{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,8]],"date-time":"2026-02-08T01:21:11Z","timestamp":1770513671880,"version":"3.49.0"},"reference-count":18,"publisher":"The Japanese Society of Interventional Radiology","issue":"0","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,2,2]]},"DOI":"10.22575\/interventionalradiology.2025-0051","type":"journal-article","created":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T22:08:40Z","timestamp":1769983720000},"page":"e2025-0051-e2025-0051","source":"Crossref","is-referenced-by-count":0,"title":["Real-time Fluoroscopic Fusion Imaging Guidance Using Angio-computed Tomography for Percutaneous Drainage of a Difficult-to-access Liver Abscess: A Case Report"],"prefix":"10.22575","volume":"11","author":[{"given":"Shintaro","family":"Kimura","sequence":"first","affiliation":[{"name":"Department of Diagnostic Radiology, National Cancer Center Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shunsuke","family":"Sugawara","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, National Cancer Center Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chihiro","family":"Itou","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, National Cancer Center Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mizuki","family":"Ozawa","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, National Cancer Center Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rakuhei","family":"Nakama","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, National Cancer Center Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiromitsu","family":"Hiruma","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, National Cancer Center Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Miyuki","family":"Sone","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, National Cancer Center Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"9863","reference":[{"key":"1","doi-asserted-by":"publisher","unstructured":"1. Schechter S, Eisenstat TE, Oliver GC, Rubin RJ, Salvati EP. Computerized tomographic scan-guided drainage of intra-abdominal abscesses. Preoperative and postoperative modalities in colon and rectal surgery. Dis Colon Rectum. 1994; 37: 984-988. doi:10.1007\/BF02049309.","DOI":"10.1007\/BF02049309"},{"key":"2","doi-asserted-by":"publisher","unstructured":"2. Liu S, Tian Z, Jiang Y, Mao T, Ding X, Jing X. Endoscopic ultrasound-guided drainage to abdominal abscess: a systematic review and meta-analysis. J Minim Access Surg. 2022; 18: 489-496. doi:10.4103\/jmas.jmas_349_21.","DOI":"10.4103\/jmas.jmas_349_21"},{"key":"3","doi-asserted-by":"publisher","unstructured":"3. Stangenberg L, Shuja F, Carelsen B, Elenbaas T, Wyers MC, Schermerhorn ML. A novel tool for three-dimensional roadmapping reduces radiation exposure and contrast agent dose in complex endovascular interventions. J Vasc Surg. 2015; 62: 448-455. doi:10.1016\/j.jvs.2015.03.041.","DOI":"10.1016\/j.jvs.2015.03.041"},{"key":"4","doi-asserted-by":"publisher","unstructured":"4. Zhang Q, Sun Q, Zhang Y, et al. Three-dimensional image fusion of CTA and angiography for real-time guidance during neurointerventional procedures. J Neurointerv Surg. 2017; 9: 302-306. doi:10.1136\/neurintsurg-2015-012216.","DOI":"10.1136\/neurintsurg-2015-012216"},{"key":"5","doi-asserted-by":"publisher","unstructured":"5. Stahlberg E, Sieren M, Anton S, et al. Fusion imaging reduces radiation and contrast medium exposure during endovascular revascularization of iliac steno-occlusive disease. Cardiovasc Intervent Radiol. 2019; 42: 1635-1643. doi:10.1007\/s00270-019-02250-5.","DOI":"10.1007\/s00270-019-02250-5"},{"key":"6","doi-asserted-by":"publisher","unstructured":"6. Arai Y. Hybrid procedure suites: combining computed tomography and conventional angiography. Br J Radiol. 2025; 98: 1748-1753. doi:10.1093\/bjr\/tqaf151.","DOI":"10.1093\/bjr\/tqaf151"},{"key":"7","doi-asserted-by":"publisher","unstructured":"7. Yueh N, Halvorsen RA Jr, Letourneau JG, Crass JR. Gantry tilt technique for CT-guided biopsy and drainage. J Comput Assist Tomogr. 1989; 13: 182-184. doi:10.1097\/00004728-198901000-00047.","DOI":"10.1097\/00004728-198901000-00047"},{"key":"8","doi-asserted-by":"publisher","unstructured":"8. Maher MM, Gervais DA, Kalra MK, et al. The inaccessible or undrainable abscess: how to drain it. RadioGraphics. 