{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,30]],"date-time":"2026-05-30T04:03:56Z","timestamp":1780113836220,"version":"3.54.0"},"reference-count":25,"publisher":"Japanese Society for Spine Surgery and Related Research","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Spine Surg Relat Res"],"published-print":{"date-parts":[[2026,5,27]]},"DOI":"10.22603\/ssrr.2025-0307","type":"journal-article","created":{"date-parts":[[2025,12,24]],"date-time":"2025-12-24T22:27:00Z","timestamp":1766615220000},"page":"440-447","source":"Crossref","is-referenced-by-count":0,"title":["Oblique-View Method Improves the Detection of cement leakage in Cement-Augmented Pedicle Screw Fixation"],"prefix":"10.22603","volume":"10","author":[{"given":"Kazuya","family":"Kishima","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Hyogo Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keishi","family":"Maruo","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Hyogo Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fumihiro","family":"Arizumi","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Hyogo Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tetsuto","family":"Yamaura","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Hyogo Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masaru","family":"Hatano","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Hyogo Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hayato","family":"Oishi","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Miyoshi Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuma","family":"Nagao","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Ashiya St. Maria Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kei","family":"Takagi","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Sakai Heisei Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuki","family":"Ishida","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Daiwa Central Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiya","family":"Tachibana","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Hyogo Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"9891","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Nohara Y, Taneichi H, Ueyama K, et al. Nationwide survey on complications of spine surgery in Japan. J Orthop Sci. 2004;9 (5):424-33.","DOI":"10.1007\/s00776-004-0802-7"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2. Yamato Y, Matsuyama Y, Hasegawa K, et al. A Japanese nationwide multicenter survey on perioperative complications of corrective fusion for elderly patients with adult spinal deformity. J Orthop Sci. 2017;22 (2):237-42.","DOI":"10.1016\/j.jos.2016.11.006"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Tanaka T, Sasaki M, Katayanagi J, et al. Trends, costs, and complications associated with after-hours surgery and unscheduled hospitalization in spinal surgery. Bone Jt Open. 2024;5 (8):662-70.","DOI":"10.1302\/2633-1462.58.BJO-2024-0026.R1"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Lechtholz-Zey EA, Ayad M, Gettleman BS, et al. Systematic review and meta-analysis of the effect of osteoporosis on reoperation rates and complications after surgical management of lumbar degenerative disease. J Bone Metab. 2024;31 (2):114-31.","DOI":"10.11005\/jbm.2024.31.2.114"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Boucas P, Mamdouhi T, Rizzo SE, et al. Cement augmentation of pedicle screw instrumentation: a literature review. Asian Spine J. 2023;17 (5):939-48.","DOI":"10.31616\/asj.2022.0216"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Singh V, Mahajan R, Das K, et al. Surgical trend analysis for use of cement augmented pedicle screws in osteoporosis of spine: a systematic review (2000-2017). Glob Spine J. 2019;9 (7):783-95.","DOI":"10.1177\/2192568218801570"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Yagi M, Ogiri M, Holy CE, et al. Comparison of clinical effectiveness of fenestrated and conventional pedicle screws in patients undergoing spinal surgery: a systematic review and meta-analysis. Expert Rev Med Devices. 2021;18 (10):995-1022.","DOI":"10.1080\/17434440.2021.1977123"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Wang Y, Zhou C, Yin H, et al. Comparison of cement-augmented pedicle screw and conventional pedicle screw for the treatment of lumbar degenerative patients with osteoporosis. Eur J Orthop Surg Traumatol. 2024;34 (3):1609-17.","DOI":"10.1007\/s00590-024-03849-2"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Song Z, Zhou Q, Jin X, et al. Cement-augmented pedicle screw for thoracolumbar degenerative diseases with osteoporosis: a systematic review and meta-analysis. J Orthop Surg Res. 2023;18 (1):631.","DOI":"10.1186\/s13018-023-04077-w"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Guo HZ, Tang YC, Guo DQ, et al. The cement leakage in cement-augmented pedicle screw instrumentation in degenerative lumbosacral diseases: a retrospective analysis of 202 cases and 950 augmented pedicle screws. Eur Spine J. 2019;28 (7):1661-9.","DOI":"10.1007\/s00586-019-05985-4"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Liu YY, Xiao J, He L, et al. Risk factor analysis of bone cement leakage for polymethylmethacrylate-augmented cannulated pedicle screw fixation in spinal disorders. Heliyon. 