{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,7,12]],"date-time":"2024-07-12T09:07:03Z","timestamp":1720775223333},"reference-count":29,"publisher":"Japanese Society for Spine Surgery and Related Research","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Spine Surg Relat Res"],"published-print":{"date-parts":[[2022,9,27]]},"DOI":"10.22603\/ssrr.2021-0197","type":"journal-article","created":{"date-parts":[[2022,3,3]],"date-time":"2022-03-03T22:12:59Z","timestamp":1646345579000},"page":"533-539","source":"Crossref","is-referenced-by-count":2,"title":["Novel Modular Spine Blocks Affect the Lumbar Spine on Finite Element Analysis"],"prefix":"10.22603","volume":"6","author":[{"given":"Jui-Yang","family":"Hsieh","sequence":"first","affiliation":[{"name":"Department of Biomedical Engineering, National Taiwan University"},{"name":"Department of Orthopedic Surgery, National Taiwan University Hospital"},{"name":"Department of Orthopedic Surgery, National Taiwan University Hospital, Jinshan Branch"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shao-Ming","family":"Chuang","sequence":"additional","affiliation":[{"name":"Department of Physical Therapy and Assistive Technology, National Yang Ming Chiao Tung University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chen-Sheng","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Physical Therapy and Assistive Technology, National Yang Ming Chiao Tung University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jyh-Horng","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, National Taiwan University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Po-Quang","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, National Taiwan University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yi-You","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, National Taiwan University"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"9891","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Chapman J, Smith JS, Kopjar B, et al. The AOSpine North America Geriatric Odontoid Fracture Mortality Study: a retrospective review of mortality outcomes for operative versus nonoperative treatment of 322 patients with long-term follow-up. Spine. 2013;38 (13):1098-4.","DOI":"10.1097\/BRS.0b013e318286f0cf"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2. Kohno M, Iwamura Y, Inasaka R, et al. Surgical intervention for osteoporotic vertebral burst fractures in middle-low lumbar spine with special reference to postoperative complications affecting surgical outcomes. Neurol Med Chir. 2019;59 (3):98-105.","DOI":"10.2176\/nmc.oa.2018-0232"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Chen HY, Chen CL, Chen WL. Repeated adjacent segment diseases and fractures in osteoporotic patients: a case report. Ther Clin Risk Manag. 2016;12:1145-50.","DOI":"10.2147\/TCRM.S112656"},{"key":"4","unstructured":"4. Galibert P, Deramond H, Rosat P, et al. Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty. Neurochirurgie. 1987;33 (2):166-8."},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Flors L, Lonjedo E, Leiva-Salinas C, et al. Vesselplasty: a new technical approach to treat symptomatic vertebral compression fractures. AJR Am J Roentgenol. 2009;193 (1):218-26.","DOI":"10.2214\/AJR.08.1503"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Noriega D, Marcia S, Theumann N, et al. A prospective, international, randomized, noninferiority study comparing an titanium implantable vertebral augmentation device versus balloon kyphoplasty in the reduction of vertebral compression fractures (SAKOS study). Spine J. 2020;20 (12):2039-40.","DOI":"10.1016\/j.spinee.2020.08.021"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Ottardi C, La Barbera L, Pietrogrande L, et al. Vertebroplasty and kyphoplasty for the treatment of thoracic fractures in osteoporotic patients: a finite element comparative analysis. J Appl Biomater Funct Mater. 2016;14 (2):e197-204.","DOI":"10.5301\/jabfm.5000287"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Hsieh JY. Osteoporosis of the spine: Asian perspectives. Toh Tuck Link (Singapore): World Scientific; 2021. Chapter 27, Minimally invasive management of osteoporotic vertebral compression fractures; p. 615-34.","DOI":"10.1142\/9789811220814_0027"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Chen SH, Zhong ZC, Chen CS, et al. Biomechanical comparison between lumbar disc arthroplasty and fusion. Med Eng Phys. 2009;31 (2):244-53.","DOI":"10.1016\/j.medengphy.2008.07.007"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Liu CL, Zhong ZC, Shih SL, et al. Influence of Dynesys system screw profile on adjacent segment and screw. J Spinal Disord Tech. 2010;23 (6):410-7.","DOI":"10.1097\/BSD.0b013e3181b63d89"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Zhong ZC, Chen SH, Hung CH. Load- and displacement-controlled finite element analyses on fusion and non-fusion spinal implants. Proc Inst Mech Eng H. 2009;223 (2):143-57.","DOI":"10.1243\/09544119JEIM476"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Shih SL, Chen CS, Lin HM, et al. Effect of spacer diameter of the Dynesys dynamic stabilization system on the biomechanics of the lumbar spine: a finite element analysis. J Spinal Disord Tech. 2012;25 (5):E140-9.","DOI":"10.1097\/BSD.0b013e31824e5e10"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13. Rubert\u00e9 LM, Natarajan RN, Andersson GB. Influence of single-level lumbar degenerative disc disease on the behavior of the adjacent segments--a finite element model study. J Biomech. 