{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,10]],"date-time":"2026-08-10T14:46:45Z","timestamp":1786373205832,"version":"build-2736575974"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013,9]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background and objectives<\/jats:title>\n                    <jats:p>Achieving and maintaining optimal fluid status remains a major challenge in hemodialysis therapy. The aim of this interventional study was to assess the feasibility and clinical consequences of active fluid management guided by bioimpedance spectroscopy in chronic hemodialysis patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design, setting, participants, &amp; measurements<\/jats:title>\n                    <jats:p>Fluid status was optimized prospectively in 55 chronic hemodialysis patients over 3 months (November 2011 to February 2012). Predialysis fluid overload was measured weekly using the Fresenius Body Composition Monitor. Time-averaged fluid overload was calculated as the average between pre- and postdialysis fluid overload. The study aimed to bring the time-averaged fluid overload of all patients into a target range of 0.5\u00b10.75 L within the first month and maintain optimal fluid status until study end. Postweight was adjusted weekly according to a predefined protocol.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Time-averaged fluid overload in the complete study cohort was 0.9\u00b11.6 L at baseline and 0.6\u00b11.1 L at study end. Time-averaged fluid overload decreased by \u22121.20\u00b11.32 L (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.01) in the fluid-overloaded group (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      =17), remained unchanged in the normovolemic group (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      =26,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.59), and increased by 0.59\u00b10.76 L (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.02) in the dehydrated group (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      =12). Every 1 L change in fluid overload was accompanied by a 9.9 mmHg\/L change in predialysis systolic BP (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      =0.55,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.001). At study end, 76% of all patients were either on time-averaged fluid overload target or at least closer to target than at study start. The number of intradialytic symptoms did not change significantly in any of the subgroups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Active fluid management guided by bioimpedance spectroscopy was associated with an improvement in overall fluid status and BP.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2215\/cjn.12411212","type":"journal-article","created":{"date-parts":[[2013,8,16]],"date-time":"2013-08-16T00:06:28Z","timestamp":1376611588000},"page":"1575-1582","source":"Crossref","is-referenced-by-count":146,"title":["Bioimpedance-Guided Fluid Management in Hemodialysis Patients"],"prefix":"10.2215","volume":"8","author":[{"given":"Ulrich","family":"Moissl","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marta","family":"Arias-Guill\u00e9n","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Wabel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"N\u00e9stor","family":"Fontser\u00e9","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Montserrat","family":"Carrera","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 Maria","family":"Campistol","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco","family":"Maduell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-17-20230811","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1161\/CIRCULATIONAHA.108.807362","article-title":"Fluid retention is associated with cardiovascular mortality in patients undergoing long-term hemodialysis.","volume":"119","author":"Kalantar-Zadeh","year":"2009","journal-title":"Circulation"},{"key":"R2-17-20230811","doi-asserted-by":"crossref","first-page":"1574","DOI":"10.1093\/ndt\/gfn707","article-title":"The mortality risk of overhydration in haemodialysis patients.","volume":"24","author":"Wizemann","year":"2009","journal-title":"Nephrol Dial Transplant"},{"key":"R3-17-20230811","doi-asserted-by":"crossref","first-page":"2404","DOI":"10.1093\/ndt\/gfr678","article-title":"Importance of normohydration for the long-term survival of haemodialysis patients.","volume":"27","author":"Chazot","year":"2012","journal-title":"Nephrol Dial Transplant"},{"key":"R4-17-20230811","doi-asserted-by":"crossref","first-page":"c173","DOI":"10.1159\/000339099","article-title":"Volume is not the only key to hypertension control in dialysis patients.","volume":"120","author":"Odudu","year":"2012","journal-title":"Nephron Clin Pract"},{"key":"R5-17-20230811","doi-asserted-by":"crossref","first-page":"2140","DOI":"10.1093\/ndt\/gfs094","article-title":"Probing \u2018dry weight\u2019 in haemodialysis patients: \u2018Back to the future\u2019.","volume":"27","author":"Canaud","year":"2012","journal-title":"Nephrol Dial Transplant"},{"key":"R6-17-20230811","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1111\/j.1542-4758.2012.00689.x","article-title":"Optimal fluid control can normalize cardiovascular risk markers and limit left ventricular hypertrophy in thrice weekly dialysis patients.","volume":"16","author":"Velasco","year":"2012","journal-title":"Hemodial Int"},{"key":"R7-17-20230811","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1093\/ndt\/gfp487","article-title":"Guided optimization of fluid status in haemodialysis patients.","volume":"25","author":"Machek","year":"2010","journal-title":"Nephrol Dial Transplant"},{"key":"R8-17-20230811","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1159\/000322617","article-title":"Volume control in peritoneal dialysis patients guided by bioimpedance spectroscopy assessment.","volume":"31","author":"Luo","year":"2011","journal-title":"Blood Purif"},{"key":"R9-17-20230811","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1007\/s11255-011-0022-y","article-title":"Randomized trial of bioelectrical impedance analysis versus clinical criteria for guiding ultrafiltration in hemodialysis patients: Effects on blood pressure, hydration status, and arterial stiffness.","volume":"44","author":"Onofriescu","year":"2012","journal-title":"Int Urol Nephrol"},{"key":"R11-17-20230811","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1093\/ajcn\/85.1.80","article-title":"A whole-body model to distinguish excess fluid from the hydration of major body tissues.","volume":"85","author":"Chamney","year":"2007","journal-title":"Am J Clin Nutr"},{"key":"R12-17-20230811","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1088\/0967-3334\/27\/9\/012","article-title":"Body fluid volume determination via body composition spectroscopy in health and disease.","volume":"27","author":"Moissl","year":"2006","journal-title":"Physiol Meas"},{"key":"R13-17-20230811","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1159\/000167013","article-title":"Importance of whole-body bioimpedance spectroscopy for the management of fluid balance.","volume":"27","author":"Wabel","year":"2009","journal-title":"Blood Purif"},{"key":"R14-17-20230811","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1161\/HYPERTENSIONAHA.108.125674","article-title":"Dry-weight reduction in hypertensive hemodialysis patients (DRIP): A randomized, controlled trial.","volume":"53","author":"Agarwal","year":"2009","journal-title":"Hypertension"},{"key":"R15-17-20230811","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1111\/j.1542-4758.2012.00731.x","article-title":"Patient experiences and preferences on short daily and nocturnal home hemodialysis.","volume":"17","author":"Xi","year":"2013","journal-title":"Hemodial Int"},{"key":"R16-17-20230811","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1186\/1745-6215-13-79","article-title":"Blood volume-monitored regulation of ultrafiltration in fluid-overloaded hemodialysis patients: Study protocol for a randomized controlled trial.","volume":"13","author":"Hecking","year":"2012","journal-title":"Trials"}],"container-title":["Clinical Journal of the American Society of Nephrology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/01277230-201309000-00017","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,10]],"date-time":"2026-08-10T13:43:35Z","timestamp":1786369415000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/01277230-201309000-00017"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,9]]},"references-count":15,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2013]]}},"URL":"https:\/\/doi.org\/10.2215\/cjn.12411212","relation":{},"ISSN":["1555-9041"],"issn-type":[{"value":"1555-9041","type":"print"}],"subject":[],"published":{"date-parts":[[2013,9]]}}}