2023;9 (4):e15167.","DOI":"10.1016\/j.heliyon.2023.e15167"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Zhang J, Wang G, Zhang N. A meta-analysis of complications associated with the use of cement-augmented pedicle screws in osteoporosis of spine. Orthop Traumatol Surg Res. 2021;107 (7):102791.","DOI":"10.1016\/j.otsr.2020.102791"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13. Takahashi S, Sakai D, Ogasawara S, et al. The risk of intravenous cement leakage and short-term outcomes of selective cement-augmented pedicle screws: a multicenter retrospective study. Clin Spine Surg. 2025;38 (7):E419-24.","DOI":"10.1097\/BSD.0000000000001757"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14. Morimoto T, Kobayashi T, Hirata H, et al. Cardiopulmonary cement embolism following cement-augmented pedicle screw fixation: a narrative review. Medicina (Kaunas). 2023;59 (2):407.","DOI":"10.3390\/medicina59020407"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Takahashi S, Sohgawa E, Suzuki A, et al. Percutaneous endovascular retrieval of large cement leakage into the right atrium following cement-augmented pedicle screw instrumentation. Spine Surg Relat Res. 2021;5 (6):446-9.","DOI":"10.22603\/ssrr.2021-0011"},{"key":"16","unstructured":"16. Kishima K, Maruo K, Arizumi F, et al. Study of cement leakage in fenestrated pedicle screws. Spine Res. 2024;15 (6):947-52."},{"key":"17","doi-asserted-by":"crossref","unstructured":"17. Schnake KJ, Blattert TR, Hahn P, et al. Classification of osteoporotic thoracolumbar spine fractures: recommendations of the spine section of the German society for orthopaedics and trauma (DGOU). Glob Spine J. 2018;8 (2) (suppl):46S-9S.","DOI":"10.1177\/2192568217717972"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18. Kanda Y. Investigation of the freely available easy-to-use software &quot;EZR&quot; for medical statistics. Bone Marrow Transplant. 2013;48 (3):452-8.","DOI":"10.1038\/bmt.2012.244"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19. Mueller JU, Baldauf J, Marx S, et al. Cement leakage in pedicle screw augmentation: a prospective analysis of 98 patients and 474 augmented pedicle screws. J Neurosurg Spine. 2016;25 (1):103-9.","DOI":"10.3171\/2015.10.SPINE15511"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20. Yamashita K, Tamaki Y, Nakajima D, et al. A cadaveric simulation study of radiation exposure to the surgical team during fluoroscopic spinal surgery: how much are we exposed? Spine Surg Relat Res. 2023;7 (4):341-9.","DOI":"10.22603\/ssrr.2022-0184"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21. Yeom JS, Kim WJ, Choy WS, et al. Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures. J Bone Joint Surg Br. 2003;85 (1):83-9.","DOI":"10.1302\/0301-620X.85B1.13026"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22. Tamagawa S, Nojiri H, Takano H, et al. Risk factors for cement leakage in cement-augmented pedicle screw fixation: a multicenter study of 140 patients and 650 screws. Glob Spine J. 2025;16 (1):670-8","DOI":"10.1177\/21925682251357826"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23. Janssen I, Ryang YM, Gempt J, et al. Risk of cement leakage and pulmonary embolism by bone cement-augmented pedicle screw fixation of the thoracolumbar spine. Spine J. 2017;17 (6):837-44.","DOI":"10.1016\/j.spinee.2017.01.009"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24. Leichtle CI, Lorenz A, Rothstock S, et al. Pull-out strength of cemented solid versus fenestrated pedicle screws in osteoporotic vertebrae. Bone Joint Res. 2016;5 (9):419-26.","DOI":"10.1302\/2046-3758.59.2000580"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25. Yuan W, Cao W, Meng X, et al. Learning curve of robot-assisted percutaneous kyphoplasty for osteoporotic vertebral compression fractures. World Neurosurg. 2020;138:e323-9.","DOI":"10.1016\/j.wneu.2020.02.110"}],"container-title":["Spine Surgery and Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/ssrr\/10\/3\/10_2025-0307\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,30]],"date-time":"2026-05-30T03:24:58Z","timestamp":1780111498000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/ssrr\/10\/3\/10_2025-0307\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,27]]},"references-count":25,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.22603\/ssrr.2025-0307","relation":{},"ISSN":["2432-261X"],"issn-type":[{"value":"2432-261X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,27]]},"article-number":"2025-0307"}}