2009;42 (3):341-8.","DOI":"10.1016\/j.jbiomech.2008.11.024"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14. Salvatore G, Berton A, Giambini H, et al. Biomechanical effects of metastasis in the osteoporotic lumbar spine: a finite element analysis. BMC Musculoskelet Disord. 2018;19 (1):38.","DOI":"10.1186\/s12891-018-1953-6"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Zhong ZC, Hung C, Lin HM, et al. The influence of different magnitudes and methods of applying preload on fusion and disc replacement constructs in the lumbar spine: a finite element analysis. Comput Methods Biomech Biomed Eng. 2013;16 (9):943-53.","DOI":"10.1080\/10255842.2011.645226"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16. Rohlmann A, Neller S, Claes L, et al. Influence of a follower load on intradiscal pressure and intersegmental rotation of the lumbar spine. Spine. 2001;26 (24):E557-61.","DOI":"10.1097\/00007632-200112150-00014"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17. Dreischarf M, Zander T, Shirazi-Adl A, et al. Comparison of eight published static finite element models of the intact lumbar spine: predictive power of models improves when combined together. J Biomech. 2014;47 (8):1757-66.","DOI":"10.1016\/j.jbiomech.2014.04.002"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18. Fukuhara M, Sanpei A. Elastic moduli and internal frictions of Inconel 718 and Ti-6Al-4V as a function of temperature. J Mater Sci Lett. 1993;12 (14):1122-4.","DOI":"10.1007\/BF00420541"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19. Long M, Rack H. Titanium alloys in total joint replacement-a materials science perspective. Biomaterials. 1989;19 (18):1621-39.","DOI":"10.1016\/S0142-9612(97)00146-4"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20. Chen CS, Huang CH, Shih SL. Biomechanical evaluation of a new pedicle screw-based posterior dynamic stabilization device (awesome rod system) --a finite element analysis. BMC Musculoskelet Disord. 2015;16:81.","DOI":"10.1186\/s12891-015-0538-x"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21. Panjabi MM. Hybrid multidirectional test method to evaluate spinal adjacent-level effects. Clin Biomech. 2007;22 (3):257-65.","DOI":"10.1016\/j.clinbiomech.2006.08.006"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22. Iyer S, Christiansen BA, Roberts BJ, et al. A biomechanical model for estimating loads on thoracic and lumbar vertebrae. Clin Biomech. 2010;25 (9):853-8.","DOI":"10.1016\/j.clinbiomech.2010.06.010"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23. Yamamoto I, Panjabi MM, Crisco T, et al. Three-dimensional movements of the whole lumbar spine and lumbosacral joint. Spine. 1989;14 (11):1256-60.","DOI":"10.1097\/00007632-198911000-00020"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24. Rohlmann A, Boustani HN, Bergmann G, et al. A probabilistic finite element analysis of the stresses in the augmented vertebral body after vertebroplasty. Eur Spine J. 2010;19 (9):1585-95.","DOI":"10.1007\/s00586-010-1386-x"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25. Kr\u00fcger A, B\u00e4umlein M, Knauf T, et al. Height and volume restoration in osteoporotic vertebral compression fractures: a biomechanical comparison of standard balloon kyphoplasty versus Tektona in a cadaveric fracture model. BMC Musculoskelet Disord. 2021;22 (1):76.","DOI":"10.1186\/s12891-020-03899-7"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26. La Barbera L, Cianfoni A, Ferrari A, et al. Stent-screw assisted internal fixation of osteoporotic vertebrae: a comparative finite element analysis on SAIF technique. Front Bioeng Biotechnol. 2019;7:291.","DOI":"10.3389\/fbioe.2019.00291"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27. Buechel FF, Pappas MJ. Principles of human joint replacement: design and clinical application. 2nd ed. Heidelberg (Berlin): Springer; 2011. Chapter 1, Properties of materials used in orthopaedic implant systems; p. 1-35.","DOI":"10.1007\/978-3-642-23011-0_1"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28. Vaccaro AR, Oner C, Kepler CK, et al. AOSpine Spinal Cord Injury &amp; Trauma Knowledge Forum. AOSpine thoracolumbar spine injury classification system: fracture description, neurological status, and key modifiers. Spine. 2013;38 (23):2028-37.","DOI":"10.1097\/BRS.0b013e3182a8a381"},{"key":"29","doi-asserted-by":"crossref","unstructured":"29. Rohlmann A, Zander T, Bergmann G. Spinal loads after osteoporotic vertebral fractures treated by vertebroplasty or kyphoplasty. Eur Spine J. 2006;15 (8):1255-64.","DOI":"10.1007\/s00586-005-0018-3"}],"container-title":["Spine Surgery and Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/ssrr\/6\/5\/6_2021-0197\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,9]],"date-time":"2024-05-09T05:21:24Z","timestamp":1715232084000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/ssrr\/6\/5\/6_2021-0197\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,27]]},"references-count":29,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.22603\/ssrr.2021-0197","relation":{},"ISSN":["2432-261X"],"issn-type":[{"value":"2432-261X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,27]]},"article-number":"2021-0197"}}