{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,15]],"date-time":"2026-11-15T03:57:47Z","timestamp":1794715067624,"version":"4.9.1"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2011,4]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background and objectives:<\/jats:title>\n                    <jats:p>Guidelines recommend systematically screening for stenosis using various methods, but no studies so far have compared all of the options. A prospective blinded study was performed to compare the performance of several bedside tests performed during dialysis in diagnosing angiographically proven &gt;50% fistula stenosis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design, setting, participants, &amp; measurements<\/jats:title>\n                    <jats:p>In an unselected population of 119 hemodialysis patients with mature fistulas, physical examination (PE) was conducted; dynamic and derived static venous pressure (VAPR), blood pump flow\/arterial pressure (Qb\/AP) ratio, recirculation (R), and access blood flow (Qa) were measured; and angiography was performed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Angiography identified 59 stenotic fistulas: 43 stenoses were located upstream from the venous needle (inflow stenosis), 12 were located downstream (outflow stenosis), and 4 were located at both sites. The optimal tests for identifying an inflow stenosis were Qa &lt; 650 ml\/min and the combination of a positive PE \u201cor\u201d Qa &lt; 650 ml\/min (accuracy 80% and 81%, respectively), the latter being preferable because it was more sensitive (85%\n                      <jats:italic toggle=\"yes\">versus<\/jats:italic>\n                      65%, respectively) for a comparable specificity (79%\n                      <jats:italic toggle=\"yes\">versus<\/jats:italic>\n                      89%, respectively). The best tests for identifying outflow stenosis were PE and VAPR, with no difference between the two (accuracy 91% and 85%, sensitivity 75% and 81%, specificity 93% and 86%, respectively), the former being preferable because it was more reproducible, easier to perform, and applicable to all fistulas.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>This study showed that fistula stenosis can be detected and located during dialysis with a moderate-to-excellent accuracy using PE and Qa measurement as screening procedures.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2215\/cjn.06220710","type":"journal-article","created":{"date-parts":[[2011,4,1]],"date-time":"2011-04-01T00:09:53Z","timestamp":1301616593000},"page":"819-826","source":"Crossref","is-referenced-by-count":67,"title":["In Search of an Optimal Bedside Screening Program for Arteriovenous Fistula Stenosis"],"prefix":"10.2215","volume":"6","author":[{"given":"Nicola","family":"Tessitore","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Valeria","family":"Bedogna","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edoardo","family":"Melilli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deborah","family":"Millardi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giancarlo","family":"Mansueto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giovanni","family":"Lipari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William","family":"Mantovani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elda","family":"Baggio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Albino","family":"Poli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Lupo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R4-20-20230811","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1016\/S0272-6386(03)00786-8","article-title":"Flow monitoring: Performance characteristics of ultrasound dilution versus colour Doppler ultrasound compared with fistulography","volume":"42","author":"Schwartz","year":"2003","journal-title":"Am J Kidney Dis"},{"key":"R5-20-20230811","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/S0272-6386(03)00659-0","article-title":"Diagnostic accuracy of ultrasound dilution access blood flow measurement in detecting stenosis and predicting thrombosis in native forearm arteriovenous fistulae for hemodialysis","volume":"42","author":"Tessitore","year":"2003","journal-title":"Am J Kidney Dis"},{"key":"R6-20-20230811","doi-asserted-by":"crossref","first-page":"2498","DOI":"10.1093\/ndt\/gfl242","article-title":"Does monthly native arteriovenous fistula blood flow surveillance detect significant stenosis\u2014A randomized controlled trial","volume":"21","author":"Polkinghorne","year":"2006","journal-title":"Nephrol Dial Transplant"},{"key":"R7-20-20230811","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1111\/j.1525-139X.2007.00419.x","article-title":"Accuracy of physical examination and intra-access pressure in the detection of stenosis in hemodialysis arteriovenous fistula","volume":"21","author":"Campos","year":"2008","journal-title":"Semin Dial"},{"key":"R8-20-20230811","first-page":"656","article-title":"The native arteriovenous fistula in 2007. Surveillance and monitoring","volume":"20","author":"Besarab","year":"2007","journal-title":"J Nephrol"},{"key":"R9-20-20230811","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1159\/000082009","article-title":"Vascular