article-title":"Evaluation for a ventricular assist device: selecting the appropriate candidate.","volume":"119","author":"Wilson","year":"2009","journal-title":"Circulation"},{"key":"R70-21-20230811","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1111\/j.1540-8191.2011.01310.x","article-title":"Mechanical circulatory support as a bridge to transplant candidacy.","volume":"26","author":"Elhenawy","year":"2011","journal-title":"J Card Surg"},{"key":"R71-21-20230811","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1111\/j.1525-1594.2011.01351.x","article-title":"Effect of pulsatile left ventricular assist system implantation on Doppler measurements of renal hemodynamics in patients with advanced heart failure.","volume":"36","author":"Iwashima","year":"2012","journal-title":"Artif Organs"},{"key":"R72-21-20230811","doi-asserted-by":"crossref","first-page":"II191","DOI":"10.1161\/01.CIR.92.9.191","article-title":"Effect of the implantable left ventricular assist device on neuroendocrine activation in heart failure.","volume":"92","author":"James","year":"1995","journal-title":"Circulation"},{"key":"R73-21-20230811","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/S0003-4975(01)02644-3","article-title":"Impacts of pulsatile systemic circulation on endothelium-derived nitric oxide release in anesthetized dogs.","volume":"72","author":"Nakano","year":"2001","journal-title":"Ann Thorac Surg"},{"key":"R74-21-20230811","doi-asserted-by":"crossref","first-page":"818","DOI":"10.1016\/S1053-2498(02)00644-7","article-title":"Intraperitoneal pocket for left ventricular assist device placement.","volume":"22","author":"Icenogle","year":"2003","journal-title":"J Heart Lung Transplant"},{"key":"R75-21-20230811","doi-asserted-by":"crossref","first-page":"386","DOI":"10.3747\/pdi.2011.00076","article-title":"Renal replacement therapy in congestive heart failure requiring left ventricular assist device augmentation.","volume":"32","author":"Thomas","year":"2012","journal-title":"Perit Dial Int"},{"key":"R76-21-20230811","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1016\/j.healun.2009.01.013","article-title":"Assessment of arterial blood pressure during support with an axial flow left ventricular assist device.","volume":"28","author":"Myers","year":"2009","journal-title":"J Heart Lung Transplant"},{"key":"R77-21-20230811","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1111\/j.1525-1594.2004.07095.x","article-title":"Automatic system for noninvasive blood pressure determination in rotary pump recipients.","volume":"28","author":"Schima","year":"2004","journal-title":"Artif Organs"},{"key":"R78-21-20230811","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1007\/s10877-009-9178-8","article-title":"A poor correlation exists between oscillometric and radial arterial blood pressure as measured by the Philips MP90 monitor.","volume":"23","author":"Mireles","year":"2009","journal-title":"J Clin Monit Comput"},{"key":"R81-21-20230811","doi-asserted-by":"crossref","first-page":"652","DOI":"10.1093\/bja\/aen052","article-title":"Laparoscopic cholecystectomy in a patient with an implantable left ventricular assist device.","volume":"100","author":"Kartha","year":"2008","journal-title":"Br J Anaesth"},{"key":"R82-21-20230811","doi-asserted-by":"crossref","first-page":"1647","DOI":"10.1016\/j.jacc.2009.06.035","article-title":"Ventricular assist devices the challenges of outpatient management.","volume":"54","author":"Wilson","year":"2009","journal-title":"J Am Coll Cardiol"}],"container-title":["Clinical Journal of the American Society of Nephrology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/01277230-201303000-00021","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,10]],"date-time":"2026-08-10T13:42:39Z","timestamp":1786369359000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/01277230-201303000-00021"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,3]]},"references-count":79,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2013]]}},"URL":"https:\/\/doi.org\/10.2215\/cjn.06210612","relation":{},"ISSN":["1555-9041"],"issn-type":[{"value":"1555-9041","type":"print"}],"subject":[],"published":{"date-parts":[[2013,3]]}}}