{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T22:53:12Z","timestamp":1793141592992,"version":"4.5.0"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2012,5]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background and objectives<\/jats:title>\n                    <jats:p>Mechanical failure of the peritoneal dialysis (PD) catheter is an important cause of technique failure. Fluoroscopic guidewire manipulation may be undertaken in an attempt to correct the failure. The purpose of this study was to determine the efficacy of fluoroscopic manipulation of previously embedded PD catheters, the factors associated with successful manipulation, and the complication rate associated with manipulation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design, setting, participants, &amp; measurements<\/jats:title>\n                    <jats:p>A single-center, retrospective review of 70 consecutive PD patients undergoing fluoroscopic manipulation for mechanical failure of their PD catheter from June 2006 to February 2011 was undertaken. Logistic regression models were developed to determine the variables associated with successful manipulation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Of the 70 manipulations, 44 were successful (62.9%). In univariate analysis, catheters located in the pelvis compared with those in the upper abdomen (73.5% versus 42.9%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.01) and catheters that were previously functional compared with those that failed at exteriorization (75.0% versus 46.7%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.04) were more likely to be successfully manipulated. Time embedded, previous hemodialysis, and number of intra-abdominal surgeries were not correlated with likelihood of successful manipulation. In multivariate analysis, catheters located in the pelvis (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.01) and those with secondary failure (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.01) were more likely to successfully manipulated. Two of the patients developed peritonitis (2.9%), neither requiring cessation of PD.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Fluoroscopic manipulation is an effective and safe therapy for failed PD catheters that are unresponsive to conservative treatment. Properly positioned catheters and those that were previously functional are more likely to be successfully manipulated.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2215\/cjn.09850911","type":"journal-article","created":{"date-parts":[[2012,2,23]],"date-time":"2012-02-23T21:08:43Z","timestamp":1330031323000},"page":"795-800","source":"Crossref","is-referenced-by-count":35,"title":["Fluoroscopic Manipulation of Peritoneal Dialysis Catheters"],"prefix":"10.2215","volume":"7","author":[{"given":"Matthew","family":"Miller","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brendan","family":"McCormick","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Susan","family":"Lavoie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohan","family":"Biyani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deborah","family":"Zimmerman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-15-20230811","doi-asserted-by":"crossref","first-page":"S21","DOI":"10.1038\/sj.ki.5001912","article-title":"Peritoneal dialysis in the US: Evaluation of outcomes in contemporary cohorts.","volume":"103","author":"Mujais","year":"2006","journal-title":"Kidney Int Suppl"},{"key":"R2-15-20230811","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1016\/j.semnephrol.2011.01.003","article-title":"Peritoneal dialysis catheter insertion strategies and maintenance of catheter function.","volume":"31","author":"Shahbazi","year":"2011","journal-title":"Semin Nephrol"},{"key":"R3-15-20230811","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1177\/089686080802800207","article-title":"Fluoroscopic placement of peritoneal dialysis catheters: A harvest of the low-hanging fruits.","volume":"28","author":"Crabtree","year":"2008","journal-title":"Perit Dial Int"},{"key":"R4-15-20230811","doi-asserted-by":"crossref","first-page":"S38","DOI":"10.1038\/sj.ki.5001914","article-title":"Use of the embedded peritoneal dialysis catheter: Experience and results from a North American Center.","volume":"70","author":"McCormick","year":"2006","journal-title":"Kidney Int Suppl"},{"key":"R5-15-20230811","doi-asserted-by":"crossref","first-page":"2299","DOI":"10.1093\/ndt\/gfn003","article-title":"Complications and catheter survival with prolonged embedding of peritoneal dialysis catheters.","volume":"23","author":"Brown","year":"2008","journal-title":"Nephrol Dial Transplant"},{"key":"R6-15-20230811","first-page":"202","article-title":"Stiff wire manipulation of peritoneal dialysis catheters.","volume":"11","author":"Kappel","year":"1995","journal-title":"Adv Perit Dial"},{"key":"R7-15-20230811","doi-asserted-by":"crossref","first-page":"957","DOI":"10.1016\/S1051-0443(97)70693-6","article-title":"Guide wire directed manipulation of malfunctioning peritoneal dialysis catheters: A critical analysis.","volume":"8","author":"Savader","year":"1997","journal-title":"J Vasc Interv Radiol"},{"key":"R8-15-20230811","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1177\/089686089901900609","article-title":"Fluoroscopically-guided manipulation of malfunctioning peritoneal dialysis catheters.","volume":"19","author":"Simons","year":"1999","journal-title":"Perit Dial Int"},{"key":"R9-15-20230811","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1177\/089686080302300612","article-title":"Double guidewire method: A novel technique for correction of migrated Tenckhoff peritoneal dialysis catheter.","volume":"23","author":"Lee","year":"2003","journal-title":"Perit Dial Int"},{"key":"R10-15-20230811","first-page":"223","article-title":"Use of laparoscopy in the management of malfunctioning peritoneal dialysis catheters.","volume":"12","author":"Brandt","year":"1996","journal-title":"Adv Perit Dial"},{"key":"R11-15-20230811","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1007\/s004649900336","article-title":"Laparoscopic salvage of malfunctioning peritoneal catheters.","volume":"11","author":"Amerling","year":"1997","journal-title":"Surg Endosc"},{"key":"R12-15-20230811","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1007\/s004640080008","article-title":"Laparoscopic management of malfunctioning peritoneal dialysis catheters.","volume":"15","author":"Yilmazlar","year":"2001","journal-title":"Surg Endosc"},{"key":"R13-15-20230811","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1089\/089277902753752214","article-title":"Laparoscopic omentectomy for salvage of peritoneal dialysis catheters.","volume":"16","author":"Lee","year":"2002","journal-title":"J Endourol"},{"key":"R14-15-20230811","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1177\/089686080602600316","article-title":"Laparoscopic findings of peritoneal dialysis catheter malfunction and management outcomes.","volume":"26","author":"Yilmazlar","year":"2006","journal-title":"Perit Dial Int"}],"container-title":["Clinical Journal of the American Society of Nephrology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/01277230-201205000-00015","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,10]],"date-time":"2026-08-10T13:38:21Z","timestamp":1786369101000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/01277230-201205000-00015"}},"subtitle":["Outcomes and Factors Associated with Successful Manipulation"],"short-title":[],"issued":{"date-parts":[[2012,5]]},"references-count":14,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2012]]}},"URL":"https:\/\/doi.org\/10.2215\/cjn.09850911","relation":{},"ISSN":["1555-9041"],"issn-type":[{"value":"1555-9041","type":"print"}],"subject":[],"published":{"date-parts":[[2012,5]]}}}