access monitoring: Methods and procedures\u2014Something to standardize?","volume":"23","author":"Lopot","year":"2005","journal-title":"Blood Purif"},{"key":"R10-20-20230811","doi-asserted-by":"crossref","first-page":"1364","DOI":"10.1038\/ki.1995.192","article-title":"The utility of intra-access monitoring in detecting and correcting venous outlet stenoses prior to thrombosis","volume":"47","author":"Besarab","year":"1995","journal-title":"Kidney Int"},{"key":"R11-20-20230811","doi-asserted-by":"crossref","first-page":"760","DOI":"10.1053\/ajkd.2002.35687","article-title":"Dynamic venous access pressure ratio test for hemodialysis access monitoring","volume":"40","author":"Frinak","year":"2002","journal-title":"Am J Kidney Dis"},{"key":"R12-20-20230811","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1111\/j.1525-139X.2009.00693.x","article-title":"Accuracy of ultrasound in the detection of inflow stenosis of arteriovenous fistulae: Results of a prospective study","volume":"23","author":"Salman","year":"2010","journal-title":"Seminars in Dialysis"},{"key":"R14-20-20230811","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1111\/j.1525-139X.2005.18314.x","article-title":"An algorithm for the physical examination of early fistula failure","volume":"18","author":"Beathard","year":"2005","journal-title":"Semin Dial"},{"key":"R15-20-20230811","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1111\/j.1525-139X.2008.00477.x","article-title":"Physical examination of arteriovenous fistulae by a renal fellow: Does it compare favourably to an experienced interventionalist?","volume":"21","author":"Leon","year":"2008","journal-title":"Semin Dial"},{"key":"R16-20-20230811","doi-asserted-by":"crossref","first-page":"1191","DOI":"10.2215\/CJN.02400607","article-title":"Accuracy of physical examination in the detection of arteriovenous fistula stenosis","volume":"2","author":"Asif","year":"2007","journal-title":"Clin J Am Soc Nephrol"},{"key":"R17-20-20230811","first-page":"797","article-title":"Accuracy of physical examination in the detection of arteriovenous fistula dysfunction","volume":"25","author":"Choi","year":"2006","journal-title":"Korean J Nephrol"},{"key":"R18-20-20230811","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1111\/j.1525-139X.2009.00682.x","article-title":"Controversial vascular access surveillance mandate","volume":"23","author":"Paulson","year":"2010","journal-title":"Seminars in Dialysis"},{"key":"R19-20-20230811","doi-asserted-by":"crossref","first-page":"1109","DOI":"10.1111\/j.1523-1755.2002.kid551.x","article-title":"Increasing arteriovenous fistulas in hemodialysis patients: Problems and solutions","volume":"62","author":"Allon","year":"2002","journal-title":"Kidney Int"},{"key":"R20-20-20230811","doi-asserted-by":"crossref","first-page":"1986","DOI":"10.1111\/j.1523-1755.2005.00299.x","article-title":"Inflow stenosis in arteriovenous fistulas and grafts: A multicenter, prospective study","volume":"67","author":"Asif","year":"2005","journal-title":"Kidney Int"},{"key":"R21-20-20230811","doi-asserted-by":"crossref","first-page":"1405","DOI":"10.1016\/S1051-0443(99)70252-6","article-title":"Reporting standards for percutaneous interventions in dialysis access","volume":"3","author":"Gray","year":"1999","journal-title":"J Vasc Interv Radiol"},{"key":"R22-20-20230811","doi-asserted-by":"crossref","first-page":"1729","DOI":"10.1681\/ASN.V1281729","article-title":"Screening for subclinical stenosis in native vessel arteriovenous fistulae","volume":"12","author":"Tonelli","year":"2001","journal-title":"J Am Soc Nephrol"},{"key":"R23-20-20230811","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1038\/ki.2009.92","article-title":"Diagnostic methods I: Sensitivity, specificity, and other measures of accuracy","volume":"75","author":"van Stralen","year":"2009","journal-title":"Kidney Int"},{"key":"R24-20-20230811","doi-asserted-by":"crossref","first-page":"2527","DOI":"10.1002\/sim.1227","article-title":"Assessing the gain in diagnostic performance when combining two diagnostic tests","volume":"21","author":"Macaskill","year":"2002","journal-title":"Stat Med"},{"key":"R25-20-20230811","doi-asserted-by":"crossref","first-page":"1369","DOI":"10.1503\/cmaj.1031981","article-title":"Tips for learners of evidence-based medicine: Measures of observer variability\/kappa statistics)","volume":"171","author":"McGinn","year":"2004","journal-title":"CMAJ"}],"container-title":["Clinical Journal of the American Society of Nephrology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/01277230-201104000-00020","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,10]],"date-time":"2026-08-10T13:40:42Z","timestamp":1786369242000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/01277230-201104000-00020"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,4]]},"references-count":21,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2011]]}},"URL":"https:\/\/doi.org\/10.2215\/cjn.06220710","relation":{"has-review":[{"id-type":"doi","id":"10.3410\/f.10565956.11424054","asserted-by":"object"}]},"ISSN":["1555-9041"],"issn-type":[{"value":"1555-9041","type":"print"}],"subject":[],"published":{"date-parts":[[2011,4]]}}}