{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T02:36:51Z","timestamp":1793759811948,"version":"4.6.1"},"reference-count":23,"publisher":"Japanese Society for Spine Surgery and Related Research","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Spine Surg Relat Res"],"published-print":{"date-parts":[[2023,11,27]]},"DOI":"10.22603\/ssrr.2023-0057","type":"journal-article","created":{"date-parts":[[2023,7,5]],"date-time":"2023-07-05T22:12:06Z","timestamp":1688595126000},"page":"496-503","source":"Crossref","is-referenced-by-count":9,"title":["Intraoperative Radiation Exposure from O-arm-based 3D Navigation in Spine Surgery"],"prefix":"10.22603","volume":"7","author":[{"given":"Kazuya","family":"Yokota","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Japan Labor Health and Welfare Organization Spinal Injuries Center"},{"name":"Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Osamu","family":"Kawano","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Japan Labor Health and Welfare Organization Spinal Injuries Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroaki","family":"Sakai","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Japan Labor Health and Welfare Organization Spinal Injuries Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuichiro","family":"Morishita","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Japan Labor Health and Welfare Organization Spinal Injuries Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muneaki","family":"Masuda","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Japan Labor Health and Welfare Organization Spinal Injuries Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tetsuo","family":"Hayashi","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Japan Labor Health and Welfare Organization Spinal Injuries Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kensuke","family":"Kubota","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Japan Labor Health and Welfare Organization Spinal Injuries Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideaki","family":"Hirashima","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryota","family":"Nakashima","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasuharu","family":"Nakashima","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeshi","family":"Maeda","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Japan Labor Health and Welfare Organization Spinal Injuries Center"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"9891","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Kochanski RB, Lombardi JM, Laratta JL, et al. Image-guided navigation and robotics in spine surgery. Neurosurgery. 2019;84 (6):1179-89.","DOI":"10.1093\/neuros\/nyy630"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2. Chakravarthy V, Sheikh S, Schmidt E, et al. Imaging technologies in spine surgery. Neurosurg Clin N Am. 2020;31 (1):93-101.","DOI":"10.1016\/j.nec.2019.08.011"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Xiao R, Miller JA, Sabharwal NC, et al. Clinical outcomes following spinal fusion using an intraoperative computed tomographic 3D imaging system. J Neurosurg Spine. 2017;26 (5):628-37.","DOI":"10.3171\/2016.10.SPINE16373"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Sembrano JN, Santos ER, Polly DW, Jr. New generation intraoperative three-dimensional imaging (O-arm) in 100 spine surgeries: does it change the surgical procedure? J Clin Neurosci. 2014;21 (2):225-31.","DOI":"10.1016\/j.jocn.2013.04.011"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Liu H, Chen W, Liu T, et al. Accuracy of pedicle screw placement based on preoperative computed tomography versus intraoperative data set acquisition for spinal navigation system. J Orthop Surg (Hong Kong). 2017;25 (2):2309499017718901.","DOI":"10.1177\/2309499017718901"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Mahajan A, Samuel S, Saran AK, et al. Occupational radiation exposure from C arm fluoroscopy during common orthopaedic surgical procedures and its prevention. J Clin Diagn Res. 2015;9 (3):Rc01-4.","DOI":"10.7860\/JCDR\/2015\/10520.5672"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Yoon HS, Heo JH, Lee SH, et al. Squamous cell carcinoma on the fingers of orthopedic surgeon induced by occupational radiation exposure. Ann Dermatol. 2019;31 (2):251-3.","DOI":"10.5021\/ad.2019.31.2.251"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Funao H, Ishii K, Momoshima S, et al. Surgeons&apos; exposure to radiation in single- and multi-level minimally invasive transforaminal lumbar interbody fusion; a prospective study. PLOS ONE. 2014;9 (4):e95233.","DOI":"10.1371\/journal.pone.0095233"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Asari T, Rokunohe D, Sasaki E, et al. Occupational ionizing radiation-induced skin injury among orthopedic surgeons: a clinical survey. J Orthop Sci. 2022;27 (1):266-71. eng.","DOI":"10.1016\/j.jos.2020.11.008"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Scott MC, Galivanche AR, Mets EJ, et al. Patients&apos; and physicians&apos; knowledge of radiation exposure related to spine surgery. Spine. 