{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,4]],"date-time":"2026-03-04T07:37:02Z","timestamp":1772609822058,"version":"3.50.1"},"reference-count":29,"publisher":"Japanese Society for Spine Surgery and Related Research","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Spine Surg Relat Res"],"published-print":{"date-parts":[[2025,9,27]]},"DOI":"10.22603\/ssrr.2025-0012","type":"journal-article","created":{"date-parts":[[2025,4,4]],"date-time":"2025-04-04T18:09:25Z","timestamp":1743790165000},"page":"559-564","source":"Crossref","is-referenced-by-count":2,"title":["Accuracy and Safety of Pedicle Screw Insertion Using Novel Intraoperative Computed Tomography Navigation System for Spinal Fusion Surgery"],"prefix":"10.22603","volume":"9","author":[{"given":"Atsushi","family":"Kojima","sequence":"first","affiliation":[{"name":"Spine and Spinal Cord Center, Funabashi Orthopaedic Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shuhei","family":"Iwata","sequence":"additional","affiliation":[{"name":"Spine and Spinal Cord Center, Funabashi Orthopaedic Hospital"},{"name":"Department of Orthopaedic Surgery, Graduate School of Medicine, Chiba University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shigeru","family":"Kamitani","sequence":"additional","affiliation":[{"name":"Spine and Spinal Cord Center, Funabashi Orthopaedic Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoki","family":"Tsujishima","sequence":"additional","affiliation":[{"name":"Spine and Spinal Cord Center, Funabashi Orthopaedic Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hirohito","family":"Suzuki","sequence":"additional","affiliation":[{"name":"Spine and Spinal Cord Center, Funabashi Orthopaedic Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomonori","family":"Sodeyama","sequence":"additional","affiliation":[{"name":"Spine and Spinal Cord Center, Funabashi Orthopaedic Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seiji","family":"Ohtori","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Graduate School of Medicine, Chiba University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenji","family":"Hatakeyama","sequence":"additional","affiliation":[{"name":"Spine and Spinal Cord Center, Funabashi Orthopaedic Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"9891","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Reid PC, Morr S, Kaiser MG. State of the union: a review of lumbar fusion indications and techniques for degenerative spine disease. J Neurosurg Spine. 2019;31 (1):1-14.","DOI":"10.3171\/2019.4.SPINE18915"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2. Reisener MJ, Pumberger M, Shue J, et al. Trends in lumbar spinal fusion-a literature review. J Spine Surg. 2020;6 (4):752-61.","DOI":"10.21037\/jss-20-492"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Kanno H, Handa K, Murotani M, et al. A novel intraoperative CT navigation system for spinal fusion surgery in lumbar degenerative disease: accuracy and safety of pedicle screw placement. J Clin Med. 2024;13 (7):2105.","DOI":"10.3390\/jcm13072105"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Alqurashi A, Alomar SA, Bakhaidar M, et al. Accuracy of pedicle screw placement using intraoperative CT-guided navigation and conventional fluoroscopy for lumbar spondylosis. Cureus. 2021;13 (8):e17431.","DOI":"10.7759\/cureus.17431"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Zhang W, Takigawa T, Wu Y, et al. Accuracy of pedicle screw insertion in posterior scoliosis surgery: a comparison between intraoperative navigation and preoperative navigation techniques. Eur Spine J. 2017;26 (6):1756-64.","DOI":"10.1007\/s00586-016-4930-5"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Virk S, Qureshi S. Navigation in minimally invasive spine surgery. J Spine Surg. 2019;5 (suppl 1):S25-S30.","DOI":"10.21037\/jss.2019.04.23"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Heydar AM, Tanaka M, Prabhu SP, et al. The impact of navigation in lumbar spine surgery: a study of historical aspects, current techniques and future directions. J Clin Med. 2024;13 (16):4663.","DOI":"10.3390\/jcm13164663"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Oba H, Uehara M, Ikegami S, et al. Tips and pitfalls to improve accuracy and reduce radiation exposure in intraoperative CT navigation for pediatric scoliosis: a systematic review. Spine J. 2023;23 (2):183-96.","DOI":"10.1016\/j.spinee.2022.09.004"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Dea N, Fisher CG, Batke J, et al. Economic evaluation comparing intraoperative cone beam CT-based navigation and conventional fluoroscopy for the placement of spinal pedicle screws: a patient-level data cost-effectiveness analysis. Spine J. 2016;16 (1):23-31.","DOI":"10.1016\/j.spinee.2015.09.062"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Mendelsohn D, Strelzow J, Dea N, et al. Patient and surgeon radiation exposure during spinal instrumentation using intraoperative computed tomography-based navigation. Spine J. 2016;16 (3):343-54.","DOI":"10.1016\/j.spinee.2015.11.020"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Hiyama A, Katoh H, Nomura S, et al. Intraoperative computed tomography-guided navigation versus fluoroscopy for single-position surgery after lateral lumbar interbody fusion. J Clin Neurosci. 2021;93:75-81.","DOI":"10.1016\/j.jocn.2021.08.023"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Rahmathulla G, Nottmeier EW, Pirris SM, et al. Intraoperative image-guided spinal navigation: technical pitfalls and their avoidance. Neurosurg Focus. 