2004; 24: 717-735. doi:10.1148\/rg.243035100.","DOI":"10.1148\/rg.243035100"},{"key":"9","doi-asserted-by":"publisher","unstructured":"9. Jiao de C, Li TF, Han XW, et al. Clinical applications of the C-arm cone-beam CT-based 3D needle guidance system in performing percutaneous transthoracic needle biopsy of pulmonary lesions. Diagn Interv Radiol. 2014; 20: 470-474. doi:10.5152\/dir.2014.13463.","DOI":"10.5152\/dir.2014.13463"},{"key":"10","doi-asserted-by":"publisher","unstructured":"10. Matityahu A, Kahler D, Krettek C, et al. Three-dimensional navigation is more accurate than two-dimensional navigation or conventional fluoroscopy for percutaneous sacroiliac screw fixation in the dysmorphic sacrum: a randomized multicenter study. J Orthop Trauma. 2014; 28: 707-710. doi:10.1097\/BOT.0000000000000092.","DOI":"10.1097\/BOT.0000000000000092"},{"key":"11","doi-asserted-by":"publisher","unstructured":"11. Kroeze SG, Huisman M, Verkooijen HM, van Diest PJ, Ruud Bosch JL, van den Bosch MA. Real-time 3D fluoroscopy-guided large core needle biopsy of renal masses: a critical early evaluation according to the IDEAL recommendations. Cardiovasc Intervent Radiol. 2012; 35: 680-685. doi:10.1007\/s00270-011-0237-4.","DOI":"10.1007\/s00270-011-0237-4"},{"key":"12","doi-asserted-by":"publisher","unstructured":"12. Braak SJ, van Strijen MJ, van Leersum M, van Es HW, van Heesewijk JP. Real-Time 3D fluoroscopy guidance during needle interventions: technique, accuracy, and feasibility. AJR Am J Roentgenol. 2010; 194: W445-W451. doi:10.2214\/AJR.09.3647.","DOI":"10.2214\/AJR.09.3647"},{"key":"13","doi-asserted-by":"publisher","unstructured":"13. McKay T, Ingraham CR, Johnson GE, Kogut MJ, Vaidya S, Padia SA. Cone-beam CT with fluoroscopic overlay versus conventional CT guidance for percutaneous abdominopelvic abscess drain placement. J Vasc Interv Radiol. 2016; 27: 52-57. doi:10.1016\/j.jvir.2015.09.016.","DOI":"10.1016\/j.jvir.2015.09.016"},{"key":"14","doi-asserted-by":"publisher","unstructured":"14. Sailer AM, de Haan MW, Peppelenbosch AG, Jacobs MJ, Wildberger JE, Schurink GW. CTA with fluoroscopy image fusion guidance in endovascular complex aortic aneurysm repair. Eur J Vasc Endovasc Surg. 2014; 47: 349-356. doi:10.1016\/j.ejvs.2013.12.022.","DOI":"10.1016\/j.ejvs.2013.12.022"},{"key":"15","doi-asserted-by":"publisher","unstructured":"15. Nadjiri J, Waggershauser T, M\u00fchlmann M, et al. Transjugular intrahepatic portosystemic shunt creation (TIPS) in the angio-CT-a hybrid intervention with image fusion. Eur Radiol. 2023; 33: 7380-7387. doi:10.1007\/s00330-023-09793-9.","DOI":"10.1007\/s00330-023-09793-9"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16. Shahid H, Tyberg A, Sarkar A, et al. EUS-guided versus percutaneous liver abscess drainage: a multicenter collaborative study. Endosc Ultrasound. 2023; 12: 472-476. doi:10.1097\/eus.0000000000000033.","DOI":"10.1097\/eus.0000000000000033"},{"key":"17","doi-asserted-by":"publisher","unstructured":"17. Zhang H, Chen GY, Xiao L, et al. Ultrasonic\/CT image fusion guidance facilitating percutaneous catheter drainage in treatment of acute pancreatitis complicated with infected walled-off necrosis. Pancreatology. 2018; 18: 635-641. doi:10.1016\/j.pan.2018.06.004.","DOI":"10.1016\/j.pan.2018.06.004"},{"key":"18","doi-asserted-by":"publisher","unstructured":"18. Sato R, Aramaki T, Yoza K, et al. &quot;Direct MPR&quot;: a useful tool for oblique CT fluoroscopy-assisted puncture. Cardiovasc Intervent Radiol. 2017; 40: 1261-1266. doi:10.1007\/s00270-017-1642-0.","DOI":"10.1007\/s00270-017-1642-0"}],"container-title":["Interventional Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/interventionalradiology\/11\/0\/11_2025-0051\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T04:51:42Z","timestamp":1770439902000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/interventionalradiology\/11\/0\/11_2025-0051\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,2]]},"references-count":18,"journal-issue":{"issue":"0","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.22575\/interventionalradiology.2025-0051","relation":{},"ISSN":["2432-0935"],"issn-type":[{"value":"2432-0935","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,2]]},"article-number":"2025-0051"}}