2020;45 (22):E1507-15.","DOI":"10.1097\/BRS.0000000000003650"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Larson AN, Schueler BA, Dubousset J. Radiation in spine deformity: state-of-the-art reviews. Spine Deform. 2019;7 (3):386-94.","DOI":"10.1016\/j.jspd.2019.01.003"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Schouten R, Lee R, Boyd M, et al. Intra-operative cone-beam CT (O-arm) and stereotactic navigation in acute spinal trauma surgery. J Clin Neurosci. 2012;19 (8):1137-43.","DOI":"10.1016\/j.jocn.2012.01.020"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13. Theologis AA, Burch S. Safety and efficacy of reconstruction of complex cervical spine pathology using pedicle screws inserted with stealth navigation and 3D image-guided (O-arm) technology. Spine. 2015;40 (18):1397-406.","DOI":"10.1097\/BRS.0000000000001026"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14. Va\u00f1\u00f3 E, Miller DL, Martin CJ, et al. ICRP Publication 135: diagnostic reference levels in medical imaging. Ann ICRP. 2017;46 (1):1-144.","DOI":"10.1177\/0146645317717209"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Hayton A, Wallace A, Marks P, et al. Australian diagnostic reference levels for multi detector computed tomography. Australas Phys Eng Sci Med. 2013;36 (1):19-26.","DOI":"10.1007\/s13246-013-0180-6"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16. Matsunaga Y, Chida K, Kondo Y, et al. Diagnostic reference levels and achievable doses for common computed tomography examinations: results from the Japanese nationwide dose survey. Br J Radiol. 2019;92 (1094):20180290.","DOI":"10.1259\/bjr.20180290"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17. Kanal KM, Butler PF, Sengupta D, et al. U.S. diagnostic reference levels and achievable doses for 10 adult CT examinations. Radiology. 2017;284 (1):120-33.","DOI":"10.1148\/radiol.2017161911"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18. Cheng EY, Naranje SM, Ritenour ER. Radiation dosimetry of intraoperative cone-beam compared with conventional CT for radiofrequency ablation of osteoid osteoma. J Bone Joint Surg Am Volume. 2014;96 (9):735-42.","DOI":"10.2106\/JBJS.M.00874"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19. Hur JW, Kim JS, Ryu KS, et al. Accuracy and safety in screw placement in the high cervical spine: retrospective analysis of O-arm-based navigation-assisted C1 lateral mass and C2 pedicle screws. Clin Spine Surg. 2019;32 (4):E193-e9.","DOI":"10.1097\/BSD.0000000000000813"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20. Costa F, Porazzi E, Restelli U, et al. Economic study: a cost-effectiveness analysis of an intraoperative compared with a preoperative image-guided system in lumbar pedicle screw fixation in patients with degenerative spondylolisthesis. Spine J. 2014;14 (8):1790-6.","DOI":"10.1016\/j.spinee.2013.10.019"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21. Urbanski W, Jurasz W, Wolanczyk M, et al. Increased radiation but no benefits in pedicle screw accuracy with navigation versus a freehand technique in scoliosis surgery. Clin Orthop Relat Res. 2018;476 (5):1020-7.","DOI":"10.1007\/s11999.0000000000000204"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22. Harada GK, Siyaji ZK, Younis S, et al. Imaging in spine surgery: current concepts and future directions. Spine Surg Relat Res. 2020;4 (2):99-110.","DOI":"10.22603\/ssrr.2020-0011"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23. Dea N, Fisher CG, Batke J, et al. Economic evaluation comparing intraoperative cone beam CT-based navigation and conventional fluoroscopy for the placement of spinal pedicle screws: a patient-level data cost-effectiveness analysis. Spine J. 2016;16 (1):23-31.","DOI":"10.1016\/j.spinee.2015.09.062"}],"container-title":["Spine Surgery and Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/ssrr\/7\/6\/7_2023-0057\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,13]],"date-time":"2024-05-13T04:47:50Z","timestamp":1715575670000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/ssrr\/7\/6\/7_2023-0057\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,27]]},"references-count":23,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.22603\/ssrr.2023-0057","relation":{},"ISSN":["2432-261X"],"issn-type":[{"value":"2432-261X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,27]]},"article-number":"2023-0057"}}