2014;36 (3):E3.","DOI":"10.3171\/2014.1.FOCUS13516"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13. Sabatini L, Ascani D, Vezza D, et al. Novel surgical technique for total knee arthroplasty integrating kinematic alignment and real-time elongation of the ligaments using the NextAR system. J Pers Med. 2024;14 (8):794.","DOI":"10.3390\/jpm14080794"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14. Gelalis ID, Paschos NK, Pakos EE, et al. Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J. 2012;21 (2):247-55.","DOI":"10.1007\/s00586-011-2011-3"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Waschke A, Walter J, Duenisch P, et al. CT-navigation versus fluoroscopy-guided placement of pedicle screws at the thoracolumbar spine: single center experience of 4,500 screws. Eur Spine J. 2013;22 (3):654-60.","DOI":"10.1007\/s00586-012-2509-3"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16. La Rocca G, Mazzucchi E, Pignotti F, et al. Intraoperative CT-guided navigation versus fluoroscopy for percutaneous pedicle screw placement in 192 patients: a comparative analysis. J Orthop Traumatol. 2022;23 (1):44.","DOI":"10.1186\/s10195-022-00661-8"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17. Shin MH, Ryu KS, Park CK. Accuracy and safety in pedicle screw placement in the thoracic and lumbar spines : comparison study between conventional C-arm fluoroscopy and navigation coupled with O-Arm<sup>\u00ae<\/sup> guided methods. J Korean Neurosurg Soc. 2012;52 (3):204-9.","DOI":"10.3340\/jkns.2012.52.3.204"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18. Sundaram PPM, Oh JYL, Tan M, et al. Accuracy of thoracolumbar pedicle screw insertion based on routine use of intraoperative imaging and navigation. Asian Spine J. 2021;15 (4):491-7.","DOI":"10.31616\/asj.2020.0068"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19. Shree Kumar D, Ampar N, Wee Lim L. Accuracy and reliability of spinal navigation: an analysis of over 1000 pedicle screws. J Orthop. 2020;18:197-203.","DOI":"10.1016\/j.jor.2019.10.002"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20. Kojima A, Fujii A, Morioka S, et al. Safety and efficacy of percutaneous pedicle screw placement using a power tool. Spine Surg Relat Res. 2018;2 (1):60-4.","DOI":"10.22603\/ssrr.2017-0029"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21. Kojima A, Aihara T, Urushibara M, et al. Safety and efficacy of all-in-one percutaneous pedicle screw system. Global Spine J. 2023;13 (4):970-6.","DOI":"10.1177\/21925682211011440"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22. Gautschi OP, Schatlo B, Schaller K, et al. Clinically relevant complications related to pedicle screw placement in thoracolumbar surgery and their management: a literature review of 35,630 pedicle screws. Neurosurg Focus. 2011;31 (4):E8.","DOI":"10.3171\/2011.7.FOCUS11168"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23. Otomo N, Funao H, Yamanouchi K, et al. Computed tomography-based navigation system in current spine surgery: a narrative review. Medicina (Kaunas). 2022;58 (2):241.","DOI":"10.3390\/medicina58020241"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24. Chapman TM, Blizzard DJ, Brown CR. CT accuracy of percutaneous versus open pedicle screw techniques: a series of 1609 screws. Eur Spine J. 2016;25 (6):1781-6.","DOI":"10.1007\/s00586-015-4163-z"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25. Yokota K, Kawano O, Sakai H, et al. Intraoperative radiation exposure from O-arm-based 3D navigation in spine surgery. Spine Surg Relat Res. 2023;7 (6):496-503.","DOI":"10.22603\/ssrr.2023-0057"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26. Pennington Z, Cottrill E, Westbroek EM, et al. Evaluation of surgeon and patient radiation exposure by imaging technology in patients undergoing thoracolumbar fusion: systematic review of the literature. Spine J. 2019;19 (8):1397-411.","DOI":"10.1016\/j.spinee.2019.04.003"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27. Funao H, Ishii K, Momoshima S, et al. Surgeons&apos; exposure to radiation in single- and multi-level minimally invasive transforaminal lumbar interbody fusion; a prospective study. PLoS One. 2014;9 (4):e95233.","DOI":"10.1371\/journal.pone.0095233"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28. Hijikata Y, Kamitani T, Yamamoto Y, et al. Association of occupational direct radiation exposure to the hands with longitudinal melanonychia and hand eczema in spine surgeons: a survey by the society for minimally invasive spinal treatment (MIST). Eur Spine J. 2021;30 (12):3702-8.","DOI":"10.1007\/s00586-021-06973-3"},{"key":"29","doi-asserted-by":"crossref","unstructured":"29. Hijikata Y, Kotani Y, Suzuki A, et al. Protective attitudes toward occupational radiation exposure among spine surgeons in Japan: an epidemiological description from the survey by the society for minimally invasive spinal treatment. Medicina (Kaunas). 2023;59 (3):545.","DOI":"10.3390\/medicina59030545"}],"container-title":["Spine Surgery and Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/ssrr\/9\/5\/9_2025-0012\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,27]],"date-time":"2025-09-27T03:34:30Z","timestamp":1758944070000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/ssrr\/9\/5\/9_2025-0012\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,27]]},"references-count":29,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.22603\/ssrr.2025-0012","relation":{},"ISSN":["2432-261X"],"issn-type":[{"value":"2432-261X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,27]]},"article-number":"2025-0012"}}