{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T13:19:07Z","timestamp":1760015947496},"reference-count":20,"publisher":"The Japanese Society of Interventional Radiology","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020]]},"DOI":"10.22575\/interventionalradiology.2019-0009","type":"journal-article","created":{"date-parts":[[2020,5,13]],"date-time":"2020-05-13T22:05:15Z","timestamp":1589407515000},"page":"67-73","source":"Crossref","is-referenced-by-count":3,"title":["Radiation Exposure of Interventional Radiologists during Computed Tomography Fluoroscopy-Guided Percutaneous Cryoablation"],"prefix":"10.22575","volume":"5","author":[{"given":"Yuko","family":"Seki","sequence":"first","affiliation":[{"name":"Department of Radiology, Gunma University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masaya","family":"Miyazaki","sequence":"additional","affiliation":[{"name":"Department of Applied Medical Imaging, Gunma University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasuhiro","family":"Fukushima","sequence":"additional","affiliation":[{"name":"Division of Clinical Radiology Service, Kyoto University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masashi","family":"Ando","sequence":"additional","affiliation":[{"name":"Department of Radiology, Gunma University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshito","family":"Tsushima","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology and Nuclear Medicine, Gunma University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"9863","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Atwell TD, Schmit GD, Boorjian SA, et al. Percutaneous ablation of renal masses measuring 3.0 cm and smaller: comparative local control and complications after radiofrequency ablation and cryoablation. AJR Am J Roentgenol 2013; 200: 461-466.","DOI":"10.2214\/AJR.12.8618"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2. Callstrom MR, Dupuy DE, Solomon SB, et al. Percutaneous image-guided cryoablation of painful metastases involving bone. Cancer 2013; 119: 1033-1041.","DOI":"10.1002\/cncr.27793"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Lee SM, Won JY, Lee DY, et al. Percutaneous cryoablation of small hepatocellular carcinomas using a 17-gauge ultrathin probe. Clin Radiol 2011; 66: 752-759.","DOI":"10.1016\/j.crad.2011.02.015"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Kumasaka S, Miyazaki M, Tsushima Y. CT-Guided percutaneous cryoablation of an aggressive osteoblastoma: a case report. J Vasc Interv Radiol 2015; 26: 1746-1748.","DOI":"10.1016\/j.jvir.2015.08.002"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Miyazaki M, Iguchi T, Takaki H, et al. Ablation protocols and ancillary procedures in tumor ablation therapy: consensus from Japanese experts. Jpn J Radiol 2016; 34: 647-656.","DOI":"10.1007\/s11604-016-0569-8"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Yashiro H, Nakatsuka S, Inoue M, et al. Factors affecting local progression after percutaneous cryoablation of lung tumors. J Vasc Interv Radiol 2013; 24: 813-821.","DOI":"10.1016\/j.jvir.2012.12.026"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Pereira MF, Alves JG, Sarmento S, et al. Preliminary assessment of the dose to the interventional radiologist in fluoro-CT-guided procedures. Radiat Prot Dosimetry 2011; 144: 448-452.","DOI":"10.1093\/rpd\/ncq418"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Teeuwisse WM, Geleijns J, Broerse JJ, et al. Patient and staff dose during CT guided biopsy, drainage and coagulation. Br J Radiol 2001; 74: 720-726.","DOI":"10.1259\/bjr.74.884.740720"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Kim GR, Hur J, Lee SM, et al. CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance. Eur Radiol 2011; 21: 232-239.","DOI":"10.1007\/s00330-010-1936-y"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Ekpo EU, Bakhshi S, Ryan E, et al. Operator eye doses during computed tomography fluoroscopic lung biopsy. J Radio Prot 2016; 36: 290-298.","DOI":"10.1088\/0952-4746\/36\/2\/290"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Stewart JK, Looney CB, Anderson-Evans CD, et al. Percutaneous cryoablation of renal masses under CT fluoroscopy: radiation doses to the patient and interventionalist. Abdom Imaging 2015; 40: 2606-2612.","DOI":"10.1007\/s00261-015-0456-2"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Matsui Y, Hiraki T, Gobara H, et al. Radiation exposure of interventional radiologists during computed tomography fluoroscopy-guided renal cryoablation and lung radiofrequency ablation: direct measurement in a clinical setting. Cardiovasc Intervent Radiol 2016; 39: 894-901.","DOI":"10.1007\/s00270-016-1308-3"},{"key":"13","unstructured":"13. Gobara H, Hiraki T, Iguchi T, et al. Hydrodissection and cryoablation for renal tumor. Medix 2015; 63: 4-7."},{"key":"14","doi-asserted-by":"crossref","unstructured":"14. Hohl C, Suess C, Wildberger JE, et al. Dose reduction during CT fluoroscopy: phantom study of angular beam modulation. Radiology 2008; 246: 519-525.","DOI":"10.1148\/radiol.2462061968"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Saidatul A, Azlan C, Megat AM, Abdullah B, Ng K. A survey of radiation dose to patients and operators during radiofrequency ablation using computed tomography. Biomed Imaging Interv J 2010; 6: e2.","DOI":"10.2349\/biij.6.1.e2"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16. International commission on radiological protection. ICRP statement on tissue reactions \/ early and late effects of radiation in normal tissues and organs - threshold doses for tissue reactions in a radiation protection context. ICRP Publication 118. Ann. ICRP 2012; 41: 1-322.","DOI":"10.1016\/j.icrp.2012.02.001"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17. Nawfel RD, Judy PF, Silverman SG, Hooton S, et al. Patient and personnel exposure during CT fluoroscopy-guided interventional procedures. Radiology 2000; 216: 180-184.","DOI":"10.1148\/radiology.216.1.r00jl39180"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18. Haga Y, Chida K, Kaga Y, et al. Occupational eye dose in interventional cardiology procedures. Sci Rep 2017; 7: 569.","DOI":"10.1038\/s41598-017-00556-3"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19. Harui S, Matsumoto M, Ogata Y. Energy characteristics and examination of the dose correction of each element type in small size radiophotoluminescence glass dosimetry element system. Nihon Hoshasen Gijutsu Gakkai Zasshi 2010; 66: 509-514.","DOI":"10.6009\/jjrt.66.509"},{"key":"20","unstructured":"20. Yamazaki K, Ebata H, Ohtaka T, et al. Cumulative dose measurements using radiophotoluminescence glass dosimeter (2) comparison with thermoluminescence dosimeter. Annual Report of Niigata Prefectural Research Laboratory for Health and Environment 2001; 16: 90-97."}],"container-title":["Interventional Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/interventionalradiology\/5\/2\/5_2019-0009\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,4]],"date-time":"2020-07-04T04:30:26Z","timestamp":1593837026000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/interventionalradiology\/5\/2\/5_2019-0009\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020]]},"references-count":20,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.22575\/interventionalradiology.2019-0009","relation":{},"ISSN":["2432-0935"],"issn-type":[{"value":"2432-0935","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020]]}}}