{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T12:14:52Z","timestamp":1791202492459,"version":"4.2.0"},"reference-count":7,"publisher":"Becaris Publishing Limited","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Comp. Eff. Res."],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:p>\n            <jats:bold>Aim:<\/jats:bold>\n            To analyze intraoperative temperature change over time following spinal anesthesia for cesarean delivery using temperature enabled Foley catheters.\n            <jats:bold>Materials &amp; methods:<\/jats:bold>\n            512 records of women who underwent scheduled cesarean deliveries were retrospectively identified from January 1, 2018 through September 9, 2018 using our anesthesia information management system.\n            <jats:bold>Results:<\/jats:bold>\n            Median minimum temperature at min\u00a01 following foley insertion was 35.24\u00b0C (interquartile range: 1.43), with an average of 12\u00a0minutes until temperature equilibration at median maximum temperature of 36.54\u00b0C (interquartile range 0.39). Temperature dropped to a nadir of 35.9\u00b0C at the 45\u00a0min\u00a0mark, reflecting an average 0.64\u00b0C decline in temperature.\n            <jats:bold>Conclusion:<\/jats:bold>\n            Bladder temperature is a useful surrogate for core temperature and offers a practical solution to continuous temperature monitoring in awake patients.\n          <\/jats:p>","DOI":"10.2217\/cer-2020-0183","type":"journal-article","created":{"date-parts":[[2020,12,16]],"date-time":"2020-12-16T12:41:08Z","timestamp":1608122468000},"page":"13-15","source":"Crossref","is-referenced-by-count":2,"title":["Core temperature monitoring during cesarean delivery under spinal anesthesia: a quality improvement descriptive study"],"prefix":"10.57264","volume":"10","author":[{"given":"Laura","family":"Burey","sequence":"first","affiliation":[{"name":"Weill Cornell Medicine, Department of Anesthesiology, 525 East 68th Street, Box 124, New York, NY 10065, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9402-2141","authenticated-orcid":false,"given":"Briana","family":"Lui","sequence":"additional","affiliation":[{"name":"Weill Cornell Medicine, Department of Anesthesiology, 525 East 68th Street, Box 124, New York, NY 10065, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1069-0685","authenticated-orcid":false,"given":"Robert S","family":"White","sequence":"additional","affiliation":[{"name":"Weill Cornell Medicine, Department of Anesthesiology, 525 East 68th Street, Box 124, New York, NY 10065, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Virginia E","family":"Tangel","sequence":"additional","affiliation":[{"name":"Weill Cornell Medicine, Department of Anesthesiology, 525 East 68th Street, Box 124, New York, NY 10065, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Klaus","family":"Kjaer","sequence":"additional","affiliation":[{"name":"Weill Cornell Medicine, Department of Anesthesiology, 525 East 68th Street, Box 124, New York, NY 10065, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"36897","reference":[{"issue":"1","key":"e_1_3_2_2_2","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1213\/ANE.0000000000002604","article-title":"Inadvertent perioperative hypothermia induced by spinal anesthesia for cesarean delivery might be more significant than we think: are we doing enough to warm our parturients?","volume":"126","author":"Allen TK","year":"2018","unstructured":"Allen TK, Habib AS. Inadvertent perioperative hypothermia induced by spinal anesthesia for cesarean delivery might be more significant than we think: are we doing enough to warm our parturients? Anesth. Analg. 126(1), 7\u20139 (2018).","journal-title":"Anesth. Analg."},{"issue":"4","key":"e_1_3_2_3_2","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1016\/S1521-6896(03)00052-1","article-title":"Consequences of inadvertent perioperative hypothermia","volume":"17","author":"Doufas AG","year":"2003","unstructured":"Doufas AG. Consequences of inadvertent perioperative hypothermia. Best Pract. Res. Clin. Anaesth. 17(4), 535\u2013549 (2003).","journal-title":"Best Pract. Res. Clin. Anaesth."},{"issue":"1","key":"e_1_3_2_4_2","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1213\/ANE.0000000000001256","article-title":"Neonatal and maternal temperature regulation during and after delivery","volume":"123","author":"Perlman J","year":"2016","unstructured":"Perlman J, Kjaer K. Neonatal and maternal temperature regulation during and after delivery. Anesth. Analg. 123(1), 168\u2013172 (2016).","journal-title":"Anesth. Analg."},{"issue":"2","key":"e_1_3_2_5_2","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1213\/00000539-199902000-00028","article-title":"Temperature monitoring practices during regional anesthesia","volume":"88","author":"Frank SM","year":"1999","unstructured":"Frank SM, Nguyen JM, Garcia CM, Barnes RA. Temperature monitoring practices during regional anesthesia. Anesth. Analg. 88(2), 373\u2013377 (1999).","journal-title":"Anesth. Analg."},{"issue":"1","key":"e_1_3_2_6_2","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1213\/ANE.0000000000002326","article-title":"Core temperature monitoring in obstetric spinal anesthesia using an ingestible telemetric sensor","volume":"126","author":"Du Toit L","year":"2018","unstructured":"Du Toit L, Van Dyk D, Hofmeyr R, Lombard CJ, Dyer RA. Core temperature monitoring in obstetric spinal anesthesia using an ingestible telemetric sensor. Anesth. Analg. 126(1), 190\u2013195 (2018).","journal-title":"Anesth. Analg."},{"key":"e_1_3_2_7_2","unstructured":"World Health Organization. Thermal protection of the newborn: a practical guide.Report No. WHO\/RHT\/MSM\/97.2. (1997)."},{"issue":"10038","key":"e_1_3_2_8_2","doi-asserted-by":"crossref","first-page":"2655","DOI":"10.1016\/S0140-6736(15)00981-2","article-title":"Perioperative thermoregulation and heat balance","volume":"387","author":"Sessler DI","year":"2016","unstructured":"Sessler DI. Perioperative thermoregulation and heat balance. Lancet 387(10038), 2655\u20132664 (2016).","journal-title":"Lancet"}],"container-title":["Journal of Comparative Effectiveness Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/becarispublishing.com\/doi\/pdf\/10.2217\/cer-2020-0183","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,19]],"date-time":"2023-03-19T12:32:53Z","timestamp":1679229173000},"score":1,"resource":{"primary":{"URL":"https:\/\/becarispublishing.com\/doi\/10.2217\/cer-2020-0183"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":7,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,1]]}},"alternative-id":["10.2217\/cer-2020-0183"],"URL":"https:\/\/doi.org\/10.2217\/cer-2020-0183","relation":{},"ISSN":["2042-6305","2042-6313"],"issn-type":[{"value":"2042-6305","type":"print"},{"value":"2042-6313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1]]}}}