{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,31]],"date-time":"2026-01-31T19:05:37Z","timestamp":1769886337169,"version":"3.49.0"},"reference-count":7,"publisher":"Japanese Society for Spine Surgery and Related Research","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Spine Surg Relat Res"],"published-print":{"date-parts":[[2026,1,27]]},"DOI":"10.22603\/ssrr.2025-0132","type":"journal-article","created":{"date-parts":[[2025,8,26]],"date-time":"2025-08-26T22:08:05Z","timestamp":1756246085000},"page":"120-126","source":"Crossref","is-referenced-by-count":0,"title":["Biomechanical Study of Pedicle Screw Fixation Comparing Intracortical Pedicle Screw and Oversized Pedicle Screw"],"prefix":"10.22603","volume":"10","author":[{"given":"Hiroaki","family":"Manabe","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, Institute of Biomedical Sciences, Tokushima University Graduate School"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kosaku","family":"Higashino","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Institute of Biomedical Sciences, Tokushima University Graduate School"},{"name":"Department of Orthopedics and Rehabilitation, National Hospital Organization Shikoku Medical Center for Children and Adults"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toru","family":"Maeda","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Anan Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuichiro","family":"Goda","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Kochi Red Cross Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masatoshi","family":"Morimoto","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Institute of Biomedical Sciences, Tokushima University Graduate School"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuta","family":"Yamashita","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Institute of Biomedical Sciences, Tokushima University Graduate School"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koichi","family":"Tomita","sequence":"additional","affiliation":[{"name":"Department of Anatomy, Institute of Biomedical Sciences, Tokushima University Graduate School"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koichi","family":"Sairyo","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Institute of Biomedical Sciences, Tokushima University Graduate School"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"9891","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Boucher HH. A method of spinal fusion. J Bone Joint Surg Br. 1959;41-B (2):248-59.","DOI":"10.1302\/0301-620X.41B2.248"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2. Roy-Camille R, Saillant G, Mazel C. Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res. 1986; (203):7-17.","DOI":"10.1097\/00003086-198602000-00003"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Goda Y, Higashino K, Toki S, et al. The pullout strength of pedicle screws following redirection after lateral wall breach or end plate breach. Spine. 2016;41 (15):1218-23.","DOI":"10.1097\/BRS.0000000000001600"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Stauff MP, Freedman BA, Kim JH, et al. The effect of pedicle screw redirection after lateral wall breach-a biomechanical study using human lumbar vertebrae. Spine J. 2014;14 (1):98-103.","DOI":"10.1016\/j.spinee.2013.03.028"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Maeda T, Higashino K, Manabe H, et al. Pullout strength of pedicle screws following redirection after lateral or medial wall breach. Spine. 2018;43 (17):E983-9.","DOI":"10.1097\/BRS.0000000000002611"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Silbermann J, Riese F, Allam Y, et al. Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: comparison between free-hand and O-arm based navigation techniques. Eur Spine J. 2011;20 (6):875-81.","DOI":"10.1007\/s00586-010-1683-4"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Yan K, Zhang Q, Tian W. Comparison of accuracy and safety between second-generation TiRobot-assisted and free-hand thoracolumbar pedicle screw placement. BMC Surg. 2022;22 (1):275.","DOI":"10.1186\/s12893-022-01723-8"}],"container-title":["Spine Surgery and Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/ssrr\/10\/1\/10_2025-0132\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,31]],"date-time":"2026-01-31T03:44:51Z","timestamp":1769831091000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/ssrr\/10\/1\/10_2025-0132\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,27]]},"references-count":7,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.22603\/ssrr.2025-0132","relation":{},"ISSN":["2432-261X"],"issn-type":[{"value":"2432-261X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,27]]},"article-number":"2025